A2D250-AA02-47 [EBMPAPST]
Fan/Blower,;型号: | A2D250-AA02-47 |
厂家: | ebm-papst |
描述: | Fan/Blower, |
文件: | 总6页 (文件大小:714K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
A2D250-AA02-47
AC axial fan
straight blades (A series), single-intake
ebm-papst Mulfingen GmbH & Co. KG
Bachmühle 2 · D-74673 Mulfingen
Phone +49 7938 81-0
Fax +49 7938 81-110
info1@de.ebmpapst.com
www.ebmpapst.com
Limited partnership · Headquarters Mulfingen
Amtsgericht (court of registration) Stuttgart · HRA 590344
General partner Elektrobau Mulfingen GmbH · Headquarters Mulfingen
Amtsgericht (court of registration) Stuttgart · HRB 590142
Nominal data
Type
A2D250-AA02-47
M2D068-DF
Motor
Phase
3~
230
Δ
3~
230
Δ
3~
400
Y
3~
400
Y
Nominal voltage
Wiring
VAC
Hz
Frequency
50
60
50
60
Method of obtaining data
Valid for approval/standard
Speed (rpm)
fa
fa
fa
fa
CE
2650
110
0.38
250
1
CE
2950
160
0.45
300
1.2
-25
40
CE
2650
110
0.22
250
1
CE
2950
160
0.26
300
1.2
-25
40
min-1
W
Power consumption
Current draw
A
Max. back pressure
Max. back pressure
Min. ambient temperature
Max. ambient temperature
Pa
inH2O
°C
-25
70
-25
70
°C
ml = Max. load · me = Max. efficiency · fa = Free air · cs = Customer specification · ce = Customer equipment
Subject to change
Data according to ErP Directive
Actual
Req. 2015
01 Overall efficiency ηes
02 Measurement category
03 Efficiency category
04 Efficiency grade N
%
28.1
28.1
09 Power consumption Pe
09 Air flow qv
kW
0.13
1050
121
A
m³/h
Pa
Static
40
09 Pressure increase pfs
10 Speed (rpm) n
40
min-1
2600
1.00
05 Variable speed drive
No
11 Specific ratio*
Data obtained at optimum efficiency level.
* Specific ratio = 1 + pfs / 100 000 Pa
LU-69121
The ErP data is determined using a motor-impeller combination in a standardized measurement setup.
Item no. 13665-5-9980 · ENU · Change 89188 · Approved 2016-04-28 · Page 1 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
A2D250-AA02-47
AC axial fan
straight blades (A series), single-intake
Technical description
Weight
2.2 kg
Fan size
250 mm
Rotor surface
Blade material
Number of blades
Airflow direction
Direction of rotation
Degree of protection
Insulation class
Painted black
Sheet steel, painted black
5
"V"
Counterclockwise, viewed toward rotor
IP44; installation- and position-dependent as per EN 60034-5
"B"
F5
Moisture (F) / Environmental (H)
protection class
Max. permitted ambient temp.
for motor (transport/storage)
+ 80 °C
- 40 °C
Min. permitted ambient temp. for
motor (transport/storage)
Installation position
Condensation drainage holes
Mode
Any
None
S1
Motor bearing
Ball bearing
< 0.75 mA
Touch current according to IEC
60990 (measuring circuit Fig. 4,
TN system)
With cable
Lateral
Protection class
Conformity with standards
I (with customer connection of protective earth)
EN 60335-1
Item no. 13665-5-9980 · ENU · Change 89188 · Approved 2016-04-28 · Page 2 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
A2D250-AA02-47
Product drawing
AC axial fan
straight blades (A series), single-intake
1
2
3
Direction of air flow "V"
Max. clearance for screw 5 mm
Cable PVC 7G 0.5 mm², 7x crimped splices
Item no. 13665-5-9980 · ENU · Change 89188 · Approved 2016-04-28 · Page 3 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
A2D250-AA02-47
AC axial fan
straight blades (A series), single-intake
Connection diagram
Change of rotation direction by reversing two phases
Three-phase motor
Δ
Delta connection
= V1 = blue
white
Y
Star connection
= W1 = brown
yellow
L1
= U1 = black
green
L2
V2
L3
W2
U2
PE
green/yellow
Item no. 13665-5-9980 · ENU · Change 89188 · Approved 2016-04-28 · Page 4 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
A2D250-AA02-47
AC axial fan
straight blades (A series), single-intake
Curves: Air performance 50 Hz Y
Druck p
f
s[Pa]für Rho=1,2kg/m^3
qv[cfm]
600
0
200
400
800
1.000
390
380
370
360
350
340
330
320
310
300
290
280
270
260
250
240
230
220
210
200
190
180
170
160
150
140
130
120
110
100
90
1,55
1,5
1,45
1,4
Measurement: LU-69121-1
1,35
1,3
Air performance measured according to ISO
5801 installation category A. For detailed
information on the measurement setup,
contact ebm-papst. Intake sound level:
Sound power level according to ISO 13347 /
sound pressure level measured at 1 m
distance from fan axis. The values given are
valid under the specified measuring
conditions and may vary due to conditions of
installation. For deviations from the standard
configuration, the parameters have to be
checked on the installed unit.
