9510-G113-J3F0-B [ETAL]

Utility vehicles for hazardous goods;
9510-G113-J3F0-B
型号: 9510-G113-J3F0-B
厂家: ETAL Group    ETAL Group
描述:

Utility vehicles for hazardous goods

文件: 总6页 (文件大小:733K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Battery Master Switch BMS01  
Description  
The BMS01 is a battery master switch designed for dangerous goods road  
vehicles complying with international ADR regulations. Environmental  
protection and the intrinsically safe control circuitry of the BMS01 are  
in accordance with ADR 2015. The battery switch must be installed  
between the battery and the vehicle’s electrical system. It is operated  
on and off by means of a control switch in the driver’s cab, additional  
control switches can be sited around the vehicle as required. The  
BMS01 is a double pole device, but can be connected as 1-pole  
version (see connection diagram).  
An integral safety barrier permits siting of the BMS01 in hazardous  
areas. Additional auxiliary contacts are provided for disconnection of  
the ignition circuit, de-energisation of the alternator field winding, or a  
controlled shutdown of the CANBUS system followed after a delay by  
disconnection of the battery.  
BMS01  
Typical applications  
Technical data  
Utility vehicles for hazardous goods.  
Operating data  
Voltage rating  
2
DC 12 V  
DC 24 V  
18...32 V  
Voltage range  
9...16 V  
Ordering information  
Rated current  
200 A / pole  
Type number  
BMS01 Battery Master Switch (to ADR 2015)  
Number of poles  
Max. overload current  
2,400 A 1 s; 600 A 20 s  
Power consumption of  
electronic module  
2
2-pole  
Rated voltage  
typically 5 mA (in OFF condition)  
Excitation current / time of  
the bistable main relay  
0
1
DC 12 V  
DC 24 V  
Control function: delay time between  
auxiliary contact K13 and main contacts  
12 V:  
24 V:  
typically 2.6 A / 200 ms  
typically 1.3 A / 200 ms  
1
2
5
1 sec / ADR-compliant  
9.5 sec / ADR-compliant  
180 sec / version for SCRT (BlueTec) motors  
Control circuit (EX)  
Temperature range  
ZELM 04 ATEX 0213X  
Ex II (2) G [Ex ib] II C  
Control function: low voltage monitoring  
-40...+70 °C (-40...+158 °F)  
0
1
without low voltage monitoring  
Reverse polarity protection integral (in the event of reverse polarity  
the master switch will disconnect  
with low voltage monitoring and disconnection -  
device switches off in undervoltage condition  
with low voltage monitoring and signalisation  
Version  
3
instantaneously)  
