ESPP-MIT1-0350BG-03-02-03 概述
Strain Gauge Pressure Transmitter
ESPP-MIT1-0350BG-03-02-03 数据手册
通过下载ESPP-MIT1-0350BG-03-02-03数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载Datasheet ESPP-MIT1
Strain Gauge Pressure Transmitter
•
•
•
•
•
•
•
•
•
•
•
•
Excellent performance at very low cost
Micro-fused technology
Pressure Type: Gauge
Calibrated & temperature compensated output
Full Scale (FS) Pressure Range: from 7 to 1000 bar
Analog Output: 4-20mA, 05.-4.5V, 1-5V, 0-5V
Compensation temperature: -10oC ... 80oC
Operating temperature: -40oC … 125oC
Total error: ≤ ±1%FS
Integrated stainless steel construction, full sealed (IP65)
Compact structure
Wide range of process interfaces
Product Summary
ES Systems has developed a series of pressure sensor transmitters featuring very good
accuracy at low cost. Each module is based on all welded hermetically sealed structure in a
single stainless-steel piece. The ESPP-MIT1 is a medium isolated pressure sensor suitable for
gas or fluid pressure measurements in harsh environments.
The output is fully calibrated and temperature compensated based on the internal
temperature sensor and the factory calibration coefficients which are stored in the embedded
memory. Thus, the transducer is ready to be installed directly to the end user system without
further processing.
ESPP-MIT1 comes with a variety of electrical interfaces output signal types and process
interfaces. It is one of the most cost-effective solutions especially when high volumes are
required.
Typical Applications
•
•
•
•
•
•
•
Central air conditioning control systems
Engineering machinery
Energy & water treatment systems
Hydraulic & pneumatic systems
Industrial process control & automatic detection systems
Pumps & compressors
Refrigeration systems
v1.5
Datasheet ESPP-MIT1
1. Operating Specifications
Characteristic
Pressure Type
Pressure Range
Min.
Typ.
Max.
Unit
-
Gauge
Up to 1000
bar
V
Power Supply (Vsupply
)
+8
+28
4
Current Consumption
mA
Total Error Band1
-
±1.0
%F.S.2
oC[oF]
oC[oF]
oC[oF]
-
Operating temperature range3
Compensated temperature range4
-40[-40]
-10[14]
-40[-40]
-
+125[257]
80[176]
+125[257]
-
Storage temperature range
Output
-
Calibrated Pressure
Output Interface (Out)
Current Output Load Resistance
Voltage Output Load Resistance
4-20mA, 0.5-4.5V, 1-5V, 0-5V5
≤ (Vsupply – 8) / 0.02
-
Ohm
Ohm
10K
Response Time6
Warm-up Time7
Media Compatibility
Material
50
msec
100
msec
Gases, Liquids
Stainless Steel 17-4PH
IP65
-
-
-
-
-
IP rating
Certifications
O-ring sealing
CE, RoHS, REACH
Viton
1 Total Error Band: The maximum deviation from ideal transfer function over the entire compensated temperature and
pressure range. Includes all errors due to offset, full scale span, pressure non-linearity, pressure hysteresis,
repeatability, thermal effect on offset, thermal effect on span and thermal hysteresis
2 % of the full scale pressure range
3 Operating temperature range: The temperature range over which the sensor will produce an output proportional to
pressure
4 Compensated temperature range: The temperature range over which the sensor will produce an output proportional
to pressure within the specified performance limits.
