B41896C5567M012 [EPCOS]

Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 25V, 20% +Tol, 20% -Tol, 560uF, Through Hole Mount, RADIAL LEADED, ROHS COMPLIANT;
B41896C5567M012
型号: B41896C5567M012
厂家: EPCOS    EPCOS
描述:

Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 25V, 20% +Tol, 20% -Tol, 560uF, Through Hole Mount, RADIAL LEADED, ROHS COMPLIANT

文件: 总35页 (文件大小:615K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Aluminum electrolytic capacitors  
Single-ended capacitors  
Series/Type:  
B41896  
Date:  
December 2010  
© EPCOS AG 2010. Reproduction, publication and dissemination of this publication, enclosures hereto and the  
information contained therein without EPCOS' prior express consent is prohibited.  
Single-ended capacitors  
B41896  
Up to 135 °C  
Long-life grade capacitors  
Applications  
Automotive applications  
Power supplies  
Features  
High operating temperature capability up to 135 °C  
Extra long useful life  
High ripple current capability  
Compact design  
Low ESR  
RoHS-compatible  
Construction  
Radial leads  
Charge-discharge proof, polar  
Aluminum case with insulating sleeve  
Minus pole marking on the insulating sleeve  
Case with safety vent  
Delivery mode  
Terminal configurations and packing:  
Bulk  
Taped, Ammo pack  
Cut (see chapter "Single-ended Taping, packing and lead  
configurations, Cut leads (Chapter B)")  
Kinked (see chapter "Single-ended Taping, packing and  
lead configurations, Kinked leads (Chapter B)")  
PAPR (protection against polarity reversal):  
crimped leads, J leads, bent leads  
Refer to chapter "Single-ended capacitors Taping, packing  
and lead configurations" for further details.  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 2 of 35  
B41896  
Up to 135 °C  
Specifications and characteristics in brief  
Rated voltage VR  
Surge voltage VS  
Rated capacitance CR  
10 ... 50 V DC  
1.15 VR  
180 ... 10000 µF  
Capacitance tolerance ±20% M  
Dissipation factor tan δ For capacitance higher than 1000 µF add 0.02 for every increase of  
(20 °C, 120 Hz)  
1000 µF.  
VR (V DC)  
10  
16 ... 25 35  
0.17 0.12  
50  
63  
tan δ (max.)  
0.20  
0.10  
0.15  
Leakage current Ileak  
(20 °C, 5 min)  
or 3 µA, whichever is greater  
Self-inductance ESL  
Diameter (mm)  
ESL (nH)  
12.5  
16  
26  
18  
34  
20  
Useful life  
125 °C; VR; IAC,R  
> 3500 h for d = 10 mm  
> 7000 h for d 12.5 mm  
135 °C; VR; 0.75 IAC,R > 1000 h for d = 10 mm  
> 3000 h for d 12.5 mm  
Requirements  
C/C  
tan δ  
Ileak  
≤ ±35% of initial value  
3 times initial specified limit  
initial specified limit  
Voltage endurance test  
125 °C, VR  
3500 h for d = 10 mm  
7000 h for d 12.5 mm  
Post test requirements C/C  
≤ ±30% of initial value  
2 times initial specified limit  
initial specified limit  
tan δ  
Ileak  
Vibration resistance test To IEC 60068-2-6, test Fc:  
Frequency range 10 Hz … 2 kHz, displacement amplitude max. 1.5 mm,  
acceleration max. 20 g, duration 3 × 2 h.  
Capacitor rigidly clamped by the aluminum case.  
IEC climatic category  
To IEC 60068-1: 55/125/56 (55 °C/+125 °C/56 days damp heat test)  
Sectional specification IEC 60384-4, AEC-Q200  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 3 of 35  
B41896  
Up to 135 °C  
Dimensional drawing  
With stand-off rubber seal  
Diameters (mm): 10, 12.5, 16, 18  
Dimensions and weights  
Dimensions (mm)  
Approx. weight  
d +0.5  
10  
l
a ±0.5  
5.0  
5.0  
5.0  
5.0  
5.0  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
b
g
20 +2.0  
20 +2.0  
25 +2.0  
30 +2.0  
40 +2.0  
20 +2.0  
25 +2.0  
31.5 +2.0  
35.5 +2.0  
20 +2.0  
25 +2.0  
31.5 +2.0  
35 +2.0  
40 +2.5  
0.60 ±0.05  
0.60 ±0.05  
0.60 ±0.05  
0.80 ±0.05  
0.80 ±0.05  
0.80 ±0.05  
0.80 ±0.05  
0.80 ±0.05  
0.80 ±0.05  
0.80 ±0.1  
0.80 ±0.1  
0.80 ±0.1  
0.80 ±0.1  
0.80 ±0.1  
2.6  
3.6  
4.5  
5.3  
7.4  
5.5  
7.5  
7.8  
9.2  
8.0  
9.0  
11.0  
13.0  
16.0  
12.5  
12.5  
12.5  
12.5  
16  
16  
16  
16  
18  
18  
18  
18  
18  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 4 of 35  
B41896  
Up to 135 °C  
Overview of available types  
VR (V DC)  
10  
16  
25  
35  
50  
Case dimensions d × l (mm)  
CR (µF)  
180  
10 × 20  
10 × 20  
12.5 × 20  
12.5 × 20  
12.5 × 25  
220  
270  
10 × 20  
10 × 20  
12.5 × 20  
12.5 × 20  
330  
390  
470  
10 × 20  
12.5 × 25  
16 × 20  
560  
680  
10 × 20  
10 × 20  
12.5 × 25  
12.5 × 25  
16 × 20  
16 × 25  
18 × 20  
820  
10 × 20  
10 × 20  
10 × 20  
12.5 × 20  
12.5 × 20  
16 × 20  
16 × 31.5  
16 × 31.5  
1000  
12.5 × 25  
16 × 20  
12.5 × 40  
16 × 25  
18 × 20  
1200  
12.5 × 20  
12.5 × 20  
12.5 × 25  
16 × 20  
16 × 25  
18 × 20  
18 × 31.5  
1500  
1800  
12.5 × 20  
12.5 × 20  
12.5 × 25  
12.5 × 25  
16 × 31.5  
16 × 31.5  
18 × 35  
18 × 40  
12.5 × 40  
16 × 25  
18 × 20  
2000  
2200  
16 × 35.5  
18 × 35  
12.5 × 25  
16 × 20  
16 × 25  
12.5 × 30  
16 × 20  
16 × 31.5  
18 × 25  
2700  
3300  
3900  
16 × 25  
18 × 20  
16 × 31.5  
18 × 40  
16 × 31.5  
16 × 35.5  
18 × 31.5  
16 × 25  
18 × 20  
16 × 31.5  
18 × 35  
4700  
5600  
6800  
8200  
10000  
16 × 31.5  
16 × 31.5  
18 × 31.5  
18 × 35  
18 × 31.5  
18 × 35  
18 × 40  
18 × 40  
18 × 40  
Other voltage and capacitance ratings are available upon request.  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 5 of 35  
B41896  
Up to 135 °C  
Technical data and ordering codes  
CR  
Case  
dimensions  
d × l  
ESRmax  
10 kHz  
40 °C  
ESRmax  
10 kHz  
20 °C  
Zmax  
IAC,R  
Ordering code  
(composition see  
below)  
120 Hz  
20 °C  
µF  
100 kHz 100 kHz  
20 °C  
125 °C  
mA  
mm  
VR = 10 V DC  
820  
1000  
1200  
1500  
1800  
2200  
2700  
3300  
3900  
3900  
4700  
5600  
6800  
8200  
10000  
10 × 20  
0.592  
0.592  
0.484  
0.484  
0.484  
0.285  
0.299  
0.238  
0.238  
0.273  
0.185  
0.185  
0.178  
0.178  
0.150  
0.074  
0.074  
0.061  
0.061  
0.061  
0.041  
0.037  
0.030  
0.030  
0.034  
0.023  
0.023  
0.022  
0.022  
0.019  
0.062  
0.062  
0.055  
