413-K14-LN2-90A [ETAL]

Extra low voltage wiring systems on all types of vehicles for land, sea and air; defence equipment; battery powered machines;
413-K14-LN2-90A
型号: 413-K14-LN2-90A
厂家: ETAL Group    ETAL Group
描述:

Extra low voltage wiring systems on all types of vehicles for land, sea and air; defence equipment; battery powered machines

电路保护
文件: 总4页 (文件大小:209K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
High Performance Thermal Circuit Breaker 413-...  
Description  
Single pole high performance thermal circuit breaker with tease-free,  
trip-free, snap action mechanism and push/pull on/off manual actuation  
(M-type TO CBE to EN 60934). An indicator band on the push button  
clearly shows the tripped/off position. Threadneck panel mounted  
and available in tracked vehicle, aircraft and general purpose versions.  
Typical applications  
Extra low voltage wiring systems on all types of vehicles for land, sea  
and air; defence equipment; battery powered machines.  
1
413-...  
Ordering information  
Type No.  
Technical data  
413  
threadneck panel mounting  
Terminal design  
K14 screw terminals M6 (to aircraft specs.)  
K54 reinforced screw terminals M6, housing sealed  
Version  
Voltage rating  
DC 28 V  
AC 115 V (400 Hz) upon request  
Current rating range  
30...55 A (-FN2)  
30...90 A (-LN2/-N2),  
FN2 vehicle application, nickel-plated  
LN2 aircraft application, black finish  
N2  
general application, nickel-plated  
Current ratings  
30...55 A (-FN2)  
Typical life  
2,000 operations at 1 x IN  
-55...+75 °C (-67...+167 °F)  
Ambient temperature  
Insulation co-ordination  
(IEC 60664 and 60664A) withstand voltage  
1.5 kV  
rated impulse  
pollution  
degree  
3
30...90 A (-LN2/N2)  
413 - K14 - LN2 - 40 A  
ordering example  
Dielectric strength  
(IEC 60664 and 60664A) test voltage  
operating area  
AC 1,500 V  
Preferred types  
Insulation resistance  
Interrupting capacity Icn  
> 100 MΩ (DC 500 V)  
6,000 A  
Preferred types  
Standard current ratings (A)  
Interrupting capacity  
(UL 1077)  
6,000 A  
30 35 40 45 50 60 70 80 90  
Degree of protection  
(IEC 60529/DIN 40050)  
operating area IP40  
terminal area IP00  
x
x
x
x
x
413-K54-FN2-  
413-K14-LN2-  
x
x
x
x
x
x
x
x
x
Vibration  
10 g (56-500 Hz), 0.76 mm (10-55 Hz)  
to VG 95210, sheet 19,  
MIL-STD-202, meth. 204,  
IEC 60068-2-6, test Fc  
Standard current ratings and typical voltage drop values  
Current Voltage Current Voltage  
Shock  
50 g (11 ms)  
to VG 95210, sheet 28,  
MIL-STD-202, meth. 213,  
IEC 60068-2-27, test Ea  
rating (A) drop (mV)  
rating (A) drop (mV)  
-LN/N  
-FN  
-LN/N  
-FN  
Corrosion  
Humidity  
Mass  
96 hours at 5 % salt mist,  
to VG 95210, sheet 2,  
MIL-STD-202, meth. 101,  
IEC 60068-2-11, test Ka  
30  
35  
40  
45  
50  
≤ 250  
≤ 250  
≤ 200  
≤ 200  
≤ 200  
≤ 250  
≤ 250  
≤ 200  
≤ 200  
≤ 200  
55  
60  
70  
80  
90  
-
≤ 200  
≤ 200  
≤ 200  
≤ 200  
≤ 200  
-
-
-
-
240 hours at 95 % RH  
to VG 95210, sheet 7,  
MIL-STD-202, meth. 106,  
IEC 60068-2-3, test Ca  
