Table of Contents
Introduction ............................................... 1, 2, 3
BLDC Motors
1.7” (43mm) diameter ........................................... 4, 5
2.5” (64mm) diameter ........................................... 6, 7
3.0” (79mm) diameter ........................................... 8, 9
3.55” (90mm) diameter ....................................... 10, 11
3.9” (99mm) diameter ....................................... 12, 13
5.25” (133mm) diameter ..................................... 14, 15
Low Voltage Blowers (BLDC)
2.9” (74mm)...................................................... 16, 17
3.0” (76mm)....................................................... 18, 19
3.3” (84mm)....................................................... 20, 21
4.5” (114mm)..................................................... 22, 23
5.0” (127mm) MINIJAMMER®............................. 24, 25
5.1” (130mm)..................................................... 26, 27
5.7” (145mm) WINDJAMMER®........................... 28, 29
High Voltage Blowers (BLDC)
WINDJAMMER®
5.7” (145mm) Thru Flow/250 Watt/120VAC ..... 30, 31
5.7” (145mm) Bypass/250 Watt/120VAC .......... 32, 33
5.7” (145mm) Thru Flow//400 Watt/240 VAC ... 34, 35
5.7” (145mm) Bypass/400 Watt/240VAC .......... 36, 37
5.7” (145mm) Bypass/800 Watt/120VAC .......... 38, 39
5.7” (145mm) Bypass/1200 Watt/240VAC ........ 40, 41
Controllers (BLDC)
5
Amp Motor/Blower .......................................... 42
10 Amp Motor/Blower .......................................... 43
20 Amp Motor ...................................................... 44
BLDC Motor/Blower
Controller Part Numbers ................................ 45
Blower/Motor Sizing Sheet ............................ 46
Application Engineering
Basics .................................................47, 48, 49, 50, 51
AMETEK Global Locations........................ 52, 53
Contact Information ....................................... 54
Th e AMETEK Ele c t ro m e c h a n ic a l Gro u p (EMG). . .
is one of the world’s largest producers of high-speed electric motor products for original equipment
manufacturers (OEMs). In business since 1915, EMG uses its core competencies in motion and air
movement products as engineered solutions for application-specific needs. A unit of AMETEK EMG,
Rotron offers Brushless DC motor-, blower-, and controller-based solutions.
The standard product lines of Rotron Technical Products cover a wide range of application demands.
If there is a need for a product with unique performance, mounting, environment or agency require-
ments, Rotron can supply the solution. Whether a customer needs a standard or special design,
Rotron has the solution for your application. AMETEK offers economies of scale that only can be
accomplished by a company that produces more than 23 million motor products per year. With
multiplant capability and flexibility, Rotron is positioned to support our customers’ global programs.
AMETEK Brushless DC Motors and Blowers are an ideal choice for such varied applications as medi-
cal instruments, robotics, pumps, compressors, business equipment, fans, machine tools, tape
drives, or any other precise rotary motion/air delivery applications.
1
INTRO99
Bru s h le s s DC Mo t o rs . . .
offer precise control for a wide range of applications. Rotron standard motor designs offer
maximum controllable performance, coupled with the reliability of brushless technology in a com-
pact cost effective package. First introduced in 1988, the AMETEK brushless DC motor product line
has continually expanded into one of the largest mixes of fractional horsepower motor products in
the industry.
Mo t o r S e le c t io n . . .
is made easy with the wide variety of standard products available from AMETEK. Six different motor
families are available in standard configurations. These include 1.7” (43mm), 2.5” (64mm), 3.0”
(76mm), 3.55” (90mm), 3.9” (99mm), and 5.25” (133mm) diameter motors, with constant torque which
range from 5.75 oz. in. (4.06 Ncm) to 832 oz. in. (5.87 Nm) and horsepower ratings of .014 to 1.75.
Voltage options range from 12VDC to 74VDC. The table below provides a summary of the motor
products, operating voltages, speed and torque ranges sorted by motor diameter. Use this chart to
compare the AMETEK products to the application needs. Detailed motor information is provided on
the individual product sheets.
BLDC MOTORS
Motor Diameter
Operating Voltage (DC)
Controller Input
12, 24, 36
Speed Range (RPM)
at Nom. Continuous Torque
0 - 3,000
Torque Range (oz. in.)
Maximum Continuous
5.75 - 11
1.7” (43mm)
2.5” (64mm)
3.0” (76mm)
3.55” (90mm)
3.9” (99mm)
5.25” (133mm)
12, 24, 36
0 - 5,000
14 - 69
13.8, 24, 27.6
12, 24, 36
0 - 4,930
19.7 - 55
0 - 4,300
22 - 132
12. 13.8, 27.6, 74
27, 27.6, 74
0 - 4,500
28 - 100
0 - 4,055
192 - 832
Mo t o r Co n t ro lle rs
All of the AMETEK BLDC Motors require a controller to operate. The controllers require a DC
input which is processed into phase drive signals. The 1.7” (43mm) and 3.0” (76mm) motors
are available with integrated controllers. All other motors require an external controller. Con-
troller details and compatibility to the different motor products are supplied in the controller
section of the catalog.
2
INTRO99
Bru s h le s s DC Blo w e rs . . .
offer variable (speed) output for a wide range of vacuum or pressure applications. Standard blower
designs offer brushless DC motor drives coupled to high efficiency fan systems in a compact, cost
effective package. Standard models are available in a wide range of input voltages, including 12, 24,
28, and 36VDC. A complete product line of brushless DC blowers that accepts line voltage input
(120VAC and 240VAC) also is available. AMETEK brushless DC blowers are not designed for, and
should not be used in, life sustaining applications. AMETEK brushless DC blowers are not 100%
sealed and therefore should not be used with flammable or hazardous gases.
Blo w e r S e le c t io n . . .
offers a wide variety of standard products available from AMETEK. Thirteen different blower families
are available in standard configurations. These include seven low voltage and six high voltage
products. The low voltage products provide outputs which range from 0 to 28” H20 (pressure) at
flows of 0 to 45 CFM. The high voltage products provide outputs which range from 0 to 162” H20
(pressure) at flows of 0 to 275 CFM.
LOW VOLTAGE PRODUCTS
Blower Diameter
2.9” (74mm)
3” (76mm)
Operating Voltage (DC)
12, 24
CFM Range
0-22
0-18
0-7
In. H 0 (Pressure)
In. H 0 (Vacuum)
2
2
0-3
-
12, 24
0-10
0-27
0-28
0-24
0-25
0-28
-
3.3” (84mm)
4.5” (114mm)
5” (127mm)
12, 24
-
12, 24
0-9
-
12, 24
0-45
0-15
0-39
-
-
5.1” (130mm)
5.7” (145mm)
12, 24
12, 24, 36
0-28
HIGH VOLTAGE BYPASS PRODUCTS
Blower Diameter
5.7” (145mm)
5.7” (145mm)
5.7” (145mm)
5.7” (145mm)
Operating Voltage (AC)
CFM Range
0-115
In. H 0 (Pressure)
In. H 0 (Vacuum)
2
2
120 (250 Watt)
120 (800 Watt)
240 (400 Watt)
240 (1200 Watt)
0-76
0-115
0-144
0-162
0-65
0-106
0-135
0-118
0-242
0-115
0-275
HIGH VOLTAGE THRU-FLOW PRODUCTS
Blower Diameter
5.7” (145mm)
5.7” (145mm)
Operating Voltage (AC)
CFM Range
0-117
In. H 0 (Pressure)
In. H 0 (Vacuum)
2
2
120 (250 Watt)
240 (400 Watt)
0-75
0-50
0-70
0-47
0-67
3
INTRO99
1 .7 ” (4 3 m m ) Dia m e t e r, 8 P o le , Bru s h le s s DC Mo t o r
2 4 VDC
Unit of
Me as ure
RPM
Part Numbe rs
Motor Da ta
119272*
4388
.16
119275*
No Load Speed, Nominal
No Load Current, Nominal
Stall Torque, Theoretical
4308
.18
amps
oz.-in.
12.7
8.96
5.75
4.06
51.3
36.20
11
Ncm
Continuous Torque
oz.-in.
Ncm
7.77
Speed @ Torque, Nominal
Current @ Torque, Nominal
Continuous Power, Max.
Torque Constant
RPM
2425
1.0
3000
1.75
24
amps
watts out
oz.-in. /amp
Ncm/amp
V/kRPM
V/rad/sec
millisecond
millisecond
oz.-in./(watt^.5)
Ncm/(watt^.5)
oz.-in.sec2
Ncm-sec^2
ohms
10
7.39
5.21
7.53
5.31
Voltage Constant
5.47
5.57
0.052
.273
.202
0.053
.339
Electrical Time Constant
Mechanical Time Constant
Motor Constant
.134
2.37
4.12
1.67
2.91
Rotor Inertia
8.00 x 10-6
0.0565
9.74
2.66
3.5
1.60 x 10-5
0.0113
3.34
1.13
Terminal Resistance
Terminal Inductance
Thermal Resistance
Length (“L” above)
millihenry
ºC/W
1.90
inches
1.864
47.35
.51
2.614
66.40
.78
mm
Weight
lb.
kg
0.23
0.35
Shaft Length (“S” above)
inches
.75
1.00
25.40
mm
19.05
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.
NOTES
* Motors require brushless motor controller for operation, refer to the controller section (page 45) for applicable controllers.
* Motor design characteristics are based on an operating environment of 25ºC.
* Nominal and maximum performance figures are based on a winding temperature of 105ºC.
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.
* AMETEK RTMD products are not designed for and should not be used in medical life support applications.