0.055  
0.055  
0.038  
0.034  
0.026  
0.026  
0.031  
0.022  
0.022  
0.021  
0.019  
0.016  
1205  
1205  
1820  
1820  
1820  
2280  
2280  
2860  
2860  
2490  
3160  
3160  
3500  
3840  
4230  
B41896C3827M***  
B41896C3108M***  
B41896C3128M***  
B41896C3158M***  
B41896C3188M***  
B41896C3228M***  
B41896C3278M***  
B41896C3338M***  
B41896C3398M***  
B41896D3398M***  
B41896C3478M***  
B41896C3568M***  
B41896C3688M***  
B41896C3828M***  
B41896C3109M***  
10 × 20  
12.5 × 20  
12.5 × 20  
12.5 × 20  
12.5 × 25  
16 × 20  
16 × 25  
16 × 25  
18 × 20  
16 × 31.5  
16 × 31.5  
18 × 31.5  
18 × 35  
18 × 40  
Composition of ordering code  
*** = Version  
000 = for standard leads, bulk  
001 = for kinked leads, bulk (for d × l = 10 × 20 ... 12.5 × 25 mm and 16 ... 18 mm)  
002 = for cut leads, bulk (for 10 ... 18 mm, excluding d × l = 12.5 × 30/40 mm)  
003 = for crimped leads, blister (for 16 ... 18 mm)  
004 = for J leads, blister (for 10 ... 18 mm, excluding d × l = 12.5 × 30/40 and 18 × 40 mm)  
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for d × l = 10 × 20 ... 12.5 × 25 mm)  
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d × l = 16 × 20 ... 16 × 31.5 mm and  
18 × 20 ... 18 × 31.5 mm)  
012 = for bent 90° leads, blister (for 16 ... 18 mm)  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 6 of 35  
B41896  
Up to 135 °C  
Technical data and ordering codes  
CR  
Case  
dimensions  
d × l  
ESRmax  
10 kHz  
40 °C  
ESRmax  
10 kHz  
20 °C  
Zmax  
IAC,R  
Ordering code  
(composition see  
below)  
120 Hz  
20 °C  
µF  
100 kHz 100 kHz  
20 °C  
125 °C  
mA  
mm  
VR = 16 V DC  
820  
1000  
1200  
1500  
1800  
2200  
2200  
2700  
2700  
3300  
3900  
4700  
5600  
6800  
10 × 20  
0.592  
0.484  
0.484  
0.285  
0.285  
0.238  
0.299  
0.238  
0.273  
0.185  
0.185  
0.178  
0.178  
0.150  
0.074  
0.061  
0.061  
0.041  
0.041  
0.030  
0.037  
0.030  
0.034  
0.023  
0.023  
0.022  
0.022  
0.019  
0.062  
0.055  
0.055  
0.038  
0.038  
0.026  
0.034  
0.026  
0.031  
0.022  
0.022  
0.021  
0.019  
0.016  
1205  
1820  
1820  
2280  
2280  
2860  
2280  
2860  
2490  
3160  
3160  
3500  
3840  
4230  
B41896C4827M***  
B41896C4108M***  
B41896C4128M***  
B41896C4158M***  
B41896C4188M***  
B41896C4228M***  
B41896D4228M***  
B41896C4278M***  
B41896D4278M***  
B41896C4338M***  
B41896C4398M***  
B41896C4478M***  
B41896C4568M***  
B41896C4688M***  
12.5 × 20  
12.5 × 20  
12.5 × 25  
12.5 × 25  
12.5 × 30  
16 × 20  
16 × 25  
18 × 20  
16 × 31.5  
16 × 31.5  
18 × 31.5  
18 × 35  
18 × 40  
Composition of ordering code  
*** = Version  
000 = for standard leads, bulk  
001 = for kinked leads, bulk (for d × l = 10 × 20 ... 12.5 × 25 mm and 16 ... 18 mm)  
002 = for cut leads, bulk (for 10 ... 18 mm, excluding d × l = 12.5 × 30/40 mm)  
003 = for crimped leads, blister (for 16 ... 18 mm)  
004 = for J leads, blister (for 10 ... 18 mm, excluding d × l = 12.5 × 30/40 and 18 × 40 mm)  
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for d × l = 10 × 20 ... 12.5 × 25 mm)  
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d × l = 16 × 20 ... 16 × 31.5 mm and  
18 × 20 ... 18 × 31.5 mm)  
012 = for bent 90° leads, blister (for 16 ... 18 mm)  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 7 of 35  
B41896  
Up to 135 °C  
Technical data and ordering codes  
CR  
Case  
dimensions  
d × l  
ESRmax  
10 kHz  
40 °C  
ESRmax  
10 kHz  
20 °C  
Zmax  
IAC,R  
Ordering code  
(composition see  
below)  
120 Hz  
20 °C  
µF  
100 kHz 100 kHz  
20 °C  
125 °C  
mA  
mm  
VR = 25 V DC  
470  
560  
680  
10 × 20  
0.592  
0.592  
0.592  
0.484  
0.285  
0.299  
0.285  
0.299  
0.181  
0.238  
0.273  
0.185  
0.229  
0.185  
0.180  
0.178  
0.178  
0.150  
0.074  
0.074  
0.074  
0.061  
0.041  
0.037  
0.041  
0.037  
0.023  
0.030  
0.034  
0.023  
0.029  
0.023  
0.022  
0.022  
0.022  
0.019  
0.062  
0.062  
0.062  
0.055  
0.038  
0.034  
0.038  
0.034  
0.021  
0.026  
0.031  
0.022  
0.025  
0.022  
0.020  
0.021  
0.019  
0.016  
1205  
1205  
1205  
1820  
2280  
2280  
2280  
2280  
3340  
2860  
2490  
3160  
3010  
3160  
3467  
3500  
3840  
4230  
B41896C5477M***  
B41896C5567M***  
B41896C5687M***  
B41896C5827M***  
B41896C5108M***  
B41896D5108M***  
B41896C5128M***  
B41896C5158M***  
B41896C5188M***  
B41896D5188M***  
B41896E5188M***  
B41896C5228M***  
B41896D5228M***  
B41896C5278M***  
B41896D5338M***  
B41896C5338M***  
B41896C5398M***  
B41896C5478M***  
10 × 20  
10 × 20  
12.5 × 20  
12.5 × 25  
16 × 20  
12.5 × 25  
16 × 20  
12.5 × 40  
16 × 25  
18 × 20  
16 × 31.5  
18 × 25  
16 × 31.5  
16 × 35.5  
18 × 31.5  
18 × 35  
18 × 40  
820  
1000  
1000  
1200  
1500  
1800  
1800  
1800  
2200  
2200  
2700  
3300  
3300  
3900  
4700  
Composition of ordering code  
*** = Version  
000 = for standard leads, bulk  
001 = for kinked leads, bulk (for d × l = 10 × 20 ... 12.5 × 25 mm and 16 ... 18 mm)  
002 = for cut leads, bulk (for 10 ... 18 mm, excluding d × l = 12.5 × 30/40 mm)  
003 = for crimped leads, blister (for 16 ... 18 mm)  
004 = for J leads, blister (for 10 ... 18 mm, excluding d × l = 12.5 × 30/40 and 18 × 40 mm)  
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for d × l = 10 × 20 ... 12.5 × 25 mm)  
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d × l = 16 × 20 ... 16 × 31.5 mm and  
18 × 20 ... 18 × 31.5 mm)  
012 = for bent 90° leads, blister (for 16 ... 18 mm)  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 8 of 35  
B41896  
Up to 135 °C  
Technical data and ordering codes  
CR  
Case  
dimensions  
d × l  
ESRmax  
10 kHz  
40 °C  
ESRmax  
10 kHz  
20 °C  
Zmax  
IAC,R  
Ordering code  
(composition see  
below)  
120 Hz  
20 °C  
µF  
100 kHz 100 kHz  
20 °C  
125 °C  
mA  
mm  
VR = 35 V DC  
270  
330  
390  
470  
560  
10 × 20  
0.592  
0.592  
0.484  
0.484  
0.285  
0.285  
0.299  
0.181  
0.238  
0.273  
0.238  
0.273  
0.185  
0.185  
0.180  
0.178  
0.150  
0.074  
0.074  
0.061  
0.061  
0.041  
0.041  
0.037  
0.023  
0.030  
0.034  
0.030  
0.034  
0.023  
0.023  
0.022  
0.022  
0.019  
0.062  
0.062  
0.055  
0.055  
0.038  
0.038  
0.034  
0.021  
0.026  
0.031  
0.026  
0.031  
0.022  
0.022  
0.020  
0.019  
0.016  
1205  
1205  
1820  
1820  
2280  
2280  
2280  
3340  
2860  
2490  
2860  
2490  
3160  
3160  
3467  
3840  
4230  
B41896C7277M***  
B41896C7337M***  
B41896C7397M***  
B41896C7477M***  
B41896C7567M***  
B41896C7687M***  
B41896C7827M***  
B41896C7108M***  
B41896D7108M***  
B41896E7108M***  
B41896C7128M***  
B41896D7128M***  
B41896C7158M***  
B41896C7188M***  
B41896C7208M***  
B41896C7228M***  
B41896C7278M***  
10 × 20  
12.5 × 20  
12.5 × 20  
12.5 × 25  
12.5 × 25  
16 × 20  
12.5 × 40  
16 × 25  
18 × 20  
16 × 25  
18 × 20  
16 × 31.5  
16 × 31.5  
16 × 35.5  
18 × 35  
18 × 40  
680  
820  
1000  
1000  
1000  
1200  
1200  
1500  
1800  
2000  
2200  
2700  
Composition of ordering code  
*** = Version  
000 = for standard leads, bulk  
001 = for kinked leads, bulk (for d × l = 10 × 20 ... 12.5 × 25 mm and 16 ... 18 mm)  
002 = for cut leads, bulk (for 10 ... 18 mm, excluding d × l = 12.5 × 30/40 mm)  
003 = for crimped leads, blister (for 16 ... 18 mm)  
004 = for J leads, blister (for 10 ... 18 mm, excluding d × l = 12.5 × 30/40 and 18 × 40 mm)  
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for d × l = 10 × 20 ... 12.5 × 25 mm)  
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d × l = 16 × 20 ... 16 × 31.5 mm and  
18 × 20 ... 18 × 31.5 mm)  
012 = for bent 90° leads, blister (for 16 ... 18 mm)  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 9 of 35  
B41896  
Up to 135 °C  
Technical data and ordering codes  
CR  
Case  
dimensions  
d × l  
ESRmax  
10 kHz  
40 °C  
ESRmax  
10 kHz  
20 °C  
Zmax  
IAC,R  
Ordering code  
(composition see  
below)  
120 Hz  
20 °C  
µF  
100 kHz 100 kHz  
20 °C  
125 °C  
mA  
mm  
VR = 50 V DC  
180  
220  
270  
330  
390  
470  
470  
560  
680  
680  
820  
1000  
1200  
1500  
1800  
10 × 20  
0.592  
0.592  
0.484  
0.484  
0.352  
0.352  
0.299  
0.299  
0.238  
0.273  
0.185  
0.185  
0.178  
0.178  
0.150  
0.074  
0.074  
0.061  
0.061  
0.044  
0.044  
0.037  
0.037  
0.030  
0.034  
0.023  
0.023  
0.022  
0.022  
0.019  
0.062  
0.062  
0.055  
0.055  
0.041  
0.041  
0.034  
0.034  
0.026  
0.031  
0.022  
0.022  
0.021  
0.019  
0.016  
1205  
1205  
1820  
1820  
2280  
2280  
2280  
2280  
2860  
2490  
3160  
3160  
3500  
3840  
4230  
B41896C6187M***  
B41896C6227M***  
B41896C6277M***  
B41896C6337M***  
B41896D6397M***  
B41896E6477M***  
B41896D6477M***  
B41896C6567M***  
B41896C6687M***  
B41896D6687M***  
B41896C6827M***  
B41896C6108M***  
B41896C6128M***  
B41896C6158M***  
B41896C6188M***  
10 × 20  
12.5 × 20  
12.5 × 20  
12.5 × 25  
12.5 × 25  
16 × 20  
16 × 20  
16 × 25  
18 × 20  
16 × 31.5  
16 × 31.5  
18 × 31.5  
18 × 35  
18 × 40  
Composition of ordering code  
*** = Version  
000 = for standard leads, bulk  
001 = for kinked leads, bulk (for d × l = 10 × 20 ... 12.5 × 25 mm and 16 ... 18 mm)  
002 = for cut leads, bulk (for 10 ... 18 mm, excluding d × l = 12.5 × 30/40 mm)  
003 = for crimped leads, blister (for 16 ... 18 mm)  
004 = for J leads, blister (for 10 ... 18 mm, excluding d × l = 12.5 × 30/40 and 18 × 40 mm)  
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for d × l = 10 × 20 ... 12.5 × 25 mm)  
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d × l = 16 × 20 ... 16 × 31.5 mm and  
18 × 20 ... 18 × 31.5 mm)  
012 = for bent 90° leads, blister (for 16 ... 18 mm)  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 10 of 35  
B41896  
Up to 135 °C  
Useful life  
depending on ambient temperature TA under ripple current operating conditions1)  
d = 10 mm  
Useful life  
depending on ambient temperature TA under ripple current operating conditions1)  
d 12.5 mm  
1) Refer to chapter "General technical information, 5.3 Calculation of useful life" for an explanation on how to interpret the useful life  
graphs.  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 11 of 35  
B41896  
Up to 135 °C  
Frequency factor of permissible ripple current IAC versus frequency f  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 12 of 35  
B41896  
Up to 135 °C  
Taping, packing and lead configurations  
Taping  
Single-ended capacitors are available taped in Ammo pack from diameter 4 to 18 mm as follows:  
Lead spacing F = 2.0 mm ( d = 4 … 5 mm)  
Lead spacing F = 2.5 mm ( d = 4 … 6.3 mm)  
Lead spacing F = 3.5 mm ( d = 8 mm)  
Lead spacing F = 5.0 mm ( d = 4 … 12.5 mm)  
Lead spacing F = 7.5 mm ( d = 16 ... 18 mm).  
Lead spacing 2.0 mm ( d = 4 ... 5 mm)  
Last 3 digits of ordering code: 016  
Dimensions in mm  
d
F
H
W
W0  
W1  
9.0  
W2  
3.0  
P
P0  
P1  
I1  
t
h  
D0  
4 ... 5 2.0  
+0.8  
0.2  
18.5 18.0 7.0  
12.7 12.7 5.10 1.0  
0.7  
1
4.0  
±0.75 ±0.5 min. ±0.5 max. ±1.0 ±0.3 ±0.7 max. ±0.2 ±1.0 ±0.2  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 13 of 35  
B41896  
Up to 135 °C  
Lead spacing 2.5 mm ( d = 4 ... 6.3 mm)  
Last 3 digits of ordering code: 007  
Dimensions in mm  
d
F
H
W
W0  
W1  
W2  
H0  
P
P0  
P1  
I1  
t
h  
D0  
4 ... 6.3 2.5 18.5 18.0 5.5 9.0 1.5 16.0 12.7 12.7 5.1 1.0 0.7 1.0 4.0  
Toler-  
rance  
+0.8  
0.2  
±0.75 ±0.5 min. ±0.5 max. ±0.5 ±1.0 ±0.2 ±0.5 max. ±0.2 max. ±0.2  
Lead spacing 3.5 mm ( d = 8 mm)  
Last 3 digits of ordering code: 006  
Dimensions in mm  
d
F
H
W
W0  
W1  
9.0  
W2  
3.0  
P
P0  
P1  
I1  
t
h  
D0  
8
3.5  
18.5 18.0 10  
12.7 12.7 4.6  
1.0  
0.7  
1.0  
4.0  
Toler- +0.8  
ance 0.2  
±1.0 ±0.5 min. ±0.5 max. ±1.0 ±0.3 ±0.6 max. ±0.2 max. ±0.2  
Leads can also run straight through the taping area. Taping is available up to dimensions  
d × l = 8 × 15 mm.  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 14 of 35  
B41896  
Up to 135 °C  
Lead spacing 5.0 mm ( d = 4 ... 8 mm)  
Last 3 digits of ordering code: 008  
Lead spacing 5.0 mm ( d = 10 ... 12.5 mm)  
