B59955-C160-A70 [EPCOS]
RESISTOR, TEMPERATURE DEPENDENT, PTC, 0.8ohm, THROUGH HOLE MOUNT, RADIAL LEADED, ROHS COMPLIANT;![B59955-C160-A70](http://pdffile.icpdf.com/pdf2/p00301/img/icpdf/B59965-C160-_1819174_icpdf.jpg)
型号: | B59955-C160-A70 |
厂家: | ![]() |
描述: | RESISTOR, TEMPERATURE DEPENDENT, PTC, 0.8ohm, THROUGH HOLE MOUNT, RADIAL LEADED, ROHS COMPLIANT |
文件: | 总10页 (文件大小:138K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
PTC thermistors for
overcurrent protection
Leaded disks, coated, 12 V
Series/Type:
B599*5
Date:
February 2012
© EPCOS AG 2012. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without EPCOS' prior express consent is prohibited.
Overcurrent protection
Leaded disks, coated, 12 V
C945 ... C995
Applications
Dimensional drawing
Overcurrent protection
Short circuit protection
Features
Lead-free terminals
Marking: Type, manufacturer's logo,
reference temperature in °C and date code
YYWW (except B59995C*)
Low resistance
For rated currents of up to 1.5 A
High thermal stability
UL approval to UL 1434 (file number
E69802)
VDE approval for selected types
(license number 104843 E)
Qualification based on AEC-Q200, Rev. D
(except: B59995C*)
Dimensions (mm)
Type
wmax
hmax
d
C945
C955
C965
C975
C985
C995
17.5
13.5
11.0
9.0
6.5
4.0
21.0
17.0
14.5
12.5
10.0
7.5
0.6
0.6
0.6
0.6
0.6
0.5
RoHS-compatible
Options
Leadless disks and leaded disks without
coating available on request
Thermistors with diameter w ≤11.0 mm are
also available on tape (to IEC 60286-2)
Delivery mode
Cardboard strips (standard)
Cardboard tape reeled or in Ammo pack on
request
General technical data
Max. operating voltage
Rated voltage
(TA = 60 °C)
Vmax
VR
20
12
V DC or V AC
V DC or V AC
Switching cycles
Reference temperature
Tolerance of RR
Operating temperature range
Operating temperature range
N
100
160
±25
(typ.)
Tref
∆RR
Top
Top
°C
%
(V = 0)
(V = Vmax
ꢀ40/+125 °C
ꢀ40/+85 °C
)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 2 of 10
Overcurrent protection
Leaded disks, coated, 12 V
C945 ... C995
Electrical specifications and ordering codes
IR
IS
ISmax
Ir
Ir
RR
Rmin
Type
Approvals Ordering code
(V = Vmax) (typ.)
(typ.)
(V = Vmax) (V = VR)
mA
mA
A
mA
mA
Ω
Ω
C945 1500 3050 8.0
C955 950 1900 5.5
C965 700 1450 4.3
C975 550 1100 3.0
C985 300 600 1.0
C995 150 300 0.7
170
120
105
85
65
40
270
190
165
135
100
65
0.45 0.3
0.8 0.5
1.2 0.7
1.8 1.1
4.6 2.7
X
X
X
X
X
X
ꢀ
ꢀ
ꢀ
ꢀ
X
B59945C0160A070
B59955C0160A070
B59965C0160A070
B59975C0160A070
B59985C0160A070
B59995C0160A070
13
7.8
X
Reliability data
Test
Standard
Test conditions
ꢁ∆R25/R25ꢁ
Electrical endurance, IEC 60738-1
cycling
Room temperature, ISmax; Vmax
Number of cycles: 100
< 25%
Electrical endurance, IEC 60738-1
constant
Storage at Vmax /Top,max (Vmax
Test duration: 1000 h
)
< 25%
< 10%
Damp heat
IEC 60738-1
IEC 60738-1
IEC 60738-1
Temperature of air: 40 °C
Relative humidity of air: 93%
Duration: 56 days
Test according to IEC 60068-2-78
Rapid change
of temperature
T1 = Top,min (0 V), T2 = Top,max (0 V)
Number of cycles: 5
Test duration: 30 min
< 10%
Test according to IEC 60068-2-14, test Na
Vibration
Frequency range: 10 to 55 Hz
Displacement amplitude: 0.75 mm
Test duration: 3 × 2 h
< 5%
Test according to IEC 60068-2-6, test Fc
Shock
IEC 60738-1
IEC 60738-1
Acceleration: 390 m/s2
Pulse duration: 6 ms; 6 × 4000 pulses
< 5%
Climatic sequence
Dry heat: T = Top,max (0 V)
Test duration: 16 h
< 10%
Damp heat first cycle
Cold: T = Top,min (0 V)
Test duration: 2 h
Damp heat 5 cycles
Tests performed according to
IEC 60068-2-30
Please read Cautions and warnings and
Important notes at the end of this document.
