B84113H0000B110 [EPCOS]

2−line filters SIFI−H for very high insertion loss; 2线滤波器SIFI -H非常高的插入损耗
B84113H0000B110
型号: B84113H0000B110
厂家: EPCOS    EPCOS
描述:

2−line filters SIFI−H for very high insertion loss
2线滤波器SIFI -H非常高的插入损耗

文件: 总14页 (文件大小:285K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
2−line filters  
SIFI−H for very high insertion loss  
250 V DC/AC, 50/60 Hz, 3 ... 36 A  
Series/Type:  
Date:  
B84113H0000*  
2008−08−11  
05  
Version:  
EPCOS AG 2008. Reproduction, publication and dissemination of this publication, enclosures  
hereto and the information contained therein without EPCOS’ prior express consent is prohibited.  
2−line filters  
B84113H0000*  
SIFI−H for very high insertion loss  
Construction  
S 2−line filter  
S Metal case  
S Polyurethane potting (UL 94 V−0)  
Features  
S Easy to install  
S Compact design  
S Cost optimized construction  
S Medical version with low leakage current  
S ENEC10, UL and cUL approval  
c
us  
Applications  
S Switched−mode power supplies for  
− industrial electronics  
− telecom systems  
− data systems  
S DC applications  
S Medical engineering Type M  
Terminals  
S Filters up to 16A tab connectors 6.3 x 0.8 mm  
S Threaded studs M5 for filters from 20A to 36A  
Marking  
S Marking on component:  
manufacturer’s logo, ordering code, rated voltage, rated current,  
rated temperature, climatic category, date code  
S Minimum marking on packaging: maufacturer’s logo, ordering code,  
date code, quantity  
Please read and Cautions and warnings and  
Important notes at the end of this document.  
P
a
g
e
2
o
f
1
4
B
8
4
1
4
3
-
H
0
0
0
0
-
*
-
0
5
-
7
6
5
9
2−line filters  
B84113H0000*  
SIFI−H for very high insertion loss  
Typical circuit diagram of B84113H0000B* and B84113H0000G*  
LINE  
LOAD  
L’  
L
PE  
N
N’  
Technical data and measuring conditions of B84113H0000B* and B84113H0000G*  
Rated voltage  
UR  
250  
V DC/AC  
Hz  
Rated frequency  
fR  
50/60  
1770  
2700  
Test voltage line to line for 2 s  
Test voltage line to case for 2 s  
Leakage current  
Utest  
Utest  
Ileak  
V DC  
V DC  
At 230 V AC,  
50 Hz  
Rated temperature  
TR  
40  
°C  
Climatic category (IEC 60068−1)  
25/100/21  
Please read and Cautions and warnings and  
Important notes at the end of this document.  
P
a
g
e
3
o
f
1
4
B
8
4
1
4
3
-
H
0
0
0
0
-
*
-
0
5
-
7
6
5
9
2−line filters  
B84113H0000*  
SIFI−H for very high insertion loss  
Typical circuit diagram of B84113H0000M* (for medical applications)  
LINE  
LOAD  
L’  
L
PE  
N
N’  
Technical data and measuring conditions of B84113H0000M*  
Rated voltage  
UR  
250  
V DC/AC  
Hz  
Rated frequency  
fR  
50/60  
1770  
2500  
Test voltage line to line for 2 s  
Test voltage line to case for 2 s  
Leakage current  
Utest  
Utest  
Ileak  
V DC  
V AC  
At 230 V AC,  
50 Hz  
Rated temperature  
TR  
40  
°C  
Climatic category (IEC 60068−1)  
25/100/21  
Please read and Cautions and warnings and  
Important notes at the end of this document.  
Pa g e 4 o f 1 4  
B
8
4
1
4
3
-
H
0
0
0
0
-
*
-
0
5
-
7
6
5
9
2−line filters  
B84113H0000*  
SIFI−H for very high insertion loss  
Characteristics and ordering codes of B84113H0000B* and B84113H0000G*  
IR  
CR  
LR  
Ileak  
Case Approx. Ordering code  
style weight  
Approvals  
A
mH  
mA  
g
3 2 x 1,0 µF (X2)  
4 x 5,9 < 0,5  
4 x 3,6 < 0,5  
4 x 3,9 < 0,5  
4 x 1,3 < 0,5  
4 x 1,2 < 3,5  
4 x 0,8 < 3,5  
4 x 0,5 < 3,5  
1
1
2
2
3
3
3
250  
260  
420  
440  
860  
870  
870  
B84113H0000B030  
B84113H0000B060  
B84113H0000B110  
B84113H0000B116  
B84113H0000G120  
B84113H0000G125  
B84113H0000G136  
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
2 x 4700 pF (Y2)  
6 2 x 1,0 µF (X2)  
2 x 4700 pF (Y2)  
10 2 x 1,5 µF (X2)  
2 x 4700 pF (Y2)  
16 2 x 1,5 µF (X2)  
2 x 4700 pF (Y2)  
20 2 x 2,2 µF (X2)  
2 x 22 nF (Y2)  
25 2 x 2,2 µF (X2)  
2 x 22 nF (Y2)  
36 2 x 3,3 µF (X2)  
2 x 22 nF (Y2)  
Characteristics and ordering codes of B84113H0000M*  
