8820B [EMCORE]
System 8000 Fiber-Optic Interfacility Links; 系统8000光纤设施间的相关链接型号: | 8820B |
厂家: | EMCORE CORPORATION |
描述: | System 8000 Fiber-Optic Interfacility Links |
文件: | 总19页 (文件大小:387K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Data Sheet, Rev. 0
March 6, 2003
System 8000 Fiber-Optic Interfacility Links
Designed to interface directly with earth station equipment, the multifaceted System 8000 interfacility link offers a wide
variety of unique, site-specific interconnectivity solutions for satellite earth stations.
Consisting of a high-performance, highly flexible fam-
ily of fiber-optic transmitter and receiver plug-ins,
Features
system 8000 allows both microwave and RF signals
to be transmitted over long distances through fiber-
n Single thread, 1:1, and 1:2 redundancy
n EIRP monitoring capability
n RS-232 or RS-485 serial interface
n RS-232 or RS-422 data link
n RFI/EMI immunity
optic cable, and thereby eliminates the need for
coaxial and waveguide interconnections. A fiber-
optic link between the control room and antenna site
allows for convenient remote monitoring and control
as well.
The system can be tailored for a wide range of trans-
mit/receive frequency bands and offers an extensive
selection of unique, site-specific interconnectivity
solutions for satellite earth stations, including:
n CE approved
Applications
n Configurable 19 in. x 3u (5.25 in.) equipment chas-
sis that includes redundant power supplies; redun-
dancy switching options: single thread, 1:1, and
1:2; and selectable serial interfaces, RS-232 or
RS-485.
n C-, extended C-, X-, and Ku-band earth stations
n IF and L-band IFLs
n Rain-fade site diversity
n Economical 70 MHz/140 MHz links for uplink
antenna remoting, downconverter output distribu-
tion, and intersite connections for backup or
antenna diversity.
Description
The system 8000 fiber-optic interfacility links repre-
sent a comprehensive and simplified approach to
satellite earth station signal management and con-
trol. Essentially, the system is designed to bring
microwave technology into the 21st Century by con-
verting microwave signals into continuously variable
amplitude-modulated optical signals.
n L-band links cover the 950 MHz—2050 MHz and
can be used for block downconverted C-, extended
C-, X-, or Ku-band signals, or for L-band Inmarsat
transmit and receive applications.
n C-, extended C-, X-, and Ku-band uplink and
downlink systems carry the main transmit and
receive signals between the control room and the
antenna site.
Data Sheet, Rev. 0
March 6, 2003
System 8000 Fiber-Optic Interfacility Links
Status information, including alarms and warnings, is
indicated by front panel LEDs and through standard
system monitor and control serial data ports on the
chassis rear panel.
Description (continued)
n Remote RF monitor links measure the composite
uplink signal at the uplink EIRP monitor coupler
located at the antenna’s input feed flange.
n Monitor and control data link provides a full-duplex,
fiber-optic path for either RS-232C or RS-422 data
for the earth station’s monitor and control system.
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso-
lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess
of those given in the operational sections of the data sheet. Exposure to absolute maximum ratings for extended
periods can adversely affect device reliability.
Parameter
Symbol
Min
Max
Unit
Operating Temperature Range
Storage Temperature Range
TC
Tstg
—
0
50
°C
°C
–20
+60
Power Requirements:
8001A Chassis With 8010A (Factory Set)
Status and Control Plug
Transmitter Plug-in
115/60
—
—
230/50
5
18
Vac/Hz
W
W
Receiver Plug-in
—
5.2
W
RF Input
RFIN
—
—
—
5
2
V
—
%
Surge Protection*
Humidity, Noncondensing
—
95
RH
*A 500 V transient developed across 100 pF is discharged through 1500 Ω to each connector pin without damaging the system.
Typical Block Diagram
As indicated in the block diagram below, the input and output amplifiers are integral to the system 8000. The tables
presented throughout the following sections, however, give the expected performance of each functional block in
the link with respect to their corresponding performance bands, including 70 MHz—140 MHz, L-band, and C-, X-,
and Ku-band interfacility links. These specifications, along with those for remote RF signal monitor interfacility links
and fiber-optic data links, are presented to aid in generating level diagrams for overall system analysis.
OUTPUT
AMP
INPUT
AMP
REDUNDANCY
SWITCHING UNIT (RSU)
REDUNDANCY
SWITCHING UNIT (RSU)
FIBEROPTIC LINK
RF IN
RF OUT
LOSS = 4 dB
NF = 4 dB
LOSS = 2 dB
NF = 2 dB
2
ORTEL a Division of EMCORE
Data Sheet, Rev. 0
March 6, 2003
System 8000 Fiber-Optic Interfacility Links
70 MHz/140 MHz Interfacility Link Specification
These links are designed to interconnect the up- and downconverters with the satellite modems or video exciters
and demodulators. They are specified to meet and exceed Intelsat requirements to 70 km. They are ideal for inter-
connections on site, to and from a diverse antenna site and for local access between a teleport and the end user.
The 70 MHz/140 MHz links are available as nonredundant or 1:1 redundant links only.
