B84111-A-A30 [EPCOS]
SIFI-A for normal insertion loss Rated voltage 250 V~, 50/60 Hz Rated current 1 A to 20 A; SIFI -A正常插入损耗额定电压250 V〜 , 50/60 Hz额定电流1 A到20 A型号: | B84111-A-A30 |
厂家: | EPCOS |
描述: | SIFI-A for normal insertion loss Rated voltage 250 V~, 50/60 Hz Rated current 1 A to 20 A |
文件: | 总7页 (文件大小:136K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
2-Line Filters
SIFI-A Series
B84111
SIFI-A for normal insertion loss
Rated voltage 250 V~, 50/60 Hz
Rated current 1 A to 20 A
Construction
ꢀ Two-line filter
ꢀ Metal case
ꢀ Polyurethane potting (UL 94 V-0)
Features
ꢀ Compact design
ꢀ Low leakage current
ꢀ All relevant approvals
ꢀ Cost-optimized construction
ꢀ Also for assembly on top-hat rails
Applications
ꢀ Switch-mode power supplies in
– industrial electronics
– telecommunications
– data systems
– medical engineering
Case styles and terminal styles
Case style A
Tab connectors on face ends, lateral mounting tabs.
Particularly suitable for mounting on a shielding wall.
Case style B
Case style K
Tab connectors on face ends, mounting tabs on face ends.
IEC connector as per IEC 60320 C 14 on line side,
tab connectors on load side, mounting holes with metric thread.
Case style L
Litz wires on face ends
Marking
Marking on component:
Manufacturer’s logo, ordering code,
rated voltage, rated current,
date code
Minimum marking on packaging:
Manufacturer’s logo, ordering code
141 03/01
2-Line Filters
SIFI-A Series
B84111
Circuit diagram
LINE
N
LOAD
N’
L
L’
SSB0525-W
Technical data
Rated voltage VR
Rated current IR
Test voltage VP
250 V~, 50/60 Hz
Referred to 40 °C ambient temperature
1414 V–, 2 s (line/line)
2700 V–, 2 s (lines/case)
Leakage current lleak
< 0,5 mA at 230 V~, 50 Hz
Discharge resistors
The discharge resistors are rated such that one second
after having disconnected the device from the power
line, the voltage at the line connector should have
dropped to 34 V.
Climatic category
Approvals
In accordance with EN 60068-1
25/085/21 (– 25 °C/+ 85 °C/21 days damp heat test)
EN 133221
142 03/01
2-Line Filters
SIFI-A Series
B84111
Characteristics and ordering codes
IR
CR
LR
Case Appr. Ordering code
Mounting plate
A
style
weight
g
for top-hat rail
(ordering code)
1
2 × 0,1 µF (X2)
+
2 × 4700 pF (Y2)
2 × 1,5 mH
2 × 1,5 mH
2 × 1,5 mH
2 × 1,8 mH
A
K
80
140
B84111-A-A10
B84111-A-K10
—
—
2
3
6
2 × 0,1 µF (X2)
+
2 × 4700 pF (Y2)
A
80
B84111-A-A20
—
2 × 0,1 µF (X2)
+
2 × 4700 pF (Y2)
A
K
L
80
140
80
B84111-A-A30
B84111-A-K30
B84111-A-L30
—
—
—
2 × 0,1 µF (X2)
+
2 × 4700 pF (Y2)
A
B
K
L
110
110
140
110
B84111-A-A60
B84111-A-B60
B84111-A-K60
B84111-A-L60
—
C62122-A132-B91
—
—
10
20
2 × 0,1 µF (X2)
+
2 × 4700 pF (Y2)
2 × 820 µH
2 × 470 µH
A
B
L
120
120
120
B84111-A-A110
B84111-A-B110
B84111-A-L110
—
C62122-A132-B91
—
2 × 0,1 µF (X2)
+
A
B
210
210
B84111-A-A120
B84111-A-B120
—
C62122-A132-B91
2 × 4700 pF (Y2)
143 03/01
2-Line Filters
SIFI-A Series
B84111
Case styles and dimensions
Case
style
Ordering Dimensions in mm
code
b1
b2
b3
b4
l1
l2
l3
l4
h1
h2
Litz
Style
B84111-
mm2 1015
A
K
-A-A10
-A-K10
45
51
26,5 60,4 70
50
63,5
—
—
—
—
76,5 22,3 14
32
—
—
—
—
—
—
—
—
—
A
-A-A20
45
26,5 60,4 70
50
—
—
76,5 22,3 14
—
—
A
K
L
-A-A30
-A-K30
-A-L30
45
51
45
26,5 60,4 70
50
63,5
50
—
—
—
—
—
—
76,5 22,3 14
—
—
—
—
—
—
—
60,4 70
—
—
—
32
28,6
—
—
0,82 AWG18
A
B
K
L
-A-A60
-A-B60
-A-K60
-A-L60
45
45
51
45
26,5 60,4 70
50
50
63,5
50
—
60,4 70
—
—
—
76,5 28,6 20
76,5 28,6 20
—
—
—
—
—
—
26,5
—
—
—
—
—
—
—
—
—
32
28,6
—
—
—
60,4 70
0,82 AWG18
A
B
L
-A-A110 45
-A-B110 45
-A-L110 45
26,5 60,4 70
50
50
50
—
60,4 70
—
—
76,5 28,6 20
76,5 28,6 20
—
—
—
—
26,5
—
—
—
60,4 70
—
—
28,6
—
1,35 AWG16
A
B
-A-A120 63,5 31,5 74,7 84,5 50,8
—
—
77
38,1 28
—
—
-A-B120
see dimensional drawing
Case style A
Case style A
B84111-A-A10
B84111-A-A20
B84111-A-A30
B84111-A-A60
B84111-A-A110
B84111-A-A120
Tab connector
Tab connector
