B84312C0090B004 [EPCOS]
Filters for Communication Lines; 过滤器用于通信线路型号: | B84312C0090B004 |
厂家: | EPCOS |
描述: | Filters for Communication Lines |
文件: | 总12页 (文件大小:609K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Filters for Communication Lines
Analog Systems and Control Lines
Series/Type:
B84312
Date: January 2004
EPCOS AG 2004. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the
information contained therein without EPCOS' prior express consent is prohibited.
Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical
and Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers' Associ-
ation), unless otherwise agreed.
Filters for communication lines
Analog systems and control lines
B84312
Passband up to 300 kHz
Stopband attenuation up to 40 GHz
Features
Use of coaxial feed-through capacitors on input and output
Single or current-balanced chokes depending on requirement
Insertion loss to CISPR 17
Also available with integrated EMP protection
Installation
Single filters are attached directly to the shielding wall. Larger numbers can be housed in filter
cabinets or boxes. Various models and the matching flexible connector fittings are available.
Mechanical design
The electrical components are incorporated in an RF-tight case of tin-plated sheet steel. Filters
are available for 2 or 20 lines and for upright or flat installation on shielding wall.
Model
Installation
Filter selection
B84312C Upright
Space-saving solution for installing a number
of different filters.
B84312C*B (2-line)
B84312C*H (20-line)
B84312F Flat
Low profile and thus advantage especially for
just one or a few filters.
B84312F*B (2-line)
2
Filters for communication lines
Analog systems and control lines
B84312
Filter applications
The following standard filters are designed for the most common applications; customized models
can be produced for differing requirements.
Passband ZL
IR
Application
Circuit No. Series
diagram of
kHz
Ω
A
lines B84312
DC ... 3.4 600 0.1 Standard filters for telephone systems
1
3
2
+0020B***
20 C0020H***
+0090B***
20 C0090H***
DC ... 3.4 600 0.1 Telephone systems for enhanced
requirements (stopband attenuation of
100 dB above 10 kHz )
2
DC ... 50
600 0.1 Filters for telephone systems and
modem cables, conditionally for control
lines with critical signal rise times
1
2
+0040B***
20 C0040H***
DC ...120 150 0.1 Data signals with balanced signal
transmission mode as used
2
2
2
+0050B***
20 C0050H***
+0060B***
20 C0060H***
by modems or interfaces
DC ... 300 150 0.1
2
RS 485 up to 9600 Baud and/or
RS 422 up to 19200 Baud
DC ... 120 100
2
Smoke detectors with serial data
2
2
+0050B***
transmission in bus systems and remote
power feeding, temperature switches,
24 V emergency lighting, DC motors
20 C0050H***
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
3
1
1
24-V emergency lighting, DC motors,
signal and control lines
2
1
3
2
+0050B***
20 C0050H***
+0030B***
20 C0030H***
+0100B***
20 C0100H***
Universal filters for signal and control
lines with up to 1 A
2
Control lines with up to 1 A and
enhanced attenuation requirements
2
+: C = upright installation, F = flat installation
3
Filters for communication lines
Analog systems and control lines
B84312
Circuit diagrams
The diagrams each show a circuit of a 2-line filter.
In the series of 20-line filters there are 10 of them in each case.
Circuit diagram 1
Circuit diagram 2
Circuit diagram 3
Note on circuit diagrams 2 and 3:
These filters are mounted with current-compensated chokes. Make sure that the forward and re-
turn line are routed paired through one filter.
