117417-01 [ETC]

145MM120V 800W BLDC BLOWER ; 145MM120V 800W直流无刷风机\n
117417-01
型号: 117417-01
厂家: ETC    ETC
描述:

145MM120V 800W BLDC BLOWER
145MM120V 800W直流无刷风机\n

风机
文件: 总57页 (文件大小:2219K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
TM  
WE’RE BIG ON BRUSHLESS  
BRUSHLESS DC MOTORS • BLOWERS • CONTROLLERS  
ROTRON  
Technical Products  
Table of Contents  
Introduction ............................................... 1, 2, 3  
BLDC Motors  
1.7” (43mm) diameter ........................................... 4, 5  
2.5” (64mm) diameter ........................................... 6, 7  
3.0” (79mm) diameter ........................................... 8, 9  
3.55” (90mm) diameter ....................................... 10, 11  
3.9” (99mm) diameter ....................................... 12, 13  
5.25” (133mm) diameter ..................................... 14, 15  
Low Voltage Blowers (BLDC)  
2.9” (74mm)...................................................... 16, 17  
3.0” (76mm)....................................................... 18, 19  
3.3” (84mm)....................................................... 20, 21  
4.5” (114mm)..................................................... 22, 23  
5.0” (127mm) MINIJAMMER®............................. 24, 25  
5.1” (130mm)..................................................... 26, 27  
5.7” (145mm) WINDJAMMER®........................... 28, 29  
High Voltage Blowers (BLDC)  
WINDJAMMER®  
5.7” (145mm) Thru Flow/250 Watt/120VAC ..... 30, 31  
5.7” (145mm) Bypass/250 Watt/120VAC .......... 32, 33  
5.7” (145mm) Thru Flow//400 Watt/240 VAC ... 34, 35  
5.7” (145mm) Bypass/400 Watt/240VAC .......... 36, 37  
5.7” (145mm) Bypass/800 Watt/120VAC .......... 38, 39  
5.7” (145mm) Bypass/1200 Watt/240VAC ........ 40, 41  
Controllers (BLDC)  
5
Amp Motor/Blower .......................................... 42  
10 Amp Motor/Blower .......................................... 43  
20 Amp Motor ...................................................... 44  
BLDC Motor/Blower  
Controller Part Numbers ................................ 45  
Blower/Motor Sizing Sheet ............................ 46  
Application Engineering  
Basics .................................................47, 48, 49, 50, 51  
AMETEK Global Locations........................ 52, 53  
Contact Information ....................................... 54  
Th e AMETEK Ele c t ro m e c h a n ic a l Gro u p (EMG). . .  
is one of the world’s largest producers of high-speed electric motor products for original equipment  
manufacturers (OEMs). In business since 1915, EMG uses its core competencies in motion and air  
movement products as engineered solutions for application-specific needs. A unit of AMETEK EMG,  
Rotron offers Brushless DC motor-, blower-, and controller-based solutions.  
The standard product lines of Rotron Technical Products cover a wide range of application demands.  
If there is a need for a product with unique performance, mounting, environment or agency require-  
ments, Rotron can supply the solution. Whether a customer needs a standard or special design,  
Rotron has the solution for your application. AMETEK offers economies of scale that only can be  
accomplished by a company that produces more than 23 million motor products per year. With  
multiplant capability and flexibility, Rotron is positioned to support our customers’ global programs.  
AMETEK Brushless DC Motors and Blowers are an ideal choice for such varied applications as medi-  
cal instruments, robotics, pumps, compressors, business equipment, fans, machine tools, tape  
drives, or any other precise rotary motion/air delivery applications.  
1
INTRO99  
Bru s h le s s DC Mo t o rs . . .  
offer precise control for a wide range of applications. Rotron standard motor designs offer  
maximum controllable performance, coupled with the reliability of brushless technology in a com-  
pact cost effective package. First introduced in 1988, the AMETEK brushless DC motor product line  
has continually expanded into one of the largest mixes of fractional horsepower motor products in  
the industry.  
Mo t o r S e le c t io n . . .  
is made easy with the wide variety of standard products available from AMETEK. Six different motor  
families are available in standard configurations. These include 1.7” (43mm), 2.5” (64mm), 3.0”  
(76mm), 3.55” (90mm), 3.9” (99mm), and 5.25” (133mm) diameter motors, with constant torque which  
range from 5.75 oz. in. (4.06 Ncm) to 832 oz. in. (5.87 Nm) and horsepower ratings of .014 to 1.75.  
Voltage options range from 12VDC to 74VDC. The table below provides a summary of the motor  
products, operating voltages, speed and torque ranges sorted by motor diameter. Use this chart to  
compare the AMETEK products to the application needs. Detailed motor information is provided on  
the individual product sheets.  
BLDC MOTORS  
Motor Diameter  
Operating Voltage (DC)  
Controller Input  
12, 24, 36  
Speed Range (RPM)  
at Nom. Continuous Torque  
0 - 3,000  
Torque Range (oz. in.)  
Maximum Continuous  
5.75 - 11  
1.7” (43mm)  
2.5” (64mm)  
3.0” (76mm)  
3.55” (90mm)  
3.9” (99mm)  
5.25” (133mm)  
12, 24, 36  
0 - 5,000  
14 - 69  
13.8, 24, 27.6  
12, 24, 36  
0 - 4,930  
19.7 - 55  
0 - 4,300  
22 - 132  
12. 13.8, 27.6, 74  
27, 27.6, 74  
0 - 4,500  
28 - 100  
0 - 4,055  
192 - 832  
Mo t o r Co n t ro lle rs  
All of the AMETEK BLDC Motors require a controller to operate. The controllers require a DC  
input which is processed into phase drive signals. The 1.7” (43mm) and 3.0” (76mm) motors  
are available with integrated controllers. All other motors require an external controller. Con-  
troller details and compatibility to the different motor products are supplied in the controller  
section of the catalog.  
2
INTRO99  
Bru s h le s s DC Blo w e rs . . .  
offer variable (speed) output for a wide range of vacuum or pressure applications. Standard blower  
designs offer brushless DC motor drives coupled to high efficiency fan systems in a compact, cost  
effective package. Standard models are available in a wide range of input voltages, including 12, 24,  
28, and 36VDC. A complete product line of brushless DC blowers that accepts line voltage input  
(120VAC and 240VAC) also is available. AMETEK brushless DC blowers are not designed for, and  
should not be used in, life sustaining applications. AMETEK brushless DC blowers are not 100%  
sealed and therefore should not be used with flammable or hazardous gases.  
Blo w e r S e le c t io n . . .  
offers a wide variety of standard products available from AMETEK. Thirteen different blower families  
are available in standard configurations. These include seven low voltage and six high voltage  
products. The low voltage products provide outputs which range from 0 to 28” H20 (pressure) at  
flows of 0 to 45 CFM. The high voltage products provide outputs which range from 0 to 162” H20  
(pressure) at flows of 0 to 275 CFM.  
LOW VOLTAGE PRODUCTS  
Blower Diameter  
2.9” (74mm)  
3” (76mm)  
Operating Voltage (DC)  
12, 24  
CFM Range  
0-22  
0-18  
0-7  
In. H 0 (Pressure)  
In. H 0 (Vacuum)  
2
2
0-3  
-
12, 24  
0-10  
0-27  
0-28  
0-24  
0-25  
0-28  
-
3.3” (84mm)  
4.5” (114mm)  
5” (127mm)  
12, 24  
-
12, 24  
0-9  
-
12, 24  
0-45  
0-15  
0-39  
-
-
5.1” (130mm)  
5.7” (145mm)  
12, 24  
12, 24, 36  
0-28  
HIGH VOLTAGE BYPASS PRODUCTS  
Blower Diameter  
5.7” (145mm)  
5.7” (145mm)  
5.7” (145mm)  
5.7” (145mm)  
Operating Voltage (AC)  
CFM Range  
0-115  
In. H 0 (Pressure)  
In. H 0 (Vacuum)  
2
2
120 (250 Watt)  
120 (800 Watt)  
240 (400 Watt)  
240 (1200 Watt)  
0-76  
0-115  
0-144  
0-162  
0-65  
0-106  
0-135  
0-118  
0-242  
0-115  
0-275  
HIGH VOLTAGE THRU-FLOW PRODUCTS  
Blower Diameter  
5.7” (145mm)  
5.7” (145mm)  
Operating Voltage (AC)  
CFM Range  
0-117  
In. H 0 (Pressure)  
In. H 0 (Vacuum)  
2
2
120 (250 Watt)  
240 (400 Watt)  
0-75  
0-50  
0-70  
0-47  
0-67  
3
INTRO99  
1 .7 ” (4 3 m m ) Dia m e t e r, 8 P o le , Bru s h le s s DC Mo t o r  
2 4 VDC  
Unit of  
Me as ure  
RPM  
Part Numbe rs  
Motor Da ta  
119272*  
4388  
.16  
119275*  
No Load Speed, Nominal  
No Load Current, Nominal  
Stall Torque, Theoretical  
4308  
.18  
amps  
oz.-in.  
12.7  
8.96  
5.75  
4.06  
51.3  
36.20  
11  
Ncm  
Continuous Torque  
oz.-in.  
Ncm  
7.77  
Speed @ Torque, Nominal  
Current @ Torque, Nominal  
Continuous Power, Max.  
Torque Constant  
RPM  
2425  
1.0  
3000  
1.75  
24  
amps  
watts out  
oz.-in. /amp  
Ncm/amp  
V/kRPM  
V/rad/sec  
millisecond  
millisecond  
oz.-in./(watt^.5)  
Ncm/(watt^.5)  
oz.-in.sec2  
Ncm-sec^2  
ohms  
10  
7.39  
5.21  
7.53  
5.31  
Voltage Constant  
5.47  
5.57  
0.052  
.273  
.202  
0.053  
.339  
Electrical Time Constant  
Mechanical Time Constant  
Motor Constant  
.134  
2.37  
4.12  
1.67  
2.91  
Rotor Inertia  
8.00 x 10-6  
0.0565  
9.74  
2.66  
3.5  
1.60 x 10-5  
0.0113  
3.34  
1.13  
Terminal Resistance  
Terminal Inductance  
Thermal Resistance  
Length (“L” above)  
millihenry  
ºC/W  
1.90  
inches  
1.864  
47.35  
.51  
2.614  
66.40  
.78  
mm  
Weight  
lb.  
kg  
0.23  
0.35  
Shaft Length (S” above)  
inches  
.75  
1.00  
25.40  
mm  
19.05  
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.  
NOTES  
* Motors require brushless motor controller for operation, refer to the controller section (page 45) for applicable controllers.  
* Motor design characteristics are based on an operating environment of 25ºC.  
* Nominal and maximum performance figures are based on a winding temperature of 105ºC.  
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.  
* AMETEK RTMD products are not designed for and should not be used in medical life support applications.  
* AMETEK reserves the right to revise its products without notification.  
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK RTMD Marketing and Sales.  
4
1.7M99  
1 .7 ” (4 3 m m ) Dia m e t e r, 8 P o le , Bru s h le s s DC Mo t o r  
2 4 VDC  
This doc ume nt is for informa l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The  
pe rforma nc e da ta on this pa ge de pic ts typic a l pe rforma nc e unde r c ontrolle d la bora tory c onditions us ing AMETEK BLDC motor c ontrolle rs . Ac tua l pe rforma nc e will  
va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for a nd s hould not be us e d in me dic a l life s upport  
a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.  
1.7M99  
5
2 .5 ” (6 4 m m ) Dia m e t e r, 8 P o le , Bru s h le s s DC Mo t o r  
2 4 VDC  
Unit of  
Me as ure  
RPM  
Part Numbe rs  
Motor Da ta  
119000*  
5947  
1.14  
142  
119001  
5389  
1.07  
179  
119002  
4233  
0.93  
191  
119003*  
119004  
4636  
0.98  
282  
119005  
4019  
0.91  
294  
119006  
3575  
0.85  
302  
119007  
119008*  
2879  
0.77  
No Load Speed, Nominal  
No Load Current, Nominal  
Stall Torque, Theoretical  
5468  
1.08  
267  
3191  
0.81  
amps  
oz.-in.  
311  
319  
Ncm  
100  
127  
135  
189  
199  
208  
213  
219  
225  
Continuous Torque  
oz.-in.  
14  
21  
27  
34  
41  
48  
55  
62  
69  
Ncm  
10  
15  
19  
24  
29  
34  
39  
44  
49  
Speed @ Torque, Nominal  
Current @ Torque, Nominal  
Continuous Power, Max.  
Torque Constant  
RPM  
4928  
3.7  
4234  
4.6  
3286  
4.5  
4228  
6.8  
3455  
6.8  
3074  
6.8  
2645  
6.9  
2290  
6.9  
2002  
6.9  
amps  
watts out  
oz.-in. /amp  
Ncm/amp  
V/kRPM  
V/rad/sec  
millisecond  
millisecond  
oz.-in./(watt^.5)  
Ncm/(watt^.5)  
oz.-in.sec2  
Ncm-sec^2  
ohms  
51  
66  
66  
106  
105  
109  
108  
105  
102  
5.46  
3.85  
4.04  
0.0385  
0.838  
5.236  
6.8  
6.02  
4.25  
4.45  
0.0425  
0.886  
4.129  
8.1  
7.67  
5.42  
5.67  
0.0542  
0.937  
4.080  
9.3  
5.94  
4.19  
4.39  
0.0419  
0.904  
3.775  
10.1  
7.1  
7.00  
4.94  
5.18  
0.0494  
0.938  
4.006  
11.1  
7.9  
8.08  
5.70  
5.97  
0.0570  
0.965  
3.668  
12.1  
8.6  
9.08  
6.41  
6.71  
0.0641  
0.986  
3.217  
12.9  
9.1  
10.17  
7.18  
11.27  
7.96  
Voltage Constant  
7.52  
8.34  
0.0718  
1.004  
3.258  
13.8  
0.0796  
1.019  
3.021  
14.7  
Electrical Time Constant  
Mechanical Time Constant  
Motor Constant  
4.8  
5.7  
6.6  
9.8  
10.4  
Rotor Inertia  
0.0017  
0.0012  
0.648  
0.543  
1.26  
2.335  
59.31  
1.15  
0.52  
.750  
19.05  
0.0019  
0.0013  
0.557  
0.493  
1.22  
2.335  
59.31  
1.25  
0.57  
.750  
19.05  
0.0025  
0.0018  
0.678  
0.635  
1.19  
2.835  
72.01  
1.60  
0.73  
.750  
19.05  
0.0027  
0.0019  
0.348  
0.314  
1.15  
2.835  
72.01  
1.75  
0.79  
.750  
19.05  
0.0035  
0.0025  
0.396  
0.372  
1.11  
3.585  
91.06  
2.15  
0.98  
1.500  
38.1  
