106-M2-PR-PR3-10A [ETAL]
Motors, transformers, solenoids, printed circuit boards, hand-held machines and appliances, marine applications, caravans.;型号: | 106-M2-PR-PR3-10A |
厂家: | ETAL Group |
描述: | Motors, transformers, solenoids, printed circuit boards, hand-held machines and appliances, marine applications, caravans. |
文件: | 总4页 (文件大小:347K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Thermal Overcurrent Circuit Breakers 104/105/106-...
Description
Miniaturised single pole thermal circuit breaker with push-to-reset,
tease-free, trip-free, snap action mechanism (R-type TO CBE to EN
60934). Available in versions for PCB or panel mounting, snap-in or
threadneck, or as an integral type. Approved to CBE standard EN
60934 (IEC 60934). For higher current ratings see type 1140.
Typical applications
Motors, transformers, solenoids, printed circuit boards, hand-held
machines and appliances, marine applications, caravans.
1
104-...
105-...
106-...
Ordering information
Type No.
Technical data
104
105
106
PCB mounting type (-PR), or integral type (-P30/P10)
snap-in panel mounting
threadneck panel mounting with metal hex and plastic knurled nut
(hardware bulk shipped with 5 pcs plus)
For further details please see chapter: Technical Information
Voltage rating
AC 240 V; DC 48 V
(UL: AC 250 V; DC 48 V)
106-M2 threadneck panel mounting 3/8-27UNS with collar, metal hex nut
and plastic knurled nut (hardware bulk shipped with 5 pcs plus)
Terminal design
Current ratings
Typical life
0.05...10 A
P10 blade terminals A6.3-0.8 (QC .250)
P30 blade terminals A2.8-0.8 (QC .110)
0.05...5 A 1,000 operations at 2 x IN, inductive
DC 28 V: 3,000 operations at 2 x IN, inductive
PR
solder terminal pins for PCB mounting (type 104 only)
6...8 A
10 A
500 operations at 2 x IN, inductive
50 operations at 2 x IN, inductive
PR3 PCB mounting (vertical), type 104 only
Current ratings
Ambient temperature
-20...+60 °C (-4...+140 °F) T 60
0.05...10 A
Insulation co-ordination
(IEC 60664 and 60664 A) withstand voltage
2.5 kV
rated impulse
pollution
degree
2
106
-
P30 - 5 A ordering example
The exact part number required can be built up from the table of choices shown
above. Ordering references for optional features should be omitted if not required.
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A)
operating area
test voltage
AC 3,000 V
Preferred types
Insulation resistance
> 100 MΩ (DC 500 V)
Interrupting capacity Icn
0.05...8 A
0.05...10 A 6 x IN DC
6 x IN AC
Preferred types Standard current ratings (A)
0.5 0.8
1
x
1.2 1.5
2
x
3
x
4
x
5
x
6
x
8
x
10
x
Interrupting capacity
(UL 1077)
IN
UN
AC 250 V
DC 48 V
x
x
x
x
106-P10-
106-P30-
0.05...10 A
0.05...10 A
2,000 A
200 A
x
x
x
x
x
x
x
x
x
x
x
x
Degree of protection
(IEC 60529/DIN 40050)
operating area IP40
terminal area IP00
Standard current ratings and typical internal resistance values
Vibration
10 g (57-500 Hz) 0.76 mm (10-57 Hz),
to IEC 60068-2-6, test Fc,
10 frequency cycles/axis
Current
rating (A)
Internal
Current
Internal
resistance (Ω)
Shock
25 g (11 ms) to IEC 60068-2-27, test Ea
resistance (Ω) rating (A)
Corrosion
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
0.05
0.08
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
1
285
134
81
1.8
2
0.28
Humidity
Mass
240 hours at 95 % RH,
to IEC 60068-2-78, test Cab
0.25
2.5
3
0.18
approx. 10 g
22
0.11
8.7
5.5
3.3
2.45
1.6
1.45
0.9
0.6
0.4
3.5
4
0.076
0.067
0.051
≤ 0.05
≤ 0.05
≤ 0.05
≤ 0.05
≤ 0.05
Approvals
Authority
Standard
Rated voltage
Current ratings
4.5
5
VDE /SEV
IEC/EN 60934 AC 240 V
DC 48 V
0.02 A… 8 A
0.02 A…10 A
6
UL
UL1077
AC 250 V
DC 48 V
0.05 A…10 A
0.05 A…10 A
7
CSA
CQC
C22.2 No 235
GB 17701
AC 250 V
DC 48 V
0.05 A…10 A
0.05 A…10 A
8
1.2
1.5
10
AC 240 V
DC 48 V
0.05 A…8 A
0.05 A…10 A
1628
www.e-t-a.de
1
Thermal Overcurrent Circuit Breakers 104/105/106-...