* AMETEK reserves the right to revise its products without notification.
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK RTMD Marketing and Sales.
4
1.7M99
1 .7 ” (4 3 m m ) Dia m e t e r, 8 P o le , Bru s h le s s DC Mo t o r
2 4 VDC
This doc ume nt is for informa l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The
pe rforma nc e da ta on this pa ge de pic ts typic a l pe rforma nc e unde r c ontrolle d la bora tory c onditions us ing AMETEK BLDC motor c ontrolle rs . Ac tua l pe rforma nc e will
va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for a nd s hould not be us e d in me dic a l life s upport
a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.
1.7M99
5
2 .5 ” (6 4 m m ) Dia m e t e r, 8 P o le , Bru s h le s s DC Mo t o r
2 4 VDC
Unit of
Me as ure
RPM
Part Numbe rs
Motor Da ta
119000*
5947
1.14
142
119001
5389
1.07
179
119002
4233
0.93
191
119003*
119004
4636
0.98
282
119005
4019
0.91
294
119006
3575
0.85
302
119007
119008*
2879
0.77
No Load Speed, Nominal
No Load Current, Nominal
Stall Torque, Theoretical
5468
1.08
267
3191
0.81
amps
oz.-in.
311
319
Ncm
100
127
135
189
199
208
213
219
225
Continuous Torque
oz.-in.
14
21
27
34
41
48
55
62
69
Ncm
10
15
19
24
29
34
39
44
49
Speed @ Torque, Nominal
Current @ Torque, Nominal
Continuous Power, Max.
Torque Constant
RPM
4928
3.7
4234
4.6
3286
4.5
4228
6.8
3455
6.8
3074
6.8
2645
6.9
2290
6.9
2002
6.9
amps
watts out
oz.-in. /amp
Ncm/amp
V/kRPM
V/rad/sec
millisecond
millisecond
oz.-in./(watt^.5)
Ncm/(watt^.5)
oz.-in.sec2
Ncm-sec^2
ohms
51
66
66
106
105
109
108
105
102
5.46
3.85
4.04
0.0385
0.838
5.236
6.8
6.02
4.25
4.45
0.0425
0.886
4.129
8.1
7.67
5.42
5.67
0.0542
0.937
4.080
9.3
5.94
4.19
4.39
0.0419
0.904
3.775
10.1
7.1
7.00
4.94
5.18
0.0494
0.938
4.006
11.1
7.9
8.08
5.70
5.97
0.0570
0.965
3.668
12.1
8.6
9.08
6.41
6.71
0.0641
0.986
3.217
12.9
9.1
10.17
7.18
11.27
7.96
Voltage Constant
7.52
8.34
0.0718
1.004
3.258
13.8
0.0796
1.019
3.021
14.7
Electrical Time Constant
Mechanical Time Constant
Motor Constant
4.8
5.7
6.6
9.8
10.4
Rotor Inertia
0.0017
0.0012
0.648
0.543
1.26
2.335
59.31
1.15
0.52
.750
19.05
0.0019
0.0013
0.557
0.493
1.22
2.335
59.31
1.25
0.57
.750
19.05
0.0025
0.0018
0.678
0.635
1.19
2.835
72.01
1.60
0.73
.750
19.05
0.0027
0.0019
0.348
0.314
1.15
2.835
72.01
1.75
0.79
.750
19.05
0.0035
0.0025
0.396
0.372
1.11
3.585
91.06
2.15
0.98
1.500
38.1
0.0038
0.0027
0.444
0.429
1.08
3.585
91.06
2.25
1.02
1.500
38.1
0.0038
0.0027
0.493
0.486
1.04
3.585
91.06
2.30
1.04
1.500
38.1
0.0044
0.0031
0.541
0.543
1.00
0.0046
0.0032
0.589
0.601
0.96
Terminal Resistance
Terminal Inductance
Thermal Resistance
Length (“L” above)
millihenry
ºC/W
inches
4.085
103.76
2.70
4.085
103.76
2.80
mm
Weight
lb.
kg
1.22
1.27
Shaft Length (“S” above)
inches
1.875
47.63
1.875
47.63
mm
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.
NOTES
* Motors require brushless motor controller for operation, refer to the controller section ( page 45) for applicable controllers.
* Motor design characteristics are based on an operating environment of 25ºC.
* Nominal and maximum performance figures are based on a winding temperature of 105ºC.
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.
* AMETEK RTMD products are not designed for and should not be used in medical life support applications.
* AMETEK reserves the right to revise its products without notification.
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK RTMD Marketing and Sales.
2.5M99
6
2 .5 ” (6 4 m m ) Dia m e t e r, 8 P o le , Bru s h le s s DC Mo t o r
2 4 VDC
This doc ume nt is for informa l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The
pe rforma nc e da ta on this pa ge de pic ts typic a l pe rforma nc e unde r c ontrolle d la bora tory c onditions us ing AMETEK BLDC motor c ontrolle rs . Ac tua l pe rforma nc e will
va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for a nd s hould not be us e d in me dic a l life s upport
a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.
2.5M99
7
3 .0 ” (7 9 m m ) Dia m e t e r, 4 P o le , Bru s h le s s DC Mo t o r
This drawing is a general outline. For a more detailed drawing please contact AMETEK Rotron.
Unit of
Part Numbe rs
Motor Da ta
Me as ure
Volts DC
RPM
150004
13.8
*150007
E-11488
24.0
5400
1.5
Voltage Input
27.6
5510
1
No Load Speed, Nominal
No Load Current, Nominal
Stall Torque, Theoretical
3770
0.75
169
amps
oz.-in.
Ncm
1300
915
1298
917
119
Continuous Torque
oz.-in.
Ncm
19.7
13.9
43
55
30
39
Speed @ Torque, Nominal
Current @ Torque, Nominal
Continuous Power
RPM
2927
4.6
4930
6.9
4400
9.9
amps
watts
43
157
181
Torque Constant
oz.-in. /amp
Ncm/amp
V/kRPM
V/rad/sec
inches
mm
4.90
3.46
7.43
6.00
4.24
4.44
0.0424
4.27
108.46
TBD
5.25
Voltage Constant
3.66
5
0.035
3.25
82.63
1.7
0.048
3.77
Length (“L” above)
Weight
95.76
3
lb.
kg
0.776
.3152
8.0060
1.87
47.50
Internal
1.359
.281
Shaft Diameter (“D” above)
Shaft Length (“S” above)
inches
mm
.281
7.137
7.137
3.50/3.50
88.90/88.90
External
48129-03
inches
mm
1.37
34.75
Drive Electronics
Internal or External
External
48129-11
Electronic Drive Part Number
*Part Number 150007 has a dual shaft.
NOTES
* Motor design characteristics are based on an operating environment of 25ºC.
* Nominal and maximum performance figures are based on a winding temperature of 105ºC.
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.
* AMETEK Rotron products are not designed for and should not be used in medical life support applications.
* AMETEK reserves the right to revise its products without notification.
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales.
3.0M99
8
3 .0 ” (7 9 m m ) Dia m e t e r, 4 P o le , Bru s h le s s DC Mo t o r
Exte rnal Drive Part Numbe r
4 8 1 2 9 -0 3
Exte rnal Drive Part Numbe r
4 8 1 2 9 -1 1
This doc ume nt is for informa l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The
pe rformance data on this page de picts typical pe rformance unde r controlle d laboratory conditions us ing AMETEK BLDC motor contro lle rs . Ac tua l pe rforma nc e will
va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for a nd s hould not be us e d in me dic a l life s upport
a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.
3.0M99
9
3 .5 5 ” (9 0 m m ) Dia m e t e r, 8 P o le , Bru s h le s s DC Mo t o r
2 4 VDC
Unit of
Me as ure
RPM
Part Numbe rs
Motor Da ta
119050*
4319
1.48
119051
5259
1.74
119052
4067
1.41
119053*
119054
2838
1.07
119055
2543
0.99
119056
2281
0.92
119057
119058*
1856
0.80
No Load Speed, Nominal
No Load Current, Nominal
Stall Torque, Theoretical
3434
1.24
2021
0.85
amps
oz.-in.
284
375
428
453
496
505
518
541
549
Ncm
201
265
302
320
350
357
366
382
387
Continuous Torque
oz.-in.
22
36
49
63
77
91
105
119
132
Ncm
16
25
35
44
54
64
74
84
93
Speed @ Torque, Nominal
Current @ Torque, Nominal
Continuous Power, Max.