Last 3 digits of ordering code: 008  
Dimensions in mm  
d
F
H
W
W0 W1 W2  
H0  
P
P0  
P1  
I1  
t
h  
D0  
4 ...  
6.3  
5.0  
18.5 18.0 5.5 9.0 1.5  
16.0 12.7 12.7 3.85 1.0  
0.6  
1.0  
4.0  
8
20.0  
19.0 18.0 12.5 9.0 1.5  
19.0  
12.5  
10.0  
16.0 12.7 12.7 3.85  
10  
12.5  
5.0  
12.7 12.7 3.85 1.0  
15.0 15.0 5.0  
0.6  
1.0  
4.0  
Toler-  
ance  
+0.8  
0.2  
+0.3  
0.2  
±0.75 ±0.5 min. ±0.5 max. ±0.5 ±1.0 ±0.2 ±0.5 max.  
max. ±0.2  
Taping is available up to dimensions d × l = 10 × 31.5 mm and 12.5 × 25 mm.  
Taping is not available for d × l = 8 × 20 mm.  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 15 of 35  
B41896  
Up to 135 °C  
Lead spacing 7.5 mm ( d = 16 ...18 mm)  
Last 3 digits of ordering code: 009  
Dimensions in mm  
d
F
H
W
W0  
W1  
W2  
1.5  
P
P0  
P1  
I1  
t
P h D0  
4.0  
16  
18  
7.5 18.5 18.0 12.5 9.0  
30.0 15.0 3.75 1.0  
0.7  
0
0
Toler-  
ance  
0.5  
+0.75  
±0.8  
±0.5 min. ±0.5 max. ±1.0 ±0.2 ±0.5 max. ±0.2 ±1.0 ±1.0 ±0.2  
Taping is available up to dimensions d × l = 16 × 31.5 mm and 18 × 31.5 mm.  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 16 of 35  
B41896  
Up to 135 °C  
Cut or kinked leads  
Single-ended capacitors are available with cut or kinked leads. Other lead configurations also  
available upon request.  
Cut leads (Chapter A)  
Available for series B41002, B41022, B41044, B41827, B41828, B43044, B43082, B43086,  
B43088, B43827, B43828.  
Last 3 digits of ordering code: 002  
Case size d x l (mm) Dimensions  
Case size d x l (mm) Dimensions  
(mm)  
(mm)  
a ±0.5  
a ±0.5  
4
5
5
x 7  
1.5  
2.0  
2.0  
2.5  
2.5  
3.5  
3.5  
3.5  
3.5  
5.0  
5.0  
5.0  
5.0  
5.0  
12.5 x 16  
12.5 x 20  
12.5 x 25  
12.5 x 31.5  
12.5 x 35.5  
12.5 x 40  
16 x 20  
16 x 25  
16 x 31.5  
16 x 35.5  
16 x 40  
18 x 20  
18 x 25  
18 x 31.5  
18 x 35.5  
18 x 40  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
x 7  
x 11  
6.3 x 7  
6.3 x 11  
8
8
8
8
x 7  
x 11.5  
x 15  
x 20  
10 x 12.5  
10 x 16  
10 x 20  
10 x 25  
10 x 31.5  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 17 of 35  
B41896  
Up to 135 °C  
Cut leads (Chapter B)  
Available for series B41858, B41859, B41863, B41866, B41868, B41888, B41890, B41896,  
B42824, B42851, B43866, B43867, B43890, B43896.  
Last 3 digits of ordering code: 002  
With stand-off rubber seal  
Case size  
d × l (mm)  
10 × 12.5  
10 × 16  
Dimensions (mm)  
a ±0.5  
5.0  
5.0  
5.0  
5.0  
5.0  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
10 × 20  
12.5 × 20  
12.5 × 25  
16 × 20  
With flat rubber seal  
16 × 25  
16 × 31.5  
16 × 35.5  
18 × 20  
18 × 25  
18 × 31.5  
18 × 35  
18 × 40  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 18 of 35  
B41896  
Up to 135 °C  
Kinked leads (Chapter A)  
Available for series B41002, B41022, B41044, B41827, B41828, B43044, B43082, B43086,  
B43088, B43827, B43828.  
Last 3 digits of ordering code: 001  
Case size d x l (mm) Dimensions  
Case size d x l (mm) Dimensions  
(mm)  
(mm)  
a ±0.5  
a ±0.5  
4
5
5
x 7  
1.5  
2.0  
2.0  
2.5  
2.5  
3.5  
3.5  
3.5  
3.5  
5.0  
5.0  
5.0  
5.0  
5.0  
12.5 x 16  
12.5 x 20  
12.5 x 25  
12.5 x 31.5  
12.5 x 35.5  
12.5 x 40  
16 x 20  
16 x 25  
16 x 31.5  
16 x 35.5  
16 x 40  
18 x 20  
18 x 25  
18 x 31.5  
18 x 35.5  
18 x 40  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
x 7  
x 11  
6.3 x 7  
6.3 x 11  
8
8
8
8
x 7  
x 11.5  
x 15  
x 20  
10 x 12.5  
10 x 16  
10 x 20  
10 x 25  
10 x 31.5  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 19 of 35  
B41896  
Up to 135 °C  
Kinked leads (Chapter B)  
Available for series B41858, B41859, B41863, B41866, B41868, B41888, B41890, B41896,  
B42824, B42851, B43866, B43867, B43890, B43896.  
Last 3 digits of ordering code: 001  
With stand-off rubber seal  
Case size  
d × l (mm)  
10 × 20  
Dimensions (mm)  
a ±0.5  
5.0  
5.0  
5.0  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
12.5 × 20  
12.5 × 25  
16 × 20  
16 × 25  
16 × 31.5  
16 × 35.5  
18 × 20  
18 × 25  
18 × 31.5  
18 × 35  
18 × 40  
With flat rubber seal  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 20 of 35  
B41896  
Up to 135 °C  
PAPR leads (Protection Against Polarity Reversal)  
These lead configurations ensure correct placement of the capacitor on the PCB with regard to  
polarity. PAPR leads are available for diameters from 10 mm up to 18 mm.  
There are three configurations available: Crimped leads, J leads, bent 90° leads  
Available for series B41858, B41859, B41863, B41866, B41868, B41888, B41890, B41896,  
B42824, B42851, B43866, B43867, B43890, B43896.  
Crimped leads  
Last 3 digits of ordering code: 003  
With stand-off rubber seal  
With flat rubber seal  
Suggestion for PCB hole diameter  
Case size  
d × l (mm)  
16 × 20  
Dimensions (mm)  
B ±0.2  
1.5  
C ±0.5  
3.0  
D ±0.1  
E ±0.1  
0.3  
a ±0.5  
b
1.3  
1.3  
1.3  
1.3  
1.3  
1.3  
1.3  
1.3  
1.3  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
0.8 ±0.05  
0.8 ±0.05  
0.8 ±0.05  
0.8 ±0.05  
0.8 ±0.1  
0.8 ±0.1  
0.8 ±0.1  
0.8 ±0.1  
0.8 ±0.1  
16 × 25  
1.5  
3.0  
0.3  
16 × 31.5  
16 × 35.5  
18 × 20  
1.5  
3.0  
0.3  
1.5  
3.0  
0.3  
1.5  
3.0  
0.3  
18 × 25  
1.5  
3.0  
0.3  
18 × 31.5  
18 × 35  
1.5  
3.0  
0.3  
1.5  
3.0  
0.3  
18 × 40  
1.5  
3.0  
0.3  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 21 of 35  
B41896  
Up to 135 °C  
J leads  
Last 3 digits of ordering code: 004  
Suggestion for PCB hole diameter  
Case size  
d × l (mm)  
10 × 12.5  
10 × 16  
Dimensions (mm)  
C ±0.5  
3.2  
3.2  
3.2  
3.2  
3.2  
3.5  
3.5  
3.5  
3.5  
3.5  
3.5  
3.5  
3.5  
E ±0.5  
J ±0.2  
1.2  
1.2  
1.2  
1.2  
1.2  
1.6  
1.6  
1.6  
1.6  
1.6  
1.6  
1.6  
1.6  
a ±0.5  
5.0  
5.0  
5.0  
5.0  
5.0  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
b
0.7  
0.7  
0.7  
0.7  
0.7  
0.7  
0.7  
0.7  
0.7  
0.7  
0.7  
0.7  
0.7  
0.6 ±0.05  
0.6 ±0.05  
0.6 ±0.05  
0.6 ±0.05  
0.6 ±0.05  
0.8 ±0.05  
0.8 ±0.05  
0.8 ±0.05  
0.8 ±0.05  