Dimensions
104-ꢀꢁ
104-P30
ø7
.276
ꢈꢇ
ꢁ1ꢄꢃ
ø4
.157
1
ꢖꢝꢞ ꢊꢓꢟꢌꢇꢋꢌꢑ ꢠꢓꢎꢈꢐ
1ꢀꢅꢕꢖꢗ
blade terminals
DIN 46244-A2.8-0.8
(QC .110)
1ꢀꢅꢕꢖꢗ
ꢃꢁꢁꢁ1ꢀ ꢘ
hole for mounting
screw M2 usable depth
4.5 mm (.177 in.)
1ꢀꢅꢕꢖꢗꢕꢘꢆ
ꢀꢁꢀꢄꢁꢁꢁ6 ꢘ
cut-out dimensions
6.5
.256
ꢀꢁꢄ
ꢁꢀ2ꢀ
ꢀꢁꢄ
ꢁꢀ2ꢀ
ꢇꢈꢉꢊꢋꢌꢍꢎ ꢏꢈꢐꢋꢑꢌ ꢒꢓꢉ
ꢔꢓꢉꢉꢈꢔꢇ ꢐꢇꢍꢌꢏꢕꢓꢒꢒ ꢏꢋꢐꢇꢍꢌꢔꢈꢐ
6.5
.256
1
ꢀꢁ8
ꢁꢀꢆꢂ
ꢁꢀꢆ1
9
.354
19
.748
1
ꢆ
2
1
2
ꢂꢁ1
ꢁꢆꢄ8
104-P30
7...10 A
8
ꢀꢁ2
1ꢃꢁꢄ
ꢁ68ꢂ
1ꢂꢁ2
ꢁꢃꢄ6
21
ꢀꢁ1ꢃ ꢀꢂꢂ8
ꢙ1ꢁꢄ
ꢁꢀꢄꢂ
ꢂꢁꢄ
ꢁꢆꢃꢅ
1ꢃꢁꢄ
ꢁ68ꢂ
ꢂꢁꢄ
ꢁꢆꢃꢅ
8
ꢀꢁ2
ꢁꢆ1ꢄ ꢁꢀꢀ8
ꢁ82ꢃ
104-ꢀꢁꢂ
ꢂꢀꢂꢃꢀꢀꢀ6 ꢅ
105-P30
ꢈꢄ
ø7
.276
ø4
.157
ꢀ2ꢄ6
ꢈꢇ
ꢀ1ꢃꢄ
11
.433
19
.748
ꢇ
ꢀ1ꢃꢄ
1ꢀ2
ꢖꢗꢙꢕ
blade terminals
ꢂꢀ8
ꢀꢂꢁ1
DIN 46244-A2.8-0.8
(QC .110)
ꢂꢀꢆ
ꢖꢗꢚꢔ
1ꢃꢀꢇ
ꢀ6ꢂ6
panel cut-out
1ꢀ2
ꢖꢗꢙꢕ
a
12
.472
ꢀꢁꢂ ꢃꢄꢅꢆꢇꢈꢆꢉ ꢊꢄꢋꢌꢍ
ꢗꢖꢗꢔꢖꢖꢖ6 ꢘ
25
.984
ꢊꢄꢋꢌ ꢎꢄꢏ ꢃꢄꢅꢆꢇꢈꢆꢉ ꢍꢐꢏꢌꢑ ꢒ2ꢓꢔ
6ꢀꢃ
ꢀ2ꢃ6
ꢄꢀꢄ
ꢖꢚꢗꢚ
d
a
b
mm
0.8
1.0
1.5
inch
.031
.039
.059
mm inch
21.9 .862
11.3 +0.3
.445 +.012
22
.866
ꢆꢀ1
ꢀꢁꢃ8
1ꢃꢀꢇ
ꢖ6ꢗ6
22.1 .870
1ꢆꢀ2
ꢀꢄꢃ6
2-3 .079-.118 22.2 .874
105-P3
07...10 A
ꢕꢖꢖꢖ1ꢗ ꢘ
ꢃꢀꢇ
ꢀ21ꢁ
ꢄꢀꢀꢀ1ꢂ ꢅ
ꢄꢀꢄ
ꢀꢁꢂꢁ
ꢃꢀꢇ
ꢇ
ꢀ1ꢃꢄ
ꢀ21ꢁ
mm
inch
This is a metric design and millimeter dimensions take precedence (
)
2
www.e-t-a.de
1628
Thermal Overcurrent Circuit Breakers 104/105/106-...
Dimensions
Installation drawings
ꢁꢍꢉꢈꢇꢄꢅꢃꢆ ꢇꢈꢉꢇ
104-ꢀ
106-P30
3/8-27UNS-2A
tightening torque max. 0.8 Nm
ø4
.157
1
ꢀꢁꢂꢃꢄꢅꢃꢆ ꢇꢈꢉꢇ
ꢁꢍꢉꢈꢇꢄꢅꢃꢆ ꢇꢈꢉꢇ
8
ꢊꢋ1ꢌ
8
ꢊꢋ1ꢌ
19
.748
11
.433
blade terminals
DIN 46244-A2.8-0.8
(QC .110)
105-ꢀ
15.7
.618
SW14
mounting hole
.551
9.6- 0.1
.378 - .004
9
.354
106-P30
7...10 A
8
8
ꢊꢋ1ꢌ
ꢊꢋ1ꢌ
ꢀꢁꢂꢃꢄꢅꢃꢆ ꢇꢈꢉꢇ
ꢁꢍꢉꢈꢇꢄꢅꢃꢆ ꢇꢈꢉꢇ
106-ꢀ
106-M2
3/8-27UNS-2A
tightening torque max. 0.8 Nm
mounting hole
9.6- 0.1
.378 - .004
8
ꢀꢁꢂꢃꢄꢅꢃꢆ ꢇꢈꢉꢇ
8
ꢊꢋ1ꢌ
ꢊꢋ1ꢌ
Terminal design
104/105/106-P10
0.05...6 A
Internal connection diagrams
7...10 A
blade terminals
DIN 46244-A6.3-0.8
(QC .250)
Types 104
105
106
1
6.3
.248
polarizing tooth
2
mm
)
This is a metric design and millimeter dimensions take precedence (
inch
1628
www.e-t-a.de
3
Thermal Overcurrent Circuit Breakers 104/105/106-...
Typical time/current characteristics at +23 °C/+73.4 °F
Accessories
ꢀateꢁ ꢂꢃꢄaꢂꢅ ꢆꢇꢈeꢁ ꢉtꢁaꢊꢂꢃaꢁeꢊtꢋꢌꢍꢊꢎꢁꢄed ꢊꢎt aꢂꢂeꢏꢐꢄꢑ
ꢀꢁꢂꢃꢄ 1ꢅ6ꢆꢇꢇꢇ ꢈꢉꢊꢂꢋ
ꢒ ꢓꢔꢕ ꢓꢖꢗ ꢔꢕ ꢀꢌꢍ6ꢎꢋ
1ꢂꢂꢂꢂ
ꢂꢒꢂꢓ ꢔ 6 ꢕ
ꢖ ꢔ 1ꢂ ꢕ
1ꢂꢂꢂ
1ꢂꢂ
1ꢂ
1
1
ꢘꢊꢎꢁꢄed ꢊꢎt ꢙꢌꢖꢚꢛ ꢃꢄaꢂtꢜꢆ ꢉꢂtaꢊdaꢁdꢋ
ꢝ ꢙꢔꢞ ꢕꢕꢞ ꢔꢓ
ꢏ1ꢐ
ꢇꢐꢘ1
ꢑ
ꢇ118
ꢂꢒ1
ꢑꢒ8ꢆ2ꢓꢔꢕꢖꢆ2ꢗ
1
2
ꢀ
6
8 1ꢂ
2ꢂ
ꢁꢂ
ꢏ ꢇꢅꢈꢉꢋ ꢄꢐꢇꢉꢎ ꢌꢑꢄꢄꢉꢊꢇ
The time/current characteristic curve depends on the ambient temperature
prevailing. In order to eliminate nuisance tripping, please multiply the
circuit breaker current ratings by the derating factor shown below. See also
section Technical information.
ꢟeꢠ ꢊꢎt ꢙꢌꢖꢚꢛ ꢊꢜꢆꢍeꢄ-ꢃꢄated ꢐꢁaꢂꢂ
ꢝ ꢙꢔꢔ ꢕꢡꢓ ꢔꢕ
ꢑꢒ8ꢆ2ꢓꢔꢕꢖꢆ2ꢗ
2ꢇꢐ
ꢇꢅꢘ8
-4
-20
+14
-10
+32 +73.4 +104 +122 +140
Ambient temperature °F
°C
0
+23
+40
+50
+60
0.76 0.84 0.92
1
1.08 1.16 1.24
Derating factor
ꢖꢙ1ꢎ
ꢇꢐꢐ1
mm
inch
This is a metric design and millimeter dimensions take precedence (
)
All dimensions without tolerances are for reference only. In the interest of improved design,
performance and cost effectiveness the right to make changes in these specifications
without notice is reserved.Product markings may not be exactly as the ordering codes.
Errors and omissions excepted.
4
www.e-t-a.de
1628
相关型号:
106-M2-PR-PR3-5A
Motors, transformers, solenoids, printed circuit boards, hand-held machines and appliances, marine applications, caravans.
ETAL
106-P10-0.05A
Motors, transformers, solenoids, printed circuit boards, hand-held machines and appliances, marine applications, caravans.
ETAL
106-P10-10A
Motors, transformers, solenoids, printed circuit boards, hand-held machines and appliances, marine applications, caravans.
ETAL
106-P10-5A
Motors, transformers, solenoids, printed circuit boards, hand-held machines and appliances, marine applications, caravans.
ETAL
106-P30-0.05A
Motors, transformers, solenoids, printed circuit boards, hand-held machines and appliances, marine applications, caravans.
ETAL
106-P30-10A
Motors, transformers, solenoids, printed circuit boards, hand-held machines and appliances, marine applications, caravans.
ETAL
106-P30-5A
Motors, transformers, solenoids, printed circuit boards, hand-held machines and appliances, marine applications, caravans.
ETAL
©2020 ICPDF网 联系我们和版权申明