520-K-1-05-SI-10A [ETAL]
Motors, generators, transformers, thyristors and silicon rectifiers;型号: | 520-K-1-05-SI-10A |
厂家: | ETAL Group |
描述: | Motors, generators, transformers, thyristors and silicon rectifiers |
文件: | 总4页 (文件大小:318K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
High Performance Thermal-Magnetic Circuit Breakers 410/520/530-...
Description
Single, double and three pole high performance thermal-magnetic
circuit breakers with tease-free, trip-free, snap action mechanism and
toggle actuation (S-type TM CBE to EN 60 934; also to EN 60 947).
Designed for rail, panel or surface mounting. Available with a choice
of characteristic curves and optional auxiliary contacts.
Typical applications
Motors, generators, transformers, thyristors and silicon rectifiers.
1
Interrupting capacity to IEC 60947/EN 60947
410-...
530-...
AC voltage
Number
of poles
Voltage
rating
Interrupting
Power
factor
Interrupting
Power factor
Technical data
capacity I
capacity I
N
N
I
I
N 12...125 A
N 7 + 10 A
Voltage rating
AC 240 V; 3 AC 415 V; 3 AC 500 V
DC 110 V
1
2
3
AC 240 V
AC 240 V
3 AC 415 V
5,000 A
8,000 A
5,000 A
cosϕ = 0.7
cosϕ = 0.7
cosϕ = 0.7
3,500 A
6,000 A
3,000 A
cosϕ = 0.8
cosϕ = 0.7
cosϕ = 0.85
Current rating range
curves 01, 02, 04, 05:
curves B3, C3, 01:
10...125 A (EN 60947)
7...100 A (EN 60898)
DC voltage
Auxiliary circuit
6 A, AC 240 V or DC 28 V
1 A, DC 110 V
Number
of poles
Voltage
rating
Interrupting
capacity I
Time
constant
Interrupting
capacity I
Time con-
stant
N
N
Typical life
10,000 operations at 1 x IN
20,000 operations mechanical
I
I
N 12...125 A
N 7 + 10 A
1
1
2
2
DC 110 V
DC 110 V
DC 110 V
DC 110 V
3,000 A
5,000 A
5,000 A
10,000 A
13 ms
5 ms
3,000 A
3,000 A
L/R = 5 ms
L/R = 5 ms
Ambient temperature
-40...+60 °C (-40...+140 °F)
Insulation co-ordination
(IEC 60664 and 60664A)
rated impulse
withstand voltage
6 kV
pollution
degree
3
13 ms
≈ 0 ms
Dielectric strength
(IEC 60664 and 60664A)
operating area
pole/pole
main circuit/aux.circuit
aux. circuit 11-12/13-14
test voltage
AC 3,300 V
AC 3,300 V
AC 2,200 V
AC 1,000 V
Standard current ratings and typical internal resistance values
Curves 01, 02, 04, 05:
Curves B3, C3:
Insulation resistance
> 100 MΩ (DC 500 V)
Degree ef protection
(IEC 60529/DIN 40050)
operating area IP40
terminal area IP00
Current
Internal resistance Current Internal resistance
rating (A) (Ω) per pole
rating (A) (Ω) per pole
Vibration
10
16
20
25
32
40
50
63
80
90
100
125
0.033
7
0.033
curves 02, 04, 05, B3, C3: 4 g (60-500 Hz), 0.30 mm (10-60 Hz)
curve 01:
0.015
10
12
16
20
25
32
40
50
63
80
100
0.015
3 g (60-500 Hz), 0.23 mm (10-60 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
0.010
0.015
0.0062
0.0039
0.0031
0.0022
≤ 0.002
≤ 0.002
≤ 0.002
≤ 0.002
≤ 0.002
0.010
Shock
curves 02, 04, 05, B3, C3: 50 g (11 ms) directions 1, 2, 3, 4, 5
30 g in direction 6
curve 01:
0.0062
0.0039
0.0031
0.0022
≤ 0.002
≤ 0.002
≤ 0.002
≤ 0.002
30 g (11 ms) in directions 1, 2, 3, 4, 5
20 g in direction 6
to IEC 60068-27, test Ea
Corrosion
Humidity
Mass
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH
to IEC 60068-2-3, test Ca
410 (1-pole): approx. 290 g
520 (2-pole): approx. 580 g
530 (3-pole): approx. 870 g
Approvals
Authority
Standard
Rated voltage Current ratings
AC 277 V 7...125 A (type 520)
UL
UL 1077
C22.2 No 235
1646
www.e-t-a.de
1
High Performance Thermal-Magnetic Circuit Breakers 410/520/530-...