Torque Constant
RPM
3715
4.4
4342
7.6
3265
7.6
2641
7.9
2174
7.8
1864
8.1
1605
8.3
1377
8.3
1214
8.4
amps
watts out
oz.-in. /amp
Ncm/amp
V/kRPM
V/rad/sec
millisecond
millisecond
oz.-in./(watt^.5)
Ncm/(watt^.5)
oz.-in.sec2
Ncm-sec^2
ohms
60
116
118
123
124
126
125
121
119
7.52
6.17
7.98
9.45
6.68
11.44
8.08
12.77
9.02
14.23
10.05
10.52
0.1005
1.331
9.413
21.4
16.06
11.34
11.88
0.1134
1.358
9.313
23.1
17.49
12.35
12.93
0.1235
1.382
8.754
24.1
5.31
4.36
5.64
Voltage Constant
5.56
4.56
5.90
6.99
8.46
9.44
0.0531
1.055
14.713
11.5
0.0436
1.052
13.065
12.5
0.0564
1.140
12.005
15.0
0.0667
1.205
10.293
16.6
0.0808
1.256
11.253
19.0
0.0901
1.297
10.283
20.1
Electrical Time Constant
Mechanical Time Constant
Motor Constant
8.1
8.9
10.6
11.7
13.4
14.2
15.1
16.3
17.0
Rotor Inertia
0.0138
0.0097
0.425
0.449
1.21
0.0145
0.0102
0.242
0.255
1.19
0.0191
0.0135
0.283
0.322
1.17
0.0201
0.0142
0.323
0.389
1.15
0.0286
0.0202
0.363
0.457
1.13
0.0293
0.0207
0.404
0.524
1.11
0.0303
0.0214
0.444
0.591
1.09
0.0350
0.0247
0.485
0.658
1.06
0.0360
0.0254
0.525
0.726
1.04
Terminal Resistance
Terminal Inductance
Thermal Resistance
Length (“L” above)
millihenry
ºC/W
inches
2.500
63.50
2.10
2.500
63.50
2.25
3.000
76.20
2.80
3.000
76.20
3.00
3.750
95.25
3.75
3.750
95.25
4.00
3.750
95.25
4.20
4.250
107.95
4.70
4.250
107.95
4.85
mm
Weight
lb.
kg
0.95
1.02
1.27
1.36
1.70
1.81
1.90
2.13
2.20
Shaft Length (“S” above)
inches
.750
19.05
.750
19.05
.750
.750
19.05
1.500
38.10
1.500
38.10
1.500
38.10
1.875
47.63
1.875
47.63
mm
19.05
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.
NOTES
* Motors require brushless motor controller for operation, refer to the controller section (page 45) for applicable controllers.
* Motor design characteristics are based on an operating environment of 25ºC.
* Nominal and maximum performance figures are based on a winding temperature of 105ºC.
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.
* AMETEK RTMD products are not designed for and should not be used in medical life support applications.
* AMETEK reserves the right to revise its products without notification.
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK RTMD Marketing and Sales.
3.55M99
1 0
3 .5 5 ” (9 0 m m ) Dia m e t e r, 8 P o le , Bru s h le s s DC Mo t o r
2 4 VDC
This doc ume nt is for informa l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The
pe rformance data on this page de picts typical pe rformance unde r controlle d laboratory conditions us ing AMETEK BLDC motor contro lle rs . Ac tua l pe rforma nc e will
va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK RTMD produc ts a re not de s igne d for a nd s hould not be us e d in me dic a l life s upport
a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.
1 1
3.55M99
3 .9 ” (9 9 m m ) Dia m e t e r, 4 P o le , Bru s h le s s DC Mo t o r
This drawing is a general outline. For a more detailed drawing please contact AMETEK Rotron.
Unit of
Part Numbe rs
Motor Da ta
Me as ure
Volts DC
RPM
071033
12
071070
071031
071145
27.6
3000
0.5
Voltage Input
13.8
3750
2.5
74
No Load Speed, Nominal
No Load Current, Nominal
Stall Torque, Theoretical
6700
1
3700
0.22
334
amps
oz.-in.
Ncm
72
210
453
51
148
236
320
Continuous Torque
oz.-in.
Ncm
28
60
85
100
20
42
60
71
Speed @ Torque, Nominal
Current @ Torque, Nominal
Continuous Power
RPM
4500
14
2527
14.3
113
2700
3.2
2100
8
amps
watts
94
171
155
Torque Constant
oz.-in. /amp
Ncm/amp
V/kRPM
V/rad/sec
inches
mm
2.42
1.71
1.79
0.0171
5.33
135.38
6.4
4.98
3.51
3.68
0.0351
6.08
154.43
7.3
27.04
19.10
20
12.44
8.79
9.20
0.0879
7.68
195.07
9.3
Voltage Constant
Length (“L” above)
Weight
0.1910
6.68
169.67
8.0
lb.
kg
2.9
3.3
3.6
4.2
Shaft Diameter (“D” above)
Shaft Length (“S” above)
Drive Electronics
inches
mm
.2495
6.337
.83
.6250
15.8750
1.00
25.40
Internal
.312
7.925
1.65
41.91
Internal
.4997
12.6924
2.25
57.15
Internal
inches
mm
21.08
Internal
NOTES
* Motor design characteristics are based on an operating environment of 25ºC.
* Nominal and maximum performance figures are based on a winding temperature of 105ºC.
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.
* AMETEK Rotron products are not designed for and should not be used in medical life support applications.
* AMETEK reserves the right to revise its products without notification.
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales.
3.9M99
1 2
3 .9 ” (9 9 m m ) Dia m e t e r, 4 P o le , Bru s h le s s DC Mo t o r
This doc ume nt is for informa l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The
pe rformance data on this page de picts typical pe rformance unde r controlle d laboratory conditions us ing AMETEK BLDC motor contro lle rs . Ac tua l pe rforma nc e will
va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for a nd s hould not be us e d in me dic a l life s upport
a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.
3.9M99
1 3
5 .2 5 ” (1 3 3 m m ) Dia m e t e r, 4 P o le , Bru s h le s s DC Mo t o r
This drawing is a general outline. For a more detailed drawing please contact AMETEK Rotron.
Unit of
Part Numbe rs
Motor Da ta
Me as ure
Volts DC
RPM
528512
27.6
071087
27
071190
524647
74
*524506
27
Voltage Input
27
1765
0.7
No Load Speed, Nominal
No Load Current, Nominal
Stall Torque, Theoretical
4055
1.6
1935
0.8
2565
0.62
2000
amps
2.5
oz.-in.
Ncm
2403
1697
192
4380
3094
368
6400
4519
560
18000
12707
720
15383
10862
832
Continuous Torque
oz.-in.
Ncm
136
260
395
508
587
Speed @ Torque, Nominal
Current @ Torque, Nominal
Continuous Power
RPM
3250
23
1573
20
1445
27.5
2253
18.5
1750
amps
46.0
watts
467
433
605
1214
39.01
27.55
28.85
0.2755
8.91
1090
Torque Constant
oz.-in. /amp
Ncm/amp
V/kRPM
V/rad/sec
inches
mm
9.20
6.21
6.81
0.0621
6.76
171.70
18
18.85
13.31
13.94
0.1331
7.86
20.68
14.61
15.30
0.1461
10.36
263.14
23
18.25
12.89
13.50
0.1289
10.09
256.29
27
Voltage Constant
Length (“L” above)
Weight
199.64
20
226.31
24
lb.
kg
8.2
9.1
10.4
10.9
12.2
Shaft Diameter (“D” above)
Shaft Length (“S” above)
inches
mm
.3747
9.5174
1.00
25.40
Internal
.6250
15.8750
2.06
.7497
19.0424
3.25
.7497
19.0424
7.09
.6250
15.8750
2.05/2.05
52.07/52.07
External
inches
mm
52.32
Internal
82.55
Internal
180.09
External
Drive Electronics
Internal or External
Drive Electronics Part Number
N/A
N/A
N/A
524731
524508
*Part Number 524506 has a dual shaft.
NOTES
* Motor design characteristics are based on an operating environment of 25ºC.
* Nominal and maximum performance figures are based on a winding temperature of 105ºC.
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.
* AMETEK RTMD products are not designed for and should not be used in medical life support applications.
* AMETEK reserves the right to revise its products without notification.
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK RTMD Marketing and Sales.
5.25M99
1 4
5 .2 5 ” (1 3 3 m m ) Dia m e t e r, 4 P o le , Bru s h le s s DC Mo t o r
Exte rnal Drive Part Numbe r
5 2 4 7 3 1
5 2 4 5 0 8
This doc ume nt is for informa l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The
pe rforma nc e da ta on this pa ge de pic ts typic a l pe rforma nc e unde r c ontrolle d la bora tory c onditions us ing AMETEK BLDC motor c ontrolle rs . Ac tua l pe rforma nc e will
va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for a nd s hould not be us e d in me dic a l life s upport
a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.
5.25M99
1 5
2 .9 ” (7 4 m m ) BLDC Lo w -Vo lt a g e Blo w e r
1 2 /2 4 VDC
Unit of
Part Numbe r
Blowe r Data
Me as ure
Voltage Input
119495
12
119496
24
VDC
Stages
1
1
Pressure, Max. (Sealed Pressure)
in. H2O, Sealed
mBar
3.4
8.4
22
3.4
8.4
22
Flow Rate, Max. (Open Flow)
CFM
L/sec
10.4
10.4
Typical Pe rformance Points
Air Flow
0 CFM
Pre s s ure
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
3.4
3.1
2.9
2.5
1.8
3.4
3.1
2.9
2.5
1.8
4 CFM
8 CFM
12 CFM
16 CFM
Temperature: Working Air: 0o C to 45°C, Ambient Air: 0o C to 45°C, Storage Air: -40o C to 85°C
Dielectric Testing: 200 volts applied for one second between power leads and motor body, one milliamp leakage max.
Speed Control: Speed is controlled by input voltage.
NOTES:
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.
* AMETEK Rotron products are not designed for and should not be used in medical life support applications.
* AMETEK reserves the right to revise its products without notification.
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales.
1 6
2.9BLV99
2 .9 ” (7 4 m m ) BLDC Lo w -Vo lt a g e Blo w e r
1 2 /2 4 VDC
This doc ume nt is for informa tiona l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The
pe rformance data on this page de picts typical pe rformance unde r controlle d laboratory conditions , data is corre cte d to 0.075 lb ./ft3 a ir de ns ity (29.92” Hg @ 70° F.).
Ac tua l pe rforma nc e will va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for us e with vola tile , ha za rdous or
corros ive gas e s . Blowe r hous ings are not s e ale d, s light air/gas le akage will occur. AMETEK Rotron products are not de s igne d for a nd s hould not be us e d in me dic a l
life s upport a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.
1 7
2.9BLV99
3 .0 ” (7 6 m m ) BLDC Lo w -Vo lt a g e Blo w e r
1 2 /2 4 VDC
Unit of
Part Numbe r
Blowe r Data
Me as ure
119349*
119350*
Voltage Input
VDC
12
1
24
1
Stages
Pressure, Max. (Sealed Pressure)
in. H2O, Sealed
mBar
10
10
24.9
18
24.9
18
Flow Rate, Max. (Open Flow)
CFM
L/sec
8.5
8.5
Typical Pe rformance Points
Air Flow
0 CFM
Pre s s ure
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
10
9.1
7.6
5.4
2.4
0
10
9.1
7.6
5.4
2.4
0
4 CFM
8 CFM
12 CFM
16 CFM
18 CFM
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.
Temperature: Working Air: 0o C to 45°C, Ambient Air: 0o C to 45°C, Storage Air: -40o C to 85°C
Dielectric Testing: 200 volts applied for one second between power leads and motor body, one milliamp leakage max.
Speed Control: Speed is controlled by input voltage.
NOTES:
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.
* AMETEK Rotron products are not designed for and should not be used in medical life support applications.
* AMETEK reserves the right to revise its products without notification.
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales.
1 8
3BLV99
3 .0 ” (7 6 m m ) BLDC Lo w -Vo lt a g e Blo w e r
1 2 /2 4 VDC
This doc ume nt is for informa tiona l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The
pe rformance data on this page de picts typical pe rformance unde r controlle d laboratory conditions , data is corre cte d to 0.075 lb ./ft3 a ir de ns ity (29.92” Hg @ 70° F.).
Ac tua l pe rforma nc e will va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for us e with vola tile , ha za rdous or
corros ive gas e s . Blowe r hous ings are not s e ale d, s light air/gas le akage will occur. AMETEK Rotron products are not de s igne d for a nd s hould not be us e d in me dic a l
life s upport a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.
3BLV99
1 9
3 .3 ” (8 4 m m ) BLDC Lo w -Vo lt a g e Blo w e r
1 2 /2 4 VDC
Unit of
Part Numbe r
Blowe r Data
Me as ure
Voltage Input
119497
12
119498
24
VDC
Stages
1
1
Pressure, Max. (Sealed Pressure)
in. H2O, Sealed
mBar
27.3
67.9
7.5
27.3
67.9
7.5
Flow Rate, Max. (Open Flow)
CFM
L/sec
3.5
3.5
Typical Pe rformance Points
Air Flow
0 CFM
Pre s s ure
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
27.0
26.0
20.5
9.0
27.0
26.0
20.5
9.0
2 CFM
4 CFM
6 CFM
8 CFM
0
0
Temperature: Working Air: 0o C to 45°C, Ambient Air: 0o C to 45°C, Storage Air: -40o C to 85°C
Dielectric Testing: 200 volts applied for one second between power leads and motor body, one milliamp leakage max.
Speed Control: Speed is controlled by input voltage.
NOTES:
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.
* AMETEK Rotron products are not designed for and should not be used in medical life support applications.
* AMETEK reserves the right to revise its products without notification.
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales.
2 0
3.3BLV99
3 .3 ” (8 4 m m ) BLDC Lo w -Vo lt a g e Blo w e r
1 2 /2 4 VDC
This doc ume nt is for informa tiona l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The
pe rformance data on this page de picts typical pe rformance unde r controlle d laboratory conditions , data is corre cte d to 0.075 lb ./ft3 a ir de ns ity (29.92” Hg @ 70° F.).
Ac tua l pe rforma nc e will va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for us e with vola tile , ha za rdous or
corros ive gas e s . Blowe r hous ings are not s e ale d, s light air/gas le akage will occur. AMETEK Rotron products are not de s igne d for a nd s hould not be us e d in me dic a l
life s upport a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.
2 1
3.3BLV99
4 .5 ” (1 1 4 m m ) BLDC Lo w -Vo lt a g e Blo w e r
1 2 /2 4 VDC
Unit of
Me as ure
Part Numbe r
Blowe r Data
119494
119395
24
Voltage Input
VDC
12
1
Stages
1
Pressure, Max. (Sealed Pressure)
in. H2O, Sealed
mBar
28.4
70.7
9.1
4.3
28.4
70.7
9.1
Flow Rate, Max. (Open Flow)
CFM
L/sec
4.3
Typical Pe rformance Points
Air Flow
0 CFM
Pre s s ure
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
28.4
26.2
22.4
15.3
5.6
28.4
26.2
22.4
15.3
5.6
2 CFM
4 CFM
6 CFM
8 CFM
10 CFM
0
0
Temperature: Working Air: 0o C to 45°C, Ambient Air: 0o C to 45°C, Storage Air: -40o C to 85°C
Dielectric Testing: 200 volts applied for one second between power leads and motor body, one milliamp leakage max.
Speed Control: Speed is controlled by input voltage.
NOTES:
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.
* AMETEK Rotron products are not designed for and should not be used in medical life support applications.
* AMETEK reserves the right to revise its products without notification.
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales.
2 2
4.5BLV99
4 .5 ” (1 1 4 m m ) BLDC Lo w -Vo lt a g e Blo w e r
1 2 /2 4 VDC
This doc ume nt is for informa tiona l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The
pe rformance data on this page de picts typical pe rformance unde r controlle d laboratory conditions , data is corre cte d to 0.075 lb ./ft3 a ir de ns ity (29.92” Hg @ 70° F.).
Ac tua l pe rforma nc e will va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for us e with vola tile , ha za rdous or
corros ive gas e s . Blowe r hous ings are not s e ale d, s light air/gas le akage will occur. AMETEK Rotron products are not de s igne d for a nd s hould not be us e d in me dic a l
life s upport a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.
2 3
4.5BLV99
5 .0 ” (1 2 7 m m ) BLDC Lo w -Vo lt a g e Blo w e r
1 2 /2 4 VDC
Part Number
Standard Flow
Unit
Measure
High Output
Blower Data
119381 M
119384 M
119385 E
119378 M
119380
119382 E
119383
119375
119379 E
Voltage Input
VDC
12
12
1
24
24
1
24
24
1
Stages
1
12
1
12
1
24
Pressure, Max. (Sealed Pressure)
in. H2O
mBar
12
12
24
30
30
30
30
60
60
Flow Rate, Max. (Open Flow)
Drive Electronics
CFM
34
34
34
34
45
45
L/sec
16
16
16
16
21
21
Internal or External
External
Internal
External
Internal
External
Internal
Typical Performance Points
Pressure
Air Flow
0 CFM
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
12.5
11.7
7.6
12.5
11.7
7.6
12.5
11.7
7.6
12.5
11.7
7.6
24.3
22.0
18.4
10.8
3.5
24.3
22.0
18.4
10.8
3.5
10 CFM
20 CFM
30 CFM
40 CFM
2.3
2.3
2.3
2.3
NOTES:
Temperature: Working Air: 0o C to 45°C, Ambient Air: 0o C to 45°C, Storage Air: -40o C to 85°C
Dielectric Testing: 500 volts AC RMS 60Hz applied for one second between input pins and ground, one milliamps leakage max.
Speed Control: Internal – E (Electrical): Pulse Width Modulated or Analog input voltage (User Supplied), 0 to 5 Volts DC Nominal
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed.
External - These blowers require a 3 phase electronic commutated input to operate. A separate blower controller provides this input and speed
control. AMETEK blower controller part numbers 48069 for 12VDC blowers and 48070 for 24 VDC blowers are design for use with the
above blowers.
2 4
5BLV99
5 .0 ” (1 2 7 m m ) BLDC Lo w -Vo lt a g e Blo w e r
1 2 /2 4 VDC
This doc ume nt is for informa tiona l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The
pe rformance data on this page de picts typical pe rformance unde r controlle d laboratory conditions , data is corre cte d to 0.075 lb ./ft3 a ir de ns ity (29.92” Hg @ 70° F.).
Ac tua l pe rforma nc e will va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for us e with vola tile , ha za rdous or
corros ive gas e s . Blowe r hous ings are not s e ale d, s light air/gas le akage will occur. AMETEK Rotron products are not de s igne d for a nd s hould not be us e d in me dic a l
life s upport a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.
2 5
5BLV99
5 .1 ” (1 3 0 m m ) BLDC Lo w -Vo lt a g e Blo w e r
1 2 /2 4 VDC
Unit of
Me as ure
Part Numbe r
Blowe r Data
119396
119397
24
Voltage Input
VDC
12
1
Stages
1
Pressure, Max. (Sealed Pressure)
in. H2O, Sealed
mBar
25.70
64
25.70
64
Flow Rate, Max. (Open Flow)
CFM
15.30
7.22
15.30
7.22
L/sec
Typical Pe rformance Points
Air Flow
0 CFM
Pre s s ure
25.7
23.8
21.7
19.5
16.5
12.0
7.1
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
25.7
23.8
21.7
19.5
16.5
12.0
7.1
2 CFM
4 CFM
6 CFM
8 CFM
10 CFM
12 CFM
14 CFM
16 CFM
2.2
2.2
0
0
Input voltage: This product requires a 3 phase electronic commutated input to operate. Refer to the controller section of this catalog for proper controller selection.
Input voltages listed in the chart above indicate the controller input voltage requirement.
Temperature: Working Air: 0o C to 45°C, Ambient Air: 0o C to 45°C, Storage Air: -40o C to 85°C
Dielectric Testing: 200 volts applied for one second between power leads and motor body, one milliamp leakage max.