1,25
1,2
1,15
1,1
1,05
1
0,95
0,9
0,85
0,8
0,75
0,7
0,65
0,6
0,55
0,5
4
0,45
0,4
0,35
0,3
3
80
70
0,25
0,2
60
50
2
40
0,15
0,1
30
p
f
20
s
[
0,05
0
P
a
10
1]
0
0
200
400
600
800
1.000
qv[m^3/h]
1.200
1.400
1.600
1.800
Measured values
Wired
U
f
n
Pe
I
qv
pfs
qv
pfs
V
Hz
50
50
50
50
min-1
W
A
m3/h
1720
1595
1410
1090
Pa
0
CFM
1010
940
830
645
inH2O
0.00
0.16
0.32
0.48
1
2
3
4
Y
Y
Y
Y
400
400
400
400
2650
2620
2600
2595
110
126
131
131
0.22
0.23
0.24
0.24
40
80
120
Wired = Wiring · U = Power supply · f = Frequency · n = Speed (rpm) · Pe = Power consumption · I = Current draw · qv = Air flow · pfs = Pressure increase
Item no. 13665-5-9980 · ENU · Change 89188 · Approved 2016-04-28 · Page 5 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
A2D250-AA02-47
AC axial fan
straight blades (A series), single-intake
Curves: Air performance 60 Hz Y
Druck p
f
s[Pa]für Rho=1,2kg/m^3
qv[cfm]
600
0
200
400
800
1.000
1.200
400
380
360
340
320
300
280
260
240
220
200
180
160
140
120
100
80
1,6
1,55
1,5
1,45
1,4
Measurement: LU-69123-1
1,35
1,3
Air performance measured according to ISO
5801 installation category A. For detailed
information on the measurement setup,
contact ebm-papst. Intake sound level:
Sound power level according to ISO 13347 /
sound pressure level measured at 1 m
distance from fan axis. The values given are
valid under the specified measuring
conditions and may vary due to conditions of
installation. For deviations from the standard
configuration, the parameters have to be
checked on the installed unit.
1,25
1,2
1,15
1,1
1,05
1
0,95
0,9
0,85
0,8
0,75
0,7
0,65
0,6
4
0,55
0,5
0,45
0,4
3
0,35
0,3
0,25
0,2
60
2
40
0,15
0,1
p
f
20
s
[
P
a
0,05
0
1
]
0
0
200
400
600
800
1.000
1.200
1.400
1.600
1.800
2.000
qv[m^3/h]
Measured values
Wired
U
f
n
Pe
I
qv
pfs
Pa
0
qv
pfs
V
Hz
60
60
60
60
min-1
2950
2850
2810
2805
W
A
m3/h
1870
1720
1485
1200
CFM
1100
1010
875
inH2O
0.00
0.20
0.40
0.56
1
2
3
4
Y
Y
Y
Y
400
400
400
400
160
177
184
184
0.26
0.28
0.29
0.29
50
100
140
705
Wired = Wiring · U = Power supply · f = Frequency · n = Speed (rpm) · Pe = Power consumption · I = Current draw · qv = Air flow · pfs = Pressure increase
Item no. 13665-5-9980 · ENU · Change 89188 · Approved 2016-04-28 · Page 6 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
相关型号: