LPS252-C [EMERSON-NETWORKPOWER]
Active power factor correction; 有源功率因数校正型号: | LPS252-C |
厂家: | EMERSON NETWORK POWER |
描述: | Active power factor correction |
文件: | 总3页 (文件大小:429K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Embedded Power for
Business-Critical Continuity
Rev. 2.16.09_158
LPS250 Series
1 of 3
LPS250 Series
250 Watts
Total Power: 250 Watts
Input Voltage: 85-264ꢀVac
ꢀ
ꢀꢀ120ꢀ-ꢀ300ꢀVdc
# of Outputs: ꢀSingle
Electrical Specifications
Input
Special Features
•ꢀ Activeꢀpowerꢀfactorꢀcorrection
•ꢀ IECꢀEN6100-3-2ꢀcompliance
•ꢀ Remoteꢀsenseꢀ&ꢀremoteꢀinhibit
•ꢀ Powerꢀfail
•ꢀ Singleꢀwireꢀcurrentꢀsharing
•ꢀ Built-inꢀEMIꢀfilter
•ꢀ 2:1ꢀWideꢀrangeꢀoutputꢀvoltageꢀꢀ
adjust
•ꢀ 2ꢀSupervisoryꢀoutputsꢀ5ꢀVꢀandꢀ12ꢀV
•ꢀ Overvoltageꢀprotection
•ꢀ Overloadꢀprotection
Inputꢀrange:
Frequency:
Inrushꢀcurrent:
Efficiency:
85-264ꢀVac;ꢀ120ꢀ-ꢀ300ꢀVdcꢀ
47-440ꢀHz
20ꢀAꢀmax,ꢀcoldꢀstartꢀ@ꢀ25ꢀ°C
75% typical at full load
EMIꢀfilter:
FCC Class B conducted and radiated
ꢀ
CISPRꢀ22ꢀClassꢀBꢀconductedꢀandꢀradiated
EN55022ꢀClassꢀBꢀconductedꢀandꢀradiated
VDEꢀ0878ꢀPT3ꢀClassꢀBꢀconductedꢀandꢀradiated
Safetyꢀgroundꢀ
leakageꢀcurrent:
<ꢀ0.5ꢀmAꢀ@ꢀ50/60ꢀHz,ꢀ264ꢀVACꢀinput
•ꢀ Thermalꢀoverloadꢀprotection
•ꢀ DCꢀpowerꢀgood
Output
•ꢀ 120ꢀkHzꢀswitchingꢀfrequency
•ꢀ Coverꢀ-C
Maximumꢀpower:
Withꢀcover:ꢀ250ꢀWꢀwithꢀ30ꢀCFMꢀforcedꢀair.
(-C) (-CF) (CEF)
•ꢀ Optionalꢀtopꢀwithꢀfanꢀcoverꢀ-CF
•ꢀ Optionalꢀendꢀfanꢀcoverꢀ-CEF
Supervisoryꢀoutput:
Adjustmentꢀrange:
Hold-upꢀtime:
5ꢀVꢀ@ꢀ100ꢀmAꢀregulated;ꢀ12ꢀVꢀ@ꢀ500ꢀmA
2:1ꢀwideꢀratio
20ꢀmsꢀ@ꢀ250ꢀWꢀload,ꢀ115ꢀVACꢀnominalꢀline
Safety
Overloadꢀprotection: Shortꢀcircuitꢀprotectionꢀonꢀallꢀoutputs.ꢀCaseꢀoverloadꢀprotectedꢀ@ꢀ
10-145%ꢀaboveꢀpeakꢀrating
• VDE
0805/EN60950ꢀ(IEC950)
11774-3336-1262ꢀ
UL1950 EI32002
Overvoltageꢀprotec-
tion:
5ꢀVꢀoutput:ꢀ5.7ꢀtoꢀ6.7ꢀVDC.ꢀ
Otherꢀmodelsꢀ10%ꢀtoꢀ25%ꢀaboveꢀnominalꢀoutput
• UL
• CSAꢀ ꢀꢀꢀCSAꢀ22.2-234ꢀLevelꢀ5ꢀ
ꢀꢀꢀLR53982C
• NEMKOꢀENꢀ60950/EMKO-TUE
ꢀ
ꢀ
ꢀ
ꢀ
ꢀꢀP95102999ꢀꢀꢀ(74-sec)ꢀ203
Certificate and report
ꢀꢀꢀ2186
• CB
ꢀ
ꢀ
• CE
Markꢀ(LVD)
Embedded Power for
Business-Critical Continuity
Rev. 2.16.09_158
LPS250 Series
2 of 3
LogicꢀControl
Powerꢀfailure:
TTLꢀLogicꢀsignalꢀgoesꢀhighꢀ50-150ꢀmsecꢀafterꢀ5ꢀVꢀoutput.ꢀItꢀgoesꢀlowꢀatꢀleastꢀ4ꢀmsꢀbeforeꢀlossꢀofꢀ
regulation
Remoteꢀon/off:
DCꢀ-ꢀOK:
Requiresꢀanꢀexternalꢀcontactꢀ(N.OꢀorꢀN.C)ꢀtoꢀinhibitꢀoutputs
TTLꢀlogicꢀgoesꢀhighꢀ50-150ꢀmsecꢀafterꢀtheꢀoutput.ꢀItꢀgoesꢀlowꢀwhenꢀthereꢀisꢀlossꢀofꢀ
regulation.
Remoteꢀsense:
Compensatesꢀforꢀ0.5ꢀVꢀleadꢀdropꢀminimum,ꢀꢀwillꢀoperateꢀwithoutꢀremoteꢀsenseꢀconnected.ꢀReverseꢀ
connection protected
EnvironmentalꢀSpecifications
Operatingꢀtemperature: 0°ꢀtoꢀ50ꢀ°Cꢀambient;
derateꢀeachꢀoutputꢀatꢀ2.5%ꢀperꢀdegreeꢀfromꢀ50°ꢀtoꢀ70ꢀ°C
-40ꢀ°Cꢀtoꢀ+85ꢀ°Cꢀ
Storageꢀtemperature:
Temperatureꢀcoefficient: ±ꢀ0.4%ꢀperꢀ°C
Electromagneticꢀ
susceptibility:ꢀ
DesignedꢀtoꢀmeetꢀIECꢀ801,ꢀ-2,ꢀ-3,ꢀ-4,ꢀ-5,ꢀ-6,ꢀLevelꢀ3
Humidity:
Operating;ꢀnon-condensingꢀ5%ꢀtoꢀ95%
Vibration:
Threeꢀorthogonalꢀaxes,ꢀsweepꢀatꢀ1ꢀoct/min,ꢀ5ꢀmin.ꢀdwellꢀatꢀfourꢀmajorꢀresonancesꢀ0.7ꢀGꢀ
peakꢀ5ꢀHzꢀtoꢀ500ꢀHz,ꢀoperational
MTBFꢀdemonstrated:
ꢀ>ꢀ550,000ꢀhoursꢀatꢀfullꢀloadꢀandꢀ25ꢀ°Cꢀambientꢀconditions
OrderingꢀInformation
Maximum Load with
30CFM Forced Air
1
2
3
Model Number Output Voltage Minimum Load
Peak Load Regulation Ripple P/P (PARD)
LPS252-C
LPS253-C
LPS254-C
LPS255-C
5ꢀVꢀ(3ꢀ-ꢀ6ꢀV)
12ꢀVꢀ(6ꢀ-ꢀ12)ꢀV
15ꢀ(12ꢀ-ꢀ24ꢀV)
24ꢀVꢀ(24ꢀ-48ꢀV)
1.50ꢀA
0.63ꢀA
0.50ꢀA
0.32ꢀA
50ꢀA
21ꢀA
60ꢀA
25ꢀA
±2%
±2%
±2%
±2%
50ꢀmV
120ꢀmV
150ꢀmV
240ꢀmV
16.7ꢀA
10.4ꢀA
20ꢀA
12.5ꢀA
1.ꢀPeakꢀcurrentꢀlastingꢀ<ꢀ30ꢀsecondsꢀwithꢀaꢀmaximumꢀ10%ꢀdutyꢀcycle.
