447-K-HFN-SI-FA24-250A [ETAL]

Heavy duty vehicles, battery systems, process control;
447-K-HFN-SI-FA24-250A
型号: 447-K-HFN-SI-FA24-250A
厂家: ETAL Group    ETAL Group
描述:

Heavy duty vehicles, battery systems, process control

文件: 总2页 (文件大小:174K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
High Performance Thermal-Magnetic Circuit Breakers 446/447/449  
Description  
Single pole thermal-magnetic circuit breakers with tease-free, trip-free,  
press-to-reset snap action mechanism and special dual button manual  
release which avoids the danger of unintended disconnection (M-type  
TM CBE to EN 60934). Surface mounted, compact design available  
with fast acting, standard and delayed switching characteristics.  
Options include auxiliary contact and remote electrical disconnection.  
Typical applications  
Heavy duty vehicles, battery systems, process control.  
1
446-...  
Technical data  
447-...  
449-...  
Ordering information  
Type No.  
446  
447  
449  
single pole base mounting, fast characteristic curve  
single pole base mounting, medium delay characteristic curve  
single pole base mounting, delayed characteristic curve  
Terminal design, mounting  
Voltage rating  
DC 28 V  
Current rating range  
type 446: 30...400 A  
type 447: 100...400 A  
type 449: 125...500 A  
K
screw terminals M12, insertion nuts M8  
Manual release  
H
standard  
Version  
Auxiliary circuit  
10 A  
N
general application (type 446 only)  
Electrical remote disconnection (-FA)  
FN general application (types 447 and 449 only)  
Auxiliary contacts (optional)  
Si 2 electrically separate auxiliary contacts  
with screw terminals M3.5 and  
blade terminals DIN 46244-C-MS-S  
Remote trip (optional for types 447 and 449)  
FA24 DC 24 V coil voltage  
Current ratings  
operating voltage  
operating current  
max. pulse time  
switching time  
DC 12 V or DC 24 V  
approx. 18 A or 12 A  
10 ms < tON < 20 ms / tOFF > 10 s  
< 20 ms  
Typical life  
1,000 operations at IN  
2,000 operations mechanical  
Ambient temperature  
-55...+75 °C (-67...+167 °F)  
30...400 A type 446  
100...400 A type 447  
125...500 A type 449  
Insulation co-ordination  
(IEC 60664 and 60664A) withstand voltage  
1.5 kV  
rated impulse  
pollution  
degree  
3
Dielectric strength  
(IEC 60664 and 60664A) test voltage  
operating area  
main circuit to  
auxiliary contacts  
447 - K - H - FN - ... - ... - 400 A  
ordering example  
The exact part number required can be built up from the table of choices  
shown above. Ordering references for optional features should be omitted if not  
required.  
AC 1,500 V  
AC 1,500 V  
Insulation resistance  
> 100 MΩ (DC 500 V)  
10,000 A  
Interrupting capacity Icn  
Standard current ratings and typical internal resistance values  
Degree of protection  
(IEC 60529/DIN 40050)  
operating area IP40  
terminal area IP00  
Internal  
Internal  
Current  
Current  
ratings (A)  
ratings (A)  
resistance (Ω)  
resistance (Ω)  
Vibration  
to VG 95210, sheet 19,  
IEC 60068-2-6, test Fc:  
Type 446:  
30  
Type 447:  
100  
without aux. contacts: 10 g (56-500 Hz), 0.76 mm (10-55 Hz)  