Low voltage monitoring  
switching thresholds:  
hysteresis:  
DC 12 V  
DC 24 V  
0
neutral  
11.0 V 0. 3 V 22.8 V 0.3 V  
typically 0.25 V typically 0.5 V  
typically 60 sec typically 60 sec  
BMS01 -  
2
1
1
1 -  
0
ordering example  
trip time:  
Typical life  
10,000 cycles at rated current  
100,000 cycles without load  
Rubber caps and mounting screws are supplied with the product.  
Accessories (e.g. external control switch, 7-pole and 4-pole connectors) should be  
ordered separately.  
Protection class: housing  
Protection class: terminals  
IP65  
IP54 with rubber caps  
Vibration  
5 g (57-200 Hz), 0.38 mm (10-57 Hz),  
test to IEC 60068-2-6, test Fc,  
10 frequency cycles / axis  
Approvals  
Authority Standard  
Rated voltage  
Shock  
10 g, test to IEC 60068-2-27, test Ea  
Corrosion  
96 hrs 5 % salt mist,  
test to IEC 60068-2-11, test Ka  
TÜV  
- ADR 2015 Teil/part 9, 9.2.2 und /  
and 9.7.8  
- VdTÜV-Merkblatt 5205, Ausgabe /  
edition 03.2015  
- IEC 60079-0:2011  
- IEC 60079-11:2011  
- IEC 60529:2001  
Humidity  
240 hrs. 95 % RH,  
test to IEC 60068-2-78, test Cab  
Terminals  
battery terminals:  
control terminals:  
M10 terminal studs  
AUX connectors to DIN 72 585, 7-pole  
CRTL connectors to DIN 72 585, 2-pole  
KBA  
ECE Regelung Nr. 10 (E1) Rev. 4  
DC 12 V  
DC 24 V  
Auxiliary contact  
max. 10 A (circuit unprotected)  
ZELM  
EN60079-0:2012+A11:2013  
EN60079-11:2012  
DC 12 V  
DC 24 V  
Aux. energy output for  
permanently energised loads  
(e.g. tachograph)  
max. 1 A (internally protected)  
approx. 1,700 g  
Mass  
Protection Class  
IP65  
1615  
www.e-t-a.de  
1
Battery Master Switch BMS01  
Signalisation by bicoloured LED  
Signalisation by bicoloured LED  
via control switch  
red and green LED  
- Main contact closed “ON“  
- Main contact open “OFF“  
Low voltage detected  
status LED flashes green (100 ms on; 900 ms off)  
status LED flashes red (100 ms on; 900 ms off)  
- Main contact closed  
status LED flashes green / red (900 ms green; 100 ms red)  
status LED red permanently on  
- Main contact open due to low voltage  
Main contact monitoring  
- Main contact does not follow control switch  
“error”  
status LED flashes red / green (500 ms red; 500 ms green)  
Dimensions  
ꢅꢏꢤꢑꢅꢆꢐꢏꢐꢤ ꢅꢄꢖꢧꢙꢆ ꢘꢒꢡꢂ 1ꢁ ꢃꢘ  
2
ꢣ ꢖꢙꢓꢓꢆꢖ ꢔꢒꢠꢇ ꢢꢇꢙꢠꢠꢞꢏꢆꢕ ꢦꢏꢅꢑ ꢠꢖꢄꢕꢙꢔꢅꢉ  
ꢀ 1ꢁ  
ꢝꢆꢘꢒꢞꢆ ꢔꢄꢐꢐꢆꢔꢅꢄꢖ  
ꢢꢐꢄꢅ ꢇꢙꢠꢠꢞꢏꢆꢕ  
ꢦꢏꢅꢑ ꢠꢖꢄꢕꢙꢔꢅꢉ  
ꢇꢐꢒꢠꢨꢄꢐ ꢔꢄꢜꢆꢖ  
1ꢀꢁ  
ꢫꢂ16  
5
ꢘꢄꢙꢐꢅꢏꢐꢤ ꢑꢄꢞꢆꢇ  
ꢁꢆꢆ  
ꢫꢂꢪꢫ  
61ꢂ6  
ꢚꢂꢣꢚ  
ꢯ ꢪꢂꢪ ꢘꢒꢡꢂ  
ꢯ ꢂꢥꢣ6 ꢘꢒꢡꢂ  
ꢫꢨꢠꢄꢞꢆ  
