NFS110_09 [EMERSON-NETWORKPOWER]
Single & Quad output; 单,四路输出型号: | NFS110_09 |
厂家: | EMERSON NETWORK POWER |
描述: | Single & Quad output |
文件: | 总5页 (文件大小:453K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Embedded Power for
Business-Critical Continuity
Rev. 11.2.09_69
NFS110 Series
1 of 5
NFS110 Series
Single & Quad output
Total Power:
80 - 110 W
Input Voltage: 85 - 264 Vac
120 - 370 Vdc
# of Outputs: Single, quad
Electrical Specifications
Special Features
• 7.0 x 4.25 x 1.8 inch package
• Overvoltage and short circuit
protection
• 110 W with 20 CFM
• Adjustable outputs
• EN55022, EN55011 conducted
emissions level B
• UL, VDE and CSA safety
approvals
Output
Voltage adjustability:
+5.1 V o/p on multi’s
5.1 V single output
12 V single output
15 V single output
24 V single output
3.0%
3.0%
12 - 14 V
15 - 18 V
24 - 30 V
Line regulation:
LL to HL, FL
±0.1% max.
All outputs on all units
Overshoot/undershoot:
Temperature coefficient:
Overvoltage protection:
At turn-on
All outputs
0%
• CE mark
• Available RoHS compliant
• 2 year warranty
±0.02%/°C
Multi o/p 5.1 V only
5.1 V single output
12 V single output
15 V single output
24 V single output
6.25 V ± 0.75 V
6.25 V ± 0.75 V
15.75 V ± 1.0 V
22 V ± 1.5 V
33 V ± 2.5 V
Output power limit:
Primary power limited
Pin max. 160 W
Pout min. 110 W
Minimum output current:
Short circuit protection:
(See Note 13)
0 A
Safety
Burst mode operation
• VDE0805/EN60950/
• IEC950/IEC1010
Input
Input voltage range:
85 - 264 Vac
120 - 370 Vdc
File No. 10401-3336-0213
• Licence No. 4001467 7
• UL1950 File No. E132002
• CSA C22.2 No. 950
File No. LR41062C
Input frequency range:
Input surge current:
47 - 440 Hz
35 A
230 Vac
Safety ground leakage current:
110 Vac, 50 Hz
230 Vac, 50 Hz
0.2 mA, max.
0.4 mA, max.
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
Embedded Power for
Business-Critical Continuity
Rev. 11.2.09_69
NFS110 Series
2 of 5
EMC Characteristics
Conducted emissions:
Radiated emissions:
ESD air:
EN55022, FCC part 15
EN55022, FCC part 15
EN61000-4-2, level 3
EN61000-4-2, level 4
EN61000-4-3, level 3
EN61000-4-4, level 3
EN61000-4-5, level 3
EN61000-4-6, level 3
Level B
Level A
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 2
Perf. criteria 1
ESD contact:
Surge:
Fast transients:
Radiated immunity:
Conducted immunity:
General Specifications
Hold-up time:
110 Vac @ 80 W
110 Vac @ 110 W
230 Vac @ 80 W
230 Vac @ 100 W
35 ms
17 ms
140 ms
100 ms
Efficiency:
Multiple outputs
+5.1 V single
12 V and 15 V singles
24 V single
70% typical
70% typical
72% typical
75% typical
Isolation voltage:
Input/output
Input/chassis
3000 Vac
1500 Vac
Approvals and standards:
(see note 12)
VDE0805, EN60950, IEC950, IEC1010, UL1950, CSA C22.2 No. 950
Weight:
Singles
Multiple outputs
550 g (19.4 oz)
600 g (21.2 oz)
MTBF (@25 ºC):
MIL-HDBK-217E
125,000 hours min.
Environmental Specifications
Thermal performance:
Operating ambient
0° C to +70 °C
(See notes 9, 10)
Non-operating
-40 °C to +85 °C
80 W
0 °C to 50 °C convection cooled
+50 °C to +70 °C, convection cooled Derate 2 W/°C
0 °C to +50 °C, 20 CFM forced air
+50 °C to +70 °C, 20CFM forced air
110 W
Derate 2.75 W/°C
Peak, 0 °C to +50 °C, max. 60 seconds 110W
Relative humidity:
Altitude:
Non-condensing
Operating
5 to 95% RH
10,000 feet max.
40,000 feet max.
