Effective June 2017
Technical Data 1030
Supersedes July 2013
250 V NON/600 V NOS Class K5 and H fuses
Catalog numbers (amps)
NON-1/8
NON-1/2
NON-3/4
NON-8/10
NON-1
NON-3
NON-12 NON-65 NON-200
NON-3-2/10 NON-15 NON-70 NON-225
NON-4
NON-5
NON-6
NON-20 NON-75 NON-250
NON-25 NON-80 NON-300
NON-30 NON-90 NON-350
NON-1-1/4
NON-1-1/2
NON-1-6/10 NON-8
NON-2
NON-2-1/2
NON-6-1/4 NON-35 NON-100 NON-400
NON-7
NON-40 NON-110 NON-450
NON-45 NON-125 NON-500
NON-50 NON-150 NON-600
NON-60 NON-175
NON-9
NON-10
Carton quantity
Amps
Qty.
10
5
1/8-60
65–100
110–600
1
Description
Dimensions – in
All Diameters 0.00ꢀ
Basic protection 250V NON Class K5 and H
general purpose, non-current-limiting, one-time
fuses.
10.3ꢀ" ( 0.09ꢁ8
2"
(0.0318
0.56" ( 0.00ꢀ8
1/ꢀ to 30A
2.59"
Catalog symbol
ꢁ50 to 600A
•ꢀ
NON-(amp)
3"
ꢀ.63" ( 0.09ꢁ8
(0.0318
Ratings
2.06"
1.56"
0.ꢀ1" ( 0.00ꢀ8
35 to 60A
•ꢀ
Volts
•ꢀ 250 Vac
225 to ꢁ00A
•ꢀ 125 Vdc (1/8-100 A)
5.ꢀꢀ" ( 0.0628
7.13" ( 0.0628
•ꢀ
Amps 1/8-600 A
1.06"
•ꢀ
IR
110 to 200A
65 to 100A
Features
•ꢀ 50 kA Vac RMS Sym. (1/8-60 A)
•ꢀ 10 kA Vac RMS Sym. (65-600 A)
•ꢀ 50 kA Vdc (1/8-60 A)
•ꢀ
Protect lighting, heating and other circuits
not subject to temporary surges and where
available short-circuit currents are relatively low
•ꢀ 10 kA Vdc (65-100 A)
•ꢀ
NON one-time fuses do not have any
appreciable degree of timedelay and thus
should not be specified in circuits where
large transients or motor overloads occur.
Use Bussmann series advanced protection
FUSETRON™ FRN-R or ultimate protection
Low-Peak™ LPN-RK dual-element, time-delay
fuses.
Agency information
•ꢀ
UL Listed, Class K5 (1/8-60 A), Std. 248-9, Class
H (65-600 A), Std. 248-6 (125 Vdc 1/8-100 A), UL
Guide JDDZ, File E4273
•ꢀ
CSA Certified, Class 1421-01, File 53787 (1/8-12
A, 65-600 A)†
•ꢀ
•ꢀ
•ꢀ
CE
For general purpose circuits, size at amp rating
of circuit
† For CSA Certified 15-60 A, see PON data sheet no. 4126.
For motor circuits, size at 300% to 400%
according to the NEC® motor ampacity tables
430.247 to 430.250, per 430.6(A)(1)
Technical Data 1030
250 V NON/600 V NOS Class K5 and H fuses
Effective June 2017
Recommended fuse blocks
NON time-current curves — average melt
•ꢀ
1-, 2- and 3-pole modular fuse blocks up to 600 amps — see data
sheet no. 10487
AMP RATING
•ꢀ
1-, 2- and 3-pole modular power distribution fuse blocks up to 60
amps — see data sheet no. 10490
300
Fuse reducers for Class R fuses
100
10
1
Desired fuse (case)
Equipment fuse clips size
Catalog no. (pairs)
250V
60 A
30 A
NO.263
30 A
NO.213
100 A
60 A
NO.216
60 A
NO.226
200 A
400 A
100 A
100 A
200 A
100 A
200 A
400 A
NO.2621
NO.2641†
NO.2642
NO.2661†
NO.2662†
NO.2664†
600 A
† Not CSA certified.
For additional information on Class K5 & H fuse reducers, see data
sheet no. 1118.