Table 1. 70 MHz/140MHz Interfacility Link Specification: 8603A Tx/8604A Rx, Options -001, -002, -050
Specification
Parameter
Symbol
—
Min
40
0
Typ
—
Max
200
30
Unit
MHz
dB
Passband
Optical Loss
LOPT
RFIN
G
—
Nominal RF Input at Max Input Gain
—
–22
—
dBm
Link Gain (–2 dB LOPT; –6 dB with Redundancy
Switching):
8603A/8604A
8603A-001/8604A-002
8603A-001/8604A
0
—
—
—
—
9
dB
dB
dB
dB
11
23
35
20
32
44
8603A-002/8604A-001
Flatness
—
—
—
—
—
±0.25/40
0.02
—
—
—
dB/MHz
dB/MHz
dB/hr
Gain Slope
Gain Stability at Constant Temperature
∆GT
NF
±0.15/24
Noise Figure at Max Input Gain
(Add 4 dB with Redundancy Switching):
8603A
—
—
—
—
—
—
25 (1)
38 (10)
28 (10)
34 (24)
37 (40)
52 (65)
—
—
—
—
—
—
dB (km)
dB (km)
dB (km)
dB (km)
dB (km)
dB (km)
8603A-001/8603A-002
Linearity (Third-Order Intermodulation Products
Max Input Gain, PIN = –27 dBm/Carrier for Two
Equilevel Carriers)
—
—
—
C/I = 60
—
dB
Group Delay:
Peak-to-Peak
Linear
—
—
—
1.0
0.05
0.015
—
—
—
ns
ns/MHz
ns/MHz2
Parabolic
Input/Output Impedance:
Standard
Z
—
—
75
50
—
—
Ω
Ω
Option 050
Input/Output VSWR
Spur-Free Dynamic Range*
RF Connector
—
SDFR
—
—
—
1.3:1
—
—
—
—
—
—
—
BNC
Optical Fiber
—
1310 nm, Single Mode
Optical Connector
—
FC/APC (Tight-fit Keying),
Return Loss > 60
—
dB
Absolute Maximum RF Input (Max Input Gain)
RFIN MAX
—
—
–5
dBm
2/3
* Spur-free dynamic range (SFDR) = 2/3(IP3 – NF + 173.8) dB/Hz ; IP3 = input third-order intercept, NF = noise figure. SFDR is the range
where the carrier is above the noise and the third IM is below the noise, C/I = 2x(IP3 – PIN), where PIN = input RF/carrier for two carriers.
3
ORTEL a Division of EMCORE
Data Sheet, Rev. 0
March 6, 2003
System 8000 Fiber-Optic Interfacility Links
70 MHz/140 MHz Interfacility Link Specification (continued),
Table 2. 70 MHz/140 MHz Interfacility Link: 8603A Tx and 8604A Rx, (0 km to 10 km)
Parameter
Symbol
Input Amp
Fiber-Optic Link Output Amp
System
Unit
8063A
8064A
(without RSU)
Min
Max
Typ
Typ
Min
Max
Gain
G
12
21
–33 – 2 LOPT
21
–2 LOPT 9 – 2 LOPT dB
Noise Figure
0 km
NF
17
—
—
8
—
—
—
45
59
4
—
—
—
34
47
—
25
38
dB
dB
dB
10 km
Output IP3
—
30
—
—
30
—
—
—
–1
–11
26
—
—
—
15
7
—
15
7
dB
dB
dB
0 km, 0.5 dB LOPT
10 km, 5 dB LOPT
Table 3. 70 MHz/140 MHz Interfacility Link: 8603A-001 Tx and 8604A-002 Rx (10 km to 30 km);
8603A-001 Tx and 8604A Rx (25 km to 45 km);
8603A-002 Tx and 8604A-001 Rx (45 km to 70km)
Paramete
Symbol Input Amp
Fiber-Optic Link
8063A-001/8603A-002
Fixed Output Amp
Typ
Unit
r
Min Max
Typ
8604A-002
8604A 8604A-001
Gain
G
12
17
21
8
–10 – 2 LOPT
9
4
21
4
33
4
dB
Noise Fig.
NF
48 55 54 59 57 71
(10) (30) (25) (45) (40) (65)
dB
(km)
OutPut IP3
—
30
8
26 – 2 LOPT
26
26
26
dBm
4
ORTEL a Division of EMCORE
Data Sheet, Rev. 0
March 6, 2003
System 8000 Fiber-Optic Interfacility Links
L-Band Interfacility Link Specifications
The L-band links can carry a downconverted C-, X-, or Ku-band polarization. They can also carry the L-band trans-
mit or receive signals for a satellite mobile communications feederlink station for systems such as Inmarsat. Each
link is designed to meet and exceed all of the requirements for use in Intelsat Standard A and C earth stations even
under the highest signal-loading conditions. The links are especially useful for routing signals to and from a diverse
antenna site. One fiber is used in single-strand links and two are used in 1:1 redundant paths. Optionally, the path
may share a fiber-optic link with another path in 1:2 redundant configurations.