144 03/01
2-Line Filters
SIFI-A Series
B84111
Case style B
Case style B
B84111-A-B60
B84111-A-B110
B84111-A-B120
Tab connector
Tab connector
A6,3x0,8 DIN 46244
Case style K
Case style L
Tab connector
BN
BU
Mounting detail
GN/YE
BN
BU
145 03/01
2-Line Filters
SIFI-A Series
B84111
Insertion loss (typical values at Z = 50 Ω)
unsymmetrical, adjacent branches terminated
common mode, all branches in parallel (asymmetrical)
differential mode (symmetrical)
B84111-A- 10 ... -A- 30
B84111-A- 60
*
*
*
SSB0240-L
SSB0239-I
100
100
dB
80
dB
αe
αe
80
60
40
20
60
40
20
0
0
104
105
106
107
Hz 108
104
105
106
107
Hz 108
f
f
B84111-A- 110
*
B84111-A- 120
*
SSB0242-3
SSB0241-U
100
100
dB
dB
αe
αe
80
60
40
20
80
60
40
20
0
0
104
105
106
107
Hz 108
f
104
105
106
107
Hz 108
f
146 03/01
Herausgegeben von EPCOS AG
Marketing Kommunikation, Postfach 80 17 09, 81617 München, DEUTSCHLAND
EPCOS AG 2000. Alle Rechte vorbehalten. Vervielfältigung, Veröffentlichung, Verbreitung und
Verwertung dieser Broschüre und ihres Inhalts ohne ausdrückliche Genehmigung der EPCOS AG
nicht gestattet.
Mit den Angaben in dieser Broschüre werden die Bauelemente spezifiziert, keine Eigenschaften
zugesichert. Bestellungen unterliegen den vom ZVEI empfohlenen Allgemeinen Lieferbedingungen
für Erzeugnisse und Leistungen der Elektroindustrie, soweit nichts anderes vereinbart wird.
Diese Broschüre ersetzt die vorige Ausgabe.
Fragen über Technik, Preise und Liefermöglichkeiten richten Sie bitte an den Ihnen nächstgele-
genen Vertrieb der EPCOS AG oder an unsere Vertriebsgesellschaften im Ausland.
Bauelemente können aufgrund technischer Erfordernisse Gefahrstoffe enthalten. Auskünfte
darüber bitten wir unter Angabe des betreffenden Typs ebenfalls über die zuständige Vertriebsge-
sellschaft einzuholen.
Published by EPCOS AG
Marketing Communications, P.O. Box 80 17 09, 81617 Munich, GERMANY
EPCOS AG 2000. All Rights Reserved. Reproduction, publication and dissemination of this bro-
chure and the information contained therein without EPCOS’ prior express consent is prohibited.
The information contained in this brochure describes the type of component and shall not be con-
sidered as guaranteed characteristics. Purchase orders are subject to the General Conditions for
the Supply of Products and Services of the Electrical and Electronics Industry recommended by the
ZVEI (German Electrical and Electronic Manufacturers’ Association), unless otherwise agreed.
This brochure replaces the previous edition.
For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or
the international Representatives.
Due to technical requirements components may contain dangerous substances. For information on
the type in question please also contact one of our Sales Offices.
1
相关型号:
B84111-A-A60
SIFI-A for normal insertion loss Rated voltage 250 V~, 50/60 Hz Rated current 1 A to 20 A
EPCOS
B84111-A-B110
SIFI-A for normal insertion loss Rated voltage 250 V~, 50/60 Hz Rated current 1 A to 20 A
EPCOS
B84111-A-B120
SIFI-A for normal insertion loss Rated voltage 250 V~, 50/60 Hz Rated current 1 A to 20 A
EPCOS
B84111-A-B60
SIFI-A for normal insertion loss Rated voltage 250 V~, 50/60 Hz Rated current 1 A to 20 A
EPCOS
B84111-A-K10
SIFI-A for normal insertion loss Rated voltage 250 V~, 50/60 Hz Rated current 1 A to 20 A
EPCOS
B84111-A-K30
SIFI-A for normal insertion loss Rated voltage 250 V~, 50/60 Hz Rated current 1 A to 20 A
EPCOS
B84111-A-K60
SIFI-A for normal insertion loss Rated voltage 250 V~, 50/60 Hz Rated current 1 A to 20 A
EPCOS
B84111-A-L110
SIFI-A for normal insertion loss Rated voltage 250 V~, 50/60 Hz Rated current 1 A to 20 A
EPCOS
B84111-A-L30
SIFI-A for normal insertion loss Rated voltage 250 V~, 50/60 Hz Rated current 1 A to 20 A
EPCOS
B84111-A-L60
SIFI-A for normal insertion loss Rated voltage 250 V~, 50/60 Hz Rated current 1 A to 20 A
EPCOS
©2020 ICPDF网 联系我们和版权申明