IR  
CR  
LR  
Ileak  
Case Approx. Ordering code  
style weight  
Approvals  
A
mH  
µA  
g
3 2 x 1,0 µF (X2) 4 x 5,9 < 2  
6 2 x 1,0 µF (X2) 4 x 3,6 < 2  
1
1
2
2
3
3
3
250  
260  
420  
440  
860  
870  
870  
B84113H0000M030  
B84113H0000M060  
B84113H0000M110  
B84113H0000M116  
B84113H0000M120  
B84113H0000M125  
B84113H0000M136  
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
10 2 x 1,5 µF (X2) 4 x 3,9 < 2  
16 2 x 1,5 µF (X2) 4 x 1,3 < 2  
20 2 x 2,2 µF (X2) 4 x 1,2 < 2  
25 2 x 2,2 µF (X2) 4 x 0,8 < 2  
36 2 x 3,3 µF (X2) 4 x 0,5 < 2  
X = approval granted  
Please read and Cautions and warnings and  
Important notes at the end of this document.  
P
a
g
e
5
o
f
1
4
B
8
4
1
4
3
-
H
0
0
0
0
-
*
-
0
5
-
7
6
5
9
2−line filters  
B84113H0000*  
SIFI−H for very high insertion loss  
Dimensional drawing (case style 1)  
B84113H0000B030...B84113H0000B060  
B84113H0000M030...B84113H0000M060  
Please read and Cautions and warnings and  
Important notes at the end of this document.  
Pa g e 6 o f 1 4  
B8 4 1 4 3- H 00 0 0 -* - 0 5 -7 6 5 9  
2−line filters  
B84113H0000*  
SIFI−H for very high insertion loss  
Dimensional drawing (case style 2)  
B84113H0000B110...B84113H0000B116  
B84113H0000M110...B84113H0000M116  
Please read and Cautions and warnings and  
Important notes at the end of this document.  
Pa g e 7 o f 1 4  
B
8
4
1
4
3
-
H
0
0
0
0
-
*
-
0
5
-
7
6
5
9
2−line filters  
B84113H0000*  
SIFI−H for very high insertion loss  
Dimensional drawing (case style 3)  
B84113H0000G120...B84113H0000G136  
B84113H0000M120...B84113H0000M136  
Please read and Cautions and warnings and  
Important notes at the end of this document.  
Pa g e 8 o f 1 4  
B8 4 1 4 3- H 00 0 0 -* - 0 5 -7 6 5 9  
2−line filters  
B84113H0000*  
SIFI−H for very high insertion loss  
Insertion loss (typical values at Z = 50 W)  
unsymmetrical, adjacent branches terminated  
common mode, all branches in parallel (asymmetrical)  
differential mode (symmetrical)  
B84113H0000B030  
B84113H0000B060  
100  
dB  
100  
dB  
a
a
80  
60  
40  
20  
0
80  
60  
40  
20  
0
6
7
6
7
4
5
8
4
5
8
10  
10  
Hz  
10  
10  
Hz  
10  
10  
10  
10  
10  
10  
f
f
B84113H0000B110  
B84113H0000B116  
100  
dB  
100  
dB  
a
a
80  
60  
40  
20  
0
80  
60  
40  
20  
0
6
7
6
7
4
5
8
4
5
8
10  
10  
Hz  
10  
10  
Hz  
10  
10  
10  
10  
10  
10  
f
f
Please read and Cautions and warnings and  
Important notes at the end of this document.  
P
a
g
e
9
o
f
1
4
B
8
4
1
4
3
-
H
0
0
0
0
-
*
-
0
5
-
7
6
5
9
2−line filters  
B84113H0000*  
SIFI−H for very high insertion loss  
Insertion loss (typical values at Z = 50 W)  
unsymmetrical, adjacent branches terminated  
common mode, all branches in parallel (asymmetrical)  
differential mode (symmetrical)  
B84113H0000B120  
B84113H0000B125  
100  
dB  
100  
dB  
a
a
80  
60  
40  
20  
0
80  
60  
40  
20  
0
6
7
6
7
4
5
8
4
5
8
10  
10  
Hz  
10  
10  
Hz  
10  
10  
10  
10  
10  
10  
f
f
B84113H0000B136  
100  
dB  
a
80  
60  
40  
20  
0
6
7
4
5
8
10  
10  
Hz  
10  
10  
10  
f
Please read and Cautions and warnings and  
Important notes at the end of this document.  
P
a
g
e
1
0
o
f
1
4
B
8
4
1
4
3
-
H
0
0
0
0
-
*
-
0
5
-
7
6
5
9
2−line filters  
B84113H0000*  
SIFI−H for very high insertion loss  
Insertion loss (typical values at Z = 50 W)  
unsymmetrical, adjacent branches terminated  
common mode, all branches in parallel (asymmetrical)  
differential mode (symmetrical)  
B84113H0000M030  
B84113H0000M060  
100  
dB  
100  
dB  
a
a
80  
60  
40  
20  
0
80  
60  
40  
20  
0
6
7
6
7
4
5
8
4
5
8
10  
10  
Hz  
10  
10  
Hz  
10  
10  
10  
10  
10  
10  
f
f
B84113H0000M110  
B84113H0000M116  
100  
dB  
100  
dB  
a
a
80  
60  
40  
20  
0
80  
60  
40  
20  
0
6
7
6
7
4
5
8
4
5
8
10  
10  
Hz  
10  
10  
Hz  
10  
10  
10  
10  
10  
10  
f
f
Please read and Cautions and warnings and  
Important notes at the end of this document.  
P
a
g
e
1
1
o
f
1
4
B8 4 1 4 3- H 00 0 0 -* - 0 5 -7 6 5 9  