2.ꢀAtꢀ25ꢀ°Cꢀincludingꢀinitialꢀtolerance,ꢀlineꢀvoltage,ꢀloadꢀcurrentsꢀandꢀoutputꢀvoltagesꢀadjustedꢀtoꢀfactoryꢀsettings.
3.ꢀPeak-to-peakꢀwithꢀ20ꢀMHzꢀbandwidthꢀandꢀ10ꢀµFꢀinꢀparallelꢀwithꢀaꢀ0.1ꢀµFꢀcapacitorꢀatꢀratedꢀlineꢀvoltageꢀandꢀloadꢀranges.
4.ꢀIfꢀoptionalꢀCFꢀorꢀCEFꢀfansꢀareꢀnotꢀused,ꢀ30CFMꢀforcedꢀairꢀcoolingꢀneedsꢀtoꢀbeꢀprovidedꢀandꢀisꢀrequiredꢀthroughꢀtheꢀlengthꢀofꢀtheꢀpowerꢀsupply.ꢀ
Notꢀconvectionꢀrated.
5.ꢀꢀOutputꢀvoltageꢀadjustmentꢀrequiresꢀaꢀminimumꢀload.
6.ꢀRemoteꢀinhibitꢀresetsꢀOVPꢀlatch
Note:ꢀꢀ-CFꢀsuffixꢀaddedꢀtoꢀtheꢀmodelꢀnumberꢀindicatesꢀcoverꢀwithꢀtopꢀfan.ꢀꢀ-CEFꢀsuffixꢀaddedꢀtoꢀtheꢀmodelꢀnumberꢀindicatesꢀcoverꢀwithꢀdualꢀendꢀ
mountedꢀfanꢀcoverꢀandꢀACꢀinlet.
Embedded Power for
Business-Critical Continuity
Rev. 2.16.09_158
LPS250 Series
3 of 3
MechanicalꢀDrawing
Americas
6-32 (2 places)
Main Output
M3 (4 places)
#6-32 (4 places)
.24 (6.1)
#6-32
M3
5810ꢀVanꢀAllenꢀWay
Carlsbad,ꢀCAꢀ92008
USA
SK3
Terminal
10.0
Block TB1
12345678
Telephone:ꢀ+1ꢀ760ꢀ930ꢀ4600
Facsimile:ꢀꢀ +1ꢀ760ꢀ930ꢀ0698
SK5
+ve -ve
10.0
SK4
FAN
3.68
Europe (UK)
(93.6)
WaterfrontꢀBusinessꢀPark
MerryꢀHill,ꢀDudley
SK7
FAN
5.46
(138.6)
WestꢀMidlands,ꢀDY5ꢀ1LX
UnitedꢀKingdom
Telephone:ꢀ+44ꢀ(0)ꢀ1384ꢀ842ꢀ211
Facsimile:ꢀ +44ꢀ(0)ꢀ1384ꢀ843ꢀ355
6.64
(168.6)
Optional
(-CF)
3.15
(80)
8.52
(216.4)
Cover
Asia (HK)
14/F,ꢀLuꢀPlaza
with Fan
9.0
(228.6)
2ꢀWingꢀYipꢀStreet
KwunꢀTong,ꢀKowloon
HongꢀKong
Telephone:ꢀ+852ꢀ2176ꢀ3333
Facsimile:ꢀ +852ꢀ2176ꢀ3888
M3
10.32
(262.0)
2.17
(55)
10.0
3
2
1
Optional
(-CEF)
1.18 (30.0)
6-32 (3 places)
Forꢀglobalꢀcontact,ꢀvisit:
Cover
SK1
#6-32
www.PowerConversion.com
with fans
5.0 (127.0)
techsupport.embeddedpower
@emerson.com
2.0
(50.8)
3.0
(76.2)
Whileꢀeveryꢀprecautionꢀhasꢀbeenꢀtakenꢀtoꢀensureꢀ
accuracyꢀandꢀcompletenessꢀinꢀthisꢀliterature,ꢀEmersonꢀ
NetworkꢀPowerꢀassumesꢀnoꢀresponsibility,ꢀandꢀdisclaimsꢀ
allꢀliabilityꢀforꢀdamagesꢀresultingꢀfromꢀuseꢀofꢀthisꢀ
information or for any errors or omissions.
