LQS40A241V5AKJ [EMERSON-NETWORKPOWER]
Quarter-Brick Series; 四分之一砖系列型号: | LQS40A241V5AKJ |
厂家: | EMERSON NETWORK POWER |
描述: | Quarter-Brick Series |
文件: | 总4页 (文件大小:145K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Quarter-Brick Series
S i n g l e o u t p u t
DC-DC CONVERTERS
High Current, High Efficiency, Low Profile
1
NEW Product
• Ultra high efficiency topology
•
•
Unprecedented useable output power levels
High power density (200 W/in3) open-frame technology
• Wide ambient temperature range, -40 ºC to +85 ºC
• 80% to 110% output trim
• Monotonic start-up in normal and prebiased loads
• Basic insulation system
• Overvoltage and overtemperature protection
• Secondary side control, no optocouplers,
fast transient response
• 100 V, 100 ms input transient rated
• Available RoHS compliant
This is a new high efficiency, open-frame, low profile, single board, isolated dc-dc converter
series in an industry standard quarter-brick package that provides up to 200 W of output power.
The series delivers very high output current at low voltages, and excellent useable power for
today’s high performance applications. The series features two input voltage ranges of 18 Vdc
to 36 Vdc and 36 Vdc to 75 Vdc and is available with output voltages of 1.2 V, 1.5 V, 1.8 V,
2.5 V, 3.3 V and 5 V. The output voltage is adjustable from 80% to 110% of the nominal value.
The series also has a remote ON/OFF capability. Overcurrent, overvoltage and overtemperature
protection features are included as standard. Full international safety approval including
EN60950-1 VDE and UL/cUL60950, reduces compliance costs and time to market.
Patent No. 6,765,810
Other Patents Pending
2 YEAR WARRANTY
All specifications are typical at nominal input, full load at 25 °C ambient unless otherwise stated
SPECIFICATIONS
OUTPUT SPECIFICATIONS
Voltage adjustability
Minimum load
EMC CHARACTERISTICS
80% to 110%
0%
Immunity:
ESD air enclosure
EN61000-4-2 8 kV/6 kV(O/P within spec.)
Radiated field enclosure EN61000-4-3 10 V/m (O/P within spec.)
Conducted
Input transients
EN61000-4-6 10 V
100 V, 100 ms
(O/P within spec.)
Overshoot
At turn-on and turn-off
None
Undershoot
None
GENERAL SPECIFICATIONS
Transient response
(See Note 1)
70 mV,
typ. deviation
20 µs recovery
Basic insulation
Input/output
2250 Vdc
480 kHz
Switching frequency
Fixed
INPUT SPECIFICATIONS
Approvals and
standards
(See Note 3)
EN60950-1 VDE
UL/cUL 60950
Input voltage range
24 V nominal
48 V nominal
18-36 Vdc
36-75 Vdc
Material flammability
Weight
UL94V-0
Input current
No load
Remote OFF
85 mA to 150 mA
5 mA
37 g (1.30 oz)
MTBF
Telcordia Tech SR-332 3,866,933 hours
Active high remote ON/OFF
Logic compatibility
Open collector ref to -input
Open circuit or >2.4 Vdc
<0.4 Vdc
ENVIRONMENTAL SPECIFICATIONS
ON
OFF
Thermal performance
Operating ambient,
-40 °C to +85 °C
-55 °C to +125 °C
temperature
Undervoltage lockout
Power up
Power down
35.5 V (typ.)
33.5 V (typ.)
Non-operating
Start-up time
(See Note 2)
Power up
Remote ON/OFF
10 ms (typ.)
10 ms (typ.)
PROTECTION
Short-circuit
Overvoltage
Thermal
Continuous
Non-latching
125 ºC hot spot temperature
with automatic recovery
International Safety Standard Approvals
UL/cUL CAN/CSA 22.2 No. 60950-00 : UL 60950
File No. E135734/60950
VDE Certificate No. 10401-3336-0197
File Name: quarter_brick_single.pdf Rev (07): 17 Nov 2005
Quarter-Brick Series
S i n g l e o u t p u t
DC-DC CONVERTERS
High Current, High Efficiency, Low Profile
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
NEW Product
INPUT
CURRENT
(MAX.) (4)
INPUT
RIPPLE
CURRENT (5)
OUTPUT
CURRENT
(MAX.)
REGULATION
OUTPUT
VOLTAGE
EFFICIENCY
(TYP.)
MODEL
NUMBER (6,9,10)
RIPPLE &
NOISE
SET POINT
LINE
LOAD
ACCURACY
(Max.)