0.8 ±0.1  
0.8 ±0.1  
0.8 ±0.1  
0.8 ±0.1  
10 × 20  
12.5 × 20  
12.5 × 25  
16 × 20  
16 × 25  
16 × 31.5  
16 × 35.5  
18 × 20  
18 × 25  
18 × 31.5  
18 × 35  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 22 of 35  
B41896  
Up to 135 °C  
Bent 90° leads for horizontal mounting pinning  
Last 3 digits of ordering code: 012  
Case size  
d × l (mm)  
16 × 20  
Dimensions (mm)  
C ±0.5  
4.0  
E ±0.5  
F ±0.5  
12.0  
12.0  
12.0  
12.0  
13.0  
13.0  
13.0  
13.0  
13.0  
a ±0.5  
b
4.0  
4.0  
4.0  
4.0  
4.0  
4.0  
4.0  
4.0  
4.0  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
0.8 ±0.05  
0.8 ±0.05  
0.8 ±0.05  
0.8 ±0.05  
0.8 ±0.1  
0.8 ±0.1  
0.8 ±0.1  
0.8 ±0.1  
0.8 ±0.1  
16 × 25  
4.0  
16 × 31.5  
16 × 35.5  
18 × 20  
4.0  
4.0  
4.0  
18 × 25  
4.0  
18 × 31.5  
18 × 35  
4.0  
4.0  
18 × 40  
4.0  
Bent leads for diameter 12.5 mm available upon request.  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 23 of 35  
B41896  
Up to 135 °C  
Packing units and box dimensions  
Ammo pack  
Valid for series B41002, B41022, B41044, B41827, B41828, B43044, B43082, B43086, B43088,  
B43827, B43828.  
Case size  
d × l  
Dimensions (mm)  
Packing  
units  
mm  
Amax  
330  
330  
330  
330  
330  
330  
330  
330  
330  
330  
330  
341  
341  
320  
315  
315  
315  
315  
Bmax  
50  
50  
50  
50  
50  
50  
50  
50  
50  
54  
58  
60  
65  
65  
65  
65  
65  
65  
Cmax  
196  
226  
226  
286  
286  
246  
246  
246  
196  
196  
196  
272  
272  
270  
275  
275  
275  
275  
pcs.  
4 × 7  
2000  
2000  
2000  
2000  
2000  
1000  
1000  
500  
5 × 7  
5 × 11  
6.3 × 7  
6.3 × 11  
8 × 7  
8 × 11.5  
8 × 15  
10 × 12.5  
10 × 16  
10 × 20  
12.5 × 20  
12.5 × 25  
16 × 25  
16 × 31.5  
18 × 20  
18 × 25  
18 × 31.5  
500  
500  
500  
500  
500  
300  
300  
250  
250  
250  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 24 of 35  
B41896  
Up to 135 °C  
Ammo pack  
Valid for series B41858, B41859, B41863, B41866, B41868, B41888, B41890, B41896, B42824,  
B42851, B43866, B43867, B43890, B43896.  
Case size  
d × l  
Dimensions (mm)  
Packing  
units  
mm  
Amax  
345  
345  
345  
345  
345  
345  
315  
315  
315  
315  
315  
315  
Bmax  
55  
55  
60  
60  
65  
65  
65  
65  
65  
65  
65  
65  
Cmax  
240  
280  
200  
200  
280  
280  
275  
275  
275  
275  
275  
275  
pcs.  
8 × 11.5  
10 × 12.5  
10 × 16  
1000  
750  
500  
500  
500  
500  
300  
300  
300  
250  
250  
250  
10 × 20  
12.5 × 20  
12.5 × 25  
16 × 20  
16 × 25  
16 × 31.5  
18 × 20  
18 × 25  
18 × 31.5  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 25 of 35  
B41896  
Up to 135 °C  
Overview of packing units and code numbers for case sizes 4 x 7 ... 16 x 40  
Valid for series B41002, B41022, B41044, B41827, B41828, B43044, B43082, B43086, B43088,  
B43827, B43828.  
Case size  
d x l  
mm  
Standard,  
bulk  
pcs.  
Taped,  
Ammo pack  
pcs.  
Kinked leads, Cut leads,  
bulk  
pcs.  
bulk  
pcs.  
4
5
5
x 7  
10000  
7500  
5000  
5000  
5000  
5000  
2500  
2000  
1500  
2000  
1500  
1000  
1000  
750  
2000  
2000  
2000  
2000  
2000  
1000  
1000  
1000  
15000  
10000  
10000  
10000  
5000  
5000  
4000  
2500  
2000  
2500  
2000  
1500  
1250  
1000  
500  
15000  
10000  
10000  
10000  
5000  
5000  
4000  
2500  
2000  
2500  
2000  
1500  
1250  
1000  
500  
x 7  
x 11  
6.3 x 7  
6.3 x 11  
8
8
8
8
x 7  
x 11.5  
x 15  
x 20  
10 x 12.5  
10 x 16  
10 x 20  
10 x 25  
12.5 x 16  
12.5 x 20  
12.5 x 25  
12.5 x 31.5  
12.5 x 35.5  
12.5 x 40  
16 x 20  
16 x 25  
16 x 31.5  
16 x 35.5  
16 x 40  
500  
500  
500  
500  
500  
500  
500  
750  
750  
500  
500  
500  
750  
750  
500  
750  
750  
500  
750  
750  
375  
300  
300  
300  
500  
500  
375  
500  
500  
250  
375  
375  
250  
375  
375  
250  
375  
375  
The last three  
digits of the  
complete  
ordering code  
state the lead  
configuration  
000  
Code  
F (mm) d (mm)  
001  
002  
006  
007  
008  
009  
016  
3.5  
2.5  
5.0  
7.5  
2.0  
8
4 ... 6.3  
4 ... 12.5  
16 ... 18  
4 ... 5  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 26 of 35  
B41896  
Up to 135 °C  
Overview of packing units and code numbers for case sizes 18 x 20 ... 18 x 40  
Valid for series B41002, B41022, B41044, B41827, B41828, B43044, B43082, B43086, B43088,  
B43827, B43828.  
Case size  
d x l  
mm  
Standard,  
bulk  
pcs.  
Taped,  
Ammo pack  
pcs.  
Kinked leads, Cut leads,  
bulk  
pcs.  
bulk  
pcs.  
18 x 20  
18 x 25  
18 x 31.5  
18 x 35.5  
18 x 40  
250  
250  
250  
250  
250  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
250  
250  
250  
The last three  
digits of the  
complete  
000  
Code  
009  
F (mm) d (mm)  
7.5 16 ... 18  
001  
002  
ordering code  
state the lead  
configuration  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 27 of 35  
B41896  
Up to 135 °C  
Overview of packing units and code numbers for case sizes 8 × 11.5 ... 16 × 35.5  
Valid for series B41858, B41859, B41863, B41866, B41868, B41888, B41890, B41896, B42824,  
B42851, B43866, B43867, B43890, B43896.  
PAPR  
Case size  
d × l  
Stan- Taped,  
dard, Ammo pack  
bulk  
Kinked Cut  
Crimped J leads, Bent 90°  
leads,  
bulk  
leads, leads,  
blister leads,  
bulk  
pcs.  
blister  
pcs.  
blister  
pcs.  
mm  
pcs.  
pcs.  
pcs.  
pcs.  
8 × 11.5  
10 × 12.5  
10 × 16  
1000 1000  
1000 750  
1000 500  
1000  
1000  
500  
350  
500  
675  
675  
500  
300  
225  
10 × 20  
500  
350  
250  
200  
175  
175  
250  
250  
200  
100  
500  
500  
350  
500  
1)  
1)  
12.5 × 20  
12.5 × 25  
12.5 × 30  
12.5 × 35  
12.5 × 40  
16 × 20  
500  
500  
300  
200  
200  
250  
100  
001  
200  
200  
250  
100  
002  
200  
200  
344  
150  
003  
200  
200  
344  
150  
004  
120  
120  
120  
150  
012  
16 × 25  
300  
16 × 31.5  
16 × 35.5  
300  
The last three 000  
digits of the  
complete  
ordering code  
state the lead  
configuration  
Code F (mm) d (mm)  
3.5  
5
7.5  
8
006  
008  
009  