Speed Control: Via 0.5 VDC analog signal or potentiometer setting at controller.
NOTES:
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.
* AMETEK Rotron products are not designed for and should not be used in medical life support applications.
* AMETEK reserves the right to revise its products without notification.
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales.
2 6
5.1BLV99
5 .1 ” (1 3 0 m m ) BLDC Lo w -Vo lt a g e Blo w e r
1 2 /2 4 VDC
This doc ume nt is for informa tiona l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The
pe rformance data on this page de picts typical pe rformance unde r controlle d laboratory conditions , data is corre cte d to 0.075 lb ./ft3 a ir de ns ity (29.92” Hg @ 70° F.).
Ac tua l pe rforma nc e will va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for us e with vola tile , ha za rdous or
corros ive gas e s . Blowe r hous ings are not s e ale d, s light air/gas le akage will occur. AMETEK Rotron products are not de s igne d for a nd s hould not be us e d in me dic a l
life s upport a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.
2 7
5.1BLV99
5 .7 ” (1 4 5 m m ) BLDC Lo w -Vo lt a g e Blo w e r
2 4 VDC
Unit of
Me as ure
Part Numbe rs
Blowe r Data
116521*
24
116522
116450*
24
Voltage Input
VDC
24
Stages
1
2
3
Vacuum, Max. (Sealed Vacuum)
in. H2O
mBar
6
20
24
15
50
60
Pressure, Max. (Sealed Pressure)
Flow Rate, Max. (Open Flow)
Length Dimension “L”
in. H2O, sealed
mBar
8.2
20
22
26
55
64
CFM
39
35
38
L/sec
18
17
18
inches
2.65
67.31
3.66
92.96
4.56
115.82
mm
Typical Pe rformance Points
Air Flow
0 CFM
Pre s s ure
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
8.2
8.0
7.6
7.2
6.3
5.0
3.3
1.7
35.7
18.1
15.5
12.8
10.0
6.3
26.0
23.0
22.0
20.5
17.5
13.0
8.5
5 CFM
10 CFM
15 CFM
20 CFM
25 CFM
30 CFM
35 CFM
4.0
0.10
3.0
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.
Input voltage: This product requires a 3 phase electronic commutated input to operate. Refer to the controller section of this catalog for proper controller selection.
Input voltages listed in the chart above indicate the controller input voltage requirement.
Input current: 6-10 Amps, Current is dependent on blower model.
Temperature: Working Air: 0o C to 45°C, Ambient Air: 0o C to 45°C, Storage Air: -40o C to 85°C
Dielectric Testing: 500 volts AC RMS 60Hz applied for one second between input pins and ground, one milliamp leakage max.
Speed Control: Speed control is achieved at the blower controller. Refer to the controller section (PAGE 45) of this catalog for proper controller operation.
NOTES:
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.
* AMETEK Rotron products are not designed for and should not be used in medical life support applications.
* AMETEK reserves the right to revise its products without notification.
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales.
5.7BLV99
2 8
5 .7 ” (1 4 5 m m ) BLDC Lo w -Vo lt a g e Blo w e r
2 4 VDC
This doc ume nt is for informa tiona l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The
pe rformance data on this page de picts typical pe rformance unde r controlle d laboratory conditions , data is corre cte d to 0.075 lb ./ft3 a ir de ns ity (29.92” Hg @ 70° F.).
Ac tua l pe rforma nc e will va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for us e with vola tile , ha za rdous or
corros ive gas e s . Blowe r hous ings are not s e ale d, s light air/gas le akage will occur. AMETEK Rotron products are not de s igne d for a nd s hould not be us e d in me dic a l
life s upport a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.
5.7BLV99
2 9
5 .7 ” (1 4 5 m m ) BLDC Th ru Flo w Blo w e r
2 5 0 WATT, 1 2 0 VOLT
Part Numbe r
Standard Flow
High Flow
Unit of
Me as ure
Blowe r Data
116626 M
116629 E*
1
116627 M
116630 E*
2
116628 M
116631 E
3
116644 M
116647 E
1
116645 M
116648 E
2
116646 M
116649 E
3
Stages
Vacuum, Max. (Sealed Vacuum)
in. H2O
mBar
in. H2O
mBar
CFM
29
50
70
24
34
45
72
124
174
60
84
112
Pressure, Max. (Sealed Pressure)
Flow Rate, Max. (Open Flow)
Inlet/Outlet Diameter
32
52
75
27
37
50
79
129
186
67
92
124
67
62
46
117
90
80
L/sec
inches
mm
32
29
22
55
42
38
1.25
31.75
0.74
18.80
3.21
81.53
1.25
31.75
1.65
41.91
4.12
104.65
1.25
31.75
2.5
1.75
44.45
0.76
19.30
3.28
83.31
1.75
44.45
1.88
47.75
4.33
109.98
1.75
44.45
1.75
44.45
5.34
135.64
Length (Dimension “I” above)
Length (Dimension “L” above)
inches
mm
63.50
5.02
127.51
inches
mm
Typical Pe rformance Points
Pre s s ure
Air Flow
0 CFM
10 CFM
20 CFM
30 CFM
40 CFM
50 CFM
60 CFM
70 CFM
80 CFM
90 CFM
100 CFM
110 CFM
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
32.0
30.0
28.1
24.3
19.0
12.5
6.0
52.2
44.5
42.3
31.8
21.8
11.7
75.0
27.0
26.1
25.3
23.3
23.0
21.4
18.0
16.7
13.9
10.2
6.1
37.1
34.1
31.7
28.9
25.9
21.4
17.8
12.4
5.7
50.0
46.3
42.0
35.9
28.6
21.9
15.6
7.5
52.2
34.2
21.5
8.0
0
.09
2.6
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.
NOTES:
Nominal input voltage: 120 Volts AC RMS +/- 10%, 60Hz
Input current: 5 amps AC RMS maximum
Temperature: Working Air: 0o C to 50°C, Ambient Air: 0o C to 50°C, Storage Air: -40o C to 85°C
Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max.
Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC
Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection)
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment.
5.7/250TFBHV99
3 0
5 .7 ” (1 4 5 m m ) BLDC Th ru Flo w Blo w e r
2 5 0 WATT, 1 2 0 VOLT
Regulatory Agency Certification: Underwriters Laboratories, Inc. is qualified per UL507 under File E-94403. Canadian Standards Association is qualified per
C22.2#113 under File LR 43448.
Miscellaneous: Intake & exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil, or foreign particles.
Amp housing #350809-1 (to be supplied by customer), mates with post header assembly.
This doc ume nt is for informa tiona l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The
pe rformance data on this page de picts typical pe rformance unde r controlle d laboratory conditions , data is corre cte d to 0.075 lb ./ft3 a ir de ns ity (29.92” Hg @ 70° F.).
Ac tua l pe rforma nc e will va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for us e with vola tile , ha za rdous or
corros ive gas e s . Blowe r hous ings are not s e ale d, s light air/gas le akage will occur. AMETEK Rotron products are not de s igne d for a nd s hould not be us e d in me dic a l
life s upport a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.
5.7/250TFBHV99
3 1
5 .7 ” (1 4 5 m m ) BLDC Byp a s s Blo w e r
2 5 0 WATT, 1 2 0 VOLT
Part Numbe r
Standard Flow
High Flow
116636 M*
Unit of
Me as ure
Blowe r Data
116634 M*
116633 M
116632 M*
116637 M*
116635 M
116640 E*
1
116639 E
2
116638 E*
3
116643 E*
1
116642 E*
2
116641 E
3
Stages
Vacuum, Max. (Sealed Vacuum)
in. H2O
mBar
in. H2O
mBar
CFM
29
48
65
26
57.5
143
42
72
119
161
64
104
Pressure, Max. (Sealed Pressure)
Flow Rate, Max. (Open Flow)
Inlet/Outlet Diameter
32
56
76
27
68.0
169
46
79
139
188
67
114
68
63
49
115
110
80
L/sec
inches
mm
32
30
23
54
52
38
1.25
31.75
0.33
8.38
5.08
129.03
1.25
31.75
1.25
31.75
6.35
161.29
1.25
31.75
2.14
54.36
6.89
175.01
1.75
44.45
0.47
11.94
5.22
132.59
1.75
44.45
1.53
38.86
6.27
159.26
1.75
44.45
2.53
64.26
7.28
184.91
Length (Dimension “I” above)
Length (Dimension “L” above)
inches
mm
inches
mm
Typical Pe rformance Points
Pre s s ure
Air Flow
0 CFM
10 CFM
20 CFM
30 CFM
40 CFM
50 CFM
60 CFM
70 CFM
80 CFM
90 CFM
100 CFM
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
31.8
28.7
27.7
24.7
20.1
14.5
7.3
56.1
48.0
44.3
38.1
28.9
18.2
4.2
76.2
27.1
25.0
24.4
22.9
21.2
19.1
17.2
15.0
12.2
8.0
48.1
44.0
41.6
37.9
32.2
25.8
20.5
15.8
7.1
46.0
42.8
39.2
34.9
30.0
24.3
16.2
9.8
60.3
44.1
28.9
16.1
5.5
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.
NOTES:
Nominal input voltage: 120 Volts AC RMS +/- 10%, 60Hz
Input current: 5 amps AC RMS maximum
Temperature: Working Air: 0o C to 50°C, Ambient Air: 0o C to 50°C, Storage Air: -40o C to 85°C
Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max.
Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC
Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection)
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment.