(pk - pk)
48 Vin VALUE MODELS
1.2 V
1.5 V
1.8 V
1.92 A
2.36 A
2.82 A
150 mA
150 mA
150 mA
50 A
50 A
50 A
88.5%
89.5%
90.4%
1.5%
0.1%
0.1%
0.1%
0.2%
0.2%
0.2%
60 mV
60 mV
60 mV
LQS50A48-1V2J
LQS50A48-1V5J
LQS50A48-1V8J
1.5%
1.5%
48 Vin PERFORMANCE MODELS
1.2 V
1.5 V
1.8 V
2.5 V
3.3 V
4.05 A
3.8 A
4.6 A
4.1 A
5.2 A
250 mA
200 mA
200 mA
200 mA
200 mA
100 A
80 A
80 A
50 A
50 A
86.0%
88.8%
90.0%
90.0%
91.0%
1.5%
1.5%
1.5%
1.5%
1.5%
0.1%
0.1%
0.1%
0.1%
0.1%
0.2%
0.2%
0.2%
0.2%
0.2%
60 mV
60 mV
60 mV
60 mV
60 mV
LQS100A48-1V2J
LQS80A48-1V5J
LQS80A48-1V8J
LQS50A48-2V5J
LQS50A48-3V3J
48 Vin ULTRA MODELS
1.5 V
1.8 V
2.5 V
3.3 V
5 V
4.8 A
5.7 A
6.2 A
6.2 A
6.2 A
200 mA
200 mA
200 mA
200 mA
200 mA
100 A
100 A
80 A
88.5%
89.5%
1.5%
0.1%
0.1%
0.1%
0.1%
0.1%
0.2%
0.2%
0.2%
0.2%
0.2%
60 mV
60 mV
60 mV
60 mV
60 mV
LQS100A48-1V5J
LQS100A48-1V8J
LQS80A48-2V5J
LQS60A48-3V3J
LQS40A48-5V0J (7)
1.5%
1.5%
1.5%
1.5%
91.0%
60 A
91.0%
40 A
92.0%
24 Vin MODELS
91.0%
1.8 V
3.3 V
3.4 A
6.5 A
200 mA
300 mA
30 A
30 A
1.5%
1.5%
0.1%
0.1%
0.2%
0.2%
60 mV
60 mV
LQS30A24-1V8J
LQS30A24-3V3J
89.5%
Part Number System with Options
L Q S 6 0 A 4 8 - 3 V 3 R A N J
RoHS Compliance (9)
J = Pb-free (RoHS 6/6 compliant)
L = Low Profile
Q = 1/4 Brick
Pin Length Options
Blank = 0.188” (4.78 mm)
N = 0.145” (3.68 mm)
K = 0.110” (2.79 mm)
Type of output
S = Single
Body Height, Package Type and Pin Length
A = 0.300” (7.62 mm), Through Hole,
0.188” (4.78 mm) Pins
Rated Output Current
40 A = 40 Amps, 60 A = 60 Amps etc.
E = 0.340” (8.64 mm), Through Hole,
0.188” (4.78 mm) Pins
S = 0.28” (7.11 mm), Surface Mount(6)
Nominal Rated Input Voltage
24 = 24 Volts (18 Vdc to 36 Vdc range)
48 = 48 Volts (36 Vdc to 75 Vdc range)
Remote ON/OFF Logic
Blank = Positive
Output Voltage
R = Negative
1V5 = 1.5 Volts, 1V8 = 1.8 Volts etc.
Notes
1
di/dt = 1 A/µs, Vin = 48 Vdc, Tc = 25 °C, load change = 50% to 75% lo
max. and 75% to 50% lo max. Deviation varies by model. For further
details see longform datasheet.
7
8
Except LQS40A48-5V0J which has the double output pins.
Active low Remote ON/OFF is available. Standard product is Active
High. When ordering active low parts, designate with the Suffix ‘R’ e.g.
LQS100A48-1V8RAJ.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on
special request, please contact your local sales representative for details.
2
3
Start-up into resistive load.
9
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
Recommended input fusing is up to 10 A HRC 200 V rated fuse.
Peak to peak measured without external π filter. Significant reduction
possible with external filter. See Application Note 141 for further details.
‘S’ option applies to the 24 V models only.
10 NOTICE: Some models do not support all options. Please contact your
local Artesyn representative or use the on-line model number search tool
at http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
4
5
6
File Name: quarter_brick_single.pdf Rev (07): 17 Nov 2005
Quarter-Brick Series
S i n g l e o u t p u t
DC-DC CONVERTERS
High Current, High Efficiency, Low Profile
3
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
NEW Product
2.30 (58.4)
2.000 (50.80)
2.30
(58.4)
0.055 (1.40) x 0.105 (2.67)
(8 pls)
2.186
0.15
(3.8)
(55.52)
0.057 0.020
(1.45 0.51)
ø0.040 0.002 (ø1.02 0.05)
(6 pls)
0.150
(3.81)
TOP VIEW
1
2
8
7
6
5
4
8
7
6
5
1
2
3
0.300
(7.62)
0.300
(7.62)
TOP VIEW
1.45
1.45
(36.8)
(36.8)
0.300
(7.62)
3
4
0.300
(7.62)
0.150
(3.81)
0.150
(3.81)
0.150
(3.81)
0.725 0.020
(18.42 0.51)
0.725 0.020
(18.42 0.51)
ø 0.062 0.002
(ø1.57 0.05)
(2 pls)
HEIGHT
0.28 (7.1)
HEIGHT
(See Option Table)
CLEARANCE
(See Option Table)
CLEARANCE
0.015 (0.38)
0.188 (4.78)
ø0.080 0.008
(ø2.03 0.02)
(2 pls)
ø0.058 0.008
(ø1.47 0.02)
(6 PLS)
Ref IPC-2222
Level B
2.30 (58.4)
2.000 (50.80)
2.30
(58.4)
Ref IPC-2222
Level B
2.186
(55.52)
0.15
(3.8)
0.067(1.70) x 0.118(3.00)
(8 pls)
0.057 0.020
(1.45 0.51)
0.150
(3.81)
TOP VIEW
1
2
8
7
6
5
4
1
2
3
8
0.300
(7.62)
0.300
7
6
5
4
1.45
1.45
(36.8)
(7.62)
0.300
(7.62)
(36.8)
3
0.150
(3.81)
0.300
(7.62)
0.150
(3.81)
0.150
(3.81)
0.15
(3.8)
0.725 0.020
(18.42 0.51)
Lead coplanarity within 0.006 (0.15) max.