5...12.5  
16...18  
1) Available upon request  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 28 of 35  
B41896  
Up to 135 °C  
Overview of packing units and code numbers for case sizes 18 × 20 ... 18 × 40  
Valid for series B41858, B41859, B41863, B41866, B41868, B41888, B41890, B41896, B42824,  
B42851, B43866, B43867, B43890, B43896.  
PAPR  
Case size  
d × l  
Stan- Taped,  
dard, Ammo pack  
bulk  
Kinked Cut  
Crimped J leads, Bent 90°  
leads,  
bulk  
leads, leads,  
blister leads,  
bulk  
pcs.  
175  
150  
100  
100  
100  
002  
blister  
pcs.  
200  
200  
150  
150  
120  
003  
blister  
pcs.  
120  
120  
120  
150  
72  
mm  
pcs.  
175  
150  
100  
100  
125  
pcs.  
pcs.  
pcs.  
200  
200  
150  
150  
18 × 20  
18 × 25  
18 × 31.5  
18 × 35  
18 × 40  
250  
175  
150  
100  
100  
100  
001  
250  
250  
The last three 000  
digits of the  
Code F (mm) d (mm)  
004  
012  
7.5  
16...18  
009  
complete  
ordering code  
state the lead  
configuration  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 29 of 35  
B41896  
Up to 135 °C  
Cautions and warnings  
Personal safety  
The electrolytes used by EPCOS have not only been optimized with a view to the intended  
application, but also with regard to health and environmental compatibility. They do not contain  
any solvents that are detrimental to health, e.g. dimethyl formamide (DMF) or dimethyl acetamide  
(DMAC).  
Furthermore, part of the high-voltage electrolytes used by EPCOS are self-extinguishing. They  
contain flame-retarding substances which will quickly extinguish any flame that may have been  
ignited.  
As far as possible, EPCOS does not use any dangerous chemicals or compounds to produce  
operating electrolytes. However, in exceptional cases, such materials must be used in order to  
achieve specific physical and electrical properties because no safe substitute materials are  
currently known. However, the amount of dangerous materials used in our products has been  
limited to an absolute minimum. Nevertheless, the following rules should be observed when  
handling aluminum electrolytic capacitors:  
Any escaping electrolyte should not come into contact with eyes or skin.  
If electrolyte does come into contact with the skin, wash the affected parts immediately with  
running water. If the eyes are affected, rinse them for 10 minutes with plenty of water. If  
symptoms persist, seek medical treatment.  
Avoid breathing in electrolyte vapor or mists. Workplaces and other affected areas should be  
well ventilated. Clothing that has been contaminated by electrolyte must be changed and  
rinsed in water.  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 30 of 35  
B41896  
Up to 135 °C  
Product safety  
The table below summarizes the safety instructions that must be observed without fail. A detailed  
description can be found in the relevant sections of chapter "General technical information".  
Topic  
Safety information  
Reference  
chapter "General  
technical information"  
Polarity  
Make sure that polar capacitors are connected  
with the right polarity.  
1
"Basic construction of  
aluminum electrolytic  
capacitors"  
Reverse voltage  
Voltages polarity classes should be prevented by 3.1.6  
connecting a diode.  
"Reverse voltage"  
Upper category  
temperature  
Do not exceed the upper category temperature.  
7.2  
"Maximum permissible  
operating temperature"  
Maintenance  
Make periodic inspections of the capacitors.  
10  
Before the inspection, make sure that the power "Maintenance"  
supply is turned off and carefully discharge the  
electricity of the capacitors.  
Do not apply any mechanical stress to the  
capacitor terminals.  
Mounting  
position of screw-  
terminal capacitors  
Do not mount the capacitor with the terminals  
(safety vent) upside down.  
11.1.  
"Mounting positions of  
capacitors with screw  
terminals"  
Mounting of  
single-ended  
capacitors  
The internal structure of single-ended capacitors 11.4  
might be damaged if excessive force is applied to "Mounting  
the lead wires.  
considerations for  
Avoid any compressive, tensile or flexural stress. single-ended capacitors"  
Do not move the capacitor after soldering to PC  
board.  
Do not pick up the PC board by the soldered  
capacitor.  
Do not insert the capacitor on the PC board with a  
hole space different to the lead space specified.  
Robustness of  
terminals  
The following maximum tightening torques must  
not be exceeded when connecting screw  
11.3  
"Mounting torques"  
terminals:  
M5: 2 Nm  
M6: 2.5 Nm  
Soldering  
Do not exceed the specified time or temperature 11.5  
limits during soldering. "Soldering"  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 31 of 35  
B41896  
Up to 135 °C  
Topic  
Safety information  
Reference  
chapter "General  
technical information"  
Soldering,  
Do not allow halogenated hydrocarbons to come 11.6  
cleaning agents  
into contact with aluminum electrolytic capacitors. "Cleaning agents"  
Passive  
Avoid external energy, such as fire or electricity.  
8.1  
flammability  
"Passive flammability"  
Active  
Avoid overload of the capacitors.  
8.2  
flammability  
"Active flammability"  
Reference  
chapter "Capacitors with  
screw terminals"  
Breakdown strength Do not damage the insulating sleeve, especially  
"Screw terminals ꢀ  
of insulating  
sleeves  
when ring clips are used for mounting.  
accessories"  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 32 of 35  
B41896  
Up to 135 °C  
Symbols and terms  
Symbol English  
German  
C
Capacitance  
Kapazität  
CR  
Rated capacitance  
Nennkapazität  
Serienkapazität  
CS  
Series capacitance  
CS,T  
Cf  
Series capacitance at temperature T  
Capacitance at frequency f  
Case diameter, nominal dimension  
Maximum case diameter  
Self-inductance  
Serienkapazität bei Temperatur T  
Kapazität bei Frequenz f  
d
Gehäusedurchmesser, Nennmaß  
Maximaler Gehäusedurchmesser  
Eigeninduktivität  
