B58611K1500A007 [EPCOS]

Pressure sensors Gauge pressure transducers; 压力传感器压力表压力传感器
B58611K1500A007
型号: B58611K1500A007
厂家: EPCOS    EPCOS
描述:

Pressure sensors Gauge pressure transducers
压力传感器压力表压力传感器

传感器 压力传感器 仪表
文件: 总7页 (文件大小:132K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Pressure sensors  
Gauge pressure transducers  
Series/Type:  
Ordering code:  
AK2 series  
Date:  
Version:  
2009-08-03  
3
Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the  
table and then change the color to "white". This ensures that the table disappears (invisible) for the customer PDF.  
Don't change formatting when entering or pasting text in the table and don't add any cell or line in and to it!  
Identification/Classification 1  
(header 1 + top left bar):  
Pressure sensors  
Identification/Classification 2  
(header 2 + bottom left header bar):  
Gauge pressure transducers  
Ordering code: (top right header bar)  
Series/Type: (top right header bar)  
AK2 series  
Preliminary data (optional):  
(if necessary)  
Department:  
Date:  
AS SEN PD  
2009-08-03  
3
Version:  
EPCOS AG 2009. Reproduction, publication and dissemination of this publication, enclosures hereto and the information  
contained therein without EPCOS' prior express consent is prohibited  
Pressure sensors  
Gauge pressure transducers  
AK2 series  
Description  
The transducers are based on piezoresistive silicon pressure sensors  
from our own clean room.  
The robust stainless steel/plastic casing is accentuated  
through its excellent mechanical decoupling.  
Features  
Piezoresistive MEMS technology  
Measured media:  
Air, non-aggressive gases (gas humidity 0 ... 100% r.h.)  
and non-aggressive fluids.  
Unsuitable for substances which react with glass, silicon, stainless  
steel, silicone glue (pr 10 bar) or epoxy glue (pr > 10 bar).  
Whetstone bridge with mV output, proportional to pressure  
and ratiometric to supply voltage  
RoHS-compatible, halogen-free  
Dual-in-line package for PCB mounting  
Dimensional drawings  
Type KD (4.8 mm tube fitting)  
Type KC (M5 thread connection)  
All dimensions in mm  
AS SEN PD  
2009-08-03  
Please read Cautions and warnings and  
Page 2 of 7  
Important notes at the end of this document.  
Pressure sensors  
Gauge pressure transducers  
AK2 series  
Technical data  
Absolute maximum ratings  
Parameter  
Symbol  
Conditions  
Min.  
Typ.  
Max.  
Unit  
Temperature ranges  
Storage temperature range  
Operating temperature range  
Soldering temperature  
Supply voltage /-current  
Supply voltage  
1)  
2)  
Tst  
–40  
–30  
+125  
+85  
°C  
°C  
°C  
Ta  
Tsolder  
<5 s (no reflow soldering)  
+240  
5)  
VDD  
10  
V
Parameter  
Symbol  
Conditions  
Min.  
Typ.  
Max.  
Unit  
Offset / bridge resistance @ Ta = 25 °C, VDD = 5 V  
Bridge resistance RS  
Chip type C41 (pin1-3)  
Chip type C27 (pin1-3)  
4.0  
2.6  
2.7  
–25  
5.0  
3.3  
3.2  
0
6.0  
4.0  
3.7  
+25  
kΩ  
kΩ  
kΩ  
mV  
Chip type C28 (pin1-3)  
6)  
Offset  
V0  
Data in temperature range @ Ta = –30 ... 85 °C, VDD = 5 V  
9)  
Temperature hysteresis  
% FS  
0.1  
2.4  
6
0.5  
2.7  
8
10)  
Temperature coefficients of the  
2.1  
4
10-3/K  
10-6/K2  
10-3/K  
10-6/K2  
µV/VK  
αRs  
bridge resistance  
βRs  
11)  
Temperature coefficients of the  
–2.4  
3
–2.2  
5
–2.0  
8
αS  
sensitivity  
βS  
12)  
Temperature coefficient of offset  
TCV0  
4
Data dependent on rated pressure @ Ta = 25 °C, VDD = 5 V  
3)  
4)  
Sensitivity S 7)  
Nonlinearity L 8)  
Overpressure pov  
Rated pressure pr  
Chip type  
Min.  
mV/bar  
Typ.  
mV/bar  
Max.  
Typ.  
% FS  
Max.  
% FS  
Min.  
bar  
bar  
mV/bar  
1280  
833  
700  
480  
375  
150  
60  
0.025  
0.060  
0.100  
0.250  
0.400  
1.000  
2.500  
6.000  
10.00  
25.00  
C41  
C41  
C27  
C27  
C27  
C27  
C28  
C28  
C28  
C28  
640  
450  
350  
300  
225  
90  
1000  
700  
500  
400  
300  
120  
48  
0.25  
0.35  
0.5  
0.6  
1
1
1.75  
1.5  
1
0.75  
0.5  
0.5  
1
0.5  
1
3
0.25  
0.25  
0.25  
0.25  
0.25  
0.5  
0.5  
0.5  
0.5  
0.5  
36  
5
15  
20  
25  
9
9
12  
15  
24  
37.5  
3.6  
4.8  
6
AS SEN PD  
2009-08-03  
Please read Cautions and warnings and  
Page 3 of 7  