Page 3 of 10
Overcurrent protection
Leaded disks, coated, 12 V
C945 ... C995
Characteristics (typical)
PTC resistance RPTC versus
PTC temperature TPTC
PTC current IPTC versus PTC voltage VPTC
(measured at 25 °C in still air)
(measured at low signal voltage)
Switching time tS versus switching current IS
(measured at 25 °C in still air)
Rated current IR versus ambient temperature TA
(measured in still air)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 4 of 10
Overcurrent protection
Leaded disks, coated, 12 V
C945 ... C995
Characteristics (typical)
PTC resistance RPTC versus
PTC temperature TPTC
PTC current IPTC versus PTC voltage VPTC
(measured at 25 °C in still air)
(measured at low signal voltage)
Switching time tS versus switching current IS
(measured at 25 °C in still air)
Rated current IR versus ambient temperature TA
(measured in still air)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 5 of 10
Overcurrent protection
Leaded disks, coated, 12 V
C945 ... C995
Cautions and warnings
General
EPCOS thermistors are designed for specific applications and should not be used for purposes
not identified in our specifications, application notes and data books unless otherwise agreed
with EPCOS during the design-in-phase.
Ensure suitability of thermistor through reliability testing during the design-in phase. The ther-
mistors should be evaluated taking into consideration worst-case conditions.
Storage
Store thermistors only in original packaging. Do not open the package before storage.
Storage conditions in original packaging: storage temperature ꢀ25 °C ... +45 °C, relative hu-
midity ≤75% annual mean, maximum 95%, dew precipitation is inadmissible.
Avoid contamination of thermistors surface during storage, handling and processing.
Avoid storage of thermistor in harmful environment with effect on function on long-term opera-
tion (examples given under operation precautions).
Use thermistor within the following period after delivery:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Through-hole devices (housed and leaded PTCs): 24 months
Motor protection sensors, glass-encapsulated sensors and probe assemblies: 24 months
Telecom pair and quattro protectors (TPP, TQP): 24 months
Leadless PTC thermistors for pressure contacting: 12 months
Leadless PTC thermistors for soldering: 6 months
SMDs in EIA sizes 3225 and 4032, and for PTCs with metal tags: 24 months
SMDs in EIA sizes 0402, 0603, 0805 and 1210: 12 months
Handling
PTCs must not be dropped. Chip-offs must not be caused during handling of PTCs.
Components must not be touched with bare hands. Gloves are recommended.
Avoid contamination of thermistor surface during handling.
Soldering (where applicable)
Use rosin-type flux or non-activated flux.
Insufficient preheating may cause ceramic cracks.
Rapid cooling by dipping in solvent is not recommended.
Complete removal of flux is recommended.
Standard PTC heaters are not suitable for soldering.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 6 of 10
Overcurrent protection
Leaded disks, coated, 12 V
C945 ... C995
Mounting
Electrode must not be scratched before/during/after the mounting process.
Contacts and housing used for assembly with thermistor have to be clean before mounting. Es-
pecially grease or oil must be removed.
When PTC thermistors are encapsulated with sealing material, the precautions given in chapter
"Mounting instructions", "Sealing and potting" must be observed.
When the thermistor is mounted, there must not be any foreign body between the electrode of
the thermistor and the clamping contact.
The minimum force of the clamping contacts pressing against the PTC must be 10 N.
During operation, the thermistor’s surface temperature can be very high. Ensure that adjacent
components are placed at a sufficient distance from the thermistor to allow for proper cooling at
the thermistors.
Ensure that adjacent materials are designed for operation at temperatures comparable to the
surface temperature of thermistor. Be sure that surrounding parts and materials can withstand
this temperature.
Avoid contamination of thermistor surface during processing.
Operation
Use thermistors only within the specified temperature operating range.
Use thermistors only within the specified voltage and current ranges.
Environmental conditions must not harm the thermistors. Use thermistors only in normal at-
mospheric conditions. Avoid use in deoxidizing gases (chlorine gas, hydrogen sulfide gas, am-
monia gas, sulfuric acid gas etc), corrosive agents, humid or salty conditions. Contact with any
liquids and solvents should be prevented.
Be sure to provide an appropriate fail-safe function to prevent secondary product damage
caused by abnormal function (e.g. use VDR for limitation of overvoltage condition).
Please read Cautions and warnings and
Important notes at the end of this document.
Page 7 of 10
Overcurrent protection
Leaded disks, coated, 12 V
C945 ... C995
Symbols and terms
A
Area
C
Capacitance
Cth
f
Heat capacity
Frequency
I
Current
Imax
IR
Maximum current
Rated current
Ires
IPTC
Ir
Residual current
PTC current
Residual currrent
Ir,oil
Ir,air
IRMS
IS
Residual currrent in oil (for level sensors)
Residual currrent in air (for level sensors)
Root-mean-square value of current
Switching current
ISmax
LCT
N
Maximum switching current
Lower category temperature
Number (integer)
Nc
Operating cycles at Vmax, charging of capacitor
Switching cycles at Vmax, failure mode
Power
Nf
P
P25
Pel
Pdiss
RG
Rmin
RR
∆RR
RP
RPTC
Rref
RS
R25
R25,match
∆R25
T
Maximum power at 25 °C
Electrical power
Dissipation power
Generator internal resistance
Minimum resistance
Rated resistance
Tolerance of RR
Parallel resistance
PTC resistance
Reference resistance
Series resistance
Resistance at 25 °C
Resistance matching per reel/ packing unit at 25 °C
Tolerance of R25
Temperature
t
Time
TA
Ambient temperature
Thermal threshold time
ta
Please read Cautions and warnings and
Important notes at the end of this document.