dmax  
ESL  
ESR  
ESRf  
Equivalent series resistance  
Equivalent series resistance at  
frequency f  
Ersatzserienwiderstand  
Ersatzserienwiderstand bei Frequenz f  
ESRT  
Equivalent series resistance at  
temperature T  
Ersatzserienwiderstand bei Temperatur T  
f
Frequency  
Frequenz  
I
Current  
Strom  
IAC  
Alternating current (ripple current)  
Root-mean-square value of alternating  
current  
Wechselstrom  
Wechselstrom, Effektivwert  
IAC,rms  
IAC,f  
Ripple current at frequency f  
Maximum permissible ripple current  
Rated ripple current  
Wechselstrom bei Frequenz f  
Maximal zulässiger Wechselstrom  
Nennwechselstrom  
IAC,max  
IAC,R  
IAC,R (B) Rated ripple current for base cooling  
Nennwechselstromstrom für Bodenkühlung  
Reststrom  
Ileak  
Ileak,op  
l
Leakage current  
Operating leakage current  
Case length, nominal dimension  
Maximum case length (without  
terminals and mounting stud)  
Resistance  
Betriebsreststrom  
Gehäuselänge, Nennmaß  
Maximale Gehäuselänge (ohne Anschlüsse  
und Gewindebolzen)  
Widerstand  
lmax  
R
Rins  
Rsymm  
T
Insulation resistance  
Balancing resistance  
Temperature  
Isolationswiderstand  
Symmetrierwiderstand  
Temperatur  
T  
TA  
TC  
TB  
t
Temperature difference  
Ambient temperature  
Case temperature  
Temperaturdifferenz  
Umgebungstemperatur  
Gehäusetemperatur  
Capacitor base temperature  
Time  
Temperatur des Becherbodens  
Zeit  
t  
Period  
Zeitraum  
tb  
Service life (operating hours)  
Brauchbarkeitsdauer (Betriebszeit)  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 33 of 35  
B41896  
Up to 135 °C  
Symbol English  
German  
V
Voltage  
Spannung  
VF  
Vop  
VR  
VS  
XC  
XL  
Z
Forming voltage  
Formierspannung  
Operating voltage  
Rated voltage, DC voltage  
Surge voltage  
Betriebsspannung  
Nennspannung, Gleichspannung  
Spitzenspannung  
Capacitive reactance  
Inductive reactance  
Impedance  
Kapazitiver Blindwiderstand  
Induktiver Blindwiderstand  
Scheinwiderstand  
ZT  
tan δ  
λ
Impedance at temperature T  
Dissipation factor  
Scheinwiderstand bei Temperatur T  
Verlustfaktor  
Failure rate  
Ausfallrate  
ε0  
Absolute permittivity  
Relative permittivity  
Angular velocity; 2 π f  
Elektrische Feldkonstante  
Dielektrizitätszahl  
εr  
ω
Kreisfrequenz; 2 π f  
Note  
All dimensions are given in mm.  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 34 of 35  
Important notes  
The following applies to all products named in this publication:  
1. Some parts of this publication contain statements about the suitability of our products for  
certain areas of application. These statements are based on our knowledge of typical re-  
quirements that are often placed on our products in the areas of application concerned. We  
nevertheless expressly point out that such statements cannot be regarded as binding  
statements about the suitability of our products for a particular customer application.  
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar  
with them than the customers themselves. For these reasons, it is always ultimately incum-  
bent on the customer to check and decide whether an EPCOS product with the properties de-  
scribed in the product specification is suitable for use in a particular customer application.  
2. We also point out that in individual cases, a malfunction of electronic components or  
failure before the end of their usual service life cannot be completely ruled out in the  
current state of the art, even if they are operated as specified. In customer applications  
requiring a very high level of operational safety and especially in customer applications in  
which the malfunction or failure of an electronic component could endanger human life or  
health (e.g. in accident prevention or lifesaving systems), it must therefore be ensured by  
means of suitable design of the customer application or other action taken by the customer  
(e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by  
third parties in the event of malfunction or failure of an electronic component.  
3. The warnings, cautions and product-specific notes must be observed.  
4. In order to satisfy certain technical requirements, some of the products described in this  
publication may contain substances subject to restrictions in certain jurisdictions (e.g.  
because they are classed as hazardous). Useful information on this will be found in our Ma-  
terial Data Sheets on the Internet (www.epcos.com/material). Should you have any more de-  
tailed questions, please contact our sales offices.  
5. We constantly strive to improve our products. Consequently, the products described in this  
publication may change from time to time. The same is true of the corresponding product  
specifications. Please check therefore to what extent product descriptions and specifications  
contained in this publication are still applicable before or when you place an order. We also  
reserve the right to discontinue production and delivery of products. Consequently, we  
cannot guarantee that all products named in this publication will always be available. The  
aforementioned does not apply in the case of individual agreements deviating from the fore-  
going for customer-specific products.  
6. Unless otherwise agreed in individual contracts, all orders are subject to the current ver-  
sion of the "General Terms of Delivery for Products and Services in the Electrical In-  
dustry" published by the German Electrical and Electronics Industry Association  
(ZVEI).  
7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DeltaCap,  
DigiSiMic, DSSP, FormFit, MiniBlue, MiniCell, MKK, MKD, MLSC, MotorCap, PCC,  
PhaseCap, PhaseCube, PhaseMod, PhiCap, SIFERRIT, SIFI, SIKOREL, SilverCap,  
SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trade-  
marks registered or pending in Europe and in other countries. Further information will be  
found on the Internet at www.epcos.com/trademarks.  
Page 35 of 35  