Important notes at the end of this document.  
Pressure sensors  
Gauge pressure transducers  
AK2 series  
Terminal assignment  
Pin  
1
Symbol  
VDD+  
Terminal assignment  
Supply voltage  
1 VDD+  
2
Vout+  
Output voltage  
3
VDD–  
Supply voltage  
4
Vout–  
Output voltage  
2 Vout+  
4 Vout–  
The polarity of Vout applies to positive pressure.  
Negative pressure or a reversed supply voltage  
results in a reversed polarity of the output voltage Vout  
.
3 VDD–  
Rated pressures and ordering codes  
Type  
Type KD  
Type KC  
Rated pressure pr  
bar  
Product type  
Ordering code  
Other rated pressures upon request.  
AS SEN PD  
2009-08-03  
Please read Cautions and warnings and  
Page 4 of 7  
Important notes at the end of this document.  
Pressure sensors  
Gauge pressure transducers  
AK2 series  
Symbols and terms  
1)  
Storage temperature range Tst  
A storage of the pressure sensor within the temperature range Tst,min up to Tst,max  
and without applied pressure and supply voltage will not affect the performance of the pressure sensor.  
2)  
Operating temperature range Ta  
An operation of the pressure sensor within the temperature range Ta,min up to Ta,max  
will not affect the performance of the pressure sensor.  
3)  
Rated pressure pr  
Within the rated pressure range 0 up to pr the signal output characteristic corresponds to this specification.  
4)  
5)  
Overpressure pOV  
Pressure cycles within the pressure range 0 up to pov will not affect the performance of the pressure sensor.  
Supply voltage VDD  
VDD,max is the maximum permissible supply voltage, which can be applied without damages.  
The output voltage Vout is ratiometric (Vout ~ VDD).  
6)  
7)  
8)  
Offset V0  
The offset V0 is the signal output Vout(p = 0) at zero pressure.  
Sensitivity S  
Within the pressure range 0 up to pr the output voltage is Vout(px) = V0 + S · px  
Nonlinearity L (including pressure hysteresis)  
The nonlinearity is the deviation of the real sensor characteristic Vout = f(p) from the ideal straight line.  
It can be approximated by a polynomial of second order, with the maximum at px = pr / 2 .  
The equation to calculate the nonlinearity is:  
Vout (px ) V0 px  
L =  
Vout (pr ) V0 pr  
9)  
Temperature hysteresis  
The temperature hysteresis is the change of offset, starting from the value at 25 °C after a temperature change  
and return to 25 °C. Determined during temperature cycles in operating temperature range (cycles with 1 K/min).  
(Full Scale): FS = VFS = S · pr  
10)  
11)  
12)  
Temperature coefficients of the bridge resistance αRS, βRS  
Bridge resistance at temperature Tx: RS(Tx) = RS(25 °C) · [ 1 + αRS · (Tx – 25 °C) + βRS · (Tx – 25 °C)2 ]  
Values are valid within the operating temperature range Ta,min up to Ta,max  
Out of the operating temperature range, the deviation may increase.  
Temperature coefficients of the sensitivity αS, βS  
Sensitivity at temperature Tx: S(Tx) = S(25 °C) · [ 1 + αS · (Tx – 25 °C) + βS · (Tx – 25 °C)2 ]  
Values are valid within the operating temperature range Ta,min up to Ta,max  
Out of the operating temperature range, the deviation may increase.  
Temperature coefficient of offset TCV0  
Offset at temperature Tx: V0(Tx) = V0(25 °C) + TCV0 · (Tx – 25 °C) · VDD  
Values are valid within the operating temperature range Ta,min up to Ta,max  
Out of the operating temperature range, the deviation may increase.  
AS SEN PD  
2009-08-03  
Please read Cautions and warnings and  
Page 5 of 7  
Important notes at the end of this document.  
Pressure sensors  
Gauge pressure transducers  
AK2 series  
Cautions and warnings  
Storage (general)  
All pressure sensors should be stored in their original packaging. They should not be placed in harmful environments such  
as corrosive gases nor exposed to heat or direct sunlight, which may cause deformations. Similar effects may result from  
extreme storage temperatures and climatic conditions. Avoid storing the sensor dies in an environment where condensation  
may form or in a location exposed to corrosive gases, which will adversely affect their performance. Plastic materials should  