0.0038  
0.0027  
0.444  
0.429  
1.08  
3.585  
91.06  
2.25  
1.02  
1.500  
38.1  
0.0038  
0.0027  
0.493  
0.486  
1.04  
3.585  
91.06  
2.30  
1.04  
1.500  
38.1  
0.0044  
0.0031  
0.541  
0.543  
1.00  
0.0046  
0.0032  
0.589  
0.601  
0.96  
Terminal Resistance  
Terminal Inductance  
Thermal Resistance  
Length (“L” above)  
millihenry  
ºC/W  
inches  
4.085  
103.76  
2.70  
4.085  
103.76  
2.80  
mm  
Weight  
lb.  
kg  
1.22  
1.27  
Shaft Length (S” above)  
inches  
1.875  
47.63  
1.875  
47.63  
mm  
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.  
NOTES  
* Motors require brushless motor controller for operation, refer to the controller section ( page 45) for applicable controllers.  
* Motor design characteristics are based on an operating environment of 25ºC.  
* Nominal and maximum performance figures are based on a winding temperature of 105ºC.  
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.  
* AMETEK RTMD products are not designed for and should not be used in medical life support applications.  
* AMETEK reserves the right to revise its products without notification.  
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK RTMD Marketing and Sales.  
2.5M99  
6
2 .5 ” (6 4 m m ) Dia m e t e r, 8 P o le , Bru s h le s s DC Mo t o r  
2 4 VDC  
This doc ume nt is for informa l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The  
pe rforma nc e da ta on this pa ge de pic ts typic a l pe rforma nc e unde r c ontrolle d la bora tory c onditions us ing AMETEK BLDC motor c ontrolle rs . Ac tua l pe rforma nc e will  
va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for a nd s hould not be us e d in me dic a l life s upport  
a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.  
2.5M99  
7
3 .0 ” (7 9 m m ) Dia m e t e r, 4 P o le , Bru s h le s s DC Mo t o r  
This drawing is a general outline. For a more detailed drawing please contact AMETEK Rotron.  
Unit of  
Part Numbe rs  
Motor Da ta  
Me as ure  
Volts DC  
RPM  
150004  
13.8  
*150007  
E-11488  
24.0  
5400  
1.5  
Voltage Input  
27.6  
5510  
1
No Load Speed, Nominal  
No Load Current, Nominal  
Stall Torque, Theoretical  
3770  
0.75  
169  
amps  
oz.-in.  
Ncm  
1300  
915  
1298  
917  
119  
Continuous Torque  
oz.-in.  
Ncm  
19.7  
13.9  
43  
55  
30  
39  
Speed @ Torque, Nominal  
Current @ Torque, Nominal  
Continuous Power  
RPM  
2927  
4.6  
4930  
6.9  
4400  
9.9  
amps  
watts  
43  
157  
181  
Torque Constant  
oz.-in. /amp  
Ncm/amp  
V/kRPM  
V/rad/sec  
inches  
mm  
4.90  
3.46  
7.43  
6.00  
4.24  
4.44  
0.0424  
4.27  
108.46  
TBD  
5.25  
Voltage Constant  
3.66  
5
0.035  
3.25  
82.63  
1.7  
0.048  
3.77  
Length (“L” above)  
Weight  
95.76  
3
lb.  
kg  
0.776  
.3152  
8.0060  
1.87  
47.50  
Internal  
1.359  
.281  
Shaft Diameter (“D” above)  
Shaft Length (S” above)  
inches  
mm  
.281  
7.137  
7.137  
3.50/3.50  
88.90/88.90  
External  
48129-03  
inches  
mm  
1.37  
34.75  
Drive Electronics  
Internal or External  
External  
48129-11  
Electronic Drive Part Number  
*Part Number 150007 has a dual shaft.  
NOTES  
* Motor design characteristics are based on an operating environment of 25ºC.  
* Nominal and maximum performance figures are based on a winding temperature of 105ºC.  
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.  
* AMETEK Rotron products are not designed for and should not be used in medical life support applications.  
* AMETEK reserves the right to revise its products without notification.  
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales.  
3.0M99  
8
3 .0 ” (7 9 m m ) Dia m e t e r, 4 P o le , Bru s h le s s DC Mo t o r  
Exte rnal Drive Part Numbe r  
4 8 1 2 9 -0 3  
Exte rnal Drive Part Numbe r  
4 8 1 2 9 -1 1  
This doc ume nt is for informa l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The  
pe rformance data on this page de picts typical pe rformance unde r controlle d laboratory conditions us ing AMETEK BLDC motor contro lle rs . Ac tua l pe rforma nc e will  
va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for a nd s hould not be us e d in me dic a l life s upport  
a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.  
3.0M99  
9
3 .5 5 ” (9 0 m m ) Dia m e t e r, 8 P o le , Bru s h le s s DC Mo t o r  
2 4 VDC  
Unit of  
Me as ure  
RPM  
Part Numbe rs  
Motor Da ta  
119050*  
4319  
1.48  
119051  
5259  
1.74  
119052  
4067  
1.41  
119053*  
119054  
2838  
1.07  
119055  
2543  
0.99  
119056  
2281  
0.92  
119057  
119058*  
1856  
0.80  
No Load Speed, Nominal  
No Load Current, Nominal  
Stall Torque, Theoretical  
3434  
1.24  
2021  
0.85  
amps  
oz.-in.  
284  
375  
428  
453  
496  
505  
518  
541  
549  
Ncm  
201  
265  
302  
320  
350  
357  
366  
382  
387  
Continuous Torque  
oz.-in.  
22  
36  
49  
63  
77  
91  
105  
119  
132  
Ncm  
16  
25  
35  
44  
54  
64  
74  
84  
93  
Speed @ Torque, Nominal  
Current @ Torque, Nominal  
Continuous Power, Max.  
Torque Constant  
RPM  
3715  
4.4  
4342  
7.6  
3265  
7.6  
2641  
7.9  
2174  
7.8  
1864  
8.1  
1605  
8.3  
1377  
8.3  
1214  
8.4  
amps  
watts out  
oz.-in. /amp  
Ncm/amp  
V/kRPM  
V/rad/sec  
millisecond  
millisecond  
oz.-in./(watt^.5)  
Ncm/(watt^.5)  
oz.-in.sec2  
Ncm-sec^2  
ohms  
60  
116  
118  
123  
124  
126  
125  
121  
119  
7.52  
6.17  
7.98  
9.45  
6.68  
11.44  
8.08  
12.77  
9.02  
14.23  
10.05  
10.52  
0.1005  
1.331  
9.413  
21.4  
16.06  
11.34  
11.88  
0.1134  
1.358  
9.313  
23.1  
17.49  
12.35  
12.93  
0.1235  
1.382  
8.754  
24.1  
5.31  
4.36  
5.64  
Voltage Constant  
5.56  
4.56  
5.90  
6.99  
8.46  
9.44  
0.0531  
1.055  
14.713  
11.5  
0.0436  
1.052  
13.065  
12.5  
0.0564  
1.140  
12.005  
15.0  
0.0667  
1.205  
10.293  
16.6  
0.0808  
1.256  
11.253  
19.0  
0.0901  
1.297  
10.283  
20.1  
Electrical Time Constant  
Mechanical Time Constant  
Motor Constant  
8.1  
8.9  
10.6  
11.7  
13.4  
14.2  
15.1  
16.3  
17.0  
Rotor Inertia  
0.0138  
0.0097  
0.425  
0.449  
1.21  
0.0145  
0.0102  
0.242  
0.255  
1.19  
0.0191  
0.0135  
0.283  
0.322  
1.17  
0.0201  
0.0142  
0.323  
0.389  
1.15  
0.0286  
0.0202  
0.363  
0.457  
1.13  
0.0293  
0.0207  
0.404  
0.524  
1.11  
0.0303  
0.0214  
0.444  
0.591  
1.09  
0.0350  
0.0247  
0.485  
0.658  
1.06  
0.0360  
0.0254  
0.525  
0.726  
1.04  
Terminal Resistance  
Terminal Inductance  
Thermal Resistance  
Length (“L” above)  
millihenry  
ºC/W  
inches  
2.500  
63.50  
2.10  
2.500  
63.50  
2.25  
3.000  
76.20  
2.80  
3.000  
76.20  
3.00  
3.750  
95.25  
3.75  
3.750  
95.25  
4.00  
3.750  
95.25  
4.20  
4.250  
107.95  
4.70  
4.250  
107.95  
4.85  
mm  
Weight  
lb.  
kg  
0.95  
1.02  
1.27  
1.36  
1.70  
1.81  
1.90  
2.13  
2.20  
Shaft Length (S” above)  
inches  
.750  
19.05  
.750  
19.05  
.750  
.750  
19.05  
1.500  
38.10  
1.500  
38.10  
1.500  
38.10  
1.875  
47.63  
1.875  
47.63  
mm  
19.05  
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.  
NOTES  
* Motors require brushless motor controller for operation, refer to the controller section (page 45) for applicable controllers.  
* Motor design characteristics are based on an operating environment of 25ºC.  
* Nominal and maximum performance figures are based on a winding temperature of 105ºC.  
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.  
* AMETEK RTMD products are not designed for and should not be used in medical life support applications.  
* AMETEK reserves the right to revise its products without notification.  
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK RTMD Marketing and Sales.  
3.55M99  
1 0  
3 .5 5 ” (9 0 m m ) Dia m e t e r, 8 P o le , Bru s h le s s DC Mo t o r  
2 4 VDC  
This doc ume nt is for informa l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The  
pe rformance data on this page de picts typical pe rformance unde r controlle d laboratory conditions us ing AMETEK BLDC motor contro lle rs . Ac tua l pe rforma nc e will  
va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK RTMD produc ts a re not de s igne d for a nd s hould not be us e d in me dic a l life s upport  
a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.  
1 1  
3.55M99  
3 .9 ” (9 9 m m ) Dia m e t e r, 4 P o le , Bru s h le s s DC Mo t o r  
This drawing is a general outline. For a more detailed drawing please contact AMETEK Rotron.  
Unit of  
Part Numbe rs  
Motor Da ta  
Me as ure  
Volts DC  
RPM  
071033  
12  
071070  
071031  
071145  
27.6  
3000  
0.5  
Voltage Input  
13.8  
3750  
2.5  
74  
No Load Speed, Nominal  
No Load Current, Nominal  
Stall Torque, Theoretical  
6700  
1
3700  
0.22  
334  
amps  
oz.-in.  
Ncm  
72  
210  
453  
51  
148  
236  
320  
Continuous Torque  
oz.-in.  
Ncm  
28  
60  
85  
100  
20  
42  
60  
71  
Speed @ Torque, Nominal  
Current @ Torque, Nominal  
Continuous Power  
RPM  
4500  
14  
2527  
14.3  
113  
2700  
3.2  
2100  
8
amps  
watts  
94  
171  
155  
Torque Constant  
oz.-in. /amp  
Ncm/amp  
V/kRPM  
V/rad/sec  
inches  
mm  
2.42  
1.71  
1.79  
0.0171  
5.33  
135.38  
6.4  
4.98  
3.51  
3.68  
0.0351  
6.08  
154.43  
7.3  
27.04  
19.10  
20  
12.44  
8.79  
9.20  
0.0879  
7.68  
195.07  
9.3  
Voltage Constant  
Length (“L” above)  
Weight  
0.1910  
6.68  
169.67  
8.0  
lb.  
kg  
2.9  
3.3  
3.6  
4.2  
Shaft Diameter (“D” above)  
Shaft Length (S” above)  
Drive Electronics  
inches  
mm  
.2495  
6.337  
.83  
.6250  
15.8750  
1.00  
25.40  
Internal  
.312  
7.925  
1.65  
41.91  
Internal  
.4997  
12.6924  
2.25  
57.15  
Internal  
inches  
mm  
21.08  
Internal  
NOTES  
* Motor design characteristics are based on an operating environment of 25ºC.  
* Nominal and maximum performance figures are based on a winding temperature of 105ºC.  
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.  
* AMETEK Rotron products are not designed for and should not be used in medical life support applications.  
* AMETEK reserves the right to revise its products without notification.  
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales.  
3.9M99  
1 2  
3 .9 ” (9 9 m m ) Dia m e t e r, 4 P o le , Bru s h le s s DC Mo t o r  
This doc ume nt is for informa l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The  
pe rformance data on this page de picts typical pe rformance unde r controlle d laboratory conditions us ing AMETEK BLDC motor contro lle rs . Ac tua l pe rforma nc e will  
va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for a nd s hould not be us e d in me dic a l life s upport  
a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.  
3.9M99  
1 3  
5 .2 5 ” (1 3 3 m m ) Dia m e t e r, 4 P o le , Bru s h le s s DC Mo t o r  
This drawing is a general outline. For a more detailed drawing please contact AMETEK Rotron.  
Unit of  
Part Numbe rs  
Motor Da ta  
Me as ure  
Volts DC  
RPM  
528512  
27.6  
071087  
27  
071190  
524647  
74  
*524506  
27  
Voltage Input  
27  
1765  
0.7  
No Load Speed, Nominal  
No Load Current, Nominal  
Stall Torque, Theoretical  
4055  
1.6  
1935  
0.8  
2565  
0.62  
2000  
amps  
2.5  
oz.-in.  
Ncm  
2403  
1697  
192  
4380  
3094  
368  
6400  
4519  
560  
18000  
12707  
720  
15383  
10862  
832  
Continuous Torque  
oz.-in.  
Ncm  
136  
260  
395  
508  
587  
Speed @ Torque, Nominal  
Current @ Torque, Nominal  
Continuous Power  
RPM  
3250  
23  
1573  
20  
1445  
27.5  
2253  
18.5  
1750  
amps  
46.0  
watts  
467  
433  
605  
1214  
39.01  
27.55  
28.85  
0.2755  
8.91  
1090  
Torque Constant  
oz.-in. /amp  
Ncm/amp  
V/kRPM  
V/rad/sec  
inches  
mm  
9.20  
6.21  
6.81  
0.0621  
6.76  
171.70  
18  
18.85  
13.31  
13.94  
0.1331  
7.86  
20.68  
14.61  
15.30  
0.1461  
10.36  
263.14  
23  
18.25  
12.89  
13.50  
0.1289  
10.09  
256.29  
27  
Voltage Constant  
Length (“L” above)  
Weight  
199.64  
20  
226.31  
24  
lb.  
kg  
8.2  
9.1  
10.4  
10.9  
12.2  
Shaft Diameter (“D” above)  
Shaft Length (S” above)  
inches  
mm  
.3747  
9.5174  
1.00  
25.40  
Internal  
.6250  
15.8750  
2.06  
.7497  
19.0424  
3.25  
.7497  
19.0424  
7.09  
.6250  
15.8750  
2.05/2.05  
52.07/52.07  
External  
inches  
mm  
52.32  
Internal  
82.55  
Internal  
180.09  
External  
Drive Electronics  
Internal or External  
Drive Electronics Part Number  
N/A  
N/A  
N/A  
524731  
524508  
*Part Number 524506 has a dual shaft.  
NOTES  
* Motor design characteristics are based on an operating environment of 25ºC.  
* Nominal and maximum performance figures are based on a winding temperature of 105ºC.  
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.  