approx. 65 g  
1646  
www.e-t-a.de  
1
High Performance Thermal Circuit Breaker 413-...  
Dimensions  
Internal connection diagram  
413-K14-...  
tightening torque max. 4 Nm  
ꢁꢂꢃꢄ 1  
M12x1  
ø10.6  
.417  
black  
white  
lock  
washer  
1
Typical time/current characteristics  
35  
°
23  
.906  
413-...-FN2 30...55 A  
1ꢚꢚꢚꢚ  
ꢏꢐꢑ ꢒꢓ  
ꢏ16ꢐ ꢒꢔ  
screw ISO1580-M6x8 (-N/-FN)  
M6x10 (-LN)  
lock washer DIN 137-B6  
tightening torque max. 2.5 Nm  
ꢏꢕꢖ ꢒꢓ  
ꢏꢐꢖꢗ4 ꢒꢔ  
1ꢚꢚꢚ  
1ꢚꢚ  
ꢘꢑꢑ ꢒꢓ  
ꢘ6ꢐ ꢒꢔ  
mounting holes  
413-K14-LN2  
min. ø3.2  
min .126  
current rating in A  
9.5  
.374  
1ꢚ  
1
SW14  
.551  
32  
location pin  
ꢚꢗ1  
1.26  
thickness 1.5 - 3 mm  
.059 - .118 in.  
ꢚꢗꢚ1  
ꢚꢗꢚꢚ1  
413-K54-...  
tightening torque max. 4 Nm  
M12x1  
ø10.6  
.417  
black  
1
4
6 ꢙ1ꢚ  
ꢕꢚ  
4ꢚ 6ꢚꢙꢚ1ꢚꢚ  
white  
ꢌ ꢄꢂꢅꢆꢈ ꢁꢍꢄꢆꢋ ꢉꢎꢁꢁꢆꢇꢄ  
lock  
washer  
413-...-LN2/-N2 30...90 A  
1ꢚꢚꢚꢚ  
ꢏꢐꢑ ꢒꢓ  
ꢏ16ꢐ ꢒꢔ  
ꢏꢕꢖ ꢒꢓ  
1ꢚꢚꢚ  
1ꢚꢚ  
ꢏꢐꢖꢗ4 ꢒꢔ  
ꢘꢑꢑ ꢒꢓ  
ꢘ6ꢐ ꢒꢔ  
1ꢚ  
1
35°  
23  
.906  
screw ISO1580-M6x8 (-N/-FN)  
M6x10 (-LN)  
lock washer DIN 137-B6  
tightening torque max. 2.5 Nm  
ꢚꢗ1  
413-K54-FN2/-N2  
ꢚꢗꢚ1  
ꢚꢗꢚꢚ1  
mounting holes  
current rating in A  
9.5  
.374  
1
4
6 ꢙ1ꢚ  
ꢕꢚ  
4ꢚ 6ꢚ1ꢚꢚ  
ꢌ ꢄꢂꢅꢆꢈ ꢁꢍꢄꢆꢋ ꢉꢎꢁꢁꢆꢇꢄ  
SW14  
.551  
32  
min. ø3.2  
min .126  
1.26  
location pin  
thickness 1.5 - 3 mm  
.059 - .118 in.  
mm  
inch  
This is a metric design and millimeter dimensions take precedence (  
)
2
www.e-t-a.de  
1646  
High Performance Thermal Circuit Breaker 413-...  
Accessories (approved to VG 95345, part 23)  
Accessories  
Splash cover /hex nut assembly with O ring ꢀꢁꢂ66 ꢌꢅꢎ ꢁꢂ6ꢘꢄ  
X 200 801 08 ꢅꢆꢇꢈꢉꢊ ꢋꢊꢌꢍꢉꢎ ꢅꢏꢍ ꢐ1ꢑꢒ1ꢙ ꢍꢚꢌꢅꢖꢋꢌꢚꢉꢅꢍ ꢇꢛꢜꢉꢚ  
X 200 801 03 ꢓꢌꢍꢍ ꢔꢊꢌꢇꢈ ꢕꢆꢅꢆꢖꢗ ꢅꢏꢍ ꢐ1ꢑꢒ1ꢙ ꢔꢊꢌꢇꢈ ꢇꢛꢜꢉꢚ  
Identification collar ꢀꢁ ꢂꢃ ꢄꢅꢆꢇꢇꢃꢈ ꢁꢅ ꢀꢉꢃ ꢇꢊꢄꢉ ꢂꢊꢀꢀꢁꢅ  
Y 307 004 01 black  
Y 307 004 02 white  
X 200 801 12 ꢝꢆꢍꢗ ꢔꢊꢌꢇꢈꢉꢅꢉꢎ ꢅꢏꢍ ꢌꢅꢎ ꢍꢚꢌꢅꢖꢋꢌꢚꢉꢅꢍ ꢇꢛꢜꢉꢚ  
Y 307 004 03 red  
Y 307 004 04 green  
Y 307 004 05 blue  
ꢒ14  
ꢑꢔꢔ1  
ꢒ6ꢑꢓꢔ  
ꢑꢕꢗꢘ  
ꢐ1ꢑꢒ1  
1
ꢒ1ꢕꢑꢖꢔ  
ꢑ4ꢓ6  
Splash cover black /hex nut assembly with O ring ꢀꢁꢂꢃ4ꢄ  
X 200 802 01 ꢅꢆꢇꢈꢉꢊ ꢋꢊꢌꢍꢉꢎ ꢅꢏꢍ ꢐ1ꢑꢒ1  
X 200 802 02 ꢓꢌꢍꢍ ꢔꢊꢌꢇꢈ ꢕꢆꢅꢆꢖꢗ ꢅꢏꢍ ꢐ1ꢑꢒ1  
ꢘꢑ6ꢔ  
ꢑꢘꢕ6  
ꢐ1ꢑꢒ1  
Lock out ring ꢀꢁ ꢂꢋꢁꢌꢍ ꢀꢉꢃ ꢇꢊꢄꢉ ꢂꢊꢀꢀꢁꢅ ꢎꢅ ꢏꢐꢐ ꢇꢁꢄꢎꢀꢎꢁꢅ  
Y 307 005 01 red  
Y 307 005 02 black  
ꢒ14ꢑ6  
ꢑꢔꢗꢔ  
Actuator extension ꢀꢔꢊꢌꢇꢈꢄ  
ꢍꢛ ꢔꢉ ꢕꢆꢍꢍꢉꢎ ꢛꢅ ꢍꢗꢉ ꢋꢏꢖꢗ ꢔꢏꢍꢍꢛꢅ  
X 200 803 01  
ꢞꢑꢟ  
ꢞꢠꢘꢡꢘ  
ꢒ1ꢘꢑꢙ  
ꢑ4ꢕꢙ  
ꢘꢑꢓ  
ꢑꢘꢖ1  
Approvals  
Authority  
UL  
Standard  
Rated voltage  
DC 28 V  
Current ratings  
30 A…90 A  
UL1077  
CSA  
C22.2 No  
235  
DC 28 V  
30 A…90 A  
QPL Sweden TL 5925-001 DC 28 V  
30 A…50 A  
Defence  
Material  
Admin.  
mm  
inch  
This is a metric design and millimeter dimensions take precedence (  
)
All dimensions without tolerances are for reference only. In the interest of improved design,  
performance and cost effectiveness the right to make changes in these specifications  
without notice is reserved.Product markings may not be exactly as the ordering codes.  
Errors and omissions excepted.  
1646  
www.e-t-a.de  
3
1
4
www.e-t-a.de  
1646  