not be used for wrapping/packing when storing or transporting these dies, as they may become charged. Pressure sensor  
dies should be used soon after opening their seal and packaging.  
Operation (general)  
Media compatibility with the pressure sensors must be ensured to prevent their failure. The use of other media can cause  
damage and malfunction. Never use pressure sensors in atmospheres containing explosive liquids or gases.  
Ensure pressure equalization to the environment, if gauge pressure sensors are used. Avoid operating the pressure sensors  
in an environment where condensation may form or in a location exposed to corrosive gases. These environments adversely  
affect their performance.  
If the operating pressure is not within the rated pressure range, it may change the output characteristics. This may also  
happen with pressure sensor dies if an incorrect mounting method is used. Be sure that the applicable pressure does not  
exceed the overpressure, as it may damage the pressure sensor.  
Do not exceed the maximum rated supply voltage nor the rated storage temperature range, as it may damage the pressure  
sensor.  
Temperature variations in both the ambient conditions and the media (liquid or gas) can affect the accuracy of the output  
signal from the pressure sensors. Be sure to check the operating temperature range and thermal error specification of the  
pressure sensors to determine their suitability for the application.  
Connections must be wired in accordance with the terminal assignment specified in the data sheets. Care should be taken  
as reversed pin connections can damage the pressure transmitters or degrade their performance. Contact between the  
pressure sensor terminals and metals or other materials may cause errors in the output characteristics.  
Design notes (dies)  
This specification describes the mechanical, electrical and physical requirements of a piezoresistive sensor die for  
measuring pressure. The specified parameters are valid for the pressure sensor die with pressure application either to the  
front or back side of the diaphragm as described in the data sheet. Pressure application to the other side may result in  
differing data. Most of the parameters are influenced by assembly conditions. Hence these parameters and the reliability  
have to be specified for each specific application and tested over its temperature range by the customer.  
Handling/Mounting (dies)  
Pressure sensor dies should be handled appropriately and not be touched with bare hands. They should only be picked up  
manually by the sides using tweezers. Their top surface should never be touched with tweezers. Latex gloves should not be  
used for handling them, as this will inhibit the curing of the adhesive used to bond the die to the carrier. When handling, be  
careful to avoid cuts caused by the sharp-edged terminals. The sensor die must not be contaminated during manufacturing  
processes (gluing, soldering, silk-screen process).  
The package of pressure sensor dies should not to be opened until the die is mounted and should be closed after use. The  
sensor die must not be cleaned. The sensor die must not be damaged during the assembly process (especially scratches on  
the diaphragm).  
Soldering (transducers, transmitters)  
The thermal capacity of pressure sensors is normally low, so steps should be taken to minimize the effects of external heat.  
High temperatures may lead to damage or changes in characteristics.  
A non-corrosive type of flux resin should normally be used and complete removal of the flux is recommended.  
Avoid rapid cooling due to dipping in solvent. Note that the output signal may change if pressure is applied to the terminals  
during soldering.  
This listing does not claim to be complete, but merely reflects the experience of EPCOS AG.  
AS SEN PD  
2009-08-03  
Please read Cautions and warnings and  
Page 6 of 7  
Important notes at the end of this document.  
Important notes  
The following applies to all products named in this publication:  
1. Some parts of this publication contain statements about the suitability of our products for  