2.4 G rms peak
Non-operating
5 - 500 Hz
Vibration:
(See Note 11)
Embedded Power for
Business-Critical Continuity
Rev. 11.2.09_69
NFS110 Series
3 of 5
Ordering Information
Output Currents
Peak (2)
20 A
Output
Total
Regulation (5)
Ripple (4)
Model Numbers (13, 15, F)
Max (1)
8 A
Fan (3)
10 A
5 A
Voltage
NFS110-7601PJ (14)
+5.1 V
+12 V
50 mV
120 mV
120 mV
50 mV
± 2.0%
± 3.0%
± 3.0%
± 3.0%
± 2.0%
+10/–5.0%
± 3.0%
± 3.0%
± 2.0%
± 4.0%
± 3.0%
± 3.0%
± 2.0%
± 2.0%
± 2.0%
4.5 A
0.5 A
0.5 A
8 A
9 A
–12 V
1.5 A
1.5 A
20 A
1 A
–5 V
1 A
NFS110-7602PJ (6, 14)
NFS110-7604PJ (14)
+5.1 V (I
)
10 A
4.5 A
5 A
50 mV
A
+24 V (I ) (6)
3.5 A
4.5 A
0.5 A
8 A
4.5 A
9 A
240 mV
120 mV
120 mV
50 mV
B
+12 V
–12 V
+5.1 V
15 V
1.5 A
20 A
1 A
10 A
5 A
4 A
7.5 A
1.5 A
1.5 A
9 A
150 mV
150 mV
50 mV
-15 V
-5 V
0.5 A
0.5 A
7 A
1 A
1 A
NFS110-7612J (7,8)
NFS110-7615J (7,8)
NFS110-7624J (7,8)
12 V
9 A
120 mV
150 mV
240 mV
15 V
5 A
7.3 A
4.5 A
7.3 A
4.5 A
24 V
3.5 A
Notes
Transient Response
NFS110-7601PJ
1
2
Convection cooled, 80 W maximum.
Peak outputs lasting less than 60 seconds with duty cycle less than 10%. Total
peak power must not exceed 110 W.
+5.1 V (7.5 A to 10 A)
+12 V (2.5 A to 5 A)
-12 V (0.5 A to 1 A)
-5 V (0.5 A to 1 A)
150 mV peak, 1 ms recovery
100 mV peak, 0.5 ms recovery
100 mV peak, 0.5 ms recovery
100 mV peak, 0.5 ms recovery
3
4
Forced air, 20 CFM at 1 atmosphere, 110 W maximum.
Figure is peak-to-peak. Output ripple is measured across a 50 MHz bandwidth
using a 12 inch twisted pair terminated with a 47 µF capacitor.
Total regulation is defined as the static output regulation at 25 °C, including
initial tolerance, line voltage within stated limits and output voltages adjusted
to their factory settings.
5
NFS110-7602PJ
NFS110-7604PJ
+5.1 V (7.5 A to 10 A)
+24 V (1.5 A to 3 A)
+12 V (2.5 A to 5 A)
-12 V (0.5 A to 1 A)
150 mV peak, 1 ms recovery
300 mV peak, 1 ms recovery
100 mV peak, 0.5 ms recovery
100 mV peak, 0.5 ms recovery
6
To achieve stated regulation on the 24 V output on the NFS110-7602PJ, the
following load condition must be true: I / I ≤ 5, where:
A
B
I
I
= +5.1 V output current, and
= +24 V output current
A
B
The +24 V output will maintain ±5.0% regulation under the following
additional condition: I ≤ 5 A.
+5.1 V (7.5 A to 10 A)
+15 V (2.5 A to 5 A)
-15 V (0.5 A to 1 A)
-5 V (0.5 A to 1 A)
150 mV peak, 1 ms recovery
100 mV peak, 0.5 ms recovery
100 mV peak, 0.5 ms recovery
100 mV peak, 0.5 ms recovery
A
7
Single output models have floating outputs which may be referenced as
either positive or negative. Higher voltage supplies may be adjusted over a
wide output voltage range, as long as the total output power does not exceed
80 Watts (natural convection) or 110 Watts (forced air).
8
9
Power fail detect not available on single output models.
Derating curve is application specific for ambient temperatures >50 °C,
for optimum reliability no part of the heatsink should exceed 90 ºC and no
semiconductor case temperature should exceed 100 ºC.
NFS110-7605J
NFS110-7612J:
NFS110-7615J
NFS110-7624J
+5.1 V (10 A to 20 A)
+12 V (4.5 A to 9 A)
+15 V (3.65 A to 7.3 A)
+24 V (2.25 A to 4.5 A)
250 mV peak, 1 ms recovery
360 mV peak, 1 ms recovery
450 mV peak, 1 ms recovery
720 mV peak, 1 ms recovery
10 Caution: Allow a minimum of 1 second after disconnecting the power when
making thermal measurements.
11 Three orthogonal axes, random vibration, 10 minute test for each axis.
12 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
13 Recommend a minimum load of 11 W to achieve the design MTBF. See the
derating curve on page 4.
14 Power failure detec is optional by including the suffix “P” to the model
number.
15 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
16 NOTICE: Some models do not support all options. Please contact your
local Emerson Network Power representative or use the on-line model
number search tool at http://www.PowerConversion.com to find a suitable
alternative.
Embedded Power for
Business-Critical Continuity
Rev. 11.2.09_69
NFS110 Series
4 of 5
OPTIONAL POWER FAIL DETECT TIMING DIAGRAM
Power fail detect signal (Note 8)
50ms ≤ T1 ≤ 200ms
T2 will vary with line and load
T3 ≥ 3ms
Pout: 110W
PFD output is an open collector which
will sink ≤ 40mA in the low state.
AC (J1) mating connector
AC INPUT
Molex 09-50-3051 or Molex 09-91-0500 mating connector with 2478
or equivalent crimp terminals.
4.75V
4.75V
5V OUTPUT
PFD SIGNAL
HIGH
3.5V MIN
T3
DC (J2) mating connector
LOW
Molex 09-50-3131 or Molex 09-91-1300 mating connector with 2478
or equivalent crimp terminals.
0-0.4 MAX
T2
T1
0.475
0.010
(12.07)
DERATING CURVE (See Notes 9, 10)
1.80 (45.72) MAX
1.00 0.005
(25.4)
Output Power (Watts)
110W
80W
20 CFM FORCED AIR COOLING
6-32 UNC
(4PL)
0.050 0.020
(1.27)
1.55 0.005
(39.37)
3.35 0.015 (85.09)
PIN 1
Voltage Adjust
Optional
NATURAL
CONVECTION
COOLING
Power Fail
J2
55W
40W
Detect Circuit
(Key = Pin 2)
4.250
0.020
(107.95)
T1
3.750
Pin 1
0.005
(95.25)
PIN 1
L1
11W
0W
11W MINIMUM LOAD REQUIRED AT 230VAC
0.156
J1
DIA. HOLE
(4PL)
0C
10C
20C
30C
40C
50C
60C
70C
C6
F1
5A, 250 VAC
Pin Connections
0.250
0.010
(6.35)
6.50 0.005 (165.1)
7.00 0.020 (177.8)
J1
-7601PJ
-7602 P
-7604PJ
Singles
Pin 1
Pin 2
Pin 3
J2
AC Ground
AC Neutral
AC Line
AC Ground AC Ground AC Ground
0.250
0.010
(6.35)
ALL DIMENSIONS IN INCHES (mm)
AC Neutral
AC Line
AC Neutral AC Neutral
AC Line
AC Line
Mechanical Notes:
A
B
C
D
E
Metallic or non-metallic stand-offs (maximum diameter 5.4mm) can be used in all four mounting holes
without effecting safety approval.
The ground pad of the mounting hole near J1, allows system grounding through a metal stand-off to
the system chassis.
The heat sink is grounded, and allows system grounding by mechanical connection to the system
chassis.
The supply must be mechanically supported using the PCB mounting holes and may be additionally
supported by the heatsink mounting holes.
It is always advisable to attach the power supply heat sink to another thermal dissipator (such as a
chassis or finned heatsink etc). The resulting decrease in heat sink mounted component temperatures
will improve power supply lifetime.
A standard L-bracket and cover is available for mounting which contains all screws, connectors and
necessary mounting hardware. The kit is available, order part number “NFS110CJ”.
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
Pin 9
Pin 10
Pin 11
Pin 12
Pin 13
+5.1 V
+5.1 V
+5.1 V
Return
Return
Return
Return
+12 V
+12 V
PFD
+5.1 V
+5.1 V
+5.1 V
Return
Return
Return
Return
+12 V
+12 V
PFD
+5.1 V
+5.1 V
+5.1 V
Return
Return
Return
Return
+15 V
+15 V
PFD
V
out
V
out
V
out
Return
Return
Return
Return
F
V
out
V
out
N/C
-12 V
-12 V
-15 V
N/C
Removed for Key
-5 V
+24 V
-5 V
N/C
N/C = no connection
Embedded Power for
Business-Critical Continuity
Rev. 11.2.09_69
NFS110 Series
5 of 5
Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.PowerConversion.com
techsupport.embeddedpower
@emerson.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
EmersonNetworkPower.com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2009 Emerson Electric Co.
相关型号:
NFS200-7601
Triple and quad output 200 Watt AC/DC universal input switch mode power supplies
ARTESYN
NFS200-7601CF
Triple and quad output 200 Watt AC/DC universal input switch mode power supplies
ARTESYN
NFS200-7602
Triple and quad output 200 Watt AC/DC universal input switch mode power supplies
ARTESYN
NFS200-7602CF
Triple and quad output 200 Watt AC/DC universal input switch mode power supplies
ARTESYN
NFS200-7603
Triple and quad output 200 Watt AC/DC universal input switch mode power supplies
ARTESYN
NFS200-7603CF
Triple and quad output 200 Watt AC/DC universal input switch mode power supplies
ARTESYN
©2020 ICPDF网 联系我们和版权申明