2−line filters  
B84113H0000*  
SIFI−H for very high insertion loss  
Insertion loss (typical values at Z = 50 W)  
unsymmetrical, adjacent branches terminated  
common mode, all branches in parallel (asymmetrical)  
differential mode (symmetrical)  
B84113H0000M120  
B84113H0000M125  
100  
dB  
100  
dB  
a
a
80  
60  
40  
20  
0
80  
60  
40  
20  
0
6
7
6
7
4
5
8
4
5
8
10  
10  
Hz  
10  
10  
Hz  
10  
10  
10  
10  
10  
10  
f
f
B84113H0000M136  
100  
dB  
a
80  
60  
40  
20  
0
6
7
4
5
8
10  
10  
Hz  
10  
10  
10  
f
Please read and Cautions and warnings and  
Important notes at the end of this document.  
Pa g e 1 2 o f 1 4  
B
8
4
1
4
3
-
H
0
0
0
0
-
*
-
0
5
-
7
6
5
9
2−line filters  
B84113H0000*  
SIFI−H for very high insertion loss  
Caution and warnings  
S Please note the advices in our data book “EMC Filters” (latest edition); attention should  
be paid to the chapter “General safety notes”.  
S It shall be ensured that only qualified persons (electricity specialists) are engaged on work  
such as planning, assembly, installation, operation, repair and maintenance. They must  
be provided with the corresponding documentation.  
S Danger of electric shock. EMC filters contain components that store an electric charge.  
Dangerous voltages can continue to exist at the filter terminals for longer than five min-  
utes even after the power has been switched off.  
S The protective earth connections shall be the first to be made when the EMC filter is  
installed and the last to be disconnected. Depending on the magnitude of the leakage cur-  
rents, the particular specifications for making the protective−earth connection must be ob-  
served.  
S Impermissible overloading of the EMC filter, such as with circuits able to cause reso-  
nances, impermissible voltages at higher frequencies etc. can lead to bodily injury and  
death as well as cause substantial material damages (e.g. destruction of the filter hous-  
ing).  
S EMC filters must be protected in the application against impermissible exceeding of the  
rated currents by overcurrent protective.  
S In case of leakage currents > 3.5 mA you shall mount the PE conductor stationary with  
the required cross section before beginning of operation and save it against disconnect-  
ing. For leakage currents IL 4) < 10 mA the PE conductor must have a KU value 3) of 4.5;  
for leakage currents IL q 10 mA the PE conductor must have a KU value of 6.  
3) The KU value (symbol KU) is a classification parameter of safety−referred failure types designed to ensure protection against hazardous  
body currents and excessive heating.  
A value of KU = 4.5 with respect to interruptions is attained:  
2
− with a permanently connected protective earth circuit w 1.5 mm  
2
− with a protective earth circuit w 2.5 mm connected via shroud connectors (IEC 60309−2).  
2
KU = 6 with respect to interruptions is achieved for fixed−connection lines w 10 mm where the type of connection and line layout corre-  
spond to the requirements for PEN conductors as specified in relevant standards.  
4) I = leakage current let−go  
L
Please read and Cautions and warnings and  
Important notes at the end of this document.  
Pa g e 1 3 o f 1 4  
B
8
4
1
4
3
-
H
0
0
0
0
-
*
-
0
5
-
7
6
5
9
2−line filters  
B84113H0000*  
SIFI−H for very high insertion loss  
Important notes  
The following applies to all products named in this publication:  
1. Some parts of this publication contain statements about the suitability of our products  
for certain areas of application. These statements are based on our knowledge of typical  
requirements that are often placed on our products in the areas of application concerned.  
We nevertheless expressly point out that such statement cannot be regarded as binding  
statements about the suitability of our products for a particular customer application.  
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar  