ꢔꢄꢐꢐꢆꢔꢅꢄꢖ  
ꢒꢙꢡꢏꢞꢏꢒꢖꢗ  
ꢔꢗꢞꢏꢐꢕꢆꢖ ꢑꢆꢒꢕ ꢇꢔꢖꢆꢦ  
ꢅꢄ ꢬꢭꢃ ꢫꢚ5ꢪ5  
ꢀ5 ꢬꢭꢃ ꢩ1ꢚ ꢰ ꢭꢱꢛ ꢣꢫ6ꢚ  
ꢅꢏꢤꢑꢅꢆꢐꢏꢐꢤ ꢅꢄꢖꢧꢙꢆ ꢘꢒꢡꢂ ꢥ ꢃꢘ  
ꢇꢙꢠꢠꢞꢏꢆꢕ ꢦꢏꢅꢑ ꢠꢖꢄꢕꢙꢔꢅ  
AUX  
BATT – LOAD –  
BMS01  
ꢓꢏꢔꢄꢞꢄꢙꢖꢆꢕ  
ꢇꢅꢒꢅꢙꢇ ꢍꢮꢬ  
Status  
ꢲꢮꢌꢀꢳꢃꢴ  
CTRL  
Ex ib  
BATT + LOAD +  
ꢣꢨꢠꢄꢞꢆ  
ꢔꢄꢐꢐꢆꢔꢅꢄꢖ  
ꢔꢄꢐꢅꢖꢄꢞ  
ꢅꢄ ꢬꢭꢃ ꢫꢚ5ꢪ5  
T
= 10 Nm  
max  
ꢀ5  
ꢀ 1ꢁ  
ꢃꢄꢅꢆꢇꢈ  
1ꢉ ꢊꢋꢌꢍ ꢎꢏꢐ 1 ꢑꢒꢇ ꢅꢄ ꢓꢆ ꢔꢄꢐꢐꢆꢔꢅꢆꢕ ꢅꢄ ꢓꢒꢅꢅꢆꢖꢗ ꢘꢏꢐꢙꢇꢂ  
ꢚꢉ ꢛꢓꢇꢆꢖꢜꢆ ꢏꢐꢇꢅꢖꢙꢔꢅꢏꢄꢐꢇ ꢝꢄꢖ ꢏꢐꢇꢅꢒꢞꢞꢒꢅꢏꢄꢐꢟꢂ  
mm  
inch  
This is a metric design and millimeter dimensions take precedence (  
)
2
www.e-t-a.de  
1615  
Battery Master Switch BMS01  
Connection diagram 1-pole  
Terminal design  
D+  
15  
A
B
87a  
ꢃꢌꢕꢁꢅꢋꢓꢌꢖꢁ  
86  
85  
31  
87  
AUX  
BMS01  
31a  
1
2
3
ꢀꢁꢂꢃꢄꢅꢆꢇ  
ꢈ1ꢉ  
31a  
30a  
31a  
ꢕꢅꢇꢃꢓꢅꢍ  
4
- Batt  
+ Batt  
- Load  
+ Load  
5
6
A
B
ꢀꢊꢋꢇꢌꢍ  
7
ꢈ1ꢎ  
30a  
CTRL  
1
2
ꢏꢐꢑꢒꢌꢓꢓꢊꢔꢓ  
ꢗꢘꢙ ꢀꢆꢊꢃꢕꢁ  
ꢚꢂꢃꢀꢊꢄꢔ  
30  
31  
+
ꢗꢘꢙ ꢀꢆꢊꢃꢕꢁ  
ꢛꢇꢀꢊꢄꢔ  
cable lug  
2
Note: ꢝꢓꢅꢂꢇꢄ ꢃꢔꢓꢞꢊꢇꢌꢍ ꢁꢌꢀ ꢃꢅ ꢒꢔ ꢕꢅꢇꢇꢔꢕꢃꢔꢄ ꢟꢊꢌ ꢑꢠꢌꢃꢃꢡ  
Connection diagram 2-pole  
D+  
15  
87a  
ꢃꢌꢕꢁꢅꢋꢓꢌꢖꢁ  
86  
31  
87  
85  
AUX  
BMS01  
31a  
1
2
3
ꢀꢁꢂꢃꢄꢅꢆꢇ  
ꢈ1ꢉ  
31a  
30a  
31a  
30a  
31a  
ꢕꢅꢇꢃꢓꢅꢍ  
4
- Batt  
+ Batt  
- Load  
+ Load  
5
6
ꢀꢊꢋꢇꢌꢍ  
7
ꢈ1ꢎ  
CTRL  
1
2
ꢏꢐꢑꢒꢌꢓꢓꢊꢔꢓ  
ꢗꢘꢙ ꢀꢆꢊꢃꢕꢁ  
ꢚꢂꢃꢀꢊꢄꢔ  
IP54  
30  
31  
+
ꢗꢘꢙ ꢀꢆꢊꢃꢕꢁ  
ꢛꢇꢀꢊꢄꢔ  
cable binder  
Pin Assignment  
CTRL  
1 and 2 to switch the battery isolation switch ON and OFF by  
means of a control switch in the driver´s cab and one  
or more control switches outside the vehicle (if required)  
AUX  
mm  
inch  
This is a metric design and millimeter dimensions take precedence (  
)
1 and 2 current-limited supply line for permanently  
energised loads, e. g. tachograph, limited to 1 A  
Note: the rubber caps can be cut to match the outer diameter of the  
connected cable.  
3 and 4 shutdown contact, which opens immediately after the  
control switch has been operated and remains open until  
the battery is disconnected  
Rubber caps  
5
to de-activate low voltage disconnection when driving;  
only for configuration “1” for “Control function: low  
voltage monitoring”  
Outer cable dia.  
(mm)  
Inner dia. of rubber Cutting position  
caps (mm)  
6 and 7 signal contact, closes during the response delay and may  
be used for an acoustic alarm signal during the period  
until final disconnection of the battery  
14 - 17  
13  
16  
21  
-
> 17 - 22  
> 22 - 25.4  
A - A  
B - B  
1615  
www.e-t-a.de  
3
Battery Master Switch BMS01  
Functional diagrams  
Diagram 1  
Type: BMS01-2120  