* AMETEK RTMD products are not designed for and should not be used in medical life support applications.  
* AMETEK reserves the right to revise its products without notification.  
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK RTMD Marketing and Sales.  
5.25M99  
1 4  
5 .2 5 ” (1 3 3 m m ) Dia m e t e r, 4 P o le , Bru s h le s s DC Mo t o r  
Exte rnal Drive Part Numbe r  
5 2 4 7 3 1  
5 2 4 5 0 8  
This doc ume nt is for informa l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The  
pe rforma nc e da ta on this pa ge de pic ts typic a l pe rforma nc e unde r c ontrolle d la bora tory c onditions us ing AMETEK BLDC motor c ontrolle rs . Ac tua l pe rforma nc e will  
va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for a nd s hould not be us e d in me dic a l life s upport  
a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.  
5.25M99  
1 5  
2 .9 ” (7 4 m m ) BLDC Lo w -Vo lt a g e Blo w e r  
1 2 /2 4 VDC  
Unit of  
Part Numbe r  
Blowe r Data  
Me as ure  
Voltage Input  
119495  
12  
119496  
24  
VDC  
Stages  
1
1
Pressure, Max. (Sealed Pressure)  
in. H2O, Sealed  
mBar  
3.4  
8.4  
22  
3.4  
8.4  
22  
Flow Rate, Max. (Open Flow)  
CFM  
L/sec  
10.4  
10.4  
Typical Pe rformance Points  
Air Flow  
0 CFM  
Pre s s ure  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
3.4  
3.1  
2.9  
2.5  
1.8  
3.4  
3.1  
2.9  
2.5  
1.8  
4 CFM  
8 CFM  
12 CFM  
16 CFM  
Temperature: Working Air: 0o C to 45°C, Ambient Air: 0o C to 45°C, Storage Air: -40o C to 85°C  
Dielectric Testing: 200 volts applied for one second between power leads and motor body, one milliamp leakage max.  
Speed Control: Speed is controlled by input voltage.  
NOTES:  
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.  
* AMETEK Rotron products are not designed for and should not be used in medical life support applications.  
* AMETEK reserves the right to revise its products without notification.  
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales.  
1 6  
2.9BLV99  
2 .9 ” (7 4 m m ) BLDC Lo w -Vo lt a g e Blo w e r  
1 2 /2 4 VDC  
This doc ume nt is for informa tiona l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The  
pe rformance data on this page de picts typical pe rformance unde r controlle d laboratory conditions , data is corre cte d to 0.075 lb ./ft3 a ir de ns ity (29.92” Hg @ 7F.).  
Ac tua l pe rforma nc e will va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for us e with vola tile , ha za rdous or  
corros ive gas e s . Blowe r hous ings are not s e ale d, s light air/gas le akage will occur. AMETEK Rotron products are not de s igne d for a nd s hould not be us e d in me dic a l  
life s upport a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.  
1 7  
2.9BLV99  
3 .0 ” (7 6 m m ) BLDC Lo w -Vo lt a g e Blo w e r  
1 2 /2 4 VDC  
Unit of  
Part Numbe r  
Blowe r Data  
Me as ure  
119349*  
119350*  
Voltage Input  
VDC  
12  
1
24  
1
Stages  
Pressure, Max. (Sealed Pressure)  
in. H2O, Sealed  
mBar  
10  
10  
24.9  
18  
24.9  
18  
Flow Rate, Max. (Open Flow)  
CFM  
L/sec  
8.5  
8.5  
Typical Pe rformance Points  
Air Flow  
0 CFM  
Pre s s ure  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
10  
9.1  
7.6  
5.4  
2.4  
0
10  
9.1  
7.6  
5.4  
2.4  
0
4 CFM  
8 CFM  
12 CFM  
16 CFM  
18 CFM  
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.  
Temperature: Working Air: 0o C to 45°C, Ambient Air: 0o C to 45°C, Storage Air: -40o C to 85°C  
Dielectric Testing: 200 volts applied for one second between power leads and motor body, one milliamp leakage max.  
Speed Control: Speed is controlled by input voltage.  
NOTES:  
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.  
* AMETEK Rotron products are not designed for and should not be used in medical life support applications.  
* AMETEK reserves the right to revise its products without notification.  
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales.  
1 8  
3BLV99  
3 .0 ” (7 6 m m ) BLDC Lo w -Vo lt a g e Blo w e r  
1 2 /2 4 VDC  
This doc ume nt is for informa tiona l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The  
pe rformance data on this page de picts typical pe rformance unde r controlle d laboratory conditions , data is corre cte d to 0.075 lb ./ft3 a ir de ns ity (29.92” Hg @ 7F.).  
Ac tua l pe rforma nc e will va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for us e with vola tile , ha za rdous or  
corros ive gas e s . Blowe r hous ings are not s e ale d, s light air/gas le akage will occur. AMETEK Rotron products are not de s igne d for a nd s hould not be us e d in me dic a l  
life s upport a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.  
3BLV99  
1 9  
3 .3 ” (8 4 m m ) BLDC Lo w -Vo lt a g e Blo w e r  
1 2 /2 4 VDC  
Unit of  
Part Numbe r  
Blowe r Data  
Me as ure  
Voltage Input  
119497  
12  
119498  
24  
VDC  
Stages  
1
1
Pressure, Max. (Sealed Pressure)  
in. H2O, Sealed  
mBar  
27.3  
67.9  
7.5  
27.3  
67.9  
7.5  
Flow Rate, Max. (Open Flow)  
CFM  
L/sec  
3.5  
3.5  
Typical Pe rformance Points  
Air Flow  
0 CFM  
Pre s s ure  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
27.0  
26.0  
20.5  
9.0  
27.0  
26.0  
20.5  
9.0  
2 CFM  
4 CFM  
6 CFM  
8 CFM  
0
0
Temperature: Working Air: 0o C to 45°C, Ambient Air: 0o C to 45°C, Storage Air: -40o C to 85°C  
Dielectric Testing: 200 volts applied for one second between power leads and motor body, one milliamp leakage max.  
Speed Control: Speed is controlled by input voltage.  
NOTES:  
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.  
* AMETEK Rotron products are not designed for and should not be used in medical life support applications.  
* AMETEK reserves the right to revise its products without notification.  
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales.  
2 0  
3.3BLV99  
3 .3 ” (8 4 m m ) BLDC Lo w -Vo lt a g e Blo w e r  
1 2 /2 4 VDC  
This doc ume nt is for informa tiona l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The  
pe rformance data on this page de picts typical pe rformance unde r controlle d laboratory conditions , data is corre cte d to 0.075 lb ./ft3 a ir de ns ity (29.92” Hg @ 7F.).  
Ac tua l pe rforma nc e will va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for us e with vola tile , ha za rdous or  
corros ive gas e s . Blowe r hous ings are not s e ale d, s light air/gas le akage will occur. AMETEK Rotron products are not de s igne d for a nd s hould not be us e d in me dic a l  
life s upport a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.  
2 1  
3.3BLV99  
4 .5 ” (1 1 4 m m ) BLDC Lo w -Vo lt a g e Blo w e r  
1 2 /2 4 VDC  
Unit of  
Me as ure  
Part Numbe r  
Blowe r Data  
119494  
119395  
24  
Voltage Input  
VDC  
12  
1
Stages  
1
Pressure, Max. (Sealed Pressure)  
in. H2O, Sealed  
mBar  
28.4  
70.7  
9.1  
4.3  
28.4  
70.7  
9.1  
Flow Rate, Max. (Open Flow)  
CFM  
L/sec  
4.3  
Typical Pe rformance Points  
Air Flow  
0 CFM  
Pre s s ure  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
28.4  
26.2  
22.4  
15.3  
5.6  
28.4  
26.2  
22.4  
15.3  
5.6  
2 CFM  
4 CFM  
6 CFM  
8 CFM  
10 CFM  
0
0
Temperature: Working Air: 0o C to 45°C, Ambient Air: 0o C to 45°C, Storage Air: -40o C to 85°C  
Dielectric Testing: 200 volts applied for one second between power leads and motor body, one milliamp leakage max.  
Speed Control: Speed is controlled by input voltage.  
NOTES:  
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.  
* AMETEK Rotron products are not designed for and should not be used in medical life support applications.  
* AMETEK reserves the right to revise its products without notification.  
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales.  
2 2  
4.5BLV99  
4 .5 ” (1 1 4 m m ) BLDC Lo w -Vo lt a g e Blo w e r  
1 2 /2 4 VDC  
This doc ume nt is for informa tiona l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The  
pe rformance data on this page de picts typical pe rformance unde r controlle d laboratory conditions , data is corre cte d to 0.075 lb ./ft3 a ir de ns ity (29.92” Hg @ 7F.).  
Ac tua l pe rforma nc e will va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for us e with vola tile , ha za rdous or  
corros ive gas e s . Blowe r hous ings are not s e ale d, s light air/gas le akage will occur. AMETEK Rotron products are not de s igne d for a nd s hould not be us e d in me dic a l  
life s upport a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.  
2 3  
4.5BLV99  
5 .0 ” (1 2 7 m m ) BLDC Lo w -Vo lt a g e Blo w e r  
1 2 /2 4 VDC  
Part Number  
Standard Flow  
Unit  
Measure  
High Output  
Blower Data  
119381 M  
119384 M  
119385 E  
119378 M  
119380  
119382 E  
119383  
119375  
119379 E  
Voltage Input  
VDC  
12  
12  
1
24  
24  
1
24  
24  
1
Stages  
1
12  
1
12  
1
24  
Pressure, Max. (Sealed Pressure)  
in. H2O  
mBar  
12  
12  
24  
30  
30  
30  
30  
60  
60  
Flow Rate, Max. (Open Flow)  
Drive Electronics  
CFM  
34  
34  
34  
34  
45  
45  
L/sec  
16  
16  
16  
16  
21  
21  
Internal or External  
External  
Internal  
External  
Internal  
External  
Internal  
Typical Performance Points  
Pressure  
Air Flow  
0 CFM  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
12.5  
11.7  
7.6  
12.5  
11.7  
7.6  
12.5  
11.7  
7.6  
12.5  
11.7  
7.6  
24.3  
22.0  
18.4  
10.8  
3.5  
24.3  
22.0  
18.4  
10.8  
3.5  
10 CFM  
20 CFM  
30 CFM  
40 CFM  
2.3  
2.3  
2.3  
2.3  
NOTES:  
Temperature: Working Air: 0o C to 45°C, Ambient Air: 0o C to 45°C, Storage Air: -40o C to 85°C  
Dielectric Testing: 500 volts AC RMS 60Hz applied for one second between input pins and ground, one milliamps leakage max.  
Speed Control: Internal – E (Electrical): Pulse Width Modulated or Analog input voltage (User Supplied), 0 to 5 Volts DC Nominal  
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed.  
External - These blowers require a 3 phase electronic commutated input to operate. A separate blower controller provides this input and speed  
control. AMETEK blower controller part numbers 48069 for 12VDC blowers and 48070 for 24 VDC blowers are design for use with the  
above blowers.  
2 4  
5BLV99  
5 .0 ” (1 2 7 m m ) BLDC Lo w -Vo lt a g e Blo w e r  
1 2 /2 4 VDC  
This doc ume nt is for informa tiona l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The  
pe rformance data on this page de picts typical pe rformance unde r controlle d laboratory conditions , data is corre cte d to 0.075 lb ./ft3 a ir de ns ity (29.92” Hg @ 7F.).  
Ac tua l pe rforma nc e will va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for us e with vola tile , ha za rdous or  
corros ive gas e s . Blowe r hous ings are not s e ale d, s light air/gas le akage will occur. AMETEK Rotron products are not de s igne d for a nd s hould not be us e d in me dic a l  
life s upport a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.  
2 5  
5BLV99  
5 .1 ” (1 3 0 m m ) BLDC Lo w -Vo lt a g e Blo w e r  
1 2 /2 4 VDC  
Unit of  
Me as ure  
Part Numbe r  
Blowe r Data  
119396  
119397  
24  
Voltage Input  
VDC  
12  
1
Stages  
1
Pressure, Max. (Sealed Pressure)  
in. H2O, Sealed  
mBar  
25.70  
64  
25.70  
64  
Flow Rate, Max. (Open Flow)  
CFM  
15.30  
7.22  
15.30  
7.22  
L/sec  
Typical Pe rformance Points  
Air Flow  
0 CFM  
Pre s s ure  
25.7  
23.8  
21.7  
19.5  
16.5  
12.0  
7.1  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
25.7  
23.8  
21.7  
19.5  
16.5  
12.0  
7.1  
2 CFM  
4 CFM  
6 CFM  
8 CFM  
10 CFM  
12 CFM  
14 CFM  
16 CFM  
2.2  
2.2  
0
0
Input voltage: This product requires a 3 phase electronic commutated input to operate. Refer to the controller section of this catalog for proper controller selection.  
Input voltages listed in the chart above indicate the controller input voltage requirement.  
Temperature: Working Air: 0o C to 45°C, Ambient Air: 0o C to 45°C, Storage Air: -40o C to 85°C  
Dielectric Testing: 200 volts applied for one second between power leads and motor body, one milliamp leakage max.  
Speed Control: Via 0.5 VDC analog signal or potentiometer setting at controller.  
NOTES:  
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.  
* AMETEK Rotron products are not designed for and should not be used in medical life support applications.  
* AMETEK reserves the right to revise its products without notification.  
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales.  
2 6  
5.1BLV99  
5 .1 ” (1 3 0 m m ) BLDC Lo w -Vo lt a g e Blo w e r  
1 2 /2 4 VDC  
This doc ume nt is for informa tiona l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The  