0.1
0.01
CURRENT IN AMPS
2
Eaton.com/bussmannseries
250 V NON/600 V NOS Class K5 and H fuses
Technical Data 1030
Effective June 2017
Dimensions – in
All Diameters 0.008
5" ( 0.0ꢁ1ꢀ
1ꢁ.ꢁ8" ( 0.094ꢀ
0.81" ( 0.008ꢀ
ꢁ.1ꢁ"
1 to ꢁ0A
450 to 600A
11.6ꢁ" ( 0.094ꢀ
5.5" ( 0.0ꢁ1ꢀ
ꢂ.59"
1.06" ( 0.008ꢀ
ꢁ5 to 60A
ꢂꢂ5 to 400A
9.6ꢁ" ( 0.06ꢂꢀ
7.9" ( 0.06ꢂꢀ
1.84"
1.ꢁ4"
110 to ꢂ00A
70 to 100A
Features
•ꢀ
Protect lighting, heating and other circuits not subject to
temporary surges and where available short-circuit currents are
relatively low
•ꢀ
NOS one-time fuses do not have any appreciable degree of
timedelay and thus should not be specified in circuits where
large transients or motor overloads occur. Use Bussmann series
advanced protection FUSETRON FRS-R or ultimate protection
Low-Peak LPS-RK dual-element, time-delay fuses.
Description
Basic protection 600 V NOS Class K5 and H general purpose, non-
current-limiting, one-time fuses.
•ꢀ
•ꢀ
For general purpose circuits, size at amp rating of circuit
For motor circuits, size at 300% to 400% according to the NEC®
motor ampacity tables 430.247 to 430.250, per 430.6(A)(1)
Catalog symbol
•ꢀ
NOS-(amp)
Ratings
Recommended fuse blocks
•ꢀ
Volts 600 Vac
•ꢀ
1-, 2- and 3-pole modular fuse blocks up to 600 amps — see data
sheet no. 10487
•ꢀ
Amps 1-600 A
•ꢀ
1-, 2- and 3-pole modular power distribution fuse blocks up to 60
•ꢀ
IR
amps — see data sheet no. 10490
•ꢀ 50 kA Vac RMS Sym. (1-60 A)
•ꢀ 10 kA Vac RMS Sym. (70-600 A)
Fuse reducers for Class R fuses
Equipment fuse
clips
Desired fuse
(case) size
Agency information
Catalog no. (pairs) 600V
NO.663
•ꢀ
UL Listed, Class K5 (1-60 A), Std. 248-9, Class H (70-600 A),
Std. 248-6, UL Guide JDDZ, File E4273
60 A
30 A
30 A
NO.216
•ꢀ
CSA Certified, Class 1421-01, File 53787
100 A
60 A
NO.616
•ꢀ
CE
60 A
NO.626
200 A
400 A
100 A
100 A
200 A
100 A
200 A
400 A
NO.2621
NO.2641†
Catalog Numbers (amps)
NOS-1
NOS-2
NOS-3
NOS-4
NOS-5
NOS-6
NOS-7
NOS-8
NOS-9
NOS-40
NOS-45
NOS-50
NOS-60
NOS-70
NOS-75
NOS-80
NOS-90
NOS-100
NOS-110
NOS-125
NOS-150
NOS-175
NOS-200
NOS-225
NOS-250
NOS-300
NOS-350
NOS-400
NOS-450
NOS-500
NOS-600
NO.2642
NOS-10
NOS-12
NOS-15
NOS-20
NOS-25
NOS-30
NOS-35
NO.2661†
NO.2662†
NO.2664†
600 A
† Not CSA certified.
For additional information on Class R fuse reducers, see data sheet
no 1118.
Carton Quantity
Amps
1–60
Qty.
10
5
70–100
110–600
1
Eaton.com/bussmannseries
3
Technical Data 1030
250 V NON/600 V NOS Class K5 and H fuses
Effective June 2017
NOS time-current curves — average melt
AMP RATING
300
100
10
1
0.1
0.08
0.06
0.04
0.03
0.02
0.01
CURRENT IN AMPS
The only controlled copy of this data sheet is the electronic read-only version located on the Eaton network drive. All other copies of this document are
by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the
end user with design applications. Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit
distribution of any products. Eaton also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once
a product has been selected, it should be tested by the user in all possible applications.
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
Eaton.com
Eaton, Bussmann, Low-Peak and Fusetron are
valuable trademarks of Eaton in the U.S. and
other countries. You are not permitted to use
the Eaton trademarks without prior written
Bussmann Division
114 Old State Road
Ellisville, MO 63021
United States
consent of Eaton.
Eaton.com/bussmannseries
CSA is a registered trademark of the Canadian
Standards Group.
NEC is a registered trademark of the National
Fire Protection Association.
Follow us on social media to get the
latest product and support information.
© 2017 Eaton
All Rights Reserved
Printed in USA
Publication No. 1030 — BU-SB13738
June 2017
UL is a registered trademark of the
Underwriters Laboratories, Inc.
Eaton.com/bussmannseries
相关型号:
©2020 ICPDF网 联系我们和版权申明