Ordering information
Dimensions
Type No.
410
520
530
single pole (ratings > 125 A: suffix 17015 - parallel connection)
double pole
three pole
Terminal design - main terminals
26
26°
°
ON
OFF
K
screw terminals
10-32 A pressure plate B5-DIN 46288 (curves B3/C3, 7-25 A)
40-63 A pressure plate B6-DIN 46288 (curves B3/C3, 32-63 A)
80-125 A terminal screw DIN 46206, sheet 2, form 1, M6 thread
Mounting
Si terminals M3.5
1 N/C
1 N/O
1
2
4
surface mounting
rail mounting (DIN EN 50022-35x7.5) or panel mounting
panel mounting with cylinder head screw M3.5
Magnetic trip curves
1
01 2.1-3 x IN AC (thyristor and rectifier protection)
02 7-10 x IN AC (motor and generator protection to EN 60947)
04 3.5-5 x IN AC (cable protection to EN 60947)
05 4-6 x IN AC (generator protection to EN 60947)
B3 3-5 x IN AC (cable protection to EN 60898)
C3 5-10 x IN AC (cable protection to EN 60898)
Auxiliary contacts optional (terminals M3.5)
92
3.62
16
.630
symmetrical rail DIN EN 50022-35x7.5
G profile rail DIN EN 50035-G32 (not shown)
M3.5 - thread max. 9 mm (.354 in.) deep
tightening torque max. 0.8 N
D
Si
one each N/O and N/C contact
45
1.77
35
Si1 one N/C (11,12)
Current ratings
7...125 A
E
1.38
520 - K - 1 - 01 - ... - 10 A
ordering example
pole 1
The exact number required can be built up from the table of choices shown above.
Ordering references for optional features should be omitted if not required.
pole 2
B
pole 3
Mounting methods
Surface mounting
-1
rail mounting
(DIN EN 50 022-35x7,5)
-2
Current Dimensions mm/in.
rating
Terminal
Cross section (see DIN 46288)
ꢇꢈꢉꢁ
tightening
torque
with 1 or 2 equal
conductors
with 2 different
conductors
B
C
D
E
pressure
plate B5
DIN 46288
2.5 mm2 to
10 mm2
1ꢀ 114
ꢆ
2.5 mm2 to
10 mm2
2.0 Nm
≤ 32 A
M5
ꢁꢂ1ꢃ 4ꢁ4ꢅ ꢁꢃꢆ6
4 mm2 and 6 mm2
or
pressure
plate B6
4 mm2 to
16 mm2
1ꢂꢁ4 1ꢃꢄ
ꢅ
2.5 Nm
2.5 Nm
≤ 63 A
M6
M6
ꢁ6ꢄ6 4ꢁꢆꢃ ꢁꢀꢂ4
6 mm2 to 16 mm2
DIN 46288
terminal
screw
1ꢂꢁ4 1ꢃꢄ
ꢁ6ꢄ6 4ꢁꢆꢃ ꢁꢀꢂ4
ꢅ
panel mounting
-4
≤ 125 A
surface mounting
14.6
.575
monting holes
35
1.38
ø20
.787
3.7
.146
22
.866
ø4.6
.181
mm
inch
This is a metric design and millimeter dimensions take precedence (
)
2
www.e-t-a.de
1646
High Performance Thermal-Magnetic Circuit Breakers 410/520/530-...