.55
(14)
1.30
(33.0)
AC Inlet
Emerson Network Power.
Theꢀglobalꢀleaderꢀinꢀenabling
business-critical continuity.
.79
(20)
3.42 (87.0)
ACꢀPower
MatingꢀConnectors
PinꢀAssignments
Connector
Connectivity
Molexꢀ22-01-1084
PINS:08-70-0057
SK3
SK4
SK5
DCꢀPower
Neutral
SK1 PINꢀ1
Molexꢀ22-01-3027
PINS:ꢀ08-50-0114
Line
PINꢀ2
EmbeddedꢀComputing
Embedded Power
Monitoring
Ground
PINꢀ3
Molexꢀ22-01-3027
PINS:ꢀ08-50-0114
+ꢀRemoteꢀsense
-ꢀRemoteꢀsense
Remoteꢀinhibitꢀ(N.O.)
Remoteꢀinhibitꢀ(N.C.)
Common
SK3 PINꢀ1
PINꢀ2
Molexꢀ22-01-3027
PINS:ꢀ08-50-0114
SK7
PINꢀ3
PINꢀ4
PINꢀ5
OutsideꢀPlant
EmersonꢀNetworkꢀPowerꢀConnectorꢀKitꢀ#70-841-005,ꢀincludesꢀallꢀofꢀtheꢀ
above
PowerꢀSwitchingꢀ&ꢀControls
PrecisionꢀCooling
Currentꢀsharing
Power fail
PINꢀ6
PINꢀ7
1.ꢀ Specificationsꢀsubjectꢀtoꢀchangeꢀwithoutꢀnotice.
ꢀ2.ꢀ Allꢀdimensionsꢀinꢀinchesꢀ(mm),ꢀtoleranceꢀisꢀ±ꢀ0.02ꢁꢀ(±ꢀ0.5mm)
3.ꢀ Specificationsꢀareꢀatꢀfactoryꢀsettings.
4.ꢀ Toꢀenableꢀnormallyꢀclosedꢀremoteꢀinhibit,ꢀcutꢀjumperꢀJ1.
5.ꢀ Mountingꢀmaximumꢀinsertionꢀdepthꢀisꢀ0.12ꢁ.
6.ꢀ Warranty:ꢀꢀ2ꢀyear
Racksꢀ&ꢀIntegratedꢀCabinets
DCꢀPowerꢀGood
PINꢀ8
+ꢀFan’sꢀpowerꢀsourceꢀ(12ꢀVꢀ@ꢀ500ꢀmA)
-ꢀꢀFan’sꢀpowerꢀsourceꢀ(12ꢀVꢀ@ꢀ500ꢀmA)
+ꢀSupervisoryꢀoutputꢀsupplyꢀ(5ꢀVꢀ@ꢀ100ꢀmA)
-ꢀꢀSupervisoryꢀoutputꢀsupplyꢀ(5ꢀVꢀ@ꢀ100ꢀmA)
+ꢀFan’sꢀpowerꢀsourceꢀ(12ꢀVꢀ@ꢀ500ꢀmA)
-ꢀꢀFan’sꢀpowerꢀsourceꢀ(12ꢀVꢀ@ꢀ500ꢀmA)
SK4 PINꢀ1
Pin 2
SK5 PINꢀ1
PINꢀ2
SK7 PINꢀ1
PINꢀ2
Services
SurgeꢀProtection
7.ꢀ Weight:ꢀꢀ2.6ꢀlbꢀ/ꢀ1.19ꢀkg
EmersonNetworkPower.com
EmersonꢀNetworkꢀPowerꢀandꢀtheꢀEmersonꢀ
NetworkꢀPowerꢀlogoꢀareꢀtrademarksꢀandꢀ
serviceꢀmarksꢀofꢀEmersonꢀElectricꢀCo.ꢀꢀ
©2008 Emerson Electric Co.
相关型号:
©2020 ICPDF网 联系我们和版权申明