B25673A4202A040

更新时间:2024-09-18 09:52:08
品牌:EPCOS
描述:Film capacitors - Power Factor Correction

B25673A4202A040 概述

Film capacitors - Power Factor Correction 薄膜电容器 - 功率因数校正

B25673A4202A040 数据手册

通过下载B25673A4202A040数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。

PDF下载
Film capacitors – Power Factor Correction  
PhaseCap Compact capacitors  
Series/Type:  
MKK440-D-20-02  
Ordering code:  
B25673A4202A040  
Date:  
Version:  
May 2009  
1
Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the  
table and then change the color to "white". This ensures that the table disappears (invisible) for the customer PDF.  
Don't change formatting when entering or pasting text in the table and don't add any cell or line in and to it!  
Identification/Classification 1  
(header 1 + top left bar):  
Film capacitors – Power Factor Correction  
Identification/Classification 2  
PhaseCap Compact capacitors  
(header 2 + bottom left header bar):  
Ordering code: (top right header bar)  
Series/Type: (top right header bar)  
B25673A4202A040  
MKK440-D-20-02  
Preliminary data (optional):  
(if necessary)  
Department:  
Date:  
FK PC PM PFC  
May 2009  
1
Version:  
EPCOS AG 2009. Reproduction, publication and dissemination of this publication, enclosures hereto and the information  
contained therein without EPCOS' prior express consent is prohibited  
Film capacitors – Power Factor Correction  
PhaseCap Compact capacitors  
B25673A4202A040  
MKK440-D-20-02  
Construction  
Dielectric: Polypropylene film  
Non PCB, Semi-dry biodegradable resin  
Concentric winding  
Wave cut  
Extruded round aluminum can with stud  
Provided with ceramic discharge module  
Overpressure disconnector  
Features  
Three phase, delta connected  
Self-healing technology  
Naturally air cooled (or forced air cooling)  
Indoor mounting  
Typical applications  
For Power Factor Correction  
Terminals  
SIGUT terminals  
Mounting  
Threaded stud at bottom of can  
(max. torque = 10 Nm for M12)  
FK PC PM PFC  
May 2009  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 2 of 8  
Film capacitors – Power Factor Correction  
PhaseCap Compact capacitors  
B25673A4202A040  
MKK440-D-20-02  
Technical data and specifications  
Characteristics  
Label design  
Rated capacitance CR  
Tolerance  
3 × 109.7 µF  
–5 / +10%  
D (Delta)  
440 V AC  
50 Hz  
Connection  
Rated voltage VR  
Rated frequency fR  
Output  
60 Hz  
20.0 kvar  
26 A  
24.0 kvar  
32 A  
Rated current IR  
tan δ (dielectric)  
0.2 W / kvar  
Maximum ratings  
Vmax (up to 8 h daily) 480 V AC  
Vmax (up to 1 min)  
Imax  
570 V AC  
1.4 × IR (A) (including combined effects of  
harmonics, overvoltages and capacitance  
tolerance)  
IS  
300 × IR (A)  
Test data  
VTT  
950 V AC / 50 Hz during 10 s  
3000 V AC / 50 Hz during 10 s  
0.6 W / kvar  
VTC  
*tan δ (50 Hz)  
* Without discharge resistor  
Climatic category  
–40/D  
40 ºC  
–40/C  
40 ºC  
Tmin  
()  
Maximum power loss at ambient  
Tmax  
(+)  
55 ºC  
50 ºC  
Casing temperature  
Mean life expectancy  
Humidity  
65 ºC max.  
Up to 130 000 h  
av. rel. < 95%  
4000 m  
60 ºC max.  
Up to 180 000 h  
B25673A4202A040  
14  
12  
10  
8
Maximum altitude  
Maximum power loss  
at ambient  
Pmax  
at ambient  
55 ºC  
6
4
12.0 W  
2
8.0 W  
65 ºC  
0
4.0 W  
75 ºC  
50  
55  
60  
65  
70  
75  
80  
85  
90  
amb  
0 W  
85 ºC  
FK PC PM PFC  
May 2009  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 3 of 8  
Film capacitors – Power Factor Correction  
PhaseCap Compact capacitors  
B25673A4202A040  
MKK440-D-20-02  
Switching voltages  
Max. 10 000 switchings per year  
Dimensional drawings  
Design data  
116 × 200 mm  
2.2 kg  
Dimensions (× l)  
Weight approx  
Impregnation  
Non PCB, Semi-dry biodegradable  
resin  
Fixing  
Threaded bolt M12  
Max. torque (Al can stud) 10 Nm  
Mounting position  
Any mounting position possible. See  
“Maintenance and Installation  
Manual” for further details.  
Terminals  
Degree of protection  
Max. torque  
Isolated terminals, IP20  
2.0 Nm  
Terminal cross section  
Maximum terminal current  
Creepage distance (min)  
Clearance (min)  
25 mm2  
60 A  
12.7 mm  
9.6 mm  
Safety  
Mechanical safety  
Max. short circuit current  
Discharge resistor time  
Overpressure disconnector  
(AFC: 10 kA)  
90 sec to 75 V or less  
Reference standards  
IEC 60831-1/2  
FK PC PM PFC  
May 2009  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 4 of 8  
Film capacitors – Power Factor Correction  
PhaseCap Compact capacitors  
B25673A4202A040  
MKK440-D-20-02  
Cautions and warnings  
In case of dents of more than 1 mm depth or any other mechanical damage, capacitors must not  
be used at all.  
This applies also in cases of oil leakages.  
To ensure the full functionality of the overpressure disconnector, elastic elements must not be  
hindered and a minimum space of 12 mm has to be kept above each capacitor.  
Do not handle the capacitor before it is discharged.  
Resonance cases must be avoided by appropriate application design in any case.  
Handle capacitors carefully, because they may still be charged even after disconnection due to  
faulty discharging devices.  
Protect the capacitor properly against over current and short circuit.  
Failure to follow cautions may result, worst case, in premature failures, bursting and fire.  
Discharging  
Capacitors must be discharged to a maximum of 10% of rated voltage before they are switched in  
again. This prevents an electric impulse discharge in the application, influences the capacitor’s  
service life and protects against electric shock. The capacitor must be discharged to 75 V or less  
within 3 minutes. There must be not any switch, fuse or any other disconnecting device in the circuit  
between the power capacitor and the discharging device. PhaseCap Compact capacitors have a pre-  
mounted ceramic discharge module; alternatively discharge reactors are available from EPCOS.  
Discharge and short circuit capacitor before handling!  
Service life expectancy  
Electrical components do not have an unlimited service life expectancy; this applies to self-healing  
capacitors too. The maximum service life expectancy may vary depending on the application the  
capacitor is used in.  
Safety  
Electrical or mechanical misapplication of capacitors may be hazardous. Personal injury or property  
damage may result from bursting of the capacitor or from expulsion of oil or melted material due to  
mechanical disruption of the capacitor.  
Ensure good, effective grounding for capacitor enclosures.  
Provide means of disconnecting and insulating a faulty component/bank.  
The terminals of capacitors, connected bus bars and cables as well as other devices may also be  
energized.  
Follow good engineering practice.  
Thermal load/over-temperature  
After installation of the capacitor it is necessary to verify that maximum hot-spot temperature is not  
exceeded at extreme service conditions.  
FK PC PM PFC  
May 2009  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 5 of 8  
Film capacitors – Power Factor Correction  
PhaseCap Compact capacitors  
B25673A4202A040  
MKK440-D-20-02  
Overpressure Disconnector  
To ensure full functionality of an overpressure disconnector, the following must be observed:  
1. The elastic elements must not be hindered, i.e.  
Connecting lines must be flexible leads (cables).  
There must be sufficient space (min. 12 mm) for expansion above the connections. This will  
enable a longitudinal extension of the can to secure the overpressure disconnector work.  
Folding beads must not be retained by clamps.  
2. The maximum allowed fault current of 10000 A in accordance with UL 810 standard must be  
assured by the application.  
3. Stress parameters of the capacitor must be within the IEC60831 specification.  
Overcurrent and short circuit protection  
Use HRC fuses or MCCBs for short circuit protection. Short circuit protection and connecting  
cables should be selected so that 1.5 times the rated capacitor current can be permanently  
handled.  
HRC fuses do not protect a capacitor against overload – they are only for short circuit protection.  
The HRC fuse rating should be 1.6 to 1.8 times rated capacitor current.  
Do not use HRC fuses to switch capacitors (risk of arcing).  
Use thermal magnetic over current relays for overload protection.  
Resonance cases  
Resonance cases must be avoided by appropriate application design in any case. Maximum total  
RMS capacitor current (incl. fundamental harmonic current) specified in technical data must not be  
exceeded.  
Re-switching vs. phase-opposition  
In case of voltage interruption, a sufficient discharge time has to be ensured to avoid phase-  
opposition and resulting high inrush currents.  
Vibration resistance  
The resistance to vibration of capacitors corresponds to IEC 68, part 2–6.  
Max. test conditions:  
Test duration  
6 h*  
Frequency range 1  
10 ... 55 Hz*  
Displacement amplitude 0.75 mm*  
*corresponding to max. 98.1 m/s or 10 g  
FK PC PM PFC  
May 2009  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 6 of 8  
Film capacitors – Power Factor Correction  
PhaseCap Compact capacitors  
B25673A4202A040  
MKK440-D-20-02  
These figures apply to the capacitor alone. Because the fixing and the terminals may influence the  
vibration properties, it is necessary to check stability when a capacitor is built in and exposed to  
vibration. Irrespective of this, you are advised not to locate capacitors where vibration amplitude  
reaches the maximum in strongly vibrating equipment.  
Mechanical protection  
The capacitor has to be installed in a way that mechanical damages and dents in the aluminum can  
are avoided.  
Grounding  
The threaded bottom stud of the capacitor has to be used for grounding. In case grounding is done  
via metal chassis that the capacitor is mounted to, the layer of varnish beneath the washer and nut  
should be removed. The maximum tightening torque is 10 Nm.  
Maintenance  
Check tightness of the connections/terminals periodically.  
Take current reading twice a year and compare with nominal current. Use a harmonic analyser or  
true effective RMS-meter.  
In case of current above the nominal current check your application for modifications.  
If a significant increase in the amount of non-linear loads has been detected, then a consultant  
has to be called in for a harmonic study.  
In case of the presence of harmonics installation of a de-tuned capacitor bank (reactors) must be  
considered.  
Check the discharge resistors/reactors and in case of doubt, check their function:  
(1) Power the capacitor up and down.  
(2) After 90 seconds the voltage between the terminals must decline to less than 75 V.  
Check the temperature of capacitors directly after operation for a longer period, but make sure  
that the capacitors have been switched off. In case of excessive temperature of individual  
capacitors, it is recommended to replace these capacitors, as this should be an indication for loss  
factor increase, which is a sign for reaching end of life.  
Storage and operating conditions  
Do not use or store capacitors in corrosive atmosphere, especially where chloride gas, sulfide gas,  
acid, alkali, salt or the like are present. In dusty environments regular maintenance and cleaning  
especially of the terminals is required to avoid conductive path between phases and/or phases  
and ground.  
Note  
For detailed information about PFC capacitors and cautions, refer to the latest version of EPCOS PFC  
Product Profile.  
FK PC PM PFC  
May 2009  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 7 of 8  
Important notes  
The following applies to all products named in this publication:  
1. Some parts of this publication contain statements about the suitability of our products for  
certain areas of application. These statements are based on our knowledge of typical  
requirements that are often placed on our products in the areas of application concerned. We  
nevertheless expressly point out that such statements cannot be regarded as binding  
statements about the suitability of our products for a particular customer application. As a  
rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them  
than the customers themselves. For these reasons, it is always ultimately incumbent on the  
customer to check and decide whether an EPCOS product with the properties described in the  
product specification is suitable for use in a particular customer application.  
2. We also point out that in individual cases, a malfunction of electronic components or failure  
before the end of their usual service life cannot be completely ruled out in the current state  
of the art, even if they are operated as specified. In customer applications requiring a very high  
level of operational safety and especially in customer applications in which the malfunction or  
failure of an electronic component could endanger human life or health (e.g. in accident  
prevention or life-saving systems), it must therefore be ensured by means of suitable design of the  
customer application or other action taken by the customer (e.g. installation of protective circuitry  
or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or  
failure of an electronic component.  
3. The warnings, cautions and product-specific notes must be observed.  
4. In order to satisfy certain technical requirements, some of the products described in this  
publication may contain substances subject to restrictions in certain jurisdictions (e.g.  
because they are classed as hazardous). Useful information on this will be found in our Material  
Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed  
questions, please contact our sales offices.  
5. We constantly strive to improve our products. Consequently, the products described in this  
publication may change from time to time. The same is true of the corresponding product  
specifications. Please check therefore to what extent product descriptions and specifications  
contained in this publication are still applicable before or when you place an order.  
We also reserve the right to discontinue production and delivery of products. Consequently,  
we cannot guarantee that all products named in this publication will always be available.  
The aforementioned does not apply in the case of individual agreements deviating from the  
foregoing for customer-specific products.  
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of  
the “General Terms of Delivery for Products and Services in the Electrical Industry”  
published by the German Electrical and Electronics Industry Association (ZVEI).  
7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DSSP, MiniBlue,  
MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, SIFERRIT, SIFI, SIKOREL,  
SilverCap, SIMDAD, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are  
trademarks registered or pending in Europe and in other countries. Further information will be  
found on the Internet at www.epcos.com/trademarks.  
Page 8 of 8  

B25673A4202A040 相关器件

型号 制造商 描述 价格 文档
B25673A4202A080 EPCOS CAPACITOR, METALLIZED FILM, POLYPROPYLENE, 92.2uF, STUD MOUNT, CAN 获取价格
B25673A4202A080 TDK Output[50Hz] = 20kvarOutput[60Hz] = 24kvar 获取价格
B25673A4202A810 EPCOS Film capacitors - Power Factor Correction 获取价格
B25673A4252A000 EPCOS Film capacitors - Power Factor Correction 获取价格
B25673A4252A040 EPCOS Film capacitors - Power Factor Correction 获取价格
B25673A4252A040 TDK Output[50Hz] = 25kvarOutput[60Hz] = 30kvar 获取价格
B25673A4252A040_09 EPCOS Film capacitors - Power Factor Correction 获取价格
B25673A4252A080 EPCOS Film Capacitors - Power Factor Correction 获取价格
B25673A4252A080 TDK Output[50Hz] = 25kvar 获取价格
B25673A4252A080_09 EPCOS Film Capacitors - Power Factor Correction 获取价格

B25673A4202A040 相关文章

  • Bourns 密封通孔金属陶瓷微调电位计产品选型手册(英文版)
    2024-09-20
    6
  • Bourns 精密环境传感器产品选型手册(英文版)
    2024-09-20
    9
  • Bourns POWrTher 负温度系数(NTC)热敏电阻手册 (英文版)
    2024-09-20
    8
  • Bourns GMOV 混合过压保护组件产品选型手册(英文版)
    2024-09-20
    6