Typical time/current characteristics at +23 °C/+73.4 °F
Internal connection diagrams
Type 410-K
Type 410-K-Si
Magnetic trip curves 01,02,04,05
AC/DC
1)
line 1
line 1
11
12
13
14
1ꢑꢑꢑꢑ
1ꢑꢑꢑ
>
>
I
I
1ꢑꢑ
2
2
1ꢑ
1
1
Type 530-K-Si
Type 520-K-Si
line 1
3
11
12
13
14
ꢑꢓ
line 1
3
5
11
13
14
ꢑ1 ꢑ4 ꢑꢏ
ꢑꢒ1
ꢑꢒꢑ1
ꢑꢒꢑꢑ1
12
>
>
I
I
>
>
>
I
I
I
1
ꢏ
4
6
ꢐ
1ꢑ
ꢏꢑ
4ꢑ 6ꢑ ꢐꢑ1ꢑꢑ
2
4
6
2
4
ꢀ ꢁꢂꢃꢄꢅ ꢆꢇꢁꢄꢈ ꢉꢊꢆꢆꢄꢋꢁ
Magnetic trip curves B3,C3
Shock directions
1)
AC/DC
1ꢑꢑꢑꢑ
4
1ꢑꢑꢑ
1ꢑꢑ
ꢁ
ꢀ
1ꢑ
1
1
ꢂ
6
ꢔꢕ ꢖꢕ
ꢑꢒ1
ꢑꢒꢑ1
ꢑꢒꢑꢑ1
1
ꢏ
4
6
ꢐ
1ꢑ
ꢏꢑ
4ꢑ 6ꢑ ꢐꢑ1ꢑꢑ
ꢀ ꢁꢂꢃꢄꢅ ꢆꢇꢁꢄꢈ ꢉꢊꢆꢆꢄꢋꢁ
1)
Magnetic tripping currents are increased by 20% on DC
supplies.
1646
www.e-t-a.de
3
High Performance Thermal-Magnetic Circuit Breakers 410/520/530-...
Accessories
Terminal insulation cover for 410/520/530-...
X 211 705 01
ꢠ1 ꢐꢉꢈ ꢡ ꢄ ꢅꢊꢐ ꢅꢉꢆ ꢅꢇꢢꢉꢣ
Splash cover (transparent),
with fixing plate and screws (IP54)
for type 410
X 211 118 01
ꢅꢆꢇꢈꢉꢊꢈꢉꢋ ꢌꢍꢌꢎꢏꢐꢈ ꢑꢆꢒꢐꢓ ꢊꢇꢏꢈꢌꢊꢈ ꢔ
53
2.09
40
1.57
38
1.50
1
24.5
.965
ꢀꢁꢂꢃꢄꢅꢃꢄꢆ ꢇꢈꢇꢉꢊꢋꢃ ꢌꢁꢍꢋꢎ ꢅꢂꢊꢃꢇꢅꢃ ꢏ
mounting hole
25+0.3
.984+.012
16ꢀ
6ꢝꢀꢂ
ꢔ ꢈꢇ ꢕꢖꢗ ꢀꢘ1ꢂ6ꢙ1ꢂꢂꢚꢛꢕꢜ ꢂ1ꢂ6 ꢙ1ꢂꢂ
35
1.38
Splash cover (transparent),
with fixing plate and screws (IP54)
for type 520
X 211 119 01
53
2.09
38
1.50
24.5
59
.965
2.32
mounting hole
25+0.3
.984+.012
35
1.38
mm
inch
This is a metric design and millimeter dimensions take precedence (
)
All dimensions without tolerances are for reference only. In the interest of improved design,
performance and cost effectiveness the right to make changes in these specifications
without notice is reserved.Product markings may not be exactly as the ordering codes.
Errors and omissions excepted.
4
www.e-t-a.de
1646
相关型号:
©2020 ICPDF网 联系我们和版权申明