pe rformance data on this page de picts typical pe rformance unde r controlle d laboratory conditions , data is corre cte d to 0.075 lb ./ft3 a ir de ns ity (29.92” Hg @ 7F.).  
Ac tua l pe rforma nc e will va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for us e with vola tile , ha za rdous or  
corros ive gas e s . Blowe r hous ings are not s e ale d, s light air/gas le akage will occur. AMETEK Rotron products are not de s igne d for a nd s hould not be us e d in me dic a l  
life s upport a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.  
2 7  
5.1BLV99  
5 .7 ” (1 4 5 m m ) BLDC Lo w -Vo lt a g e Blo w e r  
2 4 VDC  
Unit of  
Me as ure  
Part Numbe rs  
Blowe r Data  
116521*  
24  
116522  
116450*  
24  
Voltage Input  
VDC  
24  
Stages  
1
2
3
Vacuum, Max. (Sealed Vacuum)  
in. H2O  
mBar  
6
20  
24  
15  
50  
60  
Pressure, Max. (Sealed Pressure)  
Flow Rate, Max. (Open Flow)  
Length Dimension L”  
in. H2O, sealed  
mBar  
8.2  
20  
22  
26  
55  
64  
CFM  
39  
35  
38  
L/sec  
18  
17  
18  
inches  
2.65  
67.31  
3.66  
92.96  
4.56  
115.82  
mm  
Typical Pe rformance Points  
Air Flow  
0 CFM  
Pre s s ure  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
8.2  
8.0  
7.6  
7.2  
6.3  
5.0  
3.3  
1.7  
35.7  
18.1  
15.5  
12.8  
10.0  
6.3  
26.0  
23.0  
22.0  
20.5  
17.5  
13.0  
8.5  
5 CFM  
10 CFM  
15 CFM  
20 CFM  
25 CFM  
30 CFM  
35 CFM  
4.0  
0.10  
3.0  
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.  
Input voltage: This product requires a 3 phase electronic commutated input to operate. Refer to the controller section of this catalog for proper controller selection.  
Input voltages listed in the chart above indicate the controller input voltage requirement.  
Input current: 6-10 Amps, Current is dependent on blower model.  
Temperature: Working Air: 0o C to 45°C, Ambient Air: 0o C to 45°C, Storage Air: -40o C to 85°C  
Dielectric Testing: 500 volts AC RMS 60Hz applied for one second between input pins and ground, one milliamp leakage max.  
Speed Control: Speed control is achieved at the blower controller. Refer to the controller section (PAGE 45) of this catalog for proper controller operation.  
NOTES:  
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.  
* AMETEK Rotron products are not designed for and should not be used in medical life support applications.  
* AMETEK reserves the right to revise its products without notification.  
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales.  
5.7BLV99  
2 8  
5 .7 ” (1 4 5 m m ) BLDC Lo w -Vo lt a g e Blo w e r  
2 4 VDC  
This doc ume nt is for informa tiona l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The  
pe rformance data on this page de picts typical pe rformance unde r controlle d laboratory conditions , data is corre cte d to 0.075 lb ./ft3 a ir de ns ity (29.92” Hg @ 7F.).  
Ac tua l pe rforma nc e will va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for us e with vola tile , ha za rdous or  
corros ive gas e s . Blowe r hous ings are not s e ale d, s light air/gas le akage will occur. AMETEK Rotron products are not de s igne d for a nd s hould not be us e d in me dic a l  
life s upport a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.  
5.7BLV99  
2 9  
5 .7 ” (1 4 5 m m ) BLDC Th ru Flo w Blo w e r  
2 5 0 WATT, 1 2 0 VOLT  
Part Numbe r  
Standard Flow  
High Flow  
Unit of  
Me as ure  
Blowe r Data  
116626 M  
116629 E*  
1
116627 M  
116630 E*  
2
116628 M  
116631 E  
3
116644 M  
116647 E  
1
116645 M  
116648 E  
2
116646 M  
116649 E  
3
Stages  
Vacuum, Max. (Sealed Vacuum)  
in. H2O  
mBar  
in. H2O  
mBar  
CFM  
29  
50  
70  
24  
34  
45  
72  
124  
174  
60  
84  
112  
Pressure, Max. (Sealed Pressure)  
Flow Rate, Max. (Open Flow)  
Inlet/Outlet Diameter  
32  
52  
75  
27  
37  
50  
79  
129  
186  
67  
92  
124  
67  
62  
46  
117  
90  
80  
L/sec  
inches  
mm  
32  
29  
22  
55  
42  
38  
1.25  
31.75  
0.74  
18.80  
3.21  
81.53  
1.25  
31.75  
1.65  
41.91  
4.12  
104.65  
1.25  
31.75  
2.5  
1.75  
44.45  
0.76  
19.30  
3.28  
83.31  
1.75  
44.45  
1.88  
47.75  
4.33  
109.98  
1.75  
44.45  
1.75  
44.45  
5.34  
135.64  
Length (Dimension I” above)  
Length (Dimension L” above)  
inches  
mm  
63.50  
5.02  
127.51  
inches  
mm  
Typical Pe rformance Points  
Pre s s ure  
Air Flow  
0 CFM  
10 CFM  
20 CFM  
30 CFM  
40 CFM  
50 CFM  
60 CFM  
70 CFM  
80 CFM  
90 CFM  
100 CFM  
110 CFM  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
32.0  
30.0  
28.1  
24.3  
19.0  
12.5  
6.0  
52.2  
44.5  
42.3  
31.8  
21.8  
11.7  
75.0  
27.0  
26.1  
25.3  
23.3  
23.0  
21.4  
18.0  
16.7  
13.9  
10.2  
6.1  
37.1  
34.1  
31.7  
28.9  
25.9  
21.4  
17.8  
12.4  
5.7  
50.0  
46.3  
42.0  
35.9  
28.6  
21.9  
15.6  
7.5  
52.2  
34.2  
21.5  
8.0  
0
.09  
2.6  
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.  
NOTES:  
Nominal input voltage: 120 Volts AC RMS +/- 10%, 60Hz  
Input current: 5 amps AC RMS maximum  
Temperature: Working Air: 0o C to 50°C, Ambient Air: 0o C to 50°C, Storage Air: -40o C to 85°C  
Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max.  
Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC  
Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection)  
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment.  
5.7/250TFBHV99  
3 0  
5 .7 ” (1 4 5 m m ) BLDC Th ru Flo w Blo w e r  
2 5 0 WATT, 1 2 0 VOLT  
Regulatory Agency Certification: Underwriters Laboratories, Inc. is qualified per UL507 under File E-94403. Canadian Standards Association is qualified per  
C22.2#113 under File LR 43448.  
Miscellaneous: Intake & exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil, or foreign particles.  
Amp housing #350809-1 (to be supplied by customer), mates with post header assembly.  
This doc ume nt is for informa tiona l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The  
pe rformance data on this page de picts typical pe rformance unde r controlle d laboratory conditions , data is corre cte d to 0.075 lb ./ft3 a ir de ns ity (29.92” Hg @ 7F.).  
Ac tua l pe rforma nc e will va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for us e with vola tile , ha za rdous or  
corros ive gas e s . Blowe r hous ings are not s e ale d, s light air/gas le akage will occur. AMETEK Rotron products are not de s igne d for a nd s hould not be us e d in me dic a l  
life s upport a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.  
5.7/250TFBHV99  
3 1  
5 .7 ” (1 4 5 m m ) BLDC Byp a s s Blo w e r  
2 5 0 WATT, 1 2 0 VOLT  
Part Numbe r  
Standard Flow  
High Flow  
116636 M*  
Unit of  
Me as ure  
Blowe r Data  
116634 M*  
116633 M  
116632 M*  
116637 M*  
116635 M  
116640 E*  
1
116639 E  
2
116638 E*  
3
116643 E*  
1
116642 E*  
2
116641 E  
3
Stages  
Vacuum, Max. (Sealed Vacuum)  
in. H2O  
mBar  
in. H2O  
mBar  
CFM  
29  
48  
65  
26  
57.5  
143  
42  
72  
119  
161  
64  
104  
Pressure, Max. (Sealed Pressure)  
Flow Rate, Max. (Open Flow)  
Inlet/Outlet Diameter  
32  
56  
76  
27  
68.0  
169  
46  
79  
139  
188  
67  
114  
68  
63  
49  
115  
110  
80  
L/sec  
inches  
mm  
32  
30  
23  
54  
52  
38  
1.25  
31.75  
0.33  
8.38  
5.08  
129.03  
1.25  
31.75  
1.25  
31.75  
6.35  
161.29  
1.25  
31.75  
2.14  
54.36  
6.89  
175.01  
1.75  
44.45  
0.47  
11.94  
5.22  
132.59  
1.75  
44.45  
1.53  
38.86  
6.27  
159.26  
1.75  
44.45  
2.53  
64.26  
7.28  
184.91  
Length (Dimension I” above)  
Length (Dimension L” above)  
inches  
mm  
inches  
mm  
Typical Pe rformance Points  
Pre s s ure  
Air Flow  
0 CFM  
10 CFM  
20 CFM  
30 CFM  
40 CFM  
50 CFM  
60 CFM  
70 CFM  
80 CFM  
90 CFM  
100 CFM  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
31.8  
28.7  
27.7  
24.7  
20.1  
14.5  
7.3  
56.1  
48.0  
44.3  
38.1  
28.9  
18.2  
4.2  
76.2  
27.1  
25.0  
24.4  
22.9  
21.2  
19.1  
17.2  
15.0  
12.2  
8.0  
48.1  
44.0  
41.6  
37.9  
32.2  
25.8  
20.5  
15.8  
7.1  
46.0  
42.8  
39.2  
34.9  
30.0  
24.3  
16.2  
9.8  
60.3  
44.1  
28.9  
16.1  
5.5  
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.  
NOTES:  
Nominal input voltage: 120 Volts AC RMS +/- 10%, 60Hz  
Input current: 5 amps AC RMS maximum  
Temperature: Working Air: 0o C to 50°C, Ambient Air: 0o C to 50°C, Storage Air: -40o C to 85°C  
Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max.  
Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC  
Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection)  
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment.  
3 2  
5.7/250BHV99  
5 .7 ” (1 4 5 m m ) BLDC Byp a s s Blo w e r  
2 5 0 WATT, 1 2 0 VOLT  
Regulatory Agency Certification: Underwriters Laboratories, Inc. is qualified per UL507 under File E-94403; Canadian Standards Association is qualified per  
C22.2#113 under File LR 43448.  
Miscellaneous: Intake & exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust are free of grease, oil, or foreign particles. Amp  
housing #640250-6 (to be supplied by customer), mates with post header assembly.  
This doc ume nt is for informa tiona l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The  
pe rformance data on this page de picts typical pe rformance unde r controlle d laboratory conditions , data is corre cte d to 0.075 lb ./ft3 a ir de ns ity (29.92” Hg @ 7F.).  
Ac tua l pe rforma nc e will va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for us e with vola tile , ha za rdous or  
corros ive gas e s . Blowe r hous ings are not s e ale d, s light air/gas le akage will occur. AMETEK Rotron products are not de s igne d for a nd s hould not be us e d in me dic a l  
life s upport a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.  
3 3  
5.7/250BHV99  
5 .7 ” (1 4 5 m m ) BLDC Th ru Flo w Blo w e r  
4 0 0 WATT, 2 4 0 VOLT  
Part Numbe r  
Standard Flow  
Unit of  
Me as ure  
Blowe r Data  
117629 E*  
1
117630 E*  
2
Stages  
Vacuum, Max. (Sealed Vacuum)  
in. H2O  
mBar  
in. H2O  
mBar  
CFM  
28  
47  
69  
117  
Pressure, Max. (Sealed Pressure)  
Flow Rate, Max. (Open Flow)  
Length (Dimension I” above)  
Length (Dimension L” above)  
31  
50  
77  
124  
67  
65  
L/sec  
inches  
mm  
32  
31  
.69  
1.60  
40.64  
4.12  
104.65  
17.53  
3.21  
81.53  
inches  
mm  
Typical Pe rformance Points  
Pre s s ure  
Air Flow  
0 CFM  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
31.1  
26.8  
23.8  
20.5  
15.8  
10.0  
4.4  
50.5  
45.4  
40.9  
33.7  
25.3  
16.0  
6.46  
10 CFM  
20 CFM  
30 CFM  
40 CFM  
50 CFM  
60 CFM  
70 CFM  
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.  
NOTES:  
Nominal input voltage: 240 Volts AC RMS +/- 10%, 60Hz  
Input current: 5 amps AC RMS maximum  
Temperature: Working Air: 0o C to 50°C, Ambient Air: 0o C to 50°C, Storage Air: -40o C to 85°C  
Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max.  
Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC  
Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection)  
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment.  
3 4  
5.7/400TFBHV99  
5 .7 ” (1 4 5 m m ) BLDC Th ru Flo w Blo w e r  
4 0 0 WATT, 2 4 0 VOLT  
Regulatory Agency Certification: Underwriters Laboratories, Inc. is qualified per UL507 under File E-94403; Canadian Standards Association is qualified per  
C22.2#113 under File LR 43448.  
Miscellaneous: Intake & exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust are free of grease, oil, or foreign particles. Amp  
housing #350809-1 (to be supplied by customer), mates with post header assembly.  
This doc ume nt is for informa tiona l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The  
pe rformance data on this page de picts typical pe rformance unde r controlle d laboratory conditions , data is corre cte d to 0.075 lb ./ft3 a ir de ns ity (29.92” Hg @ 7F.).  
Ac tua l pe rforma nc e will va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for us e with vola tile , ha za rdous or  
corros ive gas e s . Blowe r hous ings are not s e ale d, s light air/gas le akage will occur. AMETEK Rotron products are not de s igne d for a nd s hould not be us e d in me dic a l  
life s upport a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.  
5.7/400TFBHV99  
3 5  
5 .7 ” (1 4 5 m m ) BLDC Byp a s s Blo w e r  
4 0 0 WATT, 2 4 0 VOLT  
Part Numbe r  
Standard Flow  
High Flow  
Unit of  
Me as ure  
Blowe r Data  
117634 M*  
117640 E*  
1
117633 M  
117639 E  
2
117632 M*  
117638 E*  
3
117637 M*  
117643 E*  
1
117636 M*  
117642 E*  
2
117635 M*  
117641 E*  
3
Stages  
Vacuum, Max. (Sealed Vacuum)  
in. H2O  
mBar  
n. H2O  
mBar  
CFM  
28  
45  
60  
23  
39  
53  
69  
112  
149  
57  
97  
131  
Pressure, Max. (Sealed Pressure)  