switch on/off via control switch  
control switch emergency  
ON  
stop  
OFF  
ON  
OFF  
battery isolation switch  
K13 aux. contact  
K14 aux. contact  
tV  
tN  
active  
passive  
9.5 s  
active  
tN  
10 s  
passive  
2
Diagram 2  
Type: BMS01-2121  
with low voltage monitoring and automatic disconnection  
control switch emergency  
stop  
ON  
OFF  
ON  
OFF  
battery isolation switch  
control input pin 5  
voltage monitoring  
K13 aux. contact  
Plus  
Minus  
U > 23.3 V  
U < 22.8 V  
tN  
60 s  
tV  
9.5 s  
tN  
active  
passive  
K14 aux. contact  
active  
passive  
Diagram 3  
Type: BMS01-2123  
with low voltage monitoring and signalisation via K14  
and ON/OFF operation via control switch  
ON  
control switch emergency  
stop  
OFF  
ON  
battery isolation switch  
OFF  
active  
tV  
9.5 s  
tN  
10 s  
K13 aux. contact  
control input pin 5  
passive  
Plus  
Minus  
U > 23.3 V  
U < 22.8 V  
voltage monitoring  
K14 aux. contact  
active  
passive  
4
www.e-t-a.de  
1615  
Battery Master Switch BMS01  
Mounting holes 
Accessories  
External Control Switch  
XSB-A-...  
6ꢀ  
ꢁꢂꢃ6  
For more info please enquire  
for a separate data sheet  
2
1615  
www.e-t-a.de  
5
Battery Master Switch BMS01  
Accessories  
Connector sleeve ꢀꢁꢂꢃ ꢄꢅ ꢆꢇꢈ ꢉꢅꢊꢂꢋꢌ ꢍꢂꢇꢇꢌꢍꢎꢂꢃꢏꢐ  
4-pole connector CTRL  
X 222 581 01  
Y 307 978 01 ꢀꢑꢒ1ꢓꢐ  
Y 307 977 01 ꢀꢑꢒ1ꢓꢐ  
Y 307 979 01 ꢀꢈꢔ11 ꢕꢕꢐ  
female connector  
crimp contact  
blanking  
plug  
seal  
lock  
7-pole connector AUX  
X 222 580 01  
2
female connector  
crimp contact  
seal  
lock  
All dimensions without tolerances are for reference only. In the interest of improved design,  
performance and cost effectiveness the right to make changes in these specifications without  
notice is reserved. Product markings may not be exactly as the ordering codes. Errors and  
omissions excepted.  
6
www.e-t-a.de  
1615  

相关型号:

9510-G113-J3F0-Z

Utility vehicles for hazardous goods
ETAL

9510-G113-J3F1

Simulators.
ETAL

9510-G113-J3F1-B

Utility vehicles for hazardous goods
ETAL

9510-G113-J3F1-Z

Utility vehicles for hazardous goods
ETAL

9510-G113-P1F0

Simulators.
ETAL

9510-G113-P1F0-B

Utility vehicles for hazardous goods
ETAL

9510-G113-P1F0-Z

Utility vehicles for hazardous goods
ETAL

9510-G113-P1F1

Simulators.
ETAL

9510-G113-P1F1-B

Utility vehicles for hazardous goods
ETAL

9510-G113-P1F1-Z

Utility vehicles for hazardous goods
ETAL

9510-G113-W4F0

Simulators.
ETAL

9510-G113-W4F0-B

Utility vehicles for hazardous goods
ETAL