相关型号:

413-K14-N2-30A

Extra low voltage wiring systems on all types of vehicles for land, sea and air; defence equipment; battery powered machines
ETAL

413-K14-N2-35A

Extra low voltage wiring systems on all types of vehicles for land, sea and air; defence equipment; battery powered machines
ETAL

413-K14-N2-40A

Extra low voltage wiring systems on all types of vehicles for land, sea and air; defence equipment; battery powered machines
ETAL

413-K14-N2-45A

Extra low voltage wiring systems on all types of vehicles for land, sea and air; defence equipment; battery powered machines
ETAL

413-K14-N2-50A

Extra low voltage wiring systems on all types of vehicles for land, sea and air; defence equipment; battery powered machines
ETAL

413-K14-N2-60A

Extra low voltage wiring systems on all types of vehicles for land, sea and air; defence equipment; battery powered machines
ETAL

413-K14-N2-90A

Extra low voltage wiring systems on all types of vehicles for land, sea and air; defence equipment; battery powered machines
ETAL

413-K54-FN2-30A

Extra low voltage wiring systems on all types of vehicles for land, sea and air; defence equipment; battery powered machines
ETAL

413-K54-FN2-35A

Extra low voltage wiring systems on all types of vehicles for land, sea and air; defence equipment; battery powered machines
ETAL

413-K54-FN2-40A

Extra low voltage wiring systems on all types of vehicles for land, sea and air; defence equipment; battery powered machines
ETAL

413-K54-FN2-45A

Extra low voltage wiring systems on all types of vehicles for land, sea and air; defence equipment; battery powered machines
ETAL

413-K54-FN2-50A

Extra low voltage wiring systems on all types of vehicles for land, sea and air; defence equipment; battery powered machines
ETAL