with auxiliary contacts: 4 g (56-500 Hz), 0.30 mm (10-56 Hz)  
0.006  
< 0.002  
< 0.001  
< 0.001  
< 0.001  
< 0.001  
< 0.001  
40  
0.0048  
0.0038  
0.0028  
0.0025  
0.0023  
0.0019  
0.0016  
< 0.001  
< 0.001  
< 0.001  
< 0.001  
< 0.001  
125  
Shock  
to VG 95210, sheet 28,  
IEC 60068-2-27, test Ea:  
50  
160  
without aux. contacts: 50 g (11 ms)  
with auxiliary contacts: 20 g (11 ms)  
60  
225  
70  
300  
Corrosion  
Humidity  
Mass  
96 hours at 5 % salt mist  
to VG 95210, sheet 2,  
IEC 60068-2-11, test Ka  
80  
400  
90  
Type 449:  
125  
100  
125  
150  
170  
200  
225  
< 0.001  
< 0.001  
< 0.001  
< 0.001  
< 0.001  
< 0.001  
< 0.001  
240 hours at 95 % RH  
to VG 95210, sheet 7,  
IEC 60068-2-3, test C  
160  
225  
approx. 850 g  
315  
350  
Approvals  
400  
250  
300  
350  
400  
< 0.001  
< 0.001  
< 0.001  
< 0.001  
500  
Authority  
Standard  
Rated voltage Current ratings  
only with 50 % ON duty  
UL  
CSA C22.2 No 235  
UL UL 1077  
CSA C22.2 No 235  
Bw 95345, part 15  
UL 1077  
DC 28 V  
DC 28 V  
DC 28 V  
DC 28 V  
up to 400 A  
up to 400 A  
100...350 A  
100…350 A  
Type 446/  
Type 447  
Type 449:  
All dimensions without tolerances are for reference only. In the interest of improved design,  
performance and cost effectiveness the right to make changes in these specifications  
without notice is reserved.Product markings may not be exactly as the ordering codes.  
Errors and omissions excepted.  
DC 28 V  
125...500 A  
1646  
www.e-t-a.de  
1
High Performance Thermal-Magnetic Circuit Breakers 446/447/449  
Dimensions  
Internal connection diagrams  
ꢉꢁ  
ꢀꢁꢂꢃ 1  
ꢀꢁꢂꢃ 1  
4
6
60  
2.36  
ꢍꢃꢎꢏꢐꢐꢃꢂꢑꢃꢑ  
ꢀꢁꢂꢒ ꢓꢏꢍ ꢊꢋ ꢎꢏꢁꢀ  
ꢔꢍꢏꢕꢃꢎꢕꢁꢏꢂ  
hex nut M8 or 5/16"-18-NC  
ø26  
14 mm/.551 in. usable thread length  
tightening torque max. 3.5 Nm  
1.02  
ꢊꢋ  
ø20  
.787  
1
FA-terminal (8)  
Typical time/current characteristics at +23 °C/+73.4 °F  
hex nut  
N/C 4/5  
N/O 6/7  
ISO 4032-M12-Cu2-E1P  
tightening torque  
max. 10 Nm  
106  
4.17  
446-...  
DC  
lock washer  
DIN 137-B12-  
X12CrNi 177  
1ꢂꢂꢂꢂ  
35  
1.38  
1ꢂꢂꢂ  
1ꢂꢂ  
hex screw  
ISO 4017-M12x30-Cu2-E1P  
100  
3.94  
170  
6.69  
140  
5.51  
current rating in A  
1ꢂ  
1
EIN ON  
AUS OFF  
AUS OFF  
43.5  
12  
11  
ꢂꢏ1  
.433  
1.71  
.472  
blade terminal DIN 46244-C-MS-S  
ꢂꢏꢂ1  
ꢂꢏꢂꢂ1  
flat head screw ISO 1580-M3.5x5  
tightening torque max. 0.55 Nm  
1
4
6
1ꢂ  
ꢀꢂ  
4ꢂ 6ꢂ 1ꢂꢂ  
ꢃ ꢄꢅꢆꢇꢈ ꢉꢊꢄꢇꢋ ꢌꢍꢉꢉꢇꢎꢄ  
mm  
inch  
This is a metric design and millimeter dimensions take precedence (  
)
Typical time/current characteristics  
ꢀꢀꢁꢂꢃ  
1ꢚꢚꢚꢚ  
ꢄꢅ  
ꢀꢀꢆꢂꢃ 1ꢇꢈꢃꢀꢉꢉ ꢊ  
1ꢚꢚꢚꢚ  
ꢄꢅ  
ꢀꢀꢆꢂꢃ ꢈꢉꢉ ꢛꢍꢚꢜ ꢝꢞ ꢈꢊꢁꢟꢠ6ꢚ ꢃꢂꢋꢡ ꢄꢅ  
1ꢚꢚꢚꢚ  
1ꢚꢚꢚ  
1ꢚꢚ  
1ꢚꢚꢚ  
1ꢚꢚ  
1ꢚ  
1ꢚꢚꢚ  
1ꢚꢚ  
1ꢚ  
1ꢚ  
1
1
1
ꢚꢕ1  
ꢚꢕꢚ1  
ꢚꢕ1  
ꢚꢕꢚ1  
ꢚꢕ1  
ꢚꢕꢚ1  
ꢚꢕꢚꢚ1  
ꢚꢕꢚꢚ1  
ꢚꢕꢚꢚ1  
1
4
6
1ꢚ  
ꢓꢚ  
4ꢚ 6ꢚ 1ꢚꢚ  
1
4
6
1ꢚ  
ꢓꢚ  
4ꢚ 6ꢚ 1ꢚꢚ  
1
4
6
1ꢚ  
ꢓꢚ  
4ꢚ 6ꢚ 1ꢚꢚ  
ꢀ ꢁꢂꢃꢄꢅ ꢆꢇꢁꢄꢈ ꢉꢊꢆꢆꢄꢋꢁ  
ꢀ ꢁꢂꢃꢄꢅ ꢆꢇꢁꢄꢈ ꢉꢊꢆꢆꢄꢋꢁ  
ꢀ ꢁꢂꢃꢄꢅ ꢆꢇꢁꢄꢈ ꢉꢊꢆꢆꢄꢋꢁ  
ꢌꢍꢍ ꢎꢏ  
ꢌ6ꢐ ꢎꢑ  
ꢒꢓꢔ ꢎꢏ  
ꢒꢐꢔꢕ4 ꢎꢑ  
ꢒꢐꢍ ꢎꢏ  
ꢒ16ꢐ ꢎꢑ  
ꢏꢂꢆꢉꢊꢂꢁ ꢢꢆꢄꢇꢣꢄꢆꢅ ꢤꢂꢁꢥ ꢆꢄꢃꢘꢁꢄ ꢈꢂꢅꢉꢘꢋꢋꢄꢉꢁꢂꢘꢋ ꢦꢇꢉꢂꢧꢂꢁꢟ ꢤꢂꢧꢧ ꢁꢆꢂꢗ 1ꢚꢜ ꢦꢇꢅꢁꢄꢆ  
2
www.e-t-a.de  
1646  