4
Filters for communication lines
Analog systems and control lines
B84312
General technical data
Rated voltage
Rated voltage
Rated frequency
Rated current
Line impedance
Test voltage
VR,AC 100
V
V
VR,DC 100
fR
Pass bandwidth at ZL
IR
See characteristics
See characteristics
TA = 40 °C
ZL
Vtest 250 VDC, 2 s
250 VDC, 2 s
Line/line
Line/case
Per line
Maximum DC resistance
Rmax See characteristics
Permissible ambient temperature TA
ꢀ25/+40
°C
Climatic category
(EN 60068-1)
25/085/56
ꢀ25 °C/+85 °C/56 days damp
heat test
Weight
560
4.5
C
g
2-line filters
kg 20-line filters
Mechanical version
Upright for 2- and 20-line filters
Flat for 2-line filters
F
Filters with EMP protection:
Nominal DC spark-over voltage
Surge response voltage
VsdcN <500
V
Per line
<800
<800
5/10
I ≤ IR
V
At 1 kV/µs
At 1 kV/ns
V
Nominal surge current (8/20 µs)
kA
Suppression condition
Maximum voltage on filter output for filters with EMP protection
Series
B84312 ...0020+1** ...0030+1** ...0040+1** ...0050+1** ...0060+1**
...0090+1** ...0100+1**
Pulse shape in symmetrical circuit
dv/dt = 0.1
dv/dt = 1
dv/dt = 1
kV/µs
kV/µs
kV/ns1)
2 V
1 V
360 V
60 V
2 V
8 V
3 V
3 V
2 V
12 V
9 V
0.5 V
5 V
0.5 V
12 V
0.5 V
10 V
1.2 V
12 V
Nominal surge current (8/20 µs)
290 V
Pulse shape in unsymmetrical circuit
dv/dt = 0.1
dv/dt = 1
dv/dt = 1
kV/µs
kV/µs
kV/ns1)
50 V
35 V
1 V
700 V
130 V
5 V
250 V
60 V
3 V
120 V
25 V
1 V
280 V
30 V
1 V
Nominal surge current (8/20 µs)
20 V
200 V
110 V
25 V
50 V
1) Typical test pulse: rise time 10 ns, time to half value 1500 ns, charge voltage min. 50 kV, source impedance 90
Ω
5
Filters for communication lines
Analog systems and control lines
B84312
Characteristics and ordering codes
IR
Pass
bandwidth
kHz
ZL
Rmax
Per line
Ω
Circuit
diagram
Number of Ordering code
lines
A
Ω
0.1
0.1
0.1
1
1
1
0.1
0.1
0.1
0.1
0.1
0.1
2
DC ... 3.4
DC ... 3.4
DC ... 3.4
ꢀ2)
ꢀ2)
ꢀ2)
600
600
600
3)
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
2
3
3
3
3
3
3
B84312C0020B*03
B84312F0020B*03
11
11
11
2
2
20
2
2
20
2
2
20
2
2
20
2
2
20
2
2
20
2
2
2
2
20
2
B84312C0020H*03
B84312C0030B*03
B84312F0030B*03
B84312C0030H*03
B84312C0040B*01
B84312F0040B*01
B84312C0040H*01
B84312C0050B*01
B84312F0050B*01
B84312C0050H*01
B84312C0050B*21
B84312F0050B*21
B84312C0050H*21
B84312C0050B*31
B84312F0050B*31
B84312C0050H*31
B84312C0060B*01
B84312F0060B*01
B84312C0090B*04
B84312F0090B*04
B84312C0090H*04
B84312C0100B*03
B84312F0100B*03
B84312C0100H*03
0.4
0.4
0.4
1.1
1.1
1.1
4.4
4.4
4.4
0.4
0.4
0.4
0.2
0.2
0.2
1.0
1.0
17
3)
3)
DC ... 50
DC ... 50
DC ... 50
DC ... 120
DC ... 120
DC ... 120
DC ... 120
DC ... 120
DC ... 120
ꢀ2)
600
600
600
150
150
150
100
100
2
2
3
3
100
3)
ꢀ2)
ꢀ2)
3)
3)
3
0.1
0.1
0.1
0.1
0.1
1
DC ... 300
DC ... 300
DC ... 3.4
DC ... 3.4
DC ... 3.4
ꢀ2)
150
150
600
600
17
17
0.6
0.6
0.6
600
3)
ꢀ2)
ꢀ2)
3)
3)
1
1
2
20
*: 0 = Standard filters
1 = Filters with EMP protection
2) Control line filters, not matched
3) Not specified
6
Filters for communication lines
Analog systems and control lines
B84312
Insertion loss αe in passband (typical)
Symmetrical measurement circuit
with ZL = 600 Ω
Symmetrical measurement circuit
with ZL = 150 Ω
7
Filters for communication lines
Analog systems and control lines
B84312
Unsymmetrical measurement (common-mode-rejection) in passband
Filter with ZL = 600 Ω
CMR >40 dB in passband
8
Filters for communication lines
Analog systems and control lines
B84312
Insertion loss αe in stopband (typical)
Unsymmetrical measurement circuit
Asymmetrical measurement
to MIL-STD-220A
9
Filters for communication lines
Analog systems and control lines
B84312
Dimensional drawings
2-line filters, upright installation
➀
➁
Line connections at both ends:
2 x tab connectors for receptacle 2.8 x 0.5 (in accessory bag)
Strain relief with ground connection for cable diameter 4.5 ... 6 mm
Hole for installation in shielding wall
10
Filters for communication lines
Analog systems and control lines
B84312
2-line filters, flat installation
➀
➁
Line connections at both ends:
2 x tab connectors for receptacle 2.8 x 0.5 (in accessory bag)
Strain relief with ground connection for cable diameter 4.5 ... 6 mm
Hole for installation in shielding wall
11
Filters for communication lines
Analog systems and control lines
B84312
20-line filters, upright installation
Hole for installation in shielding wall
Adapter
A bracket adapter is available for flat installation on the shielding wall.
Ordering code: B84298M0012C004
12
相关型号: