1658-A00-00-P10-7A [ETAL]

Battery chargers, consumer products, power supplies, motors;
1658-A00-00-P10-7A
型号: 1658-A00-00-P10-7A
厂家: ETAL Group    ETAL Group
描述:

Battery chargers, consumer products, power supplies, motors

电池
文件: 总4页 (文件大小:267K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Thermal Overcurrent Circuit Breaker 1658-...  
Description  
Very cost effective design to meet international requirements. No  
exposed metal parts which are, or could become, current-carrying  
except for terminals. R-type TO CBE to EN 60934.  
l
l
l
Manual reset, cycling trip free mechanism  
Extremely small and lightweight  
UL, CSA, VDE and EN 60934 (IEC 60934) approved  
Typical applications  
Battery chargers, consumer products, power supplies, motors.  
1
1658-...  
Ordering information  
Type No.  
Technical data  
1658 single pole thermal circuit breaker  
Threadneck design  
G21 manual reset type, 3/8“-27 threadneck  
A00 auto reset type, without threadneck  
Hardware  
For further details please see chapter: Technical Information  
Voltage rating  
Current ratings  
AC 240 V; DC 28 V  
5...30 A  
00 no hardware  
01 one PAL nut Y306 671 01, bulk  
02 one PAL nut Y306 671 01,  
one knurled nut Y307 117 02, bulk  
Terminals  
Typical life  
AC + DC  
5...16 A  
1,000 operations at 2 x IN, inductive  
17...25 A 1,000 operations at 2 x IN, resistive  
P10 blade terminals A6.3-0.8 (QC .250)  
P13 blade terminals A6.3-0.8 (QC .250), 90°  
Current ratings  
operat.  
IN  
UN  
Behaviour at rated  
switching capacity  
(EN 60934;  
40  
40  
40  
5...16 A  
5...16 A  
AC 240 V 6 x IN ind  
5 ...30 A  
test sequence D)  
DC 28 V  
4 x IN ind  
1658 - G21 - 02 - P10 - 5 A  
Ordering example  
17...25 A AC 240 V 120 A  
resistive  
120 A  
resistive  
* Screws and lock washers bulk shipped  
40  
17...25 A DC 28 V  
Packaging unit: minimum order quantity 250 pieces  
Ambient temperature  
-20...+60 °C (-4...+140 °F),  
≤ 7 A max. +40 °C (+104 °F)  
Preferred types  
Insulation co-ordination rated impulse  
(IEC 60664 and 60664 A) withstand voltage  
2.5 kV  
pollution  
degree  
Preferred types Standard current ratings (A)  
2
reinforced insulation in operating area  
5
6
7
8
9
10 12 15 16 20 25 30  
Dielectric strength  
x
x
x
x
x
x
x
x
x
x
x
x
1658-G21-02-P10-  
(IEC 60664 and 60664A) test voltage  
operating area  
AC 3,000 V  
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
1658-G21-02-P13-  
1658-A00-00-P10-  
Insulation resistance  
> 100 MΩ (DC 500 V)  
Interrupting capacity Icn 5...7 A  
8...30 A  
180 A  
200 A  
Interrupting capacity  
(UL 1077/EN 60934 PC1) 5...16 A  
IN  
UN  
Standard current ratings and typical voltage drop values  
AC 240 V 2,000 A  
5...30 A  
5...30 A  
5...30 A  
AC 120 V 2,000 A  
DC 32 V 2,500 A  
DC 28 V 2,000 A (1658-A..)  
Current  
rating (A)  
voltage drop  
values (mV)  
Current  
rating (A)  
voltage drop  
values (mV)  
Degree of protection  
(IEC 60529/DIN 40050)  
operating area IP40  
terminal area IP00  
5
≤ 250  
≤ 250  
≤ 250  
≤ 250  
≤ 250  
≤ 250  
12  
15  
16  
20  
25  
30  
≤ 250  
≤ 250  
≤ 250  
≤ 250  
≤ 250  
≤ 250  
6
Vibration  
8 g (57-500 Hz) 0.61 mm (10-57 Hz),  
to IEC 60068-2-6, test Fc,  
10 frequency cycles/axis  
7
8
Shock  
30 g (11 ms)  
to IEC 60068-2-27, test Ea  
9
Corrosion  
Humidity  
Mass  
96 hours at 5 % salt mist,  
to IEC 60068-2-11, test Ka  
10  
240 hours at 95 % RH  
to IEC 60068-2-78, test Cab  
approx. 16 g  
1635  
www.e-t-a.de  
1
Thermal Overcurrent Circuit Breaker 1658-...  
Dimensions  
Internal connection diagram  
ø6  
1
.236  
1
2
17.5  
.689  
Typical time/current characteristics  
1
15.7  
.618  
1ꢃꢃꢃꢃ  
1ꢃꢃꢃ  
ꢔ6ꢃ ꢕꢖ  
ꢔ1ꢁꢃ ꢕꢗ  
32  
1.26  
ꢔꢀ3 ꢕꢖ  
ꢔꢘ3ꢓꢁ ꢕꢗ  
ꢙꢀꢃ ꢕꢖ  
ꢙꢁ ꢕꢗ  
A00  
1ꢃꢃ  
1ꢃ  
1