3 2
5.7/250BHV99
5 .7 ” (1 4 5 m m ) BLDC Byp a s s Blo w e r
2 5 0 WATT, 1 2 0 VOLT
Regulatory Agency Certification: Underwriters Laboratories, Inc. is qualified per UL507 under File E-94403; Canadian Standards Association is qualified per
C22.2#113 under File LR 43448.
Miscellaneous: Intake & exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust are free of grease, oil, or foreign particles. Amp
housing #640250-6 (to be supplied by customer), mates with post header assembly.
This doc ume nt is for informa tiona l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The
pe rformance data on this page de picts typical pe rformance unde r controlle d laboratory conditions , data is corre cte d to 0.075 lb ./ft3 a ir de ns ity (29.92” Hg @ 70° F.).
Ac tua l pe rforma nc e will va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for us e with vola tile , ha za rdous or
corros ive gas e s . Blowe r hous ings are not s e ale d, s light air/gas le akage will occur. AMETEK Rotron products are not de s igne d for a nd s hould not be us e d in me dic a l
life s upport a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.
3 3
5.7/250BHV99
5 .7 ” (1 4 5 m m ) BLDC Th ru Flo w Blo w e r
4 0 0 WATT, 2 4 0 VOLT
Part Numbe r
Standard Flow
Unit of
Me as ure
Blowe r Data
117629 E*
1
117630 E*
2
Stages
Vacuum, Max. (Sealed Vacuum)
in. H2O
mBar
in. H2O
mBar
CFM
28
47
69
117
Pressure, Max. (Sealed Pressure)
Flow Rate, Max. (Open Flow)
Length (Dimension “I” above)
Length (Dimension “L” above)
31
50
77
124
67
65
L/sec
inches
mm
32
31
.69
1.60
40.64
4.12
104.65
17.53
3.21
81.53
inches
mm
Typical Pe rformance Points
Pre s s ure
Air Flow
0 CFM
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
31.1
26.8
23.8
20.5
15.8
10.0
4.4
50.5
45.4
40.9
33.7
25.3
16.0
6.46
10 CFM
20 CFM
30 CFM
40 CFM
50 CFM
60 CFM
70 CFM
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.
NOTES:
Nominal input voltage: 240 Volts AC RMS +/- 10%, 60Hz
Input current: 5 amps AC RMS maximum
Temperature: Working Air: 0o C to 50°C, Ambient Air: 0o C to 50°C, Storage Air: -40o C to 85°C
Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max.
Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC
Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection)
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment.
3 4
5.7/400TFBHV99
5 .7 ” (1 4 5 m m ) BLDC Th ru Flo w Blo w e r
4 0 0 WATT, 2 4 0 VOLT
Regulatory Agency Certification: Underwriters Laboratories, Inc. is qualified per UL507 under File E-94403; Canadian Standards Association is qualified per
C22.2#113 under File LR 43448.
Miscellaneous: Intake & exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust are free of grease, oil, or foreign particles. Amp
housing #350809-1 (to be supplied by customer), mates with post header assembly.
This doc ume nt is for informa tiona l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The
pe rformance data on this page de picts typical pe rformance unde r controlle d laboratory conditions , data is corre cte d to 0.075 lb ./ft3 a ir de ns ity (29.92” Hg @ 70° F.).
Ac tua l pe rforma nc e will va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for us e with vola tile , ha za rdous or
corros ive gas e s . Blowe r hous ings are not s e ale d, s light air/gas le akage will occur. AMETEK Rotron products are not de s igne d for a nd s hould not be us e d in me dic a l
life s upport a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.
5.7/400TFBHV99
3 5
5 .7 ” (1 4 5 m m ) BLDC Byp a s s Blo w e r
4 0 0 WATT, 2 4 0 VOLT
Part Numbe r
Standard Flow
High Flow
Unit of
Me as ure
Blowe r Data
117634 M*
117640 E*
1
117633 M
117639 E
2
117632 M*
117638 E*
3
117637 M*
117643 E*
1
117636 M*
117642 E*
2
117635 M*
117641 E*
3
Stages
Vacuum, Max. (Sealed Vacuum)
in. H2O
mBar
n. H2O
mBar
CFM
28
45
60
23
39
53
69
112
149
57
97
131
Pressure, Max. (Sealed Pressure)
Flow Rate, Max. (Open Flow)
Inlet/Outlet Diameter
30
51
70
25
45
61
74
126
174
62
112
151
69
62
58
114
97
86
L/sec
inches
mm
33
29
27
54
46
41
1.25
31.75
2.53
64.26
5.08
129.03
1.25
31.75
1.25
31.75
5.99
152.15
1.25
31.75
2.14
54.36
6.89
175.01
1.75
44.45
.47
1.75
44.45
1.53
38.86
6.27
159.26
1.75
44.45
2.53
64.26
7.28
184.91
Length (Dimension “I” above)
Length (Dimension “L” above)
inches
mm
11.94
5.22
132.59
inches
mm
Typical Pe rformance Points
Pre s s ure
Air Flow
0 CFM
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
30.3
27.9
26.2
23.6
19.0
13.3
7.0
51.0
44.2
41.8
35.9
27.8
16.6
3.7
69.9
24.8
23.6
22.6
21.5
19.5
17.9
16.1
13.8
12.0
8.7
44.6
41.0
39.8
35.8
32.0
28.0
23.9
17.9
12.1
0
61.5
55.8
51.5
46.0
40.1
34.2
28.2
19.6
8.1
10 CFM
20 CFM
30 CFM
40 CFM
50 CFM
60 CFM
70 CFM
80 CFM
90 CFM
100 CFM
110 CFM
59.9
52.8
44.1
32.1
18.1
3.7
6.7
0
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.
NOTES:
Nominal input voltage: 240 Volts AC RMS +/- 10%, 50/60Hz
Input current: 5 amps AC RMS maximum
Temperature: Working Air: 0o C to 50°C, Ambient Air: 0o C to 50°C, Storage Air: -40o C to 85°C
Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max.
Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC
Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection)
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment.
5.7/400BHV99
3 6
5 .7 ” (1 4 5 m m ) BLDC Byp a s s Blo w e r
4 0 0 WATT, 2 4 0 VOLT
Regulatory Agency Certification: T.U.V. Rheinland Bauart Certification* is qualified per EN60950 under License No. R0097184.
Underwriters Laboratories, Inc. Qualified per UL507 under File E-94403. Canadian Standards Association Qualified per C22.2#113 under File LR 43448.
Miscellaneous: Intake & exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust are free of grease, oil, or foreign particles. Amp
housing #1-480763-0 (to be supplied by customer), mates with post header assembly.
*IEC 801 testing has been completed, and specific data can be provided upon request.
This doc ume nt is for informa tiona l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The
pe rformance data on this page de picts typical pe rformance unde r controlle d laboratory conditions , data is corre cte d to 0.075 lb ./ft3 a ir de ns ity (29.92” Hg @ 70° F.).
Ac tua l pe rforma nc e will va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for us e with vola tile , ha za rdous or
corros ive gas e s . Blowe r hous ings are not s e ale d, s light air/gas le akage will occur. AMETEK Rotron products are not de s igne d for a nd s hould not be us e d in me dic a l
life s upport a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.
5.7/400BHV99
3 7
5 .7 ” (1 4 5 m m ) BLDC Byp a s s Blo w e r
8 0 0 WATT, 1 2 0 VOLT
Part Numbe r
High Flow
Standard Flow
Ultra Flow
Unit of
Me as ure
Blowe r Data
117418 M*
119102 M*
119104 M*
117417 E*
3
119101 E*
1
119103 E*
2
119105 E*
Stages
1
26
Vacuum, Max. (Sealed Vacuum)
in. H2O
mBar
in. H2O
mBar
CFM
106
41
71
263
102
176
64
Pressure, Max. (Sealed Pressure)
Flow Rate, Max. (Open Flow)
Inlet/Outlet Diameter
115
44
76
29
285
109
188
72
67
161
119
242
L/sec
inches
mm
32
76
56
114
1.25
31.75
2.12
53.85
6.87
174.50
1.75
44.45
.47
1.75
44.45
1.53
38.86
6.35
161.29
2.75/2.50
69.85/63.50
.71
Length (Dimension “I” above)
Length (Dimension “L” above)
inches
mm
11.94
5.30
134.62
18.03
5.46
inches
mm
138.68
Typical Pe rformance Points
Pre s s ure
Air Flow
0 CFM
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
115.8
44.1
41.8
39.2
34.1
29.0
23.3
14.4
7.0
76.2
68.4
57.2
43.5
33.2
19.8
0
29.3
27.5
26.1
23.5
21.6
17.6
15.8
14.1
11.2
8.2
20 CFM
40 CFM
60 CFM
80 CFM
100 CFM
120 CFM
140 CFM
160 CFM
180 CFM
200 CFM
220 CFM
240 CFM
86.6
54.9
18.3
0
5.5
2.8
1.2
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.
NOTES:
Nominal input voltage: 120 Volts AC RMS +/- 10%, 60Hz
Input current: 10 amps AC RMS maximum
Temperature: Working Air: 0o C to 50°C, Ambient Air: 0o C to 50°C, Storage Air: -40o C to 85°C
Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max.
Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC
Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection)
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment.
3 8
5.7/800BHV99
5 .7 ” (1 4 5 m m ) BLDC Byp a s s Blo w e r
8 0 0 WATT, 1 2 0 VOLT
Regulatory Agency Certification: T.U.V. Rheinland Bauart Certification* is qualified per EN60950 under Licence No. R9571008; Underwriters Laboratories, Inc. is
qualified per UL507 under File E-94403; Canadian Standards Association is qualified per C22.2#113 under File LR 43448.