certain areas of application. These statements are based on our knowledge of typical  
requirements that are often placed on our products in the areas of application concerned. We  
nevertheless expressly point out that such statements cannot be regarded as binding  
statements about the suitability of our products for a particular customer application. As a  
rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them  
than the customers themselves. For these reasons, it is always ultimately incumbent on the  
customer to check and decide whether an EPCOS product with the properties described in the  
product specification is suitable for use in a particular customer application.  
2. We also point out that in individual cases, a malfunction of electronic components or failure  
before the end of their usual service life cannot be completely ruled out in the current state  
of the art, even if they are operated as specified. In customer applications requiring a very high  
level of operational safety and especially in customer applications in which the malfunction or  
failure of an electronic component could endanger human life or health (e.g. in accident  
prevention or life-saving systems), it must therefore be ensured by means of suitable design of the  
customer application or other action taken by the customer (e.g. installation of protective circuitry  
or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or  
failure of an electronic component.  
3. The warnings, cautions and product-specific notes must be observed.  
4. In order to satisfy certain technical requirements, some of the products described in this  
publication may contain substances subject to restrictions in certain jurisdictions (e.g.  
because they are classed as hazardous). Useful information on this will be found in our Material  
Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed  
questions, please contact our sales offices.  
5. We constantly strive to improve our products. Consequently, the products described in this  
publication may change from time to time. The same is true of the corresponding product  
specifications. Please check therefore to what extent product descriptions and specifications  
contained in this publication are still applicable before or when you place an order.  
We also reserve the right to discontinue production and delivery of products. Consequently,  
we cannot guarantee that all products named in this publication will always be available.  
The aforementioned does not apply in the case of individual agreements deviating from the  
foregoing for customer-specific products.  
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of  
the “General Terms of Delivery for Products and Services in the Electrical Industry”  
published by the German Electrical and Electronics Industry Association (ZVEI).  
7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DSSP, MiniBlue,  
MiniCell, MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, SIFERRIT,  
SIFI, SIKOREL, SilverCap, SIMDAD, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse,  
WindCap are trademarks registered or pending in Europe and in other countries. Further  
information will be found on the Internet at www.epcos.com/trademarks.  
Page 7 of 7  

相关型号:

B58611K1500A008

Pressure sensors Gauge pressure transducers
EPCOS

B58611K1500A008

Peizoresistive Sensor, Gage, Through Hole Mount, HALOGEN FREE AND ROHS COMPLIANT, DIP-4
TDK

B58611K1500A009

Pressure sensors Gauge pressure transducers
EPCOS

B58611K1500A010

Pressure sensors Gauge pressure transducers
EPCOS

B58611K1500A010

Peizoresistive Sensor, Gage, Through Hole Mount, HALOGEN FREE AND ROHS COMPLIANT, DIP-4
TDK

B58611K1500A011

Pressure sensors Gauge pressure transducers
EPCOS

B58611K1500A012

Pressure sensors Gauge pressure transducers
EPCOS

B58611K1500A013

Pressure sensors Gauge pressure transducers
EPCOS

B58611K1500A014

Pressure sensors Gauge pressure transducers
EPCOS

B58611K1500A014

Peizoresistive Sensor, Gage, Through Hole Mount, HALOGEN FREE AND ROHS COMPLIANT, DIP-4
TDK

B58611K1500A015

Pressure sensors Gauge pressure transducers
EPCOS

B58611K1500A016

Pressure sensors Gauge pressure transducers
EPCOS