1657-G11-00-S83-7A [ETAL]

Power tools, Industrial equipment, Medical equipment, Power generators, Motors, Battery chargers, UPS;
1657-G11-00-S83-7A
型号: 1657-G11-00-S83-7A
厂家: ETAL Group    ETAL Group
描述:

Power tools, Industrial equipment, Medical equipment, Power generators, Motors, Battery chargers, UPS

电池
文件: 总4页 (文件大小:131K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Thermal Overcurrent Circuit Breaker 1657-...  
Description  
Single pole thermal reset circuit breaker in a miniaturised design  
intended for thread neck mounting. Easy and quick reset after  
tripping due to overcurrent. Trip-free mechanism and automatic  
disconnection in the event of an overcurrent, even with a blocked  
actuator button. R-Type TO CBE to EN60934. Very cost effective  
design to meet international requirements.  
lManual reset, trip free mechanism  
lExtremely small and lightweight  
Typical applications  
1
1657-...  
Power tools, Industrial equipment, Medical equipment, Power generators,  
Motors, Battery chargers, UPS.  
Technical data  
Ordering information  
Voltage rating  
Current ratings  
AC 250 V, DC 32 V  
Type No.  
5...12 A inductive load  
13...20 A resistive load  
1657 single pole thermal circuit breaker, black body  
Threadneck design  
G11 M11x1,0 (Plastic), white push-to-reset button  
G12 M11x1,0 (Plastic), black push-to-reset button  
G21 3/8“-24 UNF (Plastic), white push-to-reset button  
G22 3/8“-24 UNF (Plastic), black push-to-reset button  
Hardware  
Typical life  
500 operations at 1.5 x In resistive  
AC 125 V  
operat. IN  
UN  
Behaviour at rated  
switching capacity  
(EN 60934;  
40  
40  
5...12 A AC 250 V  
5...20 A DC 32 V  
6 x In ind.  
4 x In ind.  
00 no hardware  
01 one integrated knurled nut (plastic),  
Y 310 777 01 for M11, Y 310 778 01 for 3/8", bulk  
Terminals  
test sequence D)  
Ambient temperatur  
-10 °C to +60 °C (+14...+140° F)  
P10 blade terminals A6.3-0,8 (QC .250)  
P13 blade terminals A6.3-0,8 (QC .250), 90°  
S83 bent screw terminals 8-32 UNC  
Current ratings  
Insulation co-ordination  
(IEC 60664)  
2,5 kV/2 reinforced insulation in  
operating area  
Dielectric strength  
operating area  
5/6/7/8/10/12/15/20 A  
test voltage AC 3,000 V  
> 500 MΩ  
Insulation resistance  
1657-G21 -01 - P10 -5 A  
Ordering example  
Interrupting capacity (Icn  
)
IN  
UN  
5...12 A AC 250 V 6 x In  
Standard current ratings and typical resistance  
5...20 A DC 32 V  
6 x In  
INC  
Interrupting capacity  
(UL 1077)  
IN  
UN  
Current  
rating (A)  
Typical  
Current  
Typical  
Resistance (Ω)  
Resistance (Ω) rating (A)  
5...20 A  
5...20 A  
5...20 A  
AC 250 V 1000 A, C, 1  
AC 250 V 400 A, U, 3  
DC 50 V 300 A, C, 1  
5 A  
6 A  
7 A  
8 A  
0.225  
0.175  
0.175  
0.175  
10 A  
12 A  
15 A  
20 A  
0.125  
0.125  
0.050  
0.040  
Degree of protection  
(IEC 60529)  
operating area IP40  
terminal area IP00  
Vibration  
57 Hz acceleration 30m/s2 (3 g)  
in X.Y.Z. direction (2 timesl/min.)  
Shock  
Mass  
300m/s2 (30 g) in X.Y.Z. direction  
approx. 14 g  
Approvals  
Authority Standard  
Voltage rating  
Current ratings  
UL  
UL 1077  
(E67320)  
AC 250 V  
DC 50 V  
5 A...20 A  
5 A...20 A  
TÜV SÜD EN 60934 /  
IEC 60934  
AC 250 V  
DC 32 V  
5 A...12 A  
5 A...20 A  
UL  
UL 1500  
AC 250 V  
DC 50 V  
5 A...20 A  
5 A...20 A  
050215  
www.e-t-a.de  
1
Thermal Overcurrent Circuit Breaker 1657-...  
Dimensions  
Terminal design  
1
Internal connection diagram  
Panel cut out  
Installation drawing  
mm  
inch  
This is a metric design and millimeter dimensions take precedence (  
)
2
www.e-t-a.de  
050215  
Thermal Overcurrent Circuit Breaker 1657-...  
Typical time/current characteristics  
Accessories  
1
The time/current characteristic curve depends on the ambient temperature  
prevailing. In order to eliminate nuisance tripping, please multiply the circuit  
breaker current ratings by the derating factor shown below. See also section  
Technical information.  
Ambient temp. °F  
Ambient temp. °C  
+14 +32 +50 +77 +95 +104 +122 +140  
-10  
0
10  
25  
35  
40  
50  
60  
Derating factor  
0.77 0.83 0.91  
1
1.06 1.18 1.37  
1.47  
mm  
inch  
This is a metric design and millimeter dimensions take precedence (  
)
All dimensions without tolerances are for reference only. In the interest of improved design,  
performance and cost effectiveness the right to make changes in these specifications  
without notice is reserved.Product markings may not be exactly as the ordering codes.  
Errors and omissions excepted.  
050215  
www.e-t-a.de  
3
1
4
www.e-t-a.de  
050215  

相关型号:

1657-G11-00-S83-8A

Power tools, Industrial equipment, Medical equipment, Power generators, Motors, Battery chargers, UPS
ETAL

1657-G11-01-P10-10A

Power tools, Industrial equipment, Medical equipment, Power generators, Motors, Battery chargers, UPS
ETAL

1657-G11-01-P10-12A

Power tools, Industrial equipment, Medical equipment, Power generators, Motors, Battery chargers, UPS
ETAL

1657-G11-01-P10-15A

Power tools, Industrial equipment, Medical equipment, Power generators, Motors, Battery chargers, UPS
ETAL

1657-G11-01-P10-20A

Power tools, Industrial equipment, Medical equipment, Power generators, Motors, Battery chargers, UPS
ETAL

1657-G11-01-P10-5A

Power tools, Industrial equipment, Medical equipment, Power generators, Motors, Battery chargers, UPS
ETAL

1657-G11-01-P10-6A

Power tools, Industrial equipment, Medical equipment, Power generators, Motors, Battery chargers, UPS
ETAL

1657-G11-01-P10-7A

Power tools, Industrial equipment, Medical equipment, Power generators, Motors, Battery chargers, UPS
ETAL

1657-G11-01-P10-8A

Power tools, Industrial equipment, Medical equipment, Power generators, Motors, Battery chargers, UPS
ETAL

1657-G11-01-P13-10A

Power tools, Industrial equipment, Medical equipment, Power generators, Motors, Battery chargers, UPS
ETAL

1657-G11-01-P13-12A

Power tools, Industrial equipment, Medical equipment, Power generators, Motors, Battery chargers, UPS
ETAL

1657-G11-01-P13-15A

Power tools, Industrial equipment, Medical equipment, Power generators, Motors, Battery chargers, UPS
ETAL