Miscellaneous: Intake & exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil, or foreign particles.
Amp housing #350810-1(to be supplied by customer), mates with post header assembly.
This doc ume nt is for informa tiona l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The
pe rformance data on this page de picts typical pe rformance unde r controlle d laboratory conditions , data is corre cte d to 0.075 lb ./ft3 a ir de ns ity (29.92” Hg @ 70° F.).
Ac tua l pe rforma nc e will va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for us e with vola tile , ha za rdous or
corros ive gas e s . Blowe r hous ings are not s e ale d, s light air/gas le akage will occur. AMETEK Rotron products are not de s igne d for a nd s hould not be us e d in me dic a l
life s upport a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.
3 9
5.7/800BHV99
5 .7 ” (1 4 5 m m ) DC Byp a s s Blo w e r
1 2 0 0 WATT, 2 4 0 VOLT
Part Numbe r
High Flow
Standard Flow
Ultra Flow
Unit of
Me as ure
Blowe r Data
117416 M*
119152 M*
119154 M*
117415 E*
3
119151 E*
1
119153 E*
2
119155 E*
Stages
1
33
Vacuum, Max. (Sealed Vacuum)
in. H2O
mBar
135
50
91
335
124
226
82
Pressure, Max. (Sealed Pressure)
Flow Rate, Max. (Open Flow)
Inlet/Outlet Diameter
in. H O
144
54
97
39
2
mBar
CFM
L/sec
inches
mm
357
134
241
97
82
190
156
307
39
90
74
145
1.25
31.75
2.12
53.85
6.87
174.50
1.75
44.45
.47
1.75
44.45
1.53
38.86
6.35
161.29
2.75/2.50
69.85/63.50
.70
Length (Dimension “I” above)
Length (Dimension “L” above)
inches
mm
11.94
5.11
128.77
17.78
5.47
inches
mm
138.94
Typical Pe rformance Points
Pre s s ure
Air Flow
0 CFM
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
in. H2O
144.3
54.0
53.9
51.1
47.0
43.2
37.0
29.4
22.3
14.2
97.0
92.5
85.8
75.9
62.3
40.5
32.1
15.0
39.2
38.0
37.5
35.3
33.5
31.4
28.0
25.4
21.5
18.5
16.1
13.1
10.0
7.4
20 CFM
129.1
102.9
60.8
40 CFM
60 CFM
80 CFM
10.8
100 CFM
120 CFM
140 CFM
160 CFM
180 CFM
200 CFM
220 CFM
240 CFM
260 CFM
280 CFM
300 CFM
4.3
1.0
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.
NOTES:
Nominal input voltage: 240 Volts AC RMS +/- 10%, 50/60Hz
Input current: 5 amps AC RMS maximum
Temperature: Working Air: 0o C to 50°C, Ambient Air: 0o C to 50°C, Storage Air: -40o C to 85°C
Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max.
4 0
5.7/1200BHV99
5 .7 ” (1 4 5 m m ) DC Byp a s s Blo w e r
1 2 0 0 WATT, 2 4 0 VOLT
NOTES (continue d):
Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC
Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection)
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment.
Regulatory Agency Certification: T.U.V. Rheinland Bauart Certification* is qualified per EN60950 under License No. 9571008; Underwriters Laboratories, Inc. is
qualified per UL507 under File E 94403; Canadian Standards Association is qualified per C22.2#113 under File LR 43448.
Miscellaneous: Intake & exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil, or foreign particles.
Amp housing #350809-1 (to be supplied by customer), mates with post header assembly.
*IEC 801 testing has been completed, and specific data can be provided upon request.
This doc ume nt is for informa tiona l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The
pe rformance data on this page de picts typical pe rformance unde r controlle d laboratory conditions , data is corre cte d to 0.075 lb ./ft3 a ir de ns ity (29.92” Hg @ 70° F.).
Ac tua l pe rforma nc e will va ry de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for us e with vola tile , ha za rdous or
corros ive gas e s . Blowe r hous ings are not s e ale d, s light air/gas le akage will occur. AMETEK Rotron products are not de s igne d for a nd s hould not be us e d in me dic a l
life s upport a pplic a tions . AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.
5.7/1200BHV99
4 1
5 Am p BLDC Blo w e r Co n t ro lle r
Blowe r Contolle rs
48132
Controlle r Data
Max Continuous Current
Input Voltage Range
Controller PWM Frequency
Analog Speed Input
Electrical Hall Spacing
Waveform
5 A
11-52 VDC
25 kHz
0-5 VDC
600 or 1200
8-Step Trapezoidal
Yes
Current Limit Protection
Rotation
CW / CCW
NOTES:
Temperature: Operating: 0o C to 50°C, Storage Air: -40o C to 85°C
Speed Control: Electrical speed control is achieved by applying a 0 to 5 VDC signal on J1 Pin 3 with respect to J1 Pin 2. Mechanical speed control is achieved by
adjusting the potentiometer when J6 is in position 1 to 2.
Current Control: Trip point is at 5 Amp maximum.
J1-1 Vin
J4-1 Motor Phase A
J4-2 Motor Phase C
J4-3 Hall - (Gnd)
J4-4 Hall 1
J1-2 Vin Return (Gnd)
J1-3 Analog Speed In
J4-5 Hall 2
J4-6 Hall 3
J4-7 Hall + (+12V)
J4-8 Motor Phase B
Caution should be taken. Misplacement of jumper setting will destroy the control.
Jumper Settings:
J6 Set to position 1-2 for internal speed adjust.
Set to position 2-3 for analog speed input voltage.
J3 Disable or enable to determine forward/reverse rotation.
J2 Disable for 60° electrical spacing.
Enable for 120° electrical spacing.
J5 Set position 1-2 for 16-52 VDC
Set position 2-3 for 11-16 VDC
This doc ume nt is for informa tiona l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The
pe rforma nc e da ta on this pa ge de pic ts typic a l pe rforma nc e unde r c ontrolle d la bora tory c onditions us ing c ons ta nt DC volta ge s . Actual pe rformance will vary
de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for a nd s hould not be us e d in me dic a l life s upport a pplic a tions .
AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.
4 2
5BC99
1 0 Am p BLDC Blo w e r Co n t ro lle r
Blowe r Contolle rs
48133
Controlle r Data
Max Continuous Current
Input Voltage Range
Controller PWM Frequency
Analog Speed Input
Electrical Hall Spacing
Waveform
10 A
11-52 VDC
25 kHz
0-5 VDC
600 or 1200
8-Step Trapezoidal
Yes
Current Limit Protection
Rotation
CW / CCW
NOTES:
Temperature: Operating: 0o C to 50°C, Storage Air: -40o C to 85°C
Speed Control: Electrical speed control is achieved by applying a 0 to 5 VDC signal on J1 Pin 3 with respect to J1 Pin 2. Mechanical speed control is achieved by
adjusting the potentiometer when J6 is in position 1to 2.
Current Control: Trip point is at 10 Amp maximum.
J1-1 Vin
J4-1 Phase C
J4-2 Phase B
J4-3 Phase A
J4-4 Hall - (Gnd)
J4-5 Hall + (+12V)
J4-6 Hall 1
J1-2 Gnd
J1-3 Analog Speed In
J4-7 Hall 2
J4-8 Hall 3
Caution should be taken. Misplacement of jumper setting will destroy the control.
Jumper Settings:
J6 Set to position 1-2 for internal speed adjust.
Set to position 2-3 for analog speed input voltage.
J3 Disable or enable to determine forward/reverse rotation.
J2 Disable for 60° electrical spacing.
Enable for 120° electrical spacing.
J5 Set position 1-2 for 16-52 VDC
Set position 2-3 for 11-16 VDC
This doc ume nt is for informa tiona l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The
pe rforma nc e da ta on this pa ge de pic ts typic a l pe rforma nc e unde r c ontrolle d la bora tory c onditions us ing c ons ta nt DC volta ge s . Actual pe rformance will vary
de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for a nd s hould not be us e d in me dic a l life s upport a pplic a tions .
AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.
4 3
5BC99
2 0 Am p BLDC Mo t o r Co n t ro lle r
Motor Contolle r
48134
Controlle r Data
Max Continuous Current
Input Voltage Range
Controller PWM Frequency
Analog Speed Input
Electrical Hall Spacing
Waveform
20 A
11-52 VDC
25 kHz
0-5 VDC
600 or 1200
8-Step Trapezoidal
Yes
Current Limit Protection
Rotation
CW / CCW
NOTES:
Temperature: Operating: 0o C to 50°C, Storage Air: -40o C to 85°C
Speed Control: Electrical speed control is achieved by applying a 0 to 5 VDC signal on J4 Pin 12 with respect to J4 Pin 7. Mechanical speed control is achieved by
adjusting the potentiometer when J6 is in position 1 to 2.
Current Control: Trip point is at 20 Amp maximum.
J4-6 Brake
J4-5 Hall +
J4-4 Hall 3
J4-3 Hall 2
J4-2 Hall 1
J4-1 Gnd
J4-12 Analog/In
J4-11 Freq. Out
J4-10 For./Rev.
J4-9 Output Enable
J4-8 Vref
J1-1 Vin
J1-2 Phase A
J1-3 Phase B
J1-4 Phase C
J1-5 Ground
J4-7 Ground
Caution should be taken. Misplacement of jumper setting will destroy the control.
Jumper Settings:
J5 Set to position 1-2 for 16-52 VDC operation.
Set to position 2-3 for 11-16 VDC operation.
J6 Set to position 1-2 for internal speed adjust.
Set to position 2-3 for analog speed input voltage.