Table 4: L-Band Interfacility Link Specifications: 8710A Tx and 8720A Rx
Specification
Parameter
Symbol
—
Min
950
—
Typ
—
Max
2050
—
Unit
MHz
dB
Passband
Optical Loss Budget
LOPT
RFIN
G
>6
Nominal RF Input at Max Input Gain
Link Gain (–6 dB with Redundancy Switching)
Flatness
—
–30
—
—
dBm
dB
–10
17
—
—
—
±0.2/48
±1.0/500
—
—
dB/MHz
dB/MHz
Gain Slope
—
∆GT
NF
—
—
—
0.02
±0.15/24
20
—
—
—
dB/MHz
dB/hr
dB
Gain Stability at Constant Temperature
Noise Figure at Max Input Gain
(Add 4 dB with Redundancy Switching)
dB/Hz2/3
Spur-Free Dynamic Range*
SDFR
—
—
96
—
Group Delay:
Peak-to-Peak
Linear
—
—
—
0.5
0.02
0.01
—
—
—
ns
ns/MHz
ns/MHz2
Parabolic
Input/Output Impedance
Input/Output VSWR
RF Connector
Z
—
—
50
—
—
Ω
—
—
—
—
—
—
—
1.5:1
N Jack
Optical Fiber
1310 nm, Single Mode
Optical Connector
FC/APC (Tight-fit Keying),
Return Loss > 60
—
dB
Absolute Maximum RF Input (Max Input Gain)
RFIN MAX
—
—
–15
dBm
2/3
* Spur-free dynamic range (SFDR) = 2/3(IP3 – NF + 173.8) dB/Hz ; IP3 = input third-order intercept, NF = noise figure. SFDR is the range
where the carrier is above the noise and the third IM is below the noise, C/I = 2x(IP3 – PIN), where PIN = input RF/carrier for two carriers.
Typical L-Band Performance
Table 5. L-Band Interfacility Link Specifications: 8710ATx and 8720A (6 dB Optical Loss Budget)
Parameter
Symbol
Input Amp
Fiber-Optic
Link
Output Amp
System
(without RSU)
Unit
Min
Max
Typ
Min
Max
15
Min
Max
Gain
G
NF
—
15
17
28
30
8
–22
48
8
0
–7
34
3
23
19
19
dB
dB
Noise Figure
Output TOI
13
16
7
31
27
dBm
5
ORTEL a Division of EMCORE
Data Sheet, Rev. 0
March 6, 2003
System 8000 Fiber-Optic Interfacility Links
C-Band, Extended C-Band, X-Band, and Ku-Band Interfacility Link Specifications
These links carry the main transmit and receive signals between the equipment room and the antenna site. Each
fiber-optic path carries one entire polarization. One fiber is used in single strand links and two are used in 1:1
redundant paths. Or, the path may share a fiber-optic link with another path in 1:2 redundant configurations. Each
link is designed to meet and exceed all of the requirements for use in Intelsat Standard A earth stations, even
under conditions of heaviest signal loading.
Typical C-Band Performance
Table 6. C-, Extended C-, X-, and Ku-Band Interfacility Link Specifications: Uplink Path, 8810A Tx/8820A
Rx;
Downlink Path, 8810B Tx/8820B Rx
Specification
Typ
Parameter
Symbol
Min
Max
Unit
Passband:
8810A Tx/8820A Rx
—
5.845
5.845
3.6
—
—
—
—
6.425
6.725
4.2
GHz
GHz
GHz
GHz
8810A-E08 Tx/8820A-E03
8810B Tx/8820B Rx
8810B-E05 Tx/8820B-E06
3.4
4.2
Optical Loss Budget:
1310 nm
LOPT
RFIN
G
—
—
6
12
—
—
dB
dB
1550 nm
Nominal RF Input at Max Input Gain:
8810A Tx/8820A Rx
—
—
–15
–30
—
—
dBm
dBm
8810B Tx/8820B Rx
Link Gain (–6 dB With Redundancy Switching):
8810A Tx/8820A Rx
–13
–11
—
—
7
14
dB
dB
8810B Tx/8820B Rx
Flatness
—
—
—
±0.2/48
±0.7/500
—
—
dB/MHz
dB/MHz
Gain Slope
—
∆GT
NF
—
—
0.02
—
—
dB/MHz
dB/hr
Gain Stability at Constant Temperature
±0.15/24
Noise Figure at Max Input Gain
(Add 4 dB with Redundancy Switching):
8810A Tx/8820A Rx
—
—
32
20
—
—
dB
dB
8810B Tx/8820B Rx
Spur-Free Dynamic Range:*
8810A Tx/8820A Rx
SDFR
—
dB/Hz2/3
dB/Hz2/3
—
—
98
96
—
—
8810B Tx/8820B Rx
Group Delay:
Peak-to-Peak
Linear
—
—
—
0.5
0.02
0.01
—
—
—
ns
ns/MHz
ns/MHz2
Parabolic
Input/Output Impedance
Input/Output VSWR
Z
—
—
50
—
—
Ω
—
1.35:1
—
2/3
* Spur-free dynamic range (SFDR) = 2/3(IP3 – NF + 173.8) dB/Hz ; IP3 = input third-order intercept, NF = noise figure. SFDR is the range
where the carrier is above the noise and the third IM is below the noise, C/I = 2x(IP3 – PIN), where PIN = input RF/carrier for two carriers.