相关型号:

447-K-HFN-SI-FA24-300A

Heavy duty vehicles, battery systems, process control
ETAL

447-K-HFN-SI-FA24-400A

Heavy duty vehicles, battery systems, process control
ETAL

4470-01FB

General Purpose Inductor, 1uH, 1%, 1 Element, Iron-Core,
API

4470-01H

General Purpose Inductor, 1uH, 3%, 1 Element, Iron-Core, AXIAL LEADED
API

4470-01HB

General Purpose Inductor, 1uH, 3%, 1 Element, Iron-Core,
API

4470-01JB

General Purpose Inductor, 1uH, 5%, 1 Element, Iron-Core,
API

4470-01K

Molded Unshielded RF Coils
API

4470-01KB

General Purpose Inductor, 1uH, 10%, 1 Element, Iron-Core,
API

4470-02F

General Purpose Inductor, 1.2uH, 1%, 1 Element, Iron-Core, AXIAL LEADED
API

4470-02FB

General Purpose Inductor, 1.2uH, 1%, 1 Element, Iron-Core,
API

4470-02G

General Purpose Inductor, 1.2uH, 2%, 1 Element, Iron-Core, AXIAL LEADED
API

4470-02GB

General Purpose Inductor, 1.2uH, 2%, 1 Element, Iron-Core,
API