5 For 0-5V output, Vsupply is +11V to +28V.
6 Response Time: The time it takes for the electrical output to go from 10%FS signal to 90%FS signal and vice versa.
7 Warm-up Time: Time to the first valid pressure measurement after power is applied.
2/8
Datasheet ESPP-MIT1
2. Wiring Diagrams
2 wire (current)
3 wire (voltage)
3. Pressure Specifications (bar)
Pressure Range
Option
Over Pressure1
Burst Pressure2
Pmin
Pmax
7
0007BG
0010BG
0016BG
0030BG
0050BG
0100BG
0150BG
0250BG
0300BG
0350BG
0400BG
0600BG
0800BG
0
0
0
0
0
0
0
0
0
0
0
0
0
0
14
20
35
10
50
16
32
80
30
60
150
50
100
200
300
500
600
700
800
1200
1500
1500
250
100
150
250
300
350
400
600
800
1000
500
750
1250
1500
1750
2000
2000
2000
2000
1000BG
1
Overpressure: The maximum pressure which may safely be applied to the product for it to remain in specification
once pressure is returned to the operating pressure range. Exposure to higher pressures may cause permanent
damage to the product. Unless otherwise specified this applies to all available pressure ports at any temperature with
the operating temperature range
2
Burst pressure: The maximum pressure that may be applied to the specified port of the product without causing
escape of pressure media. Product should not be expected to function after exposure to any pressure beyond the
burst pressure
3/8
Datasheet ESPP-MIT1
4. Output Type
01. M12
02. ISO4400 (Form C )
03. Cable (0.5m)
04. Packard
Current
Voltage
Current
Voltage
Current
Black
Voltage
Black
Current
Voltage
1
Vsupply
1
-
1
2
3
-
1
-
1
2
3
4
1
-
1
2
3
-
Gnd1
Out
-
Red
-
Yellow
Red
-
3
-
2
3
3
-
Chassis
1 Note that Vsupply & Gnd are reverse polarity protected
5. Electrical Connector & Mechanical Dimensions
01. M12
02. ISO4400
03. Cable
04. Packard
1 Note all dimensions are in millimeters (mm)
In order to calculate the total height of each of the options above, the height of the mechanical dimensions must be
added to the height of the process interface (see section 5).
4/8
Datasheet ESPP-MIT1
6. Process Interface (dimensions in mm)
01. 1/2” NPT male 1
04. G1/4” male 2
07. G3/8” male 2
02. 1/4” NPT male 1
03. G1/2” male 2
05. 1/8” NPT male 1
06. G1/8” male 2
08. 1/4” NPT female 1
09. 1/8” NPT female 1
5/8
Datasheet ESPP-MIT1
6. Process Interface (dimensions in mm)
10. G1/4” Female 3
11. R1/4” male 4
12. 7/16-20 UNF-2B 5
13. M12x1 male 6
14. M14x1.5 male 7
15. M20x1.5 male 7
1 According to ANSI/ASME B1.20.1
2 According to ISO 1179-2 (DIN 3852-E)
3 According to EN837
4 According to ISO7
5 According to SAE J513
6 According to GB/T193
7 According to ISO 9974-2 (DIN 3852-E)
Note that for pressure ranges greater than 200bar, only options 02, 03, 04, 07 and 15 are available.
6/8
Datasheet ESPP-MIT1
7. Pressure Conversion Table
Option
Output Type
Equation
01.
4-20mA
02
03
04
0.5 - 4.5V
1- 5V
0- 5V
8. Ordering Information
ESPP-MIT1-NNNNNN-NN-NN-NN
Process Interface
Pressure Range Full Scale
1/2” NPT male
1/4” NPT male
G1/2” male
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
0007BG
0010BG
0016BG
0030BG
0050BG
0100BG
0150BG
0250BG
0300BG
0350BG
0400BG
0600BG
0800BG
1000BG
7 bar
10 bar
16 bar
Output Type
G1/4” male
30 bar
4-20mA
0.5-4.5V
1-5V
01
02
03
04
1/8” NPT male
G1/8” male
50 bar
100 bar
150 bar
250 bar
300 bar
350 bar
400 bar
600 bar
800 bar
1000 bar
G3/8” male
0-5V
1/4” NPT female
1/8” NPT female
G1/4” female
R1/4” male
Connector
M12
01
02
03
04
ISO4400
7/16-20 UNF-2B
M12x1 male
M14x1.5 male
M20x1.5 male
Cable (0.5m)
Packard
7/8
Datasheet ESPP-MIT1
Important Notes
No warranty applies to any party other than the original
Customer. The remedies of the Customer set forth
herein are exclusive and the total liability of ES Systems
with respect to this order, whether based on contract,
warranty, negligence, indemnification, strict liability or
otherwise, shall not exceed the purchase price of the
component upon which liability is based.