6
ORTEL a Division of EMCORE
Data Sheet, Rev. 0
March 6, 2003
System 8000 Fiber-Optic Interfacility Links
C-Band, Extended C-Band, X-Band, and Ku-Band Interfacility Link Specifications
(continued)
Typical C-Band Performance (continued)
Table 6. C-, Extended C-, X-, and Ku-Band Interfacility Link Specifications: Uplink Path, 8810A Tx/8820A
Rx;
Downlink Path, 8810B Tx/8820B Rx (continued)
Specification
Parameter
RF Connector
—
N Jack
—
Typ†
Symbol
Min
Max
Unit
Optical Wavelength:
—
λ
8810A Tx/8820A Rx
8810A-E08 Tx/8820A-E03
8810B Tx/8820B Rx
8810B-E05 Tx/8820B-E06
8810A-E03 Tx/8820A Rx
8810A-E03 Tx/8820A-E03
8810B-E04 Tx/8820B Rx
8810B-E04 Tx/8820B-E06
—
—
—
—
—
—
—
—
1310
1310
1310
1310
1550
1550
1550
1550
—
—
—
—
—
—
—
—
nm
nm
nm
nm
nm
nm
nm
nm
Optical Connector
—
FC/APC (Tight-fit Keying),
Return Loss > 60
—
dB
Absolute Maximum RF Input (Max Input Gain):
8810A Tx/8820A Rx
RFIN MAX
—
—
—
—
5
–10
dBm
dBm
8810B Tx/8820B Rx
2/3
* Spur-free dynamic range (SFDR) = 2/3(IP3 – NF + 173.8) dB/Hz ; IP3 = input third-order intercept, NF = noise figure. SFDR is the range
where the carrier is above the noise and the third IM is below the noise, C/I = 2x(IP3 – PIN), where PIN = input RF/carrier for two carriers.
† Single-mode fiber.
Table 7. C-Band Uplink Specifications: 8810A Tx and 8720A Rx (6 dB Optical Loss Budget)
Parameter
Symbol
Input Amp
Fiber-Optic
Link
Output Amp
System
(without RSU)
Unit
Min
Max
Typ
Min
Max
17
Min
Max
Gain
G
NF
—
3
13
15
24
–23
43
1
7
–13
42
5
7
dB
dB
dB
Noise Figure
Output TOI
23
24
16
20
10
24
31
14
Table 8. C-Band Downlink Specifications: 8810B Tx and 8820B Rx (6 dB Optical Loss Budget)
Parameter
Symbol
Input Amp
Fiber-Optic
Link
Output Amp
System
(without RSU)
Unit
Min
Max
Typ
Min
Max
10
Min
Max
Gain
G
NF
—
12
26
24
27
14
24
–23
43
1
0
–11
34
14
19
7
dB
dB
dB
Noise Figure
Output TOI
16
14
10
207
–2
7
ORTEL a Division of EMCORE
Data Sheet, Rev. 0
March 6, 2003
System 8000 Fiber-Optic Interfacility Links
C-Band, Extended C-Band, X-Band, and Ku-Band Interfacility Link Specifications
(continued)
Typical C-Band Performance (continued)
Table 9. Sample Link Analysis: Downlink GT
Table 10. Sample Link Analysis: Fiber-Optic IFL
Contribution to Uplink Path EIRP
Parameter
Specifica-
tion
Unit
Parameter
Specifi-
cation
Unit
Frequency
4.0
GHz
Frequency
6.0
4
GHz
—
dBW/m2
Total Power Flux Density
–117.3
Number of Channels
Channel Noise Bandwidth
IFL RF Input/Channel
Fiber-optic IFL Gain
Fiber-optic IFL Noise Figure
IFL Output IP3
Antenna Diameter
18
74
m
32
MHz
Antenna Efficiency
Antenna Temperature
Feed Loss
%
–15
3.4
34
dBm
65
°K
dBm
0.15
50
dB
LNA Gain
dB
dB
LNA Temperature
35
°K
13
dBm
Cable Loss into IFL
Total Power into IFL
Fiber-optic IFL Gain
Fiber-optic IFL Noise Figure
IFL Two-Tone Third IM
Output Loss (Splitter)
Downconverter Input Channel
Downconverter Noise Figure
System G/T
4
dB
Cable Loss
8.0
18
dB
–20.5
5.2
dBm
dBm
dB
Antenna Diameter
Antenna Gain
m
59.6
88
dB
26.4
–51.4
12
EIRP/Channel
dBW
dBW/4 kHz
dBW/4 kHz
dBc
dB
Noise EIRP
–1.2
5.4
IM EIRP
–39.2
17
dBm
dB
34.32
34.43
dB/°K
dB/°K
G/T Without Fiber-optic IFL
8
ORTEL a Division of EMCORE
Data Sheet, Rev. 0
March 6, 2003
System 8000 Fiber-Optic Interfacility Links
C-Band, Extended C-Band, X-Band, and Ku-Band Interfacility Link Specifications
(continued)
Typical X-Band Performance (continued)
Table 11. X-Band Interfacility Link Specifications: 8850A Tx and 8860A Rx
Specification
Parameter
Symbol
—
Min
7.25
—
Typ
—
Max
8.40
—
Unit
GHz
dB
Passband
Optical Loss Budget
LOPT
RFIN
G
6
Nominal RF Input at Max Input Gain
Link Gain (–6 dB with Redundancy Switching)
Flatness
—
–30
—
—
dBm
dB
–9
11
—
—
—
±0.25 /48
±0.75/500
—
—
dB/MHz
dB/MHz
Gain Slope
—
∆GT
NF
—
—
—
≤0.02
±0.15/24
26
—
—
—
dB/MHz
dB/hr
dB
Gain Stability at Constant Temperature
Noise Figure at Max Input Gain
(Add 4 dB with Redundancy Switching)
dB/Hz2/3
Spur-Free Dynamic Range*
SDFR
—
—
92
—
Group Delay:
Peak-to-Peak
Linear
—
—
—
0.5
0.02
0.01
—
—
—
ns
ns/MHz
ns/MHz2
Parabolic
Input/Output Impedance
Input/Output VSWR
RF Connector
Z
—
—
50
—
—
Ω
—
—
—
—
—
—
—
1.35:1
N Jack
Optical Fiber
1310 nm, single mode
Optical Connector
FC/APC (Tight-fit Keying),
Return Loss > 60
—
dB
Absolute Maximum RF Input (Max Input Gain)
RFIN MAX
2/3
—
—
–15
dBm
* Spur-free dynamic range (SFDR) = 2/3(IP3 – NF + 173.8) dB/Hz ; IP3 = input third-order intercept, NF = noise figure. SFDR is the range
where the carrier is above the noise and the third IM is below the noise, C/I = 2x(IP3 – PIN), where PIN = input RF/carrier for two carriers.
9
ORTEL a Division of EMCORE
Data Sheet, Rev. 0
March 6, 2003
System 8000 Fiber-Optic Interfacility Links
C-Band, Extended C-Band, X-Band, and Ku-Band Interfacility Link Specifications
(continued)
Typical X-Band Performance (continued)
Table 12. X-Band Specifications: 8850A Tx and 8860A Rx (6 dB Optical Loss Budget)
Parameter
Symbol
Input Amp
Fiber-Optic
Link
Output Amp
System
(without RSU)
Unit
Min
Max
Typ
Min
Max
18
Min
Max
Gain
G
NF
—
20
18
26
30
10
25
–43
55
8
–15
36
5
dB
dB
dB
Noise Figure
Output TOI
8
6
26
–2
–18
15
21
–7
Table 13. Sample Link Analysis: Downlink GT
Parameter
Specification
Unit
Frequency
7.75
GHz
dBW/m2
Total Power Flux Density
–120
Antenna Diameter
11.6
70
m
Antenna Efficiency
Antenna Temperature
Feed Loss
%
30
°K
0.2
dB
LNA Gain
50
dB
LNA Temperature
50
°K
Cable Loss into IFL
Total Power into IFL
Fiber-optic IFL Gain
Fiber-optic IFL Noise Figure
IFL Two-Tone Third IM
Output Loss (Splitter)
Downconverter Input Channel
Downconverter Noise Figure
System G/T
6
dB
–2.9
11.5
25.1
–44.1
NA
dBm
dBm
dB
dBc
—
–28.3
17
dBm
dB
37.37
37.53
dB/°K
dB/°K
G/T Without Fiber-optic IFL
10
ORTEL a Division of EMCORE
Data Sheet, Rev. 0
March 6, 2003
System 8000 Fiber-Optic Interfacility Links
C-Band, Extended C-Band, X-Band, and Ku-Band Interfacility Link Specifications
(continued)
Typical Ku-Band Performance (continued)
Table 14. Ku-Band Interfacility Link Specifications: Uplink Path, 8910A Tx/ 8920A Rx;
Downlink Path, 8910B Tx/ 8920B Rx
Specification
Typ
Parameter
Symbol
Min
Max
Unit
Passband:
—
Uplink,8910A Tx/8920A Rx
Downlink,8910B Tx/8920B Rx
Downlink,8910B-E01 Tx/8920B-E01 Rx
14.0
10.95
10.7
—
—
—
14.5
12.75
12.75
GHz
GHz
GHz
Optical Loss Budget
LOPT
RFIN
—
6
—
dB
Nominal RF Input at Max Input Gain:
8910A Tx/8920A Rx
—
—
–30
–30
—
—
dBm
dBm
8910B Tx/8920B Rx
Link Gain (–6 dB with Redundancy Switching):
8910A Tx/8920A Rx
G
–9
–16
—
—
11
11
dB
dB
8910B Tx/8920B Rx
Flatness
—
—
—
±0.2/48
±0.7/500
—
—
dB/MHz
dB/MHz
Gain Slope
—
∆GT
NF
—
—
0.02
—
—
dB/MHz
dB/hr
Gain Stability at Constant Temperature
±0.15/24
Noise Figure at Max Input Gain
(Add 4 dB with Redundancy Switching):
8910A Tx/8920A Rx
—
—
25
25
—
—
dB
dB
8910B Tx/8920B Rx
Spur-Free Dynamic Range:*
8910A Tx/8920A Rx
SDFR
—
dB/Hz2/3
dB/Hz2/3
—
—
94
94
—
—
8910B Tx/8920B Rx
Group Delay:
Peak-to-Peak
Linear
—
—
—
0.5
0.02
0.01
—
—
—
ns
ns/MHz
ns/MHz2
Parabolic
Input/Output Impedance
Input/Output VSWR
RF Connector
Z
—
—
50
—
—
Ω
—
—
—
—
—
—
—
1.35:1
SMA
Optical Fiber
1310 nm, Single Mode
Optical Connector
FC/APC (Tight-fit Keying),
Return Loss > 60
—
dB
Absolute Maximum RF Input (Max Input Gain)
RFIN MAX
2/3
—
—
–15
dBm
* Spur-free dynamic range (SFDR) = 2/3(IP3 – NF + 173.8) dB/Hz ; IP3 = input third-order intercept, NF = noise figure. SFDR is the range
where the carrier is above the noise and the third IM is below the noise, C/I = 2x(IP3 – PIN), where PIN = input RF/carrier for two carriers.