Page 8 of 10
Overcurrent protection
Leaded disks, coated, 12 V
C945 ... C995
TC
Ferroelectric Curie temperature
Settling time (for level sensors)
Rated temperature
tE
TR
Tsense
Top
Sensing temperature
Operating temperature
TPTC
tR
PTC temperature
Response time
Tref
Reference temperature
TRmin
tS
Temperature at minimum resistance
Switching time
Tsurf
UCT
V or Vel
Vc(max)
VF,max
VRMS
VBD
Surface temperature
Upper category temperature
Voltage (with subscript only for distinction from volume)
Maximum DC charge voltage of the surge generator
Maximum voltage applied at fault conditions in protection mode
Root-mean-square value of voltage
Breakdown voltage
Vins
Insulation test voltage
Vlink,max
Vmax
Vmax,dyn
Vmeas
Vmeas,max
VR
Maximum link voltage
Maximum operating voltage
Maximum dynamic (short-time) operating voltage
Measuring voltage
Maximum measuring voltage
Rated voltage
VPTC
α
Voltage drop across a PTC thermistor
Temperature coefficient
∆
Tolerance, change
δth
Dissipation factor
τth
Thermal cooling time constant
Failure rate
λ
Lead spacing (in mm)
Abbreviations / Notes
Surface-mount devices
* To be replaced by a number in ordering codes, type designations etc.
+ To be replaced by a letter
All dimensions are given in mm.
The commas used in numerical values denote decimal points.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 9 of 10
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical re-
quirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application.
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar
with them than the customers themselves. For these reasons, it is always ultimately incum-
bent on the customer to check and decide whether an EPCOS product with the properties de-
scribed in the product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of electronic components or
failure before the end of their usual service life cannot be completely ruled out in the
current state of the art, even if they are operated as specified. In customer applications
requiring a very high level of operational safety and especially in customer applications in
which the malfunction or failure of an electronic component could endanger human life or
health (e.g. in accident prevention or lifesaving systems), it must therefore be ensured by
means of suitable design of the customer application or other action taken by the customer
(e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by
third parties in the event of malfunction or failure of an electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as hazardous). Useful information on this will be found in our Ma-
terial Data Sheets on the Internet (www.epcos.com/material). Should you have any more de-
tailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order. We also
reserve the right to discontinue production and delivery of products. Consequently, we
cannot guarantee that all products named in this publication will always be available. The
aforementioned does not apply in the case of individual agreements deviating from the fore-
going for customer-specific products.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current ver-
sion of the "General Terms of Delivery for Products and Services in the Electrical In-
dustry" published by the German Electrical and Electronics Industry Association
(ZVEI).
7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DeltaCap,
DigiSiMic, DSSP, FormFit, MiniBlue, MiniCell, MKD, MKK, MLSC, MotorCap, PCC,
PhaseCap, PhaseCube, PhaseMod, PhiCap, SIFERRIT, SIFI, SIKOREL, SilverCap,
SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trade-
marks registered or pending in Europe and in other countries. Further information will be
found on the Internet at www.epcos.com/trademarks.
Page 10 of 10
相关型号:
![](http://pdffile.icpdf.com/pdf2/p00298/img/page/B59940-C80-A_1805101_files/B59940-C80-A_1805101_1.jpg)
![](http://pdffile.icpdf.com/pdf2/p00298/img/page/B59940-C80-A_1805101_files/B59940-C80-A_1805101_2.jpg)
B59960-C120-A70
RESISTOR, TEMPERATURE DEPENDENT, PTC, 5.6ohm, THROUGH HOLE MOUNT, RADIAL LEADED, ROHS COMPLIANT
EPCOS
![](http://pdffile.icpdf.com/pdf2/p00298/img/page/B59940-C80-A_1805101_files/B59940-C80-A_1805101_1.jpg)
![](http://pdffile.icpdf.com/pdf2/p00298/img/page/B59940-C80-A_1805101_files/B59940-C80-A_1805101_2.jpg)
B59960-C130-A70
RESISTOR, TEMPERATURE DEPENDENT, PTC, 8ohm, THROUGH HOLE MOUNT, RADIAL LEADED, ROHS COMPLIANT
EPCOS
![](http://pdffile.icpdf.com/pdf2/p00298/img/page/B59940-C80-A_1805101_files/B59940-C80-A_1805101_1.jpg)
![](http://pdffile.icpdf.com/pdf2/p00298/img/page/B59940-C80-A_1805101_files/B59940-C80-A_1805101_2.jpg)
B59960-C80-A70
RESISTOR, TEMPERATURE DEPENDENT, PTC, 5.6ohm, THROUGH HOLE MOUNT, RADIAL LEADED, ROHS COMPLIANT
EPCOS
©2020 ICPDF网 联系我们和版权申明