with them than the customers themselves. For these reasons, it is always ultimately incum-  
bent on the customer to check and decide whether an EPCOS product with the properties  
described in the product specification is suitable for use in a particular customer application.  
2. We also point out that in individual cases, a malfunction of electronic components or  
failure before end of their usual service life time cannot be completely ruled out in the  
current state of the art, even if they are operated as specified. In customer applications  
requiring a very high level of operational safety and especially in customer applications in  
which the malfunction or failure of a passive electronic component could endanger human  
life or health (e.g. in accident prevention or life−saving systems), it must therefore be en-  
sured by means of suitable design of the customer application or other action taken by the  
customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is  
sustained by third parties in the event of malfunction or failure of a passive electronic compo-  
nent.  
3. The warnings, cautions and product−specific notes must be observed.  
4. In order to satisfy certain technical requirements, some of the products described in this  
publication may contain substances subject to restrictions in certain jurisdictions  
(e.g. because they are classed as hazardous). Useful information on this will be found in  
our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any  
more detailed questions, please contact our sales offices.  
5. We constantly strive to improve our products. Consequently, the products described in  
this publication may change from time to time. The same is true of the corresponding  
product specifications. Please check therefore to what extent product descriptions and spec-  
ifications contained in this publication are still applicable before or when you place an order.  
We also reserve the right to discontinue production and delivery of products. Conse-  
quently, we cannot guarantee that all products named in this publication will always be avail-  
able. The aforementioned does not apply in the case of individual agreements deviating from  
the foregoing for customer−specific products.  
6. Unless otherwise agreed in individual contracts, all orders subject to the current version  
of the “General Terms of Delivery for Products and Services in the Electrical Industry”  
published by the the German Electrical and Electronics Industry Association (ZVEI).  
7. The trade names EPCOS, BAOKE, Alu−X, CeraDiode, CSSP, CTVS, DSSP, MiniBlue, MKK,  
MLSC, MotorCAP, PCC, PhaseCap, PhaseMod, SIFERRIT, SIFI, SIKOREL, SilverCap,  
SIMDAD, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are  
trademarks registered or pending in Europe and in other countries. Further information  
will be found on the Internet at www.epcos.com/trademarks.  
1
Please read and Cautions and warnings and  
Important notes at the end of this document.  
Pa g e 1 4 o f 1 4  
B8 4 1 4 3- H 00 0 0 -* - 0 5 -7 6 5 9  

相关型号:

B84113H0000B116

2−line filters SIFI−H for very high insertion loss
EPCOS

B84113H0000B116

Single Phase EMI Filter, 250V, 50/60HzHz, METAL PACKAGE
TDK

B84113H0000G120

2−line filters SIFI−H for very high insertion loss
EPCOS

B84113H0000G120

Single Phase EMI Filter, 250V, 50/60HzHz, METAL PACKAGE
TDK

B84113H0000G125

2−line filters SIFI−H for very high insertion loss
EPCOS

B84113H0000G125

Single Phase EMI Filter, 250V, 50/60HzHz, METAL PACKAGE
TDK

B84113H0000G136

2−line filters SIFI−H for very high insertion loss
EPCOS

B84113H0000G136

Single Phase EMI Filter, 250V, 50/60HzHz, METAL PACKAGE
TDK

B84113H0000M030

2−line filters SIFI−H for very high insertion loss
EPCOS

B84113H0000M030

Single Phase EMI Filter, 250V, 50/60HzHz, METAL PACKAGE
TDK

B84113H0000M060

2−line filters SIFI−H for very high insertion loss
EPCOS

B84113H0000M110

2−line filters SIFI−H for very high insertion loss