BXA30-48D15J [EMERSON-NETWORKPOWER]
Designed to meet telecom power supply interface standard ETS300-132-2; 专为满足通信电源接口标准ETS300-132-2型号: | BXA30-48D15J |
厂家: | EMERSON NETWORK POWER |
描述: | Designed to meet telecom power supply interface standard ETS300-132-2 |
文件: | 总5页 (文件大小:343K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Embedded Power for
Business-Critical Continuity
Rev.12.17.07
bxa30
1 of 5
BXA30 Series
Single and dual output
Total Power:
30W
Input Voltage: 9 - 18VDC
36 - 75VDC
# of Outputs: Single, dual
The BXA30 series, comprising 9 different models, has been
conceived as an applications-specific range of dc-dc converters,
specifically addressing telecommunications, industrial electronics,
test equipment, mobile telecommunications and distributed
power applications. The series offers three wide input voltage
ranges, 9 Vdc to 18 Vdc and 36 Vdc to 75 Vdc, and is available in
single and dual output versions. Designed to meet ETSI telecoms
interface standards ETS300-132-2 and BTR2511, together with
internal filtering to EN55022 level A, safety approval to EN60950
and UL1950, and isolation of 1500 Vdc, the 48 Vdc models are
ideal for telecommunications applications. The 12 V models are
particularly suited to industrial, mobile telecom and test
equipment applications, featuring EN61000-4-2, -3, -4, -5 and -6
immunity compliant. Other features include low output ripple,
overvoltage protection, continuous short circuit protection,
remote enable and remote sense.
Special Features
• Designed to meet telecom
power supply interface
standard ETS300-132-2
• UL, VDE and CSA
safety approvals
• VDE0878 and EN55022
conducted emissions level A
• EN61000-4-2, -3, -4, -5, -6
immunity compliant
• Fixed frequency operation at
350 kHz
• MTBF in excess of 7,005,000
hours (demonstrated)
• Basic insulation system
• Available RoHS compliant
• 2 year warranty
Safety
VDE0805/EN60950/IEC950
File No. 14501-3336-7006
Licence No. 6231
UL1950 File No. E174104
CSA C22.2 No. 950
File No. LR41062C
Embedded Power for
Business-Critical Continuity
Rev.12.17.07
bxa30
Specifications
2 of 5
All specifications are typical at nominal input, full load at 25°C unless otherwise stated.
OUTPUT SPECIFICATIONS
Voltage adjustability
Line regulation
EMC CHARACTERISTICS
Singles
10ꢀ
0.2ꢀ/ 0.4ꢀ
0.2ꢀ/ 0.4ꢀ
Conducted emissions
EN55022, FCC part 15 (Note 4)
Level A
Level B
Level A
Level A
EN55022, FCC part 15 (Note 5)
VDE0878 (Note 4) (48 V)
EN55022, FCC part 15
LL to HL (single/dual)
FL to NL (single/dual)
Radiated emissions
ESD air
ESD contact
Load regulation
EN61000-4-2, level 3
EN61000-4-2, level 4
EN61000-4-5, level 3
EN61000-4-4, level 3
EN61000-4-3, level 3
EN61000-4-6, level 3
Perf. criteria 2
Perf. criteria 2
Perf. criteria 2
Perf. criteria 2
Perf. criteria 2
Perf. criteria 2
Ripple and noise
(20 MHz bandwidth)
3.3 V
5.0 V
All others
All models
60 mV pk-pk
50 mV pk-pk
100 mV pk-pk
20 mV rms
Surge
Fast transients
Radiated immunity
Conducted immunity
Temperature coefficient
Overvoltage protection
Short circuit protection
0.02ꢀ/°C
GENERAL SPECIFICATIONS
Transient
135ꢀ Vout
Efficiency
See table
Singles
Duals (single short)
Continuous
(See BXA15/30
Design Note 100)
Continuous
Isolation voltage
Basic insulation
Input/output
input/case, 48 V models
1500 Vdc
1500 Vdc
Duals (dual short)
25ꢀ to 100ꢀ load
Switching frequency
Fixed
350 kHz
Transient response
Voltage accuracy
4.0ꢀ
1.5ꢀ
3.0ꢀ
Approvals and
standards
(See Note 12)
VDE0805, EN60950
IEC950, UL1950
CSA C22.2 No. 950
Load cross regulation
Dual output
30ꢀ to 100ꢀ output variation
Case material
Aluminum substrate
with plastic case
INPUT SPECIFICATIONS
Input voltage range
Material flammability
Weight
UL94V-0
120 g (4.24 oz)
7,005,000 hours
12 Vin nominal
48 Vin nominal
9-18 Vdc
36-75 Vdc
MTBF (See Note 9)
Demonstrated @ 25 °C
Reverse voltage
Yes
protection (See Note 7)
ENVIRONMENTAL SPECIFICATIONS
Max. input rise and
fall time
48 V
5 V/ms
ETS300-132
Thermal performance
Baseplate operating
temperature,
-25 °C to +100 °C
(See Notes 6, 8)
Non-operating
Remote ON/OFF
Logic compatibility
ON
OFF
-55 °C to +100 °C
6.5 °C/W
CMOS/TTL
Open circuit
<1 Vdc
Thermal impedance
Free air convection,
baseplate to air
With heatsink (See Note 8)
5.2 °C/W
Embedded Power for
Business-Critical Continuity
Rev.12.17.07
bxa30
3 of 5
Ordering Information
INPUT
OUTPUT
VOLTAGE
OUTPUT
INPUT
TYPICAL
REGULATION
MODEL
(1)
(2)
(3)
(4,6,14,15)
VOLTAGE
CURRENT (MAX.)