0.725 0.020
(18.42 0.51)
ø 0.074 0.003
(ø1.88 0.08)
(2 pls)
ø 0.054 0.003
(ø1.37 0.08)
(6 pls)
2.000
(50.80)
Dimensions in Inches (mm)
Tolerances (unless otherwise specified)
x.xx 0.02 (x.x 0.5)
Dimensions in Inches (mm)
Tolerances (unless otherwise specified)
x.xx 0.02 (x.x 0.5)
RECOMMENDED PCB LAYOUT
x.xxx 0.010 (x.xx 0.25)
RECOMMENDED HOLE PATTERN
x.xxx 0.010 (x.xx 0.25)
24 V Surface-mount Mechanical Drawing and Pinout Table
24 V/48 V Mechanical Drawing for Output Current of 50 A or Less
(See Note 7)
PIN CONNECTIONS
DIMENSION OPTIONS
PIN NUMBER
FUNCTION
+Vin
PIN NUMBER
FUNCTION
-Sense
Trim
OPTION
CLEARANCE
HEIGHT
1
2
3
4
5
6
7
8
+0.022 (0.56)
-0.030 (0.76)
0.016 (0.41)
ON/OFF
-Vin
A
E
0.030 (0.76)
0.070 (1.78)
0.300 (7.62)
0.340 (8.64)
+Sense
+Vout
-Vout
Pin Connection Table
Dimension Options Table
File Name: quarter_brick_single.pdf Rev (07): 17 Nov 2005
Quarter-Brick Series
S i n g l e o u t p u t
DC-DC CONVERTERS
High Current, High Efficiency, Low Profile
4
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
NEW Product
2.30 (58.4)
2.000 (50.80)
0.118
(3.00)
0.15
(3.8)
ø 0.040 0.002
(ø1.02 0.05)
(6 pls)
0.300
(7.62)
TOP VIEW
1.45
(36.8)
0.300
(7.62)
0.150
(3.81)
0.150
(3.81)
0.725 0.020
(18.42 0.51)
ø0.062 0.002
(ø1.57 0.05)
(4 pls)
CLEARANCE
(See Option Table)
HEIGHT
(See Option Table)
0.188 (4.78)
2.30 (58.4)
2.000 (50.80)
0.15
(3.8)
0.118
(3.00)
0.300
(7.62)
1.45
0.300
(7.62)
(36.8)
0.150
(3.81)
0.150
(3.81)
ø 0.074 0.003
(ø1.88 0.08) (4 pls)
Ref IPC-2222 Level B
0.725 0.020
(18.42 0.51)
ø 0.058 0.008
(ø1.47 0.02) (6 pls)
Ref IPC-2222 Level B
Dimensions in Inches (mm)
Tolerances (unless otherwise specified)
x.xx 0.02 (x.x 0.5)
x.xxx 0.010 (x.xx 0.25)
RECOMMENDED HOLE PATTERN
48 V Mechanical Drawing for Output Current Greater than 50 A
“The Double P” Pinout (7)
PIN CONNECTIONS
FUNCTION PIN NUMBER
+Vin
DIMENSION OPTIONS
PIN NUMBER
FUNCTION
-Sense
Trim
OPTION
CLEARANCE
HEIGHT
1
2
3
4
5
6
+0.022 (0.56)
-0.030 (0.76)
0.016 (0.41)
ON/OFF
-Vin
7
8
A
E
0.030 (0.76)
0.070 (1.78)
0.300 (7.62)
0.340 (8.64)
+Sense
+Vout
-Vout
-Vout
9
10
+Vout
Pin Connection Table
Dimension Options Table
Datasheet © Artesyn Technologies
® 2005
The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. The information and specifications contained or described herein are subject to change in any manner at any time without notice. No rights under any patent
accompany the sale of any such product(s) or information contained herein.
Please consult our website for the following items: ꢀ Application Note ꢀ Longform Datasheets
www.artesyn.com
File Name: quarter_brick_single.pdf Rev (07): 17 Nov 2005