Flow Rate, Max. (Open Flow)  
Inlet/Outlet Diameter  
30  
51  
70  
25  
45  
61  
74  
126  
174  
62  
112  
151  
69  
62  
58  
114  
97  
86  
L/sec  
inches  
mm  
33  
29  
27  
54  
46  
41  
1.25  
31.75  
2.53  
64.26  
5.08  
129.03  
1.25  
31.75  
1.25  
31.75  
5.99  
152.15  
1.25  
31.75  
2.14  
54.36  
6.89  
175.01  
1.75  
44.45  
.47  
1.75  
44.45  
1.53  
38.86  
6.27  
159.26  
1.75  
44.45  
2.53  
64.26  
7.28  
184.91  
Length (Dimension I” above)  
Length (Dimension L” above)  
inches  
mm  
11.94  
5.22  
132.59  
inches  
mm  
Typical Pe rformance Points  
Pre s s ure  
Air Flow  
0 CFM  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
30.3  
27.9  
26.2  
23.6  
19.0  
13.3  
7.0  
51.0  
44.2  
41.8  
35.9  
27.8  
16.6  
3.7  
69.9  
24.8  
23.6  
22.6  
21.5  
19.5  
17.9  
16.1  
13.8  
12.0  
8.7  
44.6  
41.0  
39.8  
35.8  
32.0  
28.0  
23.9  
17.9  
12.1  
0
61.5  
55.8  
51.5  
46.0  
40.1  
34.2  
28.2  
19.6  
8.1  
10 CFM  
20 CFM  
30 CFM  
40 CFM  
50 CFM  
60 CFM  
70 CFM  
80 CFM  
90 CFM  
100 CFM  
110 CFM  
59.9  
52.8  
44.1  
32.1  
18.1  
3.7  
6.7  
0
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.  
NOTES:  
Nominal input voltage: 240 Volts AC RMS +/- 10%, 50/60Hz  
Input current: 5 amps AC RMS maximum  
Temperature: Working Air: 0o C to 50°C, Ambient Air: 0o C to 50°C, Storage Air: -40o C to 85°C  
Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max.  
Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC  
Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection)  
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment.  
5.7/400BHV99  
3 6  
5 .7 ” (1 4 5 m m ) BLDC Byp a s s Blo w e r  
4 0 0 WATT, 2 4 0 VOLT  
Regulatory Agency Certification: T.U.V. Rheinland Bauart Certification* is qualified per EN60950 under License No. R0097184.  
Underwriters Laboratories, Inc. Qualified per UL507 under File E-94403. Canadian Standards Association Qualified per C22.2#113 under File LR 43448.  
Miscellaneous: Intake & exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust are free of grease, oil, or foreign particles. Amp  
housing #1-480763-0 (to be supplied by customer), mates with post header assembly.  
*IEC 801 testing has been completed, and specific data can be provided upon request.  
This doc ume nt is for informa tiona l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The  
pe rformance data on this page de picts typical pe rformance unde r controlle d laboratory conditions , data is corre cte d to 0.075 lb ./ft3 a ir de ns ity (29.92” Hg @ 7F.).  
Ac tua l pe rforma nc e will va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for us e with vola tile , ha za rdous or  
corros ive gas e s . Blowe r hous ings are not s e ale d, s light air/gas le akage will occur. AMETEK Rotron products are not de s igne d for a nd s hould not be us e d in me dic a l  
life s upport a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.  
5.7/400BHV99  
3 7  
5 .7 ” (1 4 5 m m ) BLDC Byp a s s Blo w e r  
8 0 0 WATT, 1 2 0 VOLT  
Part Numbe r  
High Flow  
Standard Flow  
Ultra Flow  
Unit of  
Me as ure  
Blowe r Data  
117418 M*  
119102 M*  
119104 M*  
117417 E*  
3
119101 E*  
1
119103 E*  
2
119105 E*  
Stages  
1
26  
Vacuum, Max. (Sealed Vacuum)  
in. H2O  
mBar  
in. H2O  
mBar  
CFM  
106  
41  
71  
263  
102  
176  
64  
Pressure, Max. (Sealed Pressure)  
Flow Rate, Max. (Open Flow)  
Inlet/Outlet Diameter  
115  
44  
76  
29  
285  
109  
188  
72  
67  
161  
119  
242  
L/sec  
inches  
mm  
32  
76  
56  
114  
1.25  
31.75  
2.12  
53.85  
6.87  
174.50  
1.75  
44.45  
.47  
1.75  
44.45  
1.53  
38.86  
6.35  
161.29  
2.75/2.50  
69.85/63.50  
.71  
Length (Dimension I” above)  
Length (Dimension L” above)  
inches  
mm  
11.94  
5.30  
134.62  
18.03  
5.46  
inches  
mm  
138.68  
Typical Pe rformance Points  
Pre s s ure  
Air Flow  
0 CFM  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
115.8  
44.1  
41.8  
39.2  
34.1  
29.0  
23.3  
14.4  
7.0  
76.2  
68.4  
57.2  
43.5  
33.2  
19.8  
0
29.3  
27.5  
26.1  
23.5  
21.6  
17.6  
15.8  
14.1  
11.2  
8.2  
20 CFM  
40 CFM  
60 CFM  
80 CFM  
100 CFM  
120 CFM  
140 CFM  
160 CFM  
180 CFM  
200 CFM  
220 CFM  
240 CFM  
86.6  
54.9  
18.3  
0
5.5  
2.8  
1.2  
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.  
NOTES:  
Nominal input voltage: 120 Volts AC RMS +/- 10%, 60Hz  
Input current: 10 amps AC RMS maximum  
Temperature: Working Air: 0o C to 50°C, Ambient Air: 0o C to 50°C, Storage Air: -40o C to 85°C  
Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max.  
Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC  
Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection)  
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment.  
3 8  
5.7/800BHV99  
5 .7 ” (1 4 5 m m ) BLDC Byp a s s Blo w e r  
8 0 0 WATT, 1 2 0 VOLT  
Regulatory Agency Certification: T.U.V. Rheinland Bauart Certification* is qualified per EN60950 under Licence No. R9571008; Underwriters Laboratories, Inc. is  
qualified per UL507 under File E-94403; Canadian Standards Association is qualified per C22.2#113 under File LR 43448.  
Miscellaneous: Intake & exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil, or foreign particles.  
Amp housing #350810-1(to be supplied by customer), mates with post header assembly.  
This doc ume nt is for informa tiona l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The  
pe rformance data on this page de picts typical pe rformance unde r controlle d laboratory conditions , data is corre cte d to 0.075 lb ./ft3 a ir de ns ity (29.92” Hg @ 7F.).  
Ac tua l pe rforma nc e will va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for us e with vola tile , ha za rdous or  
corros ive gas e s . Blowe r hous ings are not s e ale d, s light air/gas le akage will occur. AMETEK Rotron products are not de s igne d for a nd s hould not be us e d in me dic a l  
life s upport a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.  
3 9  
5.7/800BHV99  
5 .7 ” (1 4 5 m m ) DC Byp a s s Blo w e r  
1 2 0 0 WATT, 2 4 0 VOLT  
Part Numbe r  
High Flow  
Standard Flow  
Ultra Flow  
Unit of  
Me as ure  
Blowe r Data  
117416 M*  
119152 M*  
119154 M*  
117415 E*  
3
119151 E*  
1
119153 E*  
2
119155 E*  
Stages  
1
33  
Vacuum, Max. (Sealed Vacuum)  
in. H2O  
mBar  
135  
50  
91  
335  
124  
226  
82  
Pressure, Max. (Sealed Pressure)  
Flow Rate, Max. (Open Flow)  
Inlet/Outlet Diameter  
in. H O  
144  
54  
97  
39  
2
mBar  
CFM  
L/sec  
inches  
mm  
357  
134  
241  
97  
82  
190  
156  
307  
39  
90  
74  
145  
1.25  
31.75  
2.12  
53.85  
6.87  
174.50  
1.75  
44.45  
.47  
1.75  
44.45  
1.53  
38.86  
6.35  
161.29  
2.75/2.50  
69.85/63.50  
.70  
Length (Dimension I” above)  
Length (Dimension L” above)  
inches  
mm  
11.94  
5.11  
128.77  
17.78  
5.47  
inches  
mm  
138.94  
Typical Pe rformance Points  
Pre s s ure  
Air Flow  
0 CFM  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
in. H2O  
144.3  
54.0  
53.9  
51.1  
47.0  
43.2  
37.0  
29.4  
22.3  
14.2  
97.0  
92.5  
85.8  
75.9  
62.3  
40.5  
32.1  
15.0  
39.2  
38.0  
37.5  
35.3  
33.5  
31.4  
28.0  
25.4  
21.5  
18.5  
16.1  
13.1  
10.0  
7.4  
20 CFM  
129.1  
102.9  
60.8  
40 CFM  
60 CFM  
80 CFM  
10.8  
100 CFM  
120 CFM  
140 CFM  
160 CFM  
180 CFM  
200 CFM  
220 CFM  
240 CFM  
260 CFM  
280 CFM  
300 CFM  
4.3  
1.0  
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.  
NOTES:  
Nominal input voltage: 240 Volts AC RMS +/- 10%, 50/60Hz  
Input current: 5 amps AC RMS maximum  
Temperature: Working Air: 0o C to 50°C, Ambient Air: 0o C to 50°C, Storage Air: -40o C to 85°C  
Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max.  
4 0  
5.7/1200BHV99  
5 .7 ” (1 4 5 m m ) DC Byp a s s Blo w e r  
1 2 0 0 WATT, 2 4 0 VOLT  
NOTES (continue d):  
Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC  
Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection)  
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment.  
Regulatory Agency Certification: T.U.V. Rheinland Bauart Certification* is qualified per EN60950 under License No. 9571008; Underwriters Laboratories, Inc. is  
qualified per UL507 under File E 94403; Canadian Standards Association is qualified per C22.2#113 under File LR 43448.  
Miscellaneous: Intake & exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil, or foreign particles.  
Amp housing #350809-1 (to be supplied by customer), mates with post header assembly.  
*IEC 801 testing has been completed, and specific data can be provided upon request.  
This doc ume nt is for informa tiona l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The  
pe rformance data on this page de picts typical pe rformance unde r controlle d laboratory conditions , data is corre cte d to 0.075 lb ./ft3 a ir de ns ity (29.92” Hg @ 7F.).  
Ac tua l pe rforma nc e will va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for us e with vola tile , ha za rdous or  
corros ive gas e s . Blowe r hous ings are not s e ale d, s light air/gas le akage will occur. AMETEK Rotron products are not de s igne d for a nd s hould not be us e d in me dic a l  
life s upport a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.  
5.7/1200BHV99  
4 1  
5 Am p BLDC Blo w e r Co n t ro lle r  
Blowe r Contolle rs  
48132  
Controlle r Data  
Max Continuous Current  
Input Voltage Range  
Controller PWM Frequency  
Analog Speed Input  
Electrical Hall Spacing  
Waveform  
5 A  
11-52 VDC  
25 kHz  
0-5 VDC  
600 or 1200  
8-Step Trapezoidal  
Yes  
Current Limit Protection  
Rotation  
CW / CCW  
NOTES:  
Temperature: Operating: 0o C to 50°C, Storage Air: -40o C to 85°C  
Speed Control: Electrical speed control is achieved by applying a 0 to 5 VDC signal on J1 Pin 3 with respect to J1 Pin 2. Mechanical speed control is achieved by  
adjusting the potentiometer when J6 is in position 1 to 2.  
Current Control: Trip point is at 5 Amp maximum.  
J1-1 Vin  
J4-1 Motor Phase A  
J4-2 Motor Phase C  
J4-3 Hall - (Gnd)  
J4-4 Hall 1  
J1-2 Vin Return (Gnd)  
J1-3 Analog Speed In  
J4-5 Hall 2  
J4-6 Hall 3  
J4-7 Hall + (+12V)  
J4-8 Motor Phase B  
Caution should be taken. Misplacement of jumper setting will destroy the control.  
Jumper Settings:  
J6 Set to position 1-2 for internal speed adjust.  
Set to position 2-3 for analog speed input voltage.  
J3 Disable or enable to determine forward/reverse rotation.  
J2 Disable for 60° electrical spacing.  
Enable for 120° electrical spacing.  
J5 Set position 1-2 for 16-52 VDC  
Set position 2-3 for 11-16 VDC  
This doc ume nt is for informa tiona l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The  
pe rforma nc e da ta on this pa ge de pic ts typic a l pe rforma nc e unde r c ontrolle d la bora tory c onditions us ing c ons ta nt DC volta ge s . Actual pe rformance will vary  
de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for a nd s hould not be us e d in me dic a l life s upport a pplic a tions .  
AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.  
4 2  
5BC99  
1 0 Am p BLDC Blo w e r Co n t ro lle r  
Blowe r Contolle rs  
48133  
Controlle r Data  
Max Continuous Current  
Input Voltage Range  
Controller PWM Frequency  
Analog Speed Input  
Electrical Hall Spacing  
Waveform  
10 A  
11-52 VDC  
25 kHz  
0-5 VDC  
600 or 1200  
8-Step Trapezoidal  
Yes  
Current Limit Protection  
Rotation  
CW / CCW  
NOTES:  
Temperature: Operating: 0o C to 50°C, Storage Air: -40o C to 85°C  
Speed Control: Electrical speed control is achieved by applying a 0 to 5 VDC signal on J1 Pin 3 with respect to J1 Pin 2. Mechanical speed control is achieved by  
adjusting the potentiometer when J6 is in position 1to 2.  
Current Control: Trip point is at 10 Amp maximum.  
J1-1 Vin  
J4-1 Phase C  
J4-2 Phase B  
J4-3 Phase A  
J4-4 Hall - (Gnd)  
J4-5 Hall + (+12V)  
J4-6 Hall 1  
J1-2 Gnd  
J1-3 Analog Speed In  
J4-7 Hall 2  
J4-8 Hall 3  
Caution should be taken. Misplacement of jumper setting will destroy the control.  
Jumper Settings:  
J6 Set to position 1-2 for internal speed adjust.  
Set to position 2-3 for analog speed input voltage.  
J3 Disable or enable to determine forward/reverse rotation.  
J2 Disable for 60° electrical spacing.  
Enable for 120° electrical spacing.  
J5 Set position 1-2 for 16-52 VDC  
Set position 2-3 for 11-16 VDC  
This doc ume nt is for informa tiona l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The  
pe rforma nc e da ta on this pa ge de pic ts typic a l pe rforma nc e unde r c ontrolle d la bora tory c onditions us ing c ons ta nt DC volta ge s . Actual pe rformance will vary  
