T30-A500X [EPCOS]

SURGE ARRESTER 3-electrode arrester; 避雷器3电极避雷器
T30-A500X
型号: T30-A500X
厂家: EPCOS    EPCOS
描述:

SURGE ARRESTER 3-electrode arrester
避雷器3电极避雷器

文件: 总4页 (文件大小:50K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Surge arrester  
3-electrode arrester  
Series/Type:  
T30-A500X  
Ordering code:  
B88069X3070C203  
Version/Date:  
Version:  
Issue 04 / 2007-05-08  
01  
Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the  
table and then change the color to "white" (or invisible). This ensures that the table disappears for the customer  
PDF. To update the data sheet, click on the symbol "Preview" and then "Close". Please do not alter the header or  
footer when copying the content.  
Identification/Classification 1:  
(header 1 + top left header bar)  
Surge arrester  
Identification/Classification 2:  
(header 2 + bottom left header bar)  
3-electrode arrester  
B88069X3070C203  
T30-A500X  
Ordering code:  
(top right header bar)  
Series/Type:  
(top right header bar)  
Preliminary data (optional):  
(if necessary)  
Department:  
Date:  
KB AB E / KB AB PM  
Issue 04 / 2007-05-08  
© EPCOS AG 2007. Reproduction, publication and dissemination of this document, enclosures hereto and the information  
contained therein without EPCOS' prior express consent is prohibited.  
Surge arrester  
B88069X3070C203  
T30-A500X  
3-electrode arrester  
Features  
Applications  
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
Very small size  
Extremely fast response time  
High current rating  
Stable performance over life  
Extremely low capacitance  
High insulation resistance  
RoHS-compatible  
ƒ
ƒ
ƒ
Line protection  
Station protection  
Base stations  
Electrical specifications  
DC spark-over voltage 1) 2) 4)  
500  
V
%
± 20  
Impulse spark-over voltage 4)  
at 100 V/µs - for 99 % of measured values  
- typical values of distribution  
< 1100  
< 900  
V
V
at 1 kV/µs  
- for 99 % of measured values  
- typical values of distribution  
< 1400  
< 1000  
V
V
Service life  
10 operations  
1 operation  
10 operations [5x (+) & 5x (-)] 8/20 µs 5)  
50 Hz; 1 s 5)  
10  
A
50 Hz; 0.18 s (9 cycles) 5) 30  
A
10  
10  
2
kA  
kA  
kA  
1 operation  
1 operation  
8/20 µs 5)  
10/350 µs 5)  
4)  
Insulation resistance at 100 Vdc  
> 10  
GΩ  
pF  
µs  
Capacitance at 1 MHz 4)  
Transverse delay time 3)  
< 1.5  
< 0.2  
Arc voltage at 1 A  
Glow to arc transition current  
Glow voltage  
~ 25  
~ 1  
~ 200  
V
A
V
Weight  
~ 1.4  
g
Operation and storage temperature  
Climatic category (IEC 60068-1)  
Marking, blue negative  
-40 ... +90  
40/ 90/ 21  
°C  
500 YY O  
500  
YY  
O
- Nominal voltage  
- Year of production  
- Non radioactive  
KB AB E / KB AB PM  
Issue 04 / 2007-05-08  
Please read Cautions and warnings and  
Page 2 of 4  
Important notes at the end of this document.  
Surge arrester  
B88069X3070C203  
T30-A500X  
3-electrode arrester  
1)  
At delivery AQL 0.65 level II, DIN ISO 2859  
In ionized mode  
Test according to ITU-T Rec. K.12  
Tip or ring electrode to center electrode  
Total current through center electrode, half value through  
tip respectively ring electrode.  
2)  
3)  
4)  
5)  
Terms in accordance with ITU-T Rec. K.12 and DIN 57845/VDE0845  
Dimensional drawing  
Not to scale  
Dimensions in mm  
Non controlled document  
Cautions and warnings  
ƒ
ƒ
ƒ
Surge arresters must not be operated directly in power supply networks.  
Surge arresters may become hot in case of longer periods of current stress (danger of burning).  
Surge arresters may be used only within their specified values. In case of overload, the head  
contacts may fail or the component may be destroyed.  
ƒ
Damaged surge arresters must not be re-used.  
KB AB E / KB AB PM  
Issue 04 / 2007-05-08  
Please read Cautions and warnings and  
Page 3 of 4  
Important notes at the end of this document.  
Important notes  
The following applies to all products named in this publication:  
1. Some parts of this publication contain statements about the suitability of our products for  
certain areas of application. These statements are based on our knowledge of typical  
requirements that are often placed on our products in the areas of application concerned. We  
nevertheless expressly point out that such statements cannot be regarded as binding  
statements about the suitability of our products for a particular customer application. As a  
rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them  
than the customers themselves. For these reasons, it is always ultimately incumbent on the  
customer to check and decide whether an EPCOS product with the properties described in the  
product specification is suitable for use in a particular customer application.  
2. We also point out that in individual cases, a malfunction of passive electronic components  
or failure before the end of their usual service life cannot be completely ruled out in the  
current state of the art, even if they are operated as specified. In customer applications  
requiring a very high level of operational safety and especially in customer applications in which  
the malfunction or failure of a passive electronic component could endanger human life or health  
(e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of  
suitable design of the customer application or other action taken by the customer (e.g. installation  
of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the  
event of malfunction or failure of a passive electronic component.  
3. The warnings, cautions and product-specific notes must be observed.  
4. In order to satisfy certain technical requirements, some of the products described in this  
publication may contain substances subject to restrictions in certain jurisdictions (e.g.  
because they are classed as “hazardous”). Useful information on this will be found in our  
Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more  
detailed questions, please contact our sales offices.  
5. We constantly strive to improve our products. Consequently, the products described in this  
publication may change from time to time. The same is true of the corresponding product  
specifications. Please check therefore to what extent product descriptions and specifications  
contained in this publication are still applicable before or when you place an order.  
We also reserve the right to discontinue production and delivery of products. Consequently,  
we cannot guarantee that all products named in this publication will always be available.  
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of  
the “General Terms of Delivery for Products and Services in the Electrical Industry”  
published by the German Electrical and Electronics Industry Association (ZVEI).  
7. The trade names EPCOS, EPCOS-JONES, Alu-X, Baoke, CeraDiode, CSSP, MLSC, PhaseCap,  
PhaseMod, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMID, SIOV, SIP5D, SIP5K, UltraCap,  
WindCap are trademarks registered or pending in Europe and in other countries. Further  
information will be found on the Internet at www.epcos.com/trademarks.  
Page 4 of 4  

相关型号:

T30-A90X

SURGE ARRESTER 3-electrode arrester
EPCOS

T30-A90XG

SURGE ARRESTER 3-electrode arrester
EPCOS

T3001

TELECOMMUNICATIONS PRODUCTS
PULSE

T3001NL

T3/DS3/E3/STS-1 TRANSFORMERS Extended Temperature Range
PULSE

T3001NLT

T3/DS3/E3/STS-1 TRANSFORMERS
PULSE

T3001T

T3/DS3/E3/STS-1 TRANSFORMERS
PULSE

T3002

TELECOMMUNICATIONS PRODUCTS
PULSE

T3002NL

T3/DS3/E3/STS-1 TRANSFORMERS
PULSE

T3002T

T3/DS3/E3/STS-1 TRANSFORMERS
PULSE

T30030-2CR

Analog Circuit
COOPER

T30030-2SR

Analog Circuit
COOPER

T30030-3

Analog Circuit
COOPER