11
ORTEL a Division of EMCORE
Data Sheet, Rev. 0
March 6, 2003
System 8000 Fiber-Optic Interfacility Links
C-Band, Extended C-Band, X-Band, and Ku-Band Interfacility Link Specifications
(continued)
Typical Ku-Band Performance (continued))
Table 15. Ku-Band Interfacility Link Specifications: Uplink Path, 8910A Tx/ 8920A Rx
(6 dB Optical Loss Budget)
Parameter
Symbol
Input Amp
Fiber-Optic
Link
Output Amp
System
(without RSU)
Unit
Min
Max
Typ
Min
Max
18
Min
Max
Gain
G
NF
—
20
18
26
30
10
25
–37
55
8
–9
36
–5
11
25
4
dB
dB
dB
Noise Figure
Output TOI
8
6
–8
15
21
Table 16. Ku-Band Interfacility Link Specifications: Uplink Path, 8910B Tx/ 8920B Rx
(6 dB Optical Loss Budget)
Parameter
Symbol
Input Amp
Fiber-Optic
Link
Output Amp
System
(without RSU)
Unit
Min
Max
Typ
Min
Max
18
Min
Max
Gain
G
NF
—
15
22
26
30
10
25
–37
55
8
–14
42
11
25
4
dB
dB
dB
Noise Figure
Output TOI
8
6
–8
15
21
–5
Table 17. Sample Link Analysis: Downlink G/T
Table 18. Sample Link Analysis: Fiber-Optic IFL
Contribution to Uplink Path EIRP
Parameter
Specifica-
tion
Unit
Parameter
Specifi-
cation
Unit
Frequency
11.2
GHz
Frequency
14.0
4
GHz
—
dBW/m2
Total Power Flux Density
–116
Number of Channels
Channel Noise Bandwidth
IFL RF Input/Channel
Fiber-optic IFL Gain
Fiber-optic IFL Noise Figure
IFL Output IP3
Antenna Diameter
10
74
m
32
MHz
dBm
dBm
dB
Antenna Efficiency
Antenna Temperature
Feed Loss
%
–25
5.3
31.0
5.7
8.0
77.0
11
48
°K
0.15
50
dB
LNA Gain
dB
dBm
dB
LNA Temperature
70
°K
Cable Loss
Cable Loss into IFL
Total Power into IFL
Fiber-optic IFL Gain
Fiber-optic IFL Noise Figure
IFL Two-Tone Third IM
Output Loss (Splitter)
Downconverter Input Channel
Downconverter Noise Figure
System G/T
3
dB
HPA Gain
dB
–22.7
5.9
dBm
dBm
dB
Antenna Diameter
Antenna Gain
m
62.6
82
dB
30.4
–51.0
8
EIRP/Channel
dBW
dBW/4 kHz
dBW/4 kHz
dBc
dB
Noise EIRP
0.0
–0.6
IM EIRP
–27.8
17
dBm
dB
37.9
38.1
dB/°K
dB/°K
G/T without Fiber-optic IFL
12
ORTEL a Division of EMCORE
Data Sheet, Rev. 0
March 6, 2003
System 8000 Fiber-Optic Interfacility Links
Remote RF Signal Monitor Interfacility Link Specifications
These links bring the uplink RF test ports located at the antenna site back to the equipment room or control room.
This permits the operator to monitor the composite transmitted RF signals conveniently, quickly, and reliably with-
out having to go to the antenna site or invest in a spectrum analyzer for every antenna site. In applications where
the system 8000 is being used for the main signal paths, these links can be included as plug-ins in the main chas-
sis. Or, the uplink RF monitor links can be added to an existing earth station with all the output ports in one chassis
in the control room.
Table 19. RF Signal Monitor Interfacility Link Specifications: C-Band, 8483A Tx; Ku-Band 8493A Tx
Specification
Typ
Parameter
Symbol
Min
Max
Unit
Passband:
C-Band, 8483A Tx
Ku-Band 8493A Tx
Optical Loss Budget
Nominal Input Power
—
5.845
14.0
—
—
6.725
14.5
GHz
GHz
LOPT
PIN
LL
—
—
6
5
—
—
dB
dBm
Link Loss:*
C-Band, 8483A Tx
Ku-Band, 8493A Tx
10
15
—
—
20
25
dB
dB
Flatness
—
—
—
±0.2/48
±0.7/500
—
—
dB/MHz
dB/MHz
Gain Slope
—
∆GT
NF
—
—
0.02
—
—
dB/MHz
dB/hr
Gain Stability at Constant Temperature
±0.15/24
Noise Figure:
C-Band, 8483A Tx
Ku-Band, 8493A Tx
—
—
48
55
—
—
dB
dB
Linearity
—
Input IP3:
dBm
dBm
C-Band, 8483A Tx
Ku-Band, 8493A Tx
Input 1 dB Compression Point:
C-Band, 8483A Tx
Ku-Band, 8493A Tx
—
—
30
28
—
—
dBm
dBm
—
—
18
18
—
—
Group Delay:
Peak-to-Peak
Linear
—
—
—
—
0.5
0.02
0.01
—
—
—
ns
ns/MHz
ns/MHz2
Parabolic
Input/Output Impedance
Input/Output VSWR
Z
—
—
50
—
—
Ω
—
—
1.35:1
—
RF Connector:
C-Band, 8483A Tx
Ku-Band 8493A Tx
N Jack
SMA Jack
—
—
Optical Fiber
—
—
1310 nm, Single Mode
—
Optical Connector
FC/APC (Tight-fit Keying), Return
Loss > 60
—
dB
Absolute Maximum RF Input (Max Input Gain)
RFIN MAX
—
—
–18
dBm
*Adjustable at output.
13
ORTEL a Division of EMCORE
Data Sheet, Rev. 0
March 6, 2003
System 8000 Fiber-Optic Interfacility Links
Fiber-Optic Data Link Specifications
These plug-ins can be added to the System 8000 chassis to provide a full duplex data path connecting the M and
C computer terminals at the antenna site and the equipment room. The standard version is for RS-422 serial data
with an option for RS-232. This link provides a data path only; there is no hand shaking, so a modem must be used
at each computer.
Table 20. Fiber-optic Data Link Specifications: 8501A Tx and Transceiver
18501A
Transceiver
Specification
Parameter
Bit Error Rate
Specification
Unit
Parameter
Unit
≤10-9
—
Optical Connector
FC/APC, 1310 nm,
single mode
—
Operating Mode
Asynchronous,
Full Duplex
—
Optical Loss
Budget
6
dB
Data Rate:
RS-422
I/O Logic Levels RS-422A:
Standard Balanced/Terminated, 120 Ω
200
19.2
kbits/s
kbits/s
RS-232
Differential I/O Range:
VMIN ±1 to VMAX ±6
V
RS-232:
Single-ended, Unbalanced,
Nonterminated; I/O Range:
VMIN ± 4 to VMAX ± 12
—
V
Connector
DB-9S
>0.5
—
(Chassis Rear Panel)
Transmitter Optical Out-
put Power
mW
14
ORTEL a Division of EMCORE
Data Sheet, Rev. 0
March 6, 2003
System 8000 Fiber-Optic Interfacility Links
the backup link. If the fiber-optic cable containing the
fiber for the primary link is broken, the fiber-optic
receiver detects loss of received optical power and the
output is switched to the other channel. The switching
due to receiver failure works independently of the
external monitoring and control (M and C) system only
for the 1:1 configuration. For the 1:2 version, the exter-
nal M and C must switch the input to the backup trans-
mitter.
System 8000 Redundancy
System 8000 provides multiple redundancy options.
The standard offerings are single thread, 1:1, and 1:2.
The 1:1 and 1:2 configurations offer two modes of
redundancy switching: automatic and manual.
Automatic Mode
In this mode, internal sensing and control provides
automatic switching to the backup link in case of any
failure in the optical system. If the laser temperature
alarm or laser optical power alarm is detected at the
fiber-optic transmitter, the faulty transmitter is shut off.
In the 1:2 redundancy scheme, if these conditions are
detected, the switch position is changed to select the
backup link. The fiber-optic receiver then detects loss
of received optical power and the output is switched to
Manual Mode
When this mode is selected, automatic switching to the
backup link is turned off. This mode can be selected
remotely through the M and C system or it can be
selected locally by pressing the auto-off button on the
front panel of the status and control plug-in on the
chassis.
Figure 1. System 8000 Redundancy Mode Configurations
ORTEL a Division of EMCORE
15
Data Sheet, Rev. 0
March 6, 2003
System 8000 Fiber-Optic Interfacility Links
General Specifications
Alarms and Warnings
Alarms and warnings are indicated on the plug-in front panel by LED annunciators. Alarms are displayed in red,
warnings in yellow. Both alarms and warnings are reported to the remote interface.
Power supply faults are indicated on the front panel by red annunciators and are reported to the remote interface.
The chassis configuration is continuously reported to the remote interface.
Table 21. Alarms and Warnings Descriptions
Transmitter Plug-ins
Annunciator Readout
Color
Power On
Green (normally on)
Opt Pwr Lo
Laser Temp
RF Pwr Lo
Power On
Red
Red
Yellow
Green (normally on)
Red
Receiver Plug-ins
Opt Pwr Lo
Output Pwr Hi
RF Pwr Lo
Yellow
Yellow
Power Requirements
Table 22. Power requirements
System/Component
Specification
Unit
8001A Chassis with 8010A (Factory Set)
Status and Control Plug-in
Transmitter Plug-in
115/230, 50—60
Vac, Hz
5
18
5.2
W
W
W
Receiver Plug-in
General Dimensions
Table 23. General Dimensions
Parameter
Specification
Weight:
8000A Chassis (includes two power supplies and status and control)
Transmitter and Receiver Plug-in
27 lbs. net; 30 lbs, shipping
3 lbs. net; 4 lbs. shipping
Dimensions:
Standard Rack-mountable
19 in. W x 5.25 H x 19.5 in. D
(48.26 cm W x 13.34 cm H x 49.53 cm D)
16
ORTEL a Division of EMCORE
Data Sheet, Rev. 0
March 6, 2003
System 8000 Fiber-Optic Interfacility Links
Outline Diagram
Laser Safety Information
Class IIIb Laser Product
FDA/CDRH Class IIIb laser product. All transmitter versions are Class IIIb laser products per CDRH, 21 CFR 1040
Laser Safety requirements. All transmitter versions are Class 3B laser products per IEC* 60825-1:1993. The
devices have been classified with the FDA under an accession number to be determined.
This product complies with 21 CFR 1040.10 and 1040.11.
Wavelength = 1.3 µm.
Maximum power = 30 mW.
Caution: Use of controls, adjustments, and procedures other than those specified herein may result in
hazardous laser radiation exposure.
* IEC is a registered trademark of The International Electrotechnical Commission.
DANGER
INVISIBLE LASER RADIATION
IS EMITTED FROM THE END
OF FIBER OR CONNECTOR
Avoid direct exposure to beam
Do not view beam directly with
optical instruments
INVISIBLE LASER RADIATION EMITTED FROM END OF FIBER OR CONNECTOR
Avoid exposure to beam
Class 3B Laser Product IEC-60825M 1993 Max. Output: 30 mW
Wavelength: 1.3 µm
17
ORTEL a Division of EMCORE
Data Sheet, Rev. 0
March 6, 2003
System 8000 Fiber-Optic Interfacility Links
Ordering Information
Table 24. Ordering Information
Device
Description
Model Number
System 8000:
Mainframe
8000A
8001A
8009A
Chassis
—
—
—
—
Main Power Supply
Standby Power Supply
Status and Control RS232 or RS485
8009B
8010B-RS232 or RS485
Accessory Kit
Includes 6 dB optical
8050A, 6 dB
attenuators, installation
software, and optical con-
nector cleaning kit (other
attenuation values avail-
able upon request)
Ku-Band, 8900 Series:
Uplink Transmitter
Uplink Receiver
14.0 GHz—14.5 GHz
14.0 GHz—14.5 GHz
10.7 GHz—12.75 GHz
10.7 GHz—12.75 GHz
8910A
8920A
8910B
8920B
Downlink Transmitter
Downlink Receiver
X-Band, 8800 Series:
Transmitter
7.25 GHz—8.4 GHz
7.25 GHz—8.4 GHz
8850A
8860A
Receiver
C-Band, 8800 Series:
Uplink Transmitter
Uplink Receiver
5.485 GHz—6.725 GHz
5.485 GHz—6.725 GHz
3.4 GHz—4.2 GHz
8810A
8820A
8810B
8820B
Downlink Transmitter
Downlink Receiver
3.4 GHz—4.2 GHz
L-Band, 8700 Series:
Transmitter (Uplink and Downlink)
Receiver (Uplink and Downlink)
950 MHz—2050 MHz
950 MHz—2050 MHz
8710A
8720A
70 MHZ—140 MHz, 8600 Series:
70/140 MHz Transmitter:
High Performance
High Performance
75 Ω
75 Ω
10 km—40 km
40 km—70 km
8603A
Option 001
Option 002
Option 050
8604A
Option 001
Option 002
Option 050
—
75 Ω
—
—
—
70/140 MH Receiver:
High Gain
Low Gain
50 Ω
Remote RF Signal Monitor, 8400 Series:
Ku-band Signal Monitor Tx (Use with Standard
Ku-band Uplink Receiver)
14.0 GHz—14.5 GHz
8493A
8483A
C-band Signal Monitor Tx 8483a
5.485 GHz—6.425 GHz
(Use With Standard C-band Uplink Receiver)
Fiber-optic Data Link:
RS-422, Standard
RS-232, Optional
—
—
8501A
Option 001
18
ORTEL a Division of EMCORE
Data Sheet, Rev. 0
March 6, 2003
System 8000 Fiber-Optic Interfacility Links
Related Documentation
Table 25. Related Documentation
Description
Document Number
System 8000 Fiber-Optic Interfacility Links Application Note
AP01-003OPTO
19
Agere Systems Inc.
相关型号:
8820DFF1-02
Monitor TEE DC Block, 500MHz Min, 2500MHz Max, 0.5dB Insertion Loss-Max, ROHS COMPLIANT PACKAGE
APITECH
8820DFF1-04
Monitor TEE DC Block, 10MHz Min, 4000MHz Max, 1.5dB Insertion Loss-Max, ROHS COMPLIANT PACKAGE
APITECH
8820DFF1-06
Monitor TEE DC Block, 10MHz Min, 6000MHz Max, 1.5dB Insertion Loss-Max, ROHS COMPLIANT PACKAGE
APITECH
8820DFF1-07
Monitor TEE DC Block, 10MHz Min, 7500MHz Max, 2dB Insertion Loss-Max, ROHS COMPLIANT PACKAGE
APITECH
8820DFF2-02
Monitor TEE DC Block, 500MHz Min, 2500MHz Max, 0.5dB Insertion Loss-Max, ROHS COMPLIANT PACKAGE
APITECH
8820DFF2-04
Monitor TEE DC Block, 10MHz Min, 4000MHz Max, 1.5dB Insertion Loss-Max, ROHS COMPLIANT PACKAGE
APITECH
8820DFF2-06
Monitor TEE DC Block, 10MHz Min, 6000MHz Max, 1.5dB Insertion Loss-Max, ROHS COMPLIANT PACKAGE
APITECH
8820DFF2-07
Monitor TEE DC Block, 10MHz Min, 7500MHz Max, 2dB Insertion Loss-Max, ROHS COMPLIANT PACKAGE
APITECH
8820DFF3-02
Monitor TEE DC Block, 500MHz Min, 2500MHz Max, 0.5dB Insertion Loss-Max, ROHS COMPLIANT PACKAGE
APITECH
8820DFF3-04
Monitor TEE DC Block, 10MHz Min, 4000MHz Max, 1.5dB Insertion Loss-Max, ROHS COMPLIANT PACKAGE
APITECH
8820DFF3-06
Monitor TEE DC Block, 10MHz Min, 6000MHz Max, 1.5dB Insertion Loss-Max, ROHS COMPLIANT PACKAGE
APITECH
8820DFF3-07
Monitor TEE DC Block, 10MHz Min, 7500MHz Max, 2dB Insertion Loss-Max, ROHS COMPLIANT PACKAGE
APITECH
©2020 ICPDF网 联系我们和版权申明