de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for a nd s hould not be us e d in me dic a l life s upport a pplic a tions .  
AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.  
4 3  
5BC99  
2 0 Am p BLDC Mo t o r Co n t ro lle r  
Motor Contolle r  
48134  
Controlle r Data  
Max Continuous Current  
Input Voltage Range  
Controller PWM Frequency  
Analog Speed Input  
Electrical Hall Spacing  
Waveform  
20 A  
11-52 VDC  
25 kHz  
0-5 VDC  
600 or 1200  
8-Step Trapezoidal  
Yes  
Current Limit Protection  
Rotation  
CW / CCW  
NOTES:  
Temperature: Operating: 0o C to 50°C, Storage Air: -40o C to 85°C  
Speed Control: Electrical speed control is achieved by applying a 0 to 5 VDC signal on J4 Pin 12 with respect to J4 Pin 7. Mechanical speed control is achieved by  
adjusting the potentiometer when J6 is in position 1 to 2.  
Current Control: Trip point is at 20 Amp maximum.  
J4-6 Brake  
J4-5 Hall +  
J4-4 Hall 3  
J4-3 Hall 2  
J4-2 Hall 1  
J4-1 Gnd  
J4-12 Analog/In  
J4-11 Freq. Out  
J4-10 For./Rev.  
J4-9 Output Enable  
J4-8 Vref  
J1-1 Vin  
J1-2 Phase A  
J1-3 Phase B  
J1-4 Phase C  
J1-5 Ground  
J4-7 Ground  
Caution should be taken. Misplacement of jumper setting will destroy the control.  
Jumper Settings:  
J5 Set to position 1-2 for 16-52 VDC operation.  
Set to position 2-3 for 11-16 VDC operation.  
J6 Set to position 1-2 for internal speed adjust.  
Set to position 2-3 for analog speed input voltage.  
J3 Disable or enable to determine forward/reverse rotation.  
J2 Disable for 60° electrical spacing.  
Enable for 120° electrical spacing.  
This doc ume nt is for informa tiona l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The  
pe rforma nc e da ta on this pa ge de pic ts typic a l pe rforma nc e unde r c ontrolle d la bora tory c onditions us ing c ons ta nt DC volta ge s . Actual pe rformance will vary  
de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for a nd s hould not be us e d in me dic a l life s upport a pplic a tions .  
AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.  
20MC99  
4 4  
BLDC Mo t o r/Blo w e r Co n t ro lle r Nu m b e rs  
Motor/Blowe r  
Part  
Controlle r  
Part  
Numbe rs  
48134  
48134  
48134  
48134  
48134  
48134  
48134  
48134  
48134  
48134  
48134  
48134  
48134  
48134  
48134  
48134  
48134  
48134  
48134  
48134  
48133  
48133  
48133  
N/A  
Mating Cable  
From Controlle r  
to Blowe r/Motor  
N/A  
Ca ble  
mm  
inc he s  
In p u t  
Powe r Cable  
N/A  
Num be rs  
119272  
119275  
119000  
119001  
119002  
119003  
119004  
119005  
119006  
119007  
119008  
119050  
119051  
119052  
119053  
119054  
119055  
119056  
119057  
119058  
119375  
119380  
119383  
119381  
119382  
119384  
119385  
119378  
119379  
119396  
119397  
116521  
116522  
116450  
117007**  
117011**  
119319**  
119317**  
39831  
39817  
457.2±12.7  
457.2 ±12.7  
609.6±12.7  
304.8±12.7  
152.4±12.7  
304.8±3.0  
457.2±3.0  
609.6±3.0  
145.0±3.0  
292.1±3.0  
241.3±3.0  
304.8±12.7  
457.2±12.7  
609.6±12.7  
368.3±12.7  
304.8±12.7  
457.2±12.7  
609.6±12.7  
18.00±.50  
18.00±.50  
24.00±.50  
12.00+.50  
6.00±.50  
N/A  
N/A  
39817-1  
39817-2  
39851  
39831 or 39817*  
39831 or 39817*  
39831 or 39817*  
39831 or 39817*  
39831 or 39817*  
39831 or 39817*  
39831 or 39817*  
39831 or 39817*  
39831 or 39817*  
39831 or 39817*  
39831 or 39817*  
39831 or 39817*  
39831 or 39817*  
39831 or 39817*  
39831 or 39817*  
39831 or 39817*  
39831 or 39817*  
39831 or 39817*  
39851  
N/A  
N/A  
N/A  
39851-1  
39851-2  
39851-3  
39685  
12.00±.12  
18.00±.12  
24.00±.12  
5.71±.12  
N/A  
N/A  
N/A  
N/A  
39685-1  
39685-2  
39685-3  
39685-4  
39685-5  
39773  
11.50±.12  
9.50±.12  
N/A  
N/A  
12.00±.50  
18.00±.50  
24.00±.50  
14.50±.50  
12.00±.50  
18.00±.50  
24.00±.50  
N/A  
N/A  
N/A  
N/A  
39773-1  
39773-2  
39773-3  
N/A  
N/A  
N/A  
N/A  
N/A  
39773  
39773  
39773  
39773  
39773  
39773  
39773  
39773  
39773  
N/A  
39851  
39851  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
48134  
48134  
48133  
48133  
48133  
48132  
48132  
48132  
48132  
N/A  
N/A  
N/A  
N/A  
39773  
39773  
39773  
39773  
39773  
39773  
39773  
N/A  
N/A  
39685  
39685  
39685  
39685  
*
Cable 39831 transfers hall signals from the motor to the controller. Cable 39817 does the same, but also provides cabling for analog input, tach output,  
braking, forward/reverse, enable/disable, and voltage reference of a nominal 6.25 VDC at a maximum of 10 mAmp.  
** Earlier versions of the 5.0" Minijammer blower.  
MBCP99  
4 5  
PLEASE COMPLETE THIS FORM AND FAX IT TO (330) 678-8227,  
ATTENTION: ROTRON MARKETING DEPARTMENT  
DATE  
COMPANY  
ADDRESS  
CITY  
STATE  
FAX  
ZIP  
NAME  
TITLE  
DEPT.  
TELEPHONE  
Complete applicable side for additional information.  
Blo w e r S izin g  
Mo t o r S izin g  
Purpose of product which motor is to  
be incorporated in  
Purpose of product which blower is to  
be incorporated in  
Describe general operation  
Describe general operation  
Estimated annual requirements  
Estimated annual requirements  
Power Supply  
VDC  
Other  
RPM  
Power Supply  
VDC  
VAC  
CFM  
In. H2O  
Speed Requirements  
To  
Air Flow Requirements  
Pressure Requirements  
To  
To  
Maximum Continuous Performace Requirement  
Speed  
Torque  
Power  
RPM  
Oz. In.  
HP  
Standard Operating Point:  
Pressure or Vacuum  
In. H2O, Flow  
CFM  
Surrounding Temperature:  
Dimension, Max.:  
Diameter  
o
o
Min.  
F
Max.  
F
Inches,  
Length  
Max.  
Inches  
Humidity  
Surrounding Temperature:  
Agency Requirements:  
ISO9001 UL  
o
o
Min.  
F
F
TUV  
CSA  
Other  
Humidity  
Expected Life Hours  
Expected Life Hours  
Production Delivery Date  
Expected Price Range  
Production Delivery Date  
Expected Price Range  
If Replacement  
If Replacement  
Current Manufacturer  
Current Manufacturer  
Model  
Model  
4 6  
Throughout our catalog, you will find terminology  
used for air moving selection and product sizing.  
Below are a few of the key terms:  
Flow  
Specific Gravity  
Volume Rate/Time  
• AMETEK charts are in SCFM, m3/min, or L/S  
SCFM = Standard Cubic Feet Per Minute  
(American)  
• Density Ratio Relative to Air  
• Standard Air SG = 1.0  
• Methane SG = 0.55  
• Air density = 0.075 lb/cubic foot  
• M3/min = Cubic Meters Per Minute (Metric)  
• L/sec = Liters Per Second (Metric)  
• 1 m3/min = 35.3 SCFM  
Velocity  
• Distance/Time or Flow/Area  
• FPM = Feet Per Minute (American)  
• M/min = Meters Per Minute (Metric)  
• 1 L/sec = 2.119 SCFM  
• See Standard Engineering Conversions for  
other flows on pg. 44  
• See Standard Engineering Conversion Chart  
for other velocities on pg. 44  
Pressure Drop/Back Pressure/Impedance  
Pressure  
• Force/Area  
• Friction causes air to slow down and lost  
energy is measured in pressure drop terms  
Typical pressure drop areas include piping,  
elbows, accessories and system  
• AMETEK charts are in In. H2O (IWG), PSIG,  
MM of Water, IHG, or mbar  
• IWG = Inches of Water Gauge (American)  
PSIG = Pounds Per Square Inch Gauge  
(American)  
• Each fixed system has a fixed system  
impedance caused by a single or multiple  
pressure drop points  
• mm of Water = Millimeter of Water Gauge  
(Metric)  
• Changing the system impedance will cause  
the blowers work point to change  
• IHG = Inches of Mercury Gauge (American)  
• mbar = Millibar Gauge (Metric)  
• PSIA = Pounds Per Square Inch Absolute  
(American)  
• 27.7 IWG = 1 PSIG  
• 703.58 MM of Water = 1 PSIG  
• 2.036 IHG = 1 PSIG  
• 0.069 Bars = 69 mbar = 1 PSIG  
Standard Atmosphere = 0 PSIG = 14.7 PSIA  
• See Basic Fan Laws Chart for correcting  
pressure due to speed or density changes  
Density  
• Weight/Volume  
• Standard Air = 0.075 lb/cubic foot  
4 7  
AE99  
Standard Engineering Conversions  
MULTIPLY  
BY  
76.0  
29.92  
406.8348  
10,333  
1.013 x 105  
14.70  
TO OBTAIN  
MULTIPLY  
Kgs ./Cubic Meter  
Kilometers  
Kilowa tts  
Kilowa tts  
Kilowa tts  
BY  
0.06243  
3281  
56.92  
737.6  
1.341  
14.34  
3415  
TO OBTAIN  
Pounds /Cubic Foot  
Feet  
Britis h Thermal Units /Min.  
Foot-Pounds /Sec.  
Hors e p owe r  
Kg.-Calories /Min.  
Britis h Thermal Units  
Atmos pheres  
Atmos pheres  
Atmos pheres  
Atmos pheres  
Atmos pheres  
Atmos pheres  
Atmos pheres  
Cms . of Mercury  
Inches of Mercury  
Inches of Water  
Kgs ./Sq. Meter  
Pascals  
Pounds/Sq. Inch  
Torrs  
Kilowa tts  
Kilowa tt-Hours  
760  
Bars  
Bars  
Bars  
Bars  
0.9869  
1. x 105  
1.020 x 104  
14.50  
0.2520  
777.5  
1054  
107.5  
2.928 x 10–4  
Atmos pheres  
Liters  
Liters  
Liters  
Liters  
Liters/Minute  
Log 10  
Log N or Ln N  
103  
61.02  
10–3  
.2642  
.0353  
2.303  
0.4343  
Cubic Centimeters  
Cubic Inches  
Cubic Meters  
Gallons  
Cubic Feet/Minute  
LogEN or Ln N  
Log 10N  
Dynes /Sq. Cm.  
Kgs ./Square Meter  
Pounds/Sq. Inch  
Kilogra m-Ca lorie s  
Foot-P ound s  
J oules  
Kilogram-Meters  
Kilowa tt-Hours  
Britis h Thermal Units  
Britis h Thermal Units  
Britis h Thermal Units  
Britis h Thermal Units  
Britis h Thermal Units  
N
Me te rs  
Me te rs  
Me te rs  
Me te rs  
Me te rs  
Miles  
Miles  
Miles  
100  
Ce ntime te rs  
Feet  
Inches  
Kilometers  
Millime te rs  
Feet  
Kilometers  
Yards  
Inches of Water  
Inches of Mercury  
Kgs ./Square Cm.  
Pounds/Square Inch  
3.2808  
39.37  
10–3  
103  
5280  
1.6093  
1760  
.4019  
0.0394  
1.3595–3  
0.01934  
Centimeters of Mercury  
Centimeters of Mercury  
Centimeters of Mercury  
Centimeters of Mercury  
Centimeters /Second  
Centimeters /Second  
Cubic Centimeters  
Cubic Centimeters  
Cubic Centimeters  
Cubic Centimeters  
Cubic Feet  
0.01316  
0.0372  
136.0  
0.1934  
1.969  
Atmos pheres  
Inches of Water  
Kgs ./Square Meter  
Pounds/Sq. Inch  
Feet/Minute  
Meters /Minute  
Cubic Feet  
Cubic Inches  
Cubic Meters  
Liters  
Cubic Cms .  
Cubic Inches  
Cubic Meters  
Cubic Yards  
0.6  
3.531 x 10–5  
6.102 x 10–2  
10-6  
Millibars  
Mms . of Mercury  
Mms . of Mercury  
Mms . of Mercury  
10-3  
2.832 x 104  
1728  
0.02832  
0.03704  
28.32  
Newton Meters  
.7376  
Pound-Force-Foot  
Cubic Feet  
Cubic Feet  
Cubic Feet  
Cubic Feet  
Ounce - Force - Inch  
Ounce - Force - Inch  
Ounce - Force - Inch  
0.706  
7.06 x 10–3  
5.21 x 10–3  
Newton - Centimeter  
Newton - Meter  
Pound - Force - Foot  
Liters  
Pascals  
Pints (Liq.)  
Pints (U.S. liquid)  
Pints (U.S. liquid)  
Pounds  
Pounds  
Pounds  
Pounds of Carbon to CO2  
Pounds of Water  
Pounds of Water  
Pounds of Water  
.004  
Inches of Water  
Cubic Inches  
Cubic Centimeters  
Ounces (U.S. fluid)  
Dynes  
Cubic Feet/Minute  
Cubic Feet/Minute  
Cubic Feet/Minute  
Cubic Feet/Minute  
Cubic Feet/Minute  
Cubic Feet/Minute  
Cubic Inches  
Cubic Inches  
Cubic Inches  
Cubic Meters  
Cubic Meters  
472.0  
Cubic Cms ./Sec.  
Cubic Meters /Hour  
Cubic Meters/Minute  
Liters/Minute  
Liters /Second  
Lbs . of Water/Min.  
Cubic Centimeters  
Cubic Feet  
Cubic Meters  
Cubic Centimeters  
Cubic Feet  
Cubic Inches  
Cubic Feet/Minute  
Cubic Feet/Minute  
28.87  
473,179  
16  
444,823  
453.6  
16  
14,544  
27.68  
0.1198  
1.6992  
.02832  
28.32  
0.4720  
62.4  
Grams  
Ounces  
16.39  
5.787 x 10–4  
1.639 x 10–5  
105  
Britis h Thermal Units (mean)  
Cubic Inches  
Gallons  
35.31  
61,023  
.5885  
Evaporated at 212O  
Pounds /Cubic Foot  
Pounds /Cubic Foot  
Pounds-Force-Foot  
Pounds/Square Inch  
Pounds/Square Inch  
Pounds/Square Inch  
Pounds/Square Inch  
Pounds/Square Inch  
Pounds/Square Inch  
F
970.3  
16.02  
4.882  
1.3558  
0.06804  
27.7  
2.036  
703.1  
6.895 x 103  
51.715  
1.973 x 105  
1.076 x 10–3  
0.1550  
Britis h Thermal Units  
Kgs ./Cubic Meter  
Kgs ./Square Meter  
Newton Meters  
Atmos pheres  
Inches of Water  
Cubic Meters  
Cubic Meters/Hour  
Cubic Meters/Minute  
35.3107  
Feet  
Feet  
Feet  
Feet  
30.48  
12  
0.3048  
1/3  
Ce ntime te rs  
Inches  
Me te rs  
Inches of Mercury  
Kgs ./Square Meter  
Pascals  
Yards  
Feet of Air  
(1 atmos phere 60O F)  
5.30 x 10–4  
Pounds/Square Inch  
Millimeters of Mercury at 0O  
C
Gallons  
Grams /Cu. Cm.  
3.785  
62.43  
Liters  
Pounds /Cubic Foot  
Square Centimeters  
Square Centimeters  
Square Centimeters  
Square Feet  
Square Feet  
Square Inches  
Square Inches  
Square Inches  
Square Inches  
Circular Mils  
Square Feet  
Hors e p owe r  
Hors e p owe r  
Hors e p owe r  
Hors e p owe r  
42.44  
33,000  
10.70  
745.7  
2547  
Britis h Thermal Units /Min.  
Foot-Pounds /Min.  
Kg. Calories /Min.  
Watts  
Square Inches  
Square Centimeters  
Square Meters  
Circular Mils  