tightening torque max. 0.8 Nm  
3/8-27UNS-2A  
G21  
See ordering information for mounting hardware.  
ꢃꢓ1  
1
6
ꢂ 1ꢃ  
ꢀꢃ  
ꢁꢃ  
Terminal design  
ꢄ ꢅꢆꢇꢈꢉ ꢊꢋꢅꢈꢌ ꢍꢎꢊꢊꢈꢏꢅ  
P13  
P10  
The time/current characteristic curve depends on the ambient temperature  
prevailing. In order to eliminate nuisance tripping, please multiply the circuit  
breaker current ratings by the derating factor shown below. See also section  
Technical information.  
1
2
1
2
8.5  
.335  
blade terminals DIN 46244-A6.3-0.8 (QC .250)  
angled 90°  
Ambient temp. °F  
Ambient temp. °C  
-4  
-20  
+14  
-10  
+32 +73.4 +104 +122 +140  
blade terminals DIN 46244-A6.3-0.8  
(QC .250)  
0
+23  
+40  
+50 +60  
Derating factor IN > 7A 0.83 0.85  
0.9  
1
1
1.1  
1.23  
1.18 1.25  
IN < 7A 0.74 0.76 0.82  
-
-
Installation drawing  
ꢂꢋꢊꢉꢈꢅꢆꢄꢇ ꢈꢉꢊꢈ  
1
5
5
ꢎ1ꢏꢍ  
ꢎ1ꢏꢍ  
ꢎ15ꢍ  
ꢎ15ꢍ  
ꢁꢂꢃꢄꢅꢆꢄꢇ ꢈꢉꢊꢈ  
mm  
inch  
This is a metric design and millimeter dimensions take precedence (  
)
2
www.e-t-a.de  
1635  
Thermal Overcurrent Circuit Breaker 1658-...  
Accessories  
Reset button seal for 3/8", 27-thread,  
PAL nut 3/8", 27-thread  
Y 306 671 01  
short  
long  
X 201 285 01 (IP64)  
X 200 799 01 (IP64)  
1ꢃꢂ3  
ꢇꢂ5  
ꢋ563  
ꢋꢎꢍꢏ  
ꢁꢂ5  
ꢋꢎꢊꢎ  
3/8-27 UNS-2B  
3/8-27 UNS-2B  
3ꢄꢅꢆꢇꢈꢉꢊꢋꢆꢇꢌ  
1
Knurled nut 3/8", 27-thread  
plastic (standard)  
Y 307 117 02  
Panel cut out  
1658-3/8-27 UNS-2A  
ꢀ15  
3
ꢋ5ꢍ1  
ꢋ11ꢏ  
Ø 9,6  
3ꢄꢅꢆꢇꢈꢉꢊꢋꢆꢇꢌ  
Knurled nut 3/8", 27-thread  
nickel-plated brass  
Y 300 190 03  
Approvals  
ꢉ13  
ꢊꢋ5  
Authority Standard  
Rated voltage Current ratings  
1658-G  
AC 240 V  
ꢋ51ꢊ  
ꢋꢎꢍꢏ  
VDE  
UL  
IEC/EN 60934  
5 A…25 A  
5 A…25 A  
DC 28 V  
3ꢐꢏꢃꢊꢑꢒꢓꢁꢃꢊꢆ  
UL 1077  
AC 250 V  
AC 240 V  
AC 125 V  
DC 32 V  
5 A…15 A  
5 A…16 A  
5 A…30 A  
5 A…30 A  
CSA C22.2 No 235  
UL 1500  
Ignition Protected  
Hex nut 3/8", 27-thread  
nickel-plated brass  
Y 300 192 01  
CSA  
CSA C22.2 No 235 AC 250 V  
AC 240 V  
5 A…15 A  
5 A…16 A  
5 A…30 A  
5 A…30 A  
AC 125 V  
DC 32 V  
3ꢐꢏꢃꢊꢑꢒꢓꢁꢃꢊꢆ  
ꢊꢋ5  
ꢋꢎꢍꢏ  
1658-A  
VDE  
UL  
IEC/EN 60934  
UL 1077  
AC 240 V  
DC 28 V  
5 A…25 A  
5 A…25 A  
AC 125 V  
DC 28 V  
5 A…30 A  
5 A…30 A  
ꢁꢔ1ꢌ  
ꢋ551  
Press to Reset Plate for 3/8"  
thread, aluminium  
Y 301 059 02  
ꢉꢊ1ꢋꢌ  
ꢋꢏꢌ3  
ꢁꢂꢃ  
ꢋꢎ16  
ꢏ  
ꢉꢍꢋꢍ  
ꢋ3ꢍꢎ  
mm  
)
This is a metric design and millimeter dimensions take precedence (  
inch  
All dimensions without tolerances are for reference only. In the interest of improved design,  
performance and cost effectiveness the right to make changes in these specifications  
without notice is reserved.Product markings may not be exactly as the ordering codes.  
Errors and omissions excepted.  
1635  
www.e-t-a.de  
3
1
4
www.e-t-a.de  
1635  

相关型号:

1658-A00-00-P10-8A

Battery chargers, consumer products, power supplies, motors
ETAL

1658-A00-00-P13-10A

Battery chargers, consumer products, power supplies, motors
ETAL

1658-A00-00-P13-12A

Battery chargers, consumer products, power supplies, motors
ETAL

1658-A00-00-P13-15A

Battery chargers, consumer products, power supplies, motors
ETAL

1658-A00-00-P13-20A

Battery chargers, consumer products, power supplies, motors
ETAL

1658-A00-00-P13-30A

Battery chargers, consumer products, power supplies, motors
ETAL

1658-A00-00-P13-5A

Battery chargers, consumer products, power supplies, motors
ETAL

1658-A00-00-P13-6A

Battery chargers, consumer products, power supplies, motors
ETAL

1658-A00-00-P13-7A

Battery chargers, consumer products, power supplies, motors
ETAL

1658-A00-00-P13-8A

Battery chargers, consumer products, power supplies, motors
ETAL

1658-A00-01-P10-10A

Battery chargers, consumer products, power supplies, motors
ETAL

1658-A00-01-P10-12A

Battery chargers, consumer products, power supplies, motors
ETAL