PERSONAL INJURY
DO NOT USE these products as safety or emergency
stop devices, or in any other application where
failure of the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
In no event shall ES Systems be liable for consequential,
incidental or special damages.
WARRANTY
ES Systems warrants this Product to be free of defects in
materials and workmanship for a period of one (1) year
from the date of purchase.
Specifications may change without notice. The
information supplied is believed to be accurate and
reliable as of this issue; however, ES Systems assumes no
responsibility for its use.
Upon examination by ES Systems, if the unit is found to
be defective it will be repaired or replaced at no charge.
ES Systems' WARRANTY does not apply to defects
resulting from any action of the purchaser, including but
not limited to mishandling, improper interfacing,
operation outside of design limits, improper repair, or
unauthorized modification. This WARRANTY is VOID if the
unit shows evidence of having been tampered with or
Contact Information
ES Systems S.A.
Head Office:
7, Stratigi St., GR-154 51
Neo Psychico, Greece
Tel: (+30) 210 672 8610,
Fax (+30) 210 672 8624
shows evidence of being damaged as
excessive corrosion; or current, heat, moisture or
vibration;
a result of
Factory:
57, I.Metaxa str., GR-194 41
Koropi, Greece
Tel: (+30) 216 2000 500,
Fax (+30) 216 2000 555
improper specification; misapplication; misuse or other
operating conditions outside of ES Systems' control.
Components which wear are not warranted.
ES Systems neither assumes responsibility for any
omissions or errors nor assumes liability for any
damages that result from the use of its Product in
accordance with information provided by ES Systems,
either verbal or written. ES Systems warrants only that
the parts manufactured by it will be as specified and free
of defects.
ES SYSTEMS MAKES NO OTHER WARRANTIES OR
REPRESENTATIONS OF ANY KIND WHATSOEVER,
EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND
ALL
IMPLIED
WARRANTIES
INCLUDING
ANY
WARRANTY OF MERCHANTABILITY AND FITNESS FOR
A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED.
No representative of ES Systems is authorized to extend
this Warranty or to change it in any manner whatsoever.
8/8
ESPP-MIT1-0350BG-03-02-03 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
ESPP-MIT1-0350BG-03-02-04 | ES | Strain Gauge Pressure Transmitter | 获取价格 | |
ESPP-MIT1-0350BG-03-02-05 | ES | Strain Gauge Pressure Transmitter | 获取价格 | |
ESPP-MIT1-0350BG-03-02-06 | ES | Strain Gauge Pressure Transmitter | 获取价格 | |
ESPP-MIT1-0350BG-03-02-07 | ES | Strain Gauge Pressure Transmitter | 获取价格 | |
ESPP-MIT1-0350BG-03-02-08 | ES | Strain Gauge Pressure Transmitter | 获取价格 | |
ESPP-MIT1-0350BG-03-02-09 | ES | Strain Gauge Pressure Transmitter | 获取价格 | |
ESPP-MIT1-0350BG-03-02-10 | ES | Strain Gauge Pressure Transmitter | 获取价格 | |
ESPP-MIT1-0350BG-03-02-11 | ES | Strain Gauge Pressure Transmitter | 获取价格 | |
ESPP-MIT1-0350BG-03-03-01 | ES | Strain Gauge Pressure Transmitter | 获取价格 | |
ESPP-MIT1-0350BG-03-03-02 | ES | Strain Gauge Pressure Transmitter | 获取价格 |
ESPP-MIT1-0350BG-03-02-03 相关文章
- 2024-11-08
- 22
- 2024-11-08
- 15
- 2024-11-08
- 16
- 2024-11-08
- 14