Square Centimeters  
Square Feet  
929.0  
0.09290  
1.273 x 106  
6.452  
6.944 x 10–3  
106  
Hors epower-Hours  
Britis h Thermal Units  
Inches  
Inches  
2.540  
103  
Ce ntime te rs  
Mils  
Square Mils  
Inches of Mercury  
Inches of Mercury  
Inches of Mercury  
Inches of Mercury  
Inches of Mercury  
Inches of Water  
Inches of Water  
Inches of Water  
Inches of Water  
Inches of Water  
Inches of Water  
Inches of Water  
0.03342  
13.60  
345.3  
Atmos pheres  
Inches of Water  
Kgs ./Square Meter  
Mms . of Mercury  
Pounds/Square In.  
Atmos pheres  
Inches of Mercury  
Kgs ./Square Meter  
Millibars  
Square Inches  
645.2  
Square Millimeters  
Square Feet  
Square Yards  
Square Feet  
Square Kilometers  
Square Kilometers  
Square Meters  
Square Meters  
Temp. (OC) +273  
Temp. (OC) +17.8  
Temp. (OF) +460  
Temp. (OF) -32  
10.76 x 106  
1.196 x 106  
10.764  
25.40  
0.4912  
0.002458  
0.07355  
25.40  
2.4884  
248.8  
1.196  
Square Yards  
1
1.8  
1
Abs . Temp. (OC)  
Temp. (OF)  
Abs . Temp. (OF)  
Temp. (OC)  
5/9  
Pascals  
Pounds /Square Ft.  
Pounds/Square In.  
Watts  
Watts  
Watts  
Watts  
Watts  
Wa tts -Hours  
Wa tts -Hours  
0.05692  
107  
44.26  
Britis h Thermal Units /Min.  
Ergs /Se c ond  
Foot-Pounds /Min.  
Hors e p owe r  
Kg.-Calories /Min.  
Britis h Thermal Units  
Hors e p owe r/Hours  
5.204  
0.03613  
1.341 x 10–3  
0.01434  
3.415  
1.341 x 10–3  
4 8  
AE99  
Density Correction Chart  
4 9  
AE99  
Physical Laws for Blower Applications  
In the following formulae these symbols are used:  
Standard Air”-Air at 68O F (absolute temperature 528O) and  
29.92” Hg. (barometric pressure at sea level). The density of  
such air is 0.075 lbs./cu. ft. and the specific volume is 13.29  
cu. ft./lb. The specific gravity is 1.0.  
P-Pressure in pounds per square inch (PSI) or inches of  
mercury column (inches Hg)  
CFM-Volume in cubic feet per minute  
RPM-Speed in revolutions per minute  
D-Density in pounds per cubic foot (lbs./cu. ft.)  
H-Height of air or gas column (ft.)  
The outlet pressure of a blower depends on the condition of  
the air or gas at the inlet. The inlet condition is influenced by:  
a-Specific gravity (the ratio of density of the gas to density  
of standard air)  
SG-Specific Gravity (ratio of density of gas to the density  
of air)  
b-Altitude (location of blower)  
c-Temperature of inlet air  
Basic Fan Laws Chart  
VARIABLE  
VOLUME  
PRESSURE  
HORSEPOWER  
WHEN SPEED CHANGES Varies DIRECT with Speed Ratio Varies with SQUARE of Speed Ratio Varies with CUBE of Speed Ratio  
2
3
RPM2  
( )  
RPM1  
RPM2  
RPM2  
CFM2 = CFM1  
P2 = P1  
HP2 = HP1  
( )  
( )  
RPM1  
RPM1  
WHEN DENSITY CHANGES  
Does Not Change  
Varies DIRECT with Density Ratio  
Varies DIRECT with Density Ratio  
D2  
D2  
P2 = P1  
HP2 = HP  
( )  
1 ( )  
D1  
D1  
Volume  
The Volume changes in direct ratio to the speed.  
V = Original Volume (1000 CFM)  
1
Example – A blower is operating at 3500 RPM and delivering  
1000 CFM. If the speed is reduced to 3000 RPM, what is the  
new volume?  
V = New Volume  
2
RPM1 = Original Speed (3500 RPM)  
RPM2 = New Speed (3000 RPM)  
1
1
RPM2  
3000  
V = V  
= 1000 x  
= 1000 x .857 = 857 CFM  
( )  
(3500 )  
2
1
RPM1  
Pressure  
Pressure (barometric) varies in direct proportion  
to altitude.  
Let: V = Volume of standard air (1000 CFM)  
1
Example – A blower is to operate at an elevation of 6000 feet  
and is to deliver 3 PSI pressure. What pressure (standard air)  
blower is required?  
V = Volume of thinner air  
2
Hg1 = Barometric pressure sea level (29.92)  
Hg2 = Barometric pressure 6000’ (23.98)  
29.92  
Pressure = 3 x  
= 3.75 or 3 3/4 PSI  
Hg1  
Hg2  
29.92  
23.98  
23.98  
V = V1 x  
= 1000 x  
= 1248 CFM  
2
If it is desired to determine what pressure a 3 PSI (standard  
air) blower will deliver at 6000 feet –  
The pressure changes as the square of the  
speed ratio.  
23.98  
Pressure = 3 x  
= 2.4 or about 2 1/2 PSI  
29.92  
Example – A blower is operating at a speed of 3500 RPM and  
delivering air at 5.0 PSI pressure. If the speed is reduced to  
3000 RPM, what is the new pressure?  
When a blower is to operate at a high altitude it is frequently  
specified that the blower be capable of handling a given  
volume of “standard air”. It is then necessary to determine  
the equivalent volume of air at the higher altitude.  
P1 = Original Pressure (5 PSI)  
P2 = New Pressure  
Example – A blower is to operate 6000 feet altitude and is to  
handle 1000 CFM of standard air. What is the CFM of air the  
blower must handle at 6000 feet altitude?  
RPM1 = Original Speed (3500 RPM)  
RPM2 = New Speed (3000 RPM)  
RPM2  
2
2 = 5 x .735 = 3.68 PSI  
3000  
P2 = P1  
= 5 x  
( ) (3500 )  
RPM1  
5 0  
AE99  
The Air Density varies in inverse proportion to the  
absolute temperature.  
Example – A blower is to handle 200O F air at 3 PSI pressure.  
What pressure (standard air) blower is required?  
Pressure varies in direct proportion to the density.  
Example – A 3 PSI (standard air) blower is to be used to  
handle gas having a specific gravity of 0.5. What pressure  
does the blower create when handling the gas?  
Let: P1 = Pressure hot air (3 PSI)  
Let: Pa  
Pg  
=
=
=
Air pressure (3 PSI)  
Gas pressure  
Specific gravity of gas (0.5)  
P2 = Pressure standard air  
SG  
AT1 = Absolute temperature hot air (200+460=660O F)  
AT2 = Absolute temperature standard air (68+460=528O F)  
Pg = Pa x SG = 3 x .5 = 1.5 PSI  
AT1  
AT2  
660  
528  
If we are required to handle a gas having a specific gravity of  
0.5 at 1.5 PSI pressure, we can determine the standard air  
pressure blower as follows:  
P2 = P1 x  
= 3 x  
= 3.75 or 3 3/4 PSI  
Pg  
1.5  
.5  
A blower is capable of delivering 3 PSI pressure with  
standard air. What pressure will it develop handling 200O F  
inlet air?  
Let: Pa =  
=
= 3 PSI  
SG  
AT2  
AT1  
528  
660  
P1 = P2 x  
= 3 x  
= 2.4 or about 2 1/2 PSI  
Horsepower  
The horsepower changes as the cube of the speed  
ratio.  
Horsepower vs. Specific Gravity & Ratio of Density.  
The horsepower varies in direct proportion to the specific  
gravity (ratio of density of gas to density of air).  
Example – A blower is operating at a speed of 3500 RPM and  
requiring 50 horsepower. If the speed is reduced to 3000  
RPM, what is the new required horsepower?  
Example – A standard air blower requires a 10 HP motor.  
What horsepower is required when this blower is to handle a  
gas whose specific gravity is 0.5?  
HP1 = Original Horsepower (50)  
HP2 = New Horsepower  
HP = 10 x 0.5 = 5 horsepower  
RPM1 = Original Speed (3500 RPM)  
RPM2 = New Speed (3000 RPM)  
It is possible that several of the above modifications may be  
required on one installation. Therefore, it may be necessary  
to use various combinations of these formulae.  
RPM2  
3000  
3
3
HP = HP x  
= 50 x  
= 50 x .630 = 31.5 horsepower  
( ) ( )  
2
1
0
350  
RPM1  
5 1  
AE99  
AMETEK Global Operations  
AMETEK Aerospace  
S ENS ORS /MONITORING S YS TEMS www.ametek.com/aerospace  
50 Fordham Road • Wilmington, MA 01887 U.S.A.  
AMETEK elektromotory s.r.o.  
ul. Beloveska 318 • Nachod 54701 Czech Republic  
Tel:420-441-23877 • Fax:420-441-23111  
Tel:978-988-4101 • Fax:978-988-4944  
Shaded pole induction motors for heating and ventilation, thru-flow and bypass vacuum cleaner  
motors, and universal series drive motors.  
Sensors and interconnects for engines, airframes, launch vehicles and satellites, including fuel  
flow, temperature, speed, pressure and liquid level. Monitoring systems, including vibration.  
Digital bus adapters.  
AMETEK GmbH  
Weilimdorfer Str. 47 • D-70825 Korntal-Munchingen Germany  
Tel:+49-711-838-7876 • Fax:+49-711-838-7862  
Sales for Electromechanical Group—Europe.  
AVIONICS • www.ametek.com/aerospace  
900 Clymer Avenue • Sellersville, PA 18960 U.S.A.  
Tel:215-257-6531 • Fax:215-257-1888  
Data acquisition and interface units for avionics systems. Engine indicating systems. RVSM  
altimeters. Fuel/hydraulic/water quality measuring systems.  
AMETEK Italia S.r.l.  
GULTON-STATHAM Produc ts www.gultonstatham.com  
1644 Whittier Avenue • Costa Mesa, CA 92627 U.S.A.  
CIARAMELLA • www.ametek.it  
Via De Barzi • Robecco Sul Naviglio 20087 Italy  
Tel:949-642-2400 • Fax:949-642-9490  
Tel:+39-02-946931 • Fax:+39-02-94970518  
Pressure, proximity and position sensors for aircraft, engines, airborne and land-based launch  
vehicles, satellites, and industrial applications angle of attack sensors and stall warning  
computers. Mud density and smart recording transmitters for oil and gas drilling.  
Universal series drive motors for outdoor power equipment, small household appliances, floor  
care and personal care products, and special applications.  
VACUUM Produc ts www.ametek.it  
SERVICE OPERATIONS  
Via De Gasperi 18/A Ripalta Cremasca 26010 Italy  
Tel:+39-0373-2101 • Fax:+39-0373-268200  
Thru-flow and bypass vacuum motors for household,commercial,industrial canister,and upright  
vacuum cleaners.  
Distribution and Warehousing Operation www.ametek.com/aerospace  
Wilmington Service Center • 50 Fordham Road • Wilmington, MA 01887 U.S.A.  
Tel:Warehouse 978-988-4100,Service:978-988-4729  
Fax: Warehouse: 978-988-4720, Service: 978-988-4408  
Distribution of aerospace and industrial instruments, sensors, and spare parts. Maintenance of  
instruments manufactured by AMETEK Aerospace. FAA Repair Station No. A8PR-221J.  
AMETEK Lamb Electric  
www.ameteklamb.com  
Seattle Support Center www.ametek.com/aerospace  
4560 150th Avenue NE • Redmond, WA 98052 U.S.A.  
Tel:425-881-1172 • Fax:425-881-7292  
Maintenance of instruments manufactured by AMETEK Aerospace. FAA Repair Station No.  
HU6R600N.  
627 Lake Street • Kent, OH 44240 U.S.A.  
Tel:330-673-3451 • Fax:330-673-8994  
Motors and motor-blower systems for industrial, commercial, and household vacuum cleaners,  
ACUSTEK® motors, related floor-care equipment, and other applications such as paint sprayers,  
material transport, spas, and outdoor power equipment, requiring a vacuum, pressure, or drive  
source.  
AMETEK Chemical Products  
AMETEK Motors Shanghai Co. Ltd.  
#1 AMETEK Road • Jiu Ting Economic Development Zone, Shanghai 201615 China  
Tel:86-21-5763-2408 • Fax:86-21-5763-2411  
HAVEG • www.ametek.com/haveg E-mail:haveg@ametek.com  
900 Greenbank Road • Wilmington, DE 19808 U.S.A.  
Tel:302-995-0400,800-441-7777 • Fax:302-995-0491  
SILTEMP®,ULTISIL®,HAVEGLAS™ high-thermal-resistance fabrics for welding blankets,  
furnace curtains, and insulation. FLEXSIL® molten metal filters. Corrosion-resistant HAVEG®  
tanks, towers, valves, and piping. Fluoropolymer tubing and Heat Exchangers of TEFLON*.  
Fractional horsepower electric motors and blowers for Asian and  
worldwide markets.  
AMETEK Power and Industrial Products  
www.ametek.com/power • E-mail:power.industrial@ametek.com  
50 Fordham Road • Wilmington, MA 01887 U.S.A.  
WESTCHESTER PLASTICS • www.ametek-westchesterplas.com  
Green Acres Industrial Park • Nesquehoning, PA 18240 U.S.A  
Tel:570-645-2191 • Fax:570-645-8564  
Custom color compounding of elastomers, blends, reactive modifiers and other thermoplastic  
resins. Small scale pilot runs through commercial production runs. Custom color matching  
services.  
Tel:978-988-4101 • Fax:978-988-4179  
Temperature,pressure,speed and flame sensors and interconnects for land,marine,and utility  
gas turbines and industrial boilers and burners.Gulton-Statham pressure,mud density,and  
smart recording transmitters for oil and gas drilling.  
AMETEK Dixson  
AMETEK Precision Instruments Europe GmbH  
Rudolf-Diesel-Strasse 16 • D-40670 Meerbusch Germany  
Tel:+49-2159-9136-0 • Fax:+49-2159-9136-39  
DIXSON • www.ametekdixson.com  
287 27 Road • Grand Junction, CO 81503 U.S.A.  
Tel:888-302-0639,970-242-8863 • Fax:970-245-6267  
OEM instrumentation and data collection units for the heavy duty vehicular market. Industrial  
bargraph panel meters for commercial and nuclear applications. Process controls and  
controllers for the fast-food preparation industry.  
Sales for Electronic Instruments Group—Europe and for AMETEK Rotron  
Technical Motor Division—Europe.  
AMETEK Precision Instruments France SARL  
3 Avenue des Coudriers, Z.A. de l’Observatoire • Montigny Le Bretonneux 78180 France  
Tel:33 1 30 64 89 70 • Fax:33 1 30 64 89 79  
NATIONAL CONTROLS CORP. (NCC) • www.nationalcontrols.com  
1725 Western Drive • West Chicago, IL 60185 U.S.A.  
Tel:630-231-5900,800-323-2593 • Fax:630-231-1377  
Time delay relays, temperature monitors and controls, solid state relays and voltage monitors,  