CURRENT
EFFICIENCY
LINE
LOAD
NUMBER
9-18 Vdc
36-75 Vdc
36-75 Vdc
36-75 Vdc
36-75 Vdc
36-75 Vdc
36-75 Vdc
36-75 Vdc
36-75 Vdc
5.0 V
3.3 V
5.0 A
6.0 A
8.0 A
5.0 A
2.5 A
2.0 A
2.5 A
1.25 A
1.0 A
100 mA
30 mA
30 mA
30 mA
30 mA
30 mA
30 mA
30 mA
30 mA
80ꢀ
75ꢀ
81ꢀ
80ꢀ
85ꢀ
87ꢀ
80ꢀ
84ꢀ
86ꢀ
0.2ꢀ
0.2ꢀ
0.2ꢀ
0.2ꢀ
1.0ꢀ
0.2ꢀ
0.2ꢀ
0.4ꢀ
0.4ꢀ
0.4ꢀ
BXA30-12S05J
BXA30-48S3V3J
BXA30-48S3V3/8J (11)
BXA30-48S05J
0.2ꢀ
0.2ꢀ
0.4ꢀ
0.2ꢀ
0.2ꢀ
0.4ꢀ
0.4ꢀ
0.4ꢀ
3.3 V
5.0 V
12.0 V
15.0 V
5.0 V
BXA30-48S12J
BXA30-48S15J
BXA30-48D05J
BXA30-48D12J
BXA30-48D15J
12.0 V
15.0 V
Notes
1
2
3
4
Nominal, at no load.
Low line to high line.
Full load to no-load. For duals, the value stated is for balanced loads.
An optional internal filter is available, which will meet VDE0871 level A,
VDE0878 level A and EN55022 level A. Add the suffix ‘-F’ to the model number,
e.g. BXA30-48S12-FJ. See BXA15 and BXA30 Design Note 100.
For conducted noise operation of the BXA30 to VDE0871, VDE0878 and
EN55022 level B, see BXA15 and BXA30 Design Note 100.
For extended operating temperature, include the heatsink option, ‘-1’ in the
model number. Max. heatsink height is 12.5 mm, e.g. BXA30-48S15-1J
Reverse voltage protection can be implemented by putting a slow blow fuse on
the negative input rail. Rate the fuse for 48 Vdc at 1.5 A and 12 Vdc at 6 A.
The maximum operating ambient temperature, without derating depends on
internal power dissipation and hence efficiency and cooling method. BXA15
and BXA30 Design Note 100 provides detailed thermal calculations and design-
in details.
5
6
7
8
9
Test results to-date are 1,590,000 hours @ 46 ˚C. The MTBF figure shown
includes a calculated acceleration factor of 4.1 based on an activation energy of
-0.55 eV.
10 Visit the Artesyn website to download a copy of Design Note 100.
11 This model has the same electrical pin-out and pin pitch spacings as the
drawing on the following page. Dimensions are 76.2 x 76.2 x 14.2 mm, 0.3
mm.
12 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
13 If remote sense is not used, connect +sense to +vout and -sense to -vout.
14 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special
request, please contact your local sales representative for details.
15 NOTICE: Some models do not support all options. Please contact your local
Artesyn representative or go to www.powerconversion.com to find a suitable
alternative
Embedded Power for
Business-Critical Continuity
Rev.12.17.07
bxa30
Specifications Contd.
4 of 5
0.76
3.02
(19.200.30)
(76.30 0.30)
2.50
0.302
(63.5)
0.20
(7.670.30)
(5.08)
0.20 (5.08)
3
8
4
5
0.80 (20.32)
0.50 (12.70)
0.95
(24.13)
0.6 (15.24)
0.4 (10.16)
1
2
2.41
6
7
(61.100.30
)
BOTTOM
0.70 (17.78)
0.30 (7.62)
1.30
VIEW
(33.02)
1.15
(29.21)
Ø 1.000
8 Places
0.52
2.00
(13.300.30)
Case/Metal Inserts M3.0
(Typ. 4 Places)
(50.80)
SIDE VIEW
ALL DIMENSIONS IN INCHES (mm)
Tolerance .XX 0.02
.XXX 0.005
PIN CONNECTIONS
EXTERNAL OUTPUT TRIMMING
5
4
5
4
PIN NUMBER
SINGLE OUTPUT
+ Vin
DUAL OUTPUT
+ Vin
Single output models can be
externally trimmed by 10ꢀ
using either method shown.
1
2
3
4
5
6
7
8
TRIM
UP
– Vin
– Vin
10K
TRIMPOT
+ Sense (13)
Trim
+ Vout
TRIM
DOWN
Common
– Vout
3
3
– Sense
+ Vout
No Pin
– Vout
No Pin
Remote ON/OFF
Remote ON/OFF
Embedded Power for
Business-Critical Continuity
Rev.12.17.07
bxa30
5 of 5
Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
16th - 17th Floors, Lu Plaza
2 Wing Yip Street, Kwun Tong
Kowloon, Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.powerconversion.com
technicalsupport@powerconversion.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Power
Inbound Power
Integrated Cabinet Solutions
Outside Plant
Precision Cooling
Site Monitoring and Services
EmersonNetworkPower. com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2007 Emerson Electric Co.
相关型号:
©2020 ICPDF网 联系我们和版权申明