相关型号:

B41896C5687M

Aluminum electrolytic capacitors
EPCOS

B41896C5687M000

Single-ended capacitors
EPCOS

B41896C5687M001

Single-ended capacitors
EPCOS

B41896C5687M003

CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 25V, 680uF, THROUGH HOLE MOUNT, RADIAL LEADED, ROHS COMPLIANT
EPCOS

B41896C5687M009

Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 25V, 20% +Tol, 20% -Tol, 680uF, Through Hole Mount, RADIAL LEADED, ROHS COMPLIANT
EPCOS

B41896C5687M012

CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 25V, 680uF, THROUGH HOLE MOUNT, RADIAL LEADED, ROHS COMPLIANT
EPCOS

B41896C5827M

Aluminum electrolytic capacitors
EPCOS

B41896C5827M000

Single-ended capacitors
EPCOS

B41896C5827M001

Single-ended capacitors
EPCOS

B41896C5827M003

CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 25V, 820uF, THROUGH HOLE MOUNT, RADIAL LEADED, ROHS COMPLIANT
EPCOS

B41896C5827M009

CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 25V, 820uF, THROUGH HOLE MOUNT, RADIAL LEADED, ROHS COMPLIANT
EPCOS

B41896C5827M012

CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 25V, 820uF, THROUGH HOLE MOUNT, RADIAL LEADED, ROHS COMPLIANT
EPCOS