liquid level controls,and dust collectors/controls for the food industry,refrigeration,HVAC, test  
chambers, and other industrial applications.  
Sales for Electronic Instruments Group—France and for AMETEK Rotron  
Technical Motor Division—France.  
AMETEK Precision Instruments (UK) Ltd.  
www.ametek.co.uk E-mail: sales@ametek.co.uk  
PANALARM • www. panalarm.com  
1725 Western Drive • West Chicago, IL 60185 U.S.A.  
Tel:847-675-2500 • Fax:847-675-3011  
2 Queens Drive, Kings Norton Business Centre • Kings Norton, Birmingham B30 3HH England  
Tel:44-121-246-2260 • Fax:44-121-246-2270  
Sales for Electronic Instruments Group—United Kingdom and Ireland.  
Sales for Panalarm annunciator products—Europe, Middle East, Africa,  
Pakistan and India. Sales for Thermox products—United Kingdom and Ireland.  
Process monitoring annunciators, control room graphic displays, and high-speed event  
recorders for petrochemical refineries, electrical generation and distribution, airport and train  
event monitoring, water and wastewater treatment plants.  
AMETEK Corporate Office  
www.ametek.com  
Station Square • Paoli, PA 19301 U.S.A.  
Tel:610-647-2121,800-473-1286 • Fax:610-296-3412  
5 2  
AMETEK Process & Analytical Instruments  
AMETEK Specialty Metal Products  
METAL STRIP a nd SPECIALTY WIRE • www.ametekmetals.com  
21Toelles Road • Wallingford, CT 06492 U.S.A.  
PROCESS INSTRUMENTS • www.ametekpi.com  
455 Corporate Blvd. • Newark, DE 19702 U.S.A.  
Tel:302-456-4400,800-222-6789 • Fax:302-456-4444  
Tel:203-265-6731,800-233-2266 • Fax:203-265-6407  
Continuous on-line photometric and trace moisture analyzers used for advanced process control,  
emissions monitoring, and product quality improvement. Markets include chemical  
manufacturing,semiconductor,and special packaging.  
Wrought powder metallurgy for engineered custom metal strip and wire including SEALVAR®  
iron-nickel cobalt, custom shaped wire, metal matrix composites including HIVOL™ silicon  
carbide aluminum, and fully dense components (FDC). FDC include vacuum sputtering targets for  
thin film deposits through the ISOFORM™ technology using the Pneumatic Isostatic Forging  
process. Product applications include satellites, land-and sea-based radar systems, computers,  
chip mounting, heat sinks, and reflective coatings.  
THERMOX Bus ine s s Unit • www.thermox.com  
150 Freeport Road • Pittsburgh, PA 15238 U.S.A.  
Tel:412-828-9040 • Fax:412-826-0399  
THERMOX®oxygen analyzers for flue gas and industrial gas applications, combustion analyzers  
for measuring oxygen and combustibles in a single analyzer,CO monitors,and premix gas  
analyzers.  
AMETEK Shanghai (SPL)  
Room 16B5, Harvest Bldg. • #585 Long Hua Xi Road, Shanghai 200232 China  
Tel:86-21-6428-4067,86-21-6469-8814Fax:86-21-6487-5329  
Representative Office of AMETEK Singapore Pte. Ltd.  
WESTERN RESEARCH • www.ametekpi.com  
8 Manning Close N.E. • Calgary, Alberta T2E7N5 Canada  
Tel:403-235-8400 • Fax:403-248-3550  
AMETEK Singapore Pte. Ltd.  
10 Ang Mo Kio Street 65 • #05-12 TECHPOINT 569059 Singapore  
Tel:65-484-2388 • Fax:65-481-6588 E-mail:aspl@ametek.com.sg  
Sales for all AMETEK products—Pacific Rim.  
Sulfur Recovery Unit process monitoring, control, and emissions analyzers to measure air  
demand, SO , H S, NO concentrations. Dewpoint monitors, tunable diode laser spectrometers,  
2
2
x
and temperature monitors.  
AMETEK Rotron  
AMETEK Test and Calibration Instruments  
COMMERCIAL BRUSHLESS Produc ts • www.ametektmd.com  
627 Lake Street • Kent, OH 44240 U.S.A.  
CHATILLON® Fo rc e Me a s u re m e n t P ro d u c t s  
8600 Somerset Drive • Largo, FL 33773 U.S.A.  
www.chatillon.com  
Tel:330-673-3452 • Fax:330-678-8227  
Brushless DC motors, WINDJAMMER® and MINIJAMMER® motor-blowers, and low-voltage  
controllers for computers, business machines, medical devices, pumps and compressors,  
industrial equipment, and such mass-transit vehicles as transit buses, rail cars, and  
locomotives.  
Tel:727-536-7831,800-527-9999 • Fax:727-539-6882  
Force gauges, universal testing machines, and material test instruments,  
automated testing software, gripping fixtures and accessories.  
AMETEK De nm a rk A/S • www.ametek.com/tci  
Gydevang 32-34, PO Box 30 • DK-3450 Allerod Denmark  
Tel:45-4816-8000 • Fax:45-4816-8080  
JOFRA temperature and pressure calibrators and FRODE PEDERSEN sensors  
(also markets other AMETEK instrument products throughout Europe).  
MIL-AERO Produc ts www.rotron.com  
9 Hasbrouck Lane • Woodstock, NY 12498 U.S.A.  
Tel:914-679-2401 • Fax:914-679-7080  
AC and brushless DC fans and blowers, heat exchanger and blower systems, fault detection  
devices, and electronic power conversion devices for the military and aerospace markets.  
Repair of products manufactured byAMETEK RotronTechnical Motor Division. FAA Repair  
Station No. AN1R014K.  
LLOYD INSTRUMENTS™ Ma te ria l Te s ting Produc ts  
www.lloyd-instruments.co.uk  
12 Barnes Wallis Road, Segensworth East • Fareham, Hampshire PO15 5TT England  
Tel:44-1489-574221 • Fax:44-1489-885118  
INDUSTRIAL Produc ts a nd BIOFILTRATION Produc ts www.rotron.com  
75 North Street • Saugerties, NY 12477 U.S.A.  
Materials testing machines, force gauges and test stands, melt flow indexers, friction testers, melt  
viscometer, density column,plastic film impact testers,and heat distortion equipment (HDT/VICAT).  
Tel:914-246-3401 • Fax:914-246-3802  
IndustrialProducts:Regenerative air blowers for pressure and vacuum applications  
up to 1800 SCFM and 10 PSIG servicing the Industrial, Environmental, Instrumentation, &  
Telecommunication markets.Typical applications include solution agitation & aeration,pneumatic  
conveying, part hold-down and pick up, part blow off, gas & fume extraction, and process gas  
handling. BiofiltrationProducts:Patented modular Biofiltration systems that remove noxious  
odors and vapors from gaseous exhaust and air supply systems in commercial, municipal  
wastewater,and industrial applications.  
MANSFIELD & GREEN Produc ts www.ametek.com/tci  
8600 Somerset Drive • Largo, FL 33773 U.S.A.  
Tel:727-536-7831,800-527-9999 • Fax:727-539-6882  
Electronic tachometers and stroboscopes, force and torque gauges, deadweight testers, pressure  
calibrators, diaphragm seals, and air/noise monitoring instruments.  
AMETEK U.S. Gauge  
AMETEK Sensor Technology  
U.S. GAUGE Produc ts www.ametekusg.com  
PATRIOT Produc ts www.patriotsensors.com  
900 Clymer Ave. • Sellersville, PA 18960 U.S.A.  
Tel:215-257-6531 • Fax:215-257-3058  
Pressure and temperature gauges for industrial use, process industries, and OEM applications.  
Pressure gauges for compressed gas, welding, and medical applications. Solid front pressure  
gauges and diaphragm seals for chemical, petrochemical, and other process industries. Hunter  
Spring NEG’ATOR® and SPIR’ATOR® constant force springs and spring powered retracting reels.  
1080 N. Crooks Road • Clawson, MI 48017-1097 U.S.A.  
Tel:248-435-0700 • Fax:248-435-8120  
Position sensors including rotary cam limit switches, programmable limit switches, linear  
position sensors and rotary encoders; programmable controller bus cards including ultra-high  
speed programmable limit switches and electronic encoders for linear and rotary inputs;  
stamping press automation including shut height monitors; specialty products including cable and  
hose carrier systems. Point level sensor products including conductivity sensors, conductivity  
relays and magnetic probes; continuous level sensors including magnetostrictive probes for tank  
gauging and leak monitoring.  
PMT Produc ts www.ametekusg.com  
820 Pennsylvania Blvd. • Feasterville, PA 19053 U.S.A.  
Tel:215-355-6900,888-625-5895 • Fax:215-355-2937  
Pressure transducers and transmitters for industrial markets, pressure gauges, switches,  
transmitters, displays and cylinder sales for UHP semiconductor manufacturing markets, level  
measurement systems, pneumatic controllers, and gas energy content (BTU) meters.  
DREXELBROOK Produc ts www.drexelbrook.com  
205 Kieth Valley Road • Horsham, PA 19044 U.S.A.  
Tel:215 674-1234• Fax:215 674-2731  
RF and ultrasonic level sensors in a broad range of packages for chemical,petrochemical,water,  
waste water,food,beverage and pharmaceutical monitoring; continuous and point level sensors;  
IS and EX applications; line powered, low voltage, 4-20mA loop powered, HART and other  
networked outputs. Clarifier and sludge blanket sensor systems for wastewater applications.  
Level sensors for aerospace applications.  
AMEKAI Taiwan Co., Ltd.  
2-Floor, No. 214Alley 1 • Lane 138, Chang-An Street • Pan-Chiao,TaipeiTaiwan  
Tel:886-2-2954-1765 • Fax:886-2-2951-3443  
Joint venture withTaiwanese partner.General industrial use mechanical  
pressure gauges for Asian and worldwide markets.  
AMETEK Specialty Metal Products  
AMEKAI Meters (XIAMEN) Co., Ltd.  
1-2 Floors, Chuang Xin Bldg.,Torch High Technology Industrial Zone  
Innovate City, Xiamen, Fujian 361006 China  
CLAD METALS a nd METAL POWDERS • www.ametekmetals.com  
Route 519 • Eighty Four, PA 15330 U.S.A.  
Tel:724-225-8400 • Fax:724-225-6622  
Stainless steel and nickel clad alloys used in high-quality cookware, sterilizers and chemical  
processing equipment. Stainless steel, cobalt, and nickel alloy metal powders for powder  
Tel:86-592-603-0565 • Fax:86-592-603-0570  
Joint venture with Chinese partner.General industrial use mechanical  
pressure gauges for Asian and worldwide markets.  
metallurgy,hardfacing,metal injection molding, polymer filtration,and plastic compounding.  
5 3  
Co n t a c t In fo rm a t io n  
ROTRON  
Technical Products  
627 Lake Street  
Kent, OH 44240  
Main Tel: (330) 673-3452  
Fax: (330) 678-8227  
www.ametektmd.com  
e-mail: info@ametektmd.com  
AMETEK GmbH  
Weilimorder Str. 47  
70825 Korntal-Munchingen  
Germany  
Main Tel: 49-711-838-7876  
Fax: 49-711-838-7862  
Dis t rib u t o rs  
Allied Electronics  
1-800-433-5700  
www.allied.avnet.com  
Grainger  
1-800-323-0620  
www.grainger.com  
54  
AMETEK, Inc.  
AMETEK is a leading global manufacturer of electrical and electromechanical products for niche markets.  
Listed on the New York Stock Exchange (AME) since 1930, AMETEK’s annual sales are approaching $1  
billion. Operations are in North America, Europe, and Asia, with about one-third of sales to markets outside  
the United States. AMETEK is serving its customers with investments in new products, global and market  
expansion, strategic acquisitions, and operational excellence. The Company’s operating groups are  
Electronic Instruments and Electromechanical.  
Rotron  
The Electromechanical Group (EMG) is one of the world’s largest producers of high-speed electric motor  
products for original equipment manufacturers (OEMs). In business since 1915, EMG is using its core  
competencies to enhance its worldwide presence. A business unit of AMETEK EMG, Rotron has facilities  
in California, New York, North Carolina, and Ohio. Rotron serves the military, aerospace, medical,  
transportation, office equipment, industrial, and environmental markets worldwide. Rotron supports its  
customers with more than 650 employees that are organized in three business segments:  
Technical Products  
• Military & Aerospace Products  
• Industrial Products  
Technical Products  
Rotron’s standard product lines of brushless DC motors, blowers, and controllers offer a wide range of  
application demands. Brushless DC motors and blowers are an ideal choice for such varied applications  
as medical instruments, robotics, pumps, compressors, office equipment, fans, machine tools, tape drives,  
or any other precise rotary motion/air delivery applications. If there is a need for a product with unique  
performance, mounting environment, or agency requirements, Rotron can supply the solution.  
ROTRON  
Technical Products  
627 Lake Street, Kent, Ohio 44240  
Telephone: 330-673-3452 • Fax: 330-678-8227 • www.ametektmd.com  
©2000, by AMETEK, Inc.  
5M200N (140044)  

相关型号:

117418-01

145MM120V 800W BLDC BLOWER
ETC

1174280000

Electronics housings, CH20M black, Lateral element, Width: 12.5 mm
WEIDMULLER

1174WHI

LAMPHOLDER BC PERPENDICULAR
ETC

1175-900-E0001G

Connector Accessory
WINCHESTER

1175LP15A0550

1.175 GHz Low Pass Filter
JOHANSON

1175LP15A0550E

1.175 GHz Low Pass Filter
JOHANSON

1175LP15A0550EPB

1.175 GHz Low Pass Filter
JOHANSON

1175LP15A0550S

1.175 GHz Low Pass Filter
JOHANSON

1175LP15A0550SPB

1.175 GHz Low Pass Filter
JOHANSON

117629-02

145 MM 240V 400W TF BLOWER
ETC

117630-06

145 MM 240V 400W TF BLOWER
ETC

117632-02

145MM240V 400W BLDC BLOWER
ETC