J3 Disable or enable to determine forward/reverse rotation.
J2 Disable for 60° electrical spacing.
Enable for 120° electrical spacing.
This doc ume nt is for informa tiona l purpos e s only a nd s hould not be c ons ide re d a s a binding de s c ription of the produc ts or the ir pe rforma nc e in a ll a pplic a tions . The
pe rforma nc e da ta on this pa ge de pic ts typic a l pe rforma nc e unde r c ontrolle d la bora tory c onditions us ing c ons ta nt DC volta ge s . Actual pe rformance will vary
de pe nding on the ope ra ting e nvironme nt a nd a pplic a tion. AMETEK Rotron produc ts a re not de s igne d for a nd s hould not be us e d in me dic a l life s upport a pplic a tions .
AMETEK re s e rve s the right to re vis e its produc ts without notific a tion.
20MC99
4 4
BLDC Mo t o r/Blo w e r Co n t ro lle r Nu m b e rs
Motor/Blowe r
Part
Controlle r
Part
Numbe rs
48134
48134
48134
48134
48134
48134
48134
48134
48134
48134
48134
48134
48134
48134
48134
48134
48134
48134
48134
48134
48133
48133
48133
N/A
Mating Cable
From Controlle r
to Blowe r/Motor
N/A
Ca ble
mm
inc he s
In p u t
Powe r Cable
N/A
Num be rs
119272
119275
119000
119001
119002
119003
119004
119005
119006
119007
119008
119050
119051
119052
119053
119054
119055
119056
119057
119058
119375
119380
119383
119381
119382
119384
119385
119378
119379
119396
119397
116521
116522
116450
117007**
117011**
119319**
119317**
39831
39817
457.2±12.7
457.2 ±12.7
609.6±12.7
304.8±12.7
152.4±12.7
304.8±3.0
457.2±3.0
609.6±3.0
145.0±3.0
292.1±3.0
241.3±3.0
304.8±12.7
457.2±12.7
609.6±12.7
368.3±12.7
304.8±12.7
457.2±12.7
609.6±12.7
18.00±.50
18.00±.50
24.00±.50
12.00+.50
6.00±.50
N/A
N/A
39817-1
39817-2
39851
39831 or 39817*
39831 or 39817*
39831 or 39817*
39831 or 39817*
39831 or 39817*
39831 or 39817*
39831 or 39817*
39831 or 39817*
39831 or 39817*
39831 or 39817*
39831 or 39817*
39831 or 39817*
39831 or 39817*
39831 or 39817*
39831 or 39817*
39831 or 39817*
39831 or 39817*
39831 or 39817*
39851
N/A
N/A
N/A
39851-1
39851-2
39851-3
39685
12.00±.12
18.00±.12
24.00±.12
5.71±.12
N/A
N/A
N/A
N/A
39685-1
39685-2
39685-3
39685-4
39685-5
39773
11.50±.12
9.50±.12
N/A
N/A
12.00±.50
18.00±.50
24.00±.50
14.50±.50
12.00±.50
18.00±.50
24.00±.50
N/A
N/A
N/A
N/A
39773-1
39773-2
39773-3
N/A
N/A
N/A
N/A
N/A
39773
39773
39773
39773
39773
39773
39773
39773
39773
N/A
39851
39851
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
48134
48134
48133
48133
48133
48132
48132
48132
48132
N/A
N/A
N/A
N/A
39773
39773
39773
39773
39773
39773
39773
N/A
N/A
39685
39685
39685
39685
*
Cable 39831 transfers hall signals from the motor to the controller. Cable 39817 does the same, but also provides cabling for analog input, tach output,
braking, forward/reverse, enable/disable, and voltage reference of a nominal 6.25 VDC at a maximum of 10 mAmp.
** Earlier versions of the 5.0" Minijammer blower.
MBCP99
4 5
PLEASE COMPLETE THIS FORM AND FAX IT TO (330) 678-8227,
ATTENTION: ROTRON MARKETING DEPARTMENT
DATE
COMPANY
ADDRESS
CITY
STATE
FAX
ZIP
NAME
TITLE
DEPT.
TELEPHONE
Complete applicable side for additional information.
Blo w e r S izin g
Mo t o r S izin g
Purpose of product which motor is to
be incorporated in
Purpose of product which blower is to
be incorporated in
Describe general operation
Describe general operation
Estimated annual requirements
Estimated annual requirements
Power Supply
VDC
Other
RPM
Power Supply
VDC
VAC
CFM
In. H2O
Speed Requirements
To
Air Flow Requirements
Pressure Requirements
To
To
Maximum Continuous Performace Requirement
Speed
Torque
Power
RPM
Oz. In.
HP
Standard Operating Point:
Pressure or Vacuum
In. H2O, Flow
CFM
Surrounding Temperature:
Dimension, Max.:
Diameter
o
o
Min.
F
Max.
F
Inches,
Length
Max.
Inches
Humidity
Surrounding Temperature:
Agency Requirements:
ISO9001 UL
o
o
Min.
F
F
TUV
CSA
Other
Humidity
Expected Life Hours
Expected Life Hours
Production Delivery Date
Expected Price Range
Production Delivery Date
Expected Price Range
If Replacement
If Replacement
Current Manufacturer
Current Manufacturer
Model
Model
4 6
Throughout our catalog, you will find terminology
used for air moving selection and product sizing.
Below are a few of the key terms:
Flow
Specific Gravity
• Volume Rate/Time
• AMETEK charts are in SCFM, m3/min, or L/S
• SCFM = Standard Cubic Feet Per Minute
(American)
• Density Ratio Relative to Air
• Standard Air SG = 1.0
• Methane SG = 0.55
• Air density = 0.075 lb/cubic foot
• M3/min = Cubic Meters Per Minute (Metric)
• L/sec = Liters Per Second (Metric)
• 1 m3/min = 35.3 SCFM
Velocity
• Distance/Time or Flow/Area
• FPM = Feet Per Minute (American)
• M/min = Meters Per Minute (Metric)
• 1 L/sec = 2.119 SCFM
• See Standard Engineering Conversions for
other flows on pg. 44
• See Standard Engineering Conversion Chart
for other velocities on pg. 44
Pressure Drop/Back Pressure/Impedance
Pressure
• Force/Area
• Friction causes air to slow down and lost
energy is measured in pressure drop terms
• Typical pressure drop areas include piping,
elbows, accessories and system
• AMETEK charts are in In. H2O (IWG), PSIG,
MM of Water, IHG, or mbar
• IWG = Inches of Water Gauge (American)
• PSIG = Pounds Per Square Inch Gauge
(American)
• Each fixed system has a fixed system
impedance caused by a single or multiple
pressure drop points
• mm of Water = Millimeter of Water Gauge
(Metric)
• Changing the system impedance will cause
the blower’s work point to change
• IHG = Inches of Mercury Gauge (American)
• mbar = Millibar Gauge (Metric)
• PSIA = Pounds Per Square Inch Absolute
(American)
• 27.7 IWG = 1 PSIG
• 703.58 MM of Water = 1 PSIG
• 2.036 IHG = 1 PSIG
• 0.069 Bars = 69 mbar = 1 PSIG
• Standard Atmosphere = 0 PSIG = 14.7 PSIA
• See Basic Fan Laws Chart for correcting
pressure due to speed or density changes
Density
• Weight/Volume
• Standard Air = 0.075 lb/cubic foot
4 7
AE99
Standard Engineering Conversions
MULTIPLY
BY
76.0
29.92
406.8348
10,333
1.013 x 105
14.70
TO OBTAIN
MULTIPLY
Kgs ./Cubic Meter
Kilometers
Kilowa tts
Kilowa tts
Kilowa tts
BY
0.06243
3281
56.92
737.6
1.341
14.34
3415
TO OBTAIN
Pounds /Cubic Foot
Feet
Britis h Thermal Units /Min.
Foot-Pounds /Sec.
Hors e p owe r
Kg.-Calories /Min.
Britis h Thermal Units
Atmos pheres
Atmos pheres
Atmos pheres
Atmos pheres
Atmos pheres
Atmos pheres
Atmos pheres
Cms . of Mercury
Inches of Mercury
Inches of Water
Kgs ./Sq. Meter
Pascals
Pounds/Sq. Inch
Torrs
Kilowa tts
Kilowa tt-Hours
760
Bars
Bars
Bars
Bars
0.9869
1. x 105
1.020 x 104
14.50
0.2520
777.5
1054
107.5
2.928 x 10–4
Atmos pheres
Liters
Liters
Liters
Liters
Liters/Minute
Log 10
Log N or Ln N
103
61.02
10–3
.2642
.0353
2.303
0.4343
Cubic Centimeters
Cubic Inches
Cubic Meters
Gallons
Cubic Feet/Minute
LogEN or Ln N
Log 10N
Dynes /Sq. Cm.
Kgs ./Square Meter
Pounds/Sq. Inch
Kilogra m-Ca lorie s
Foot-P ound s
J oules
Kilogram-Meters
Kilowa tt-Hours
Britis h Thermal Units
Britis h Thermal Units
Britis h Thermal Units
Britis h Thermal Units
Britis h Thermal Units
N
Me te rs
Me te rs
Me te rs
Me te rs
Me te rs
Miles
Miles
Miles
100
Ce ntime te rs
Feet
Inches
Kilometers
Millime te rs
Feet
Kilometers
Yards
Inches of Water
Inches of Mercury
Kgs ./Square Cm.
Pounds/Square Inch
3.2808
39.37
10–3
103
5280
1.6093
1760
.4019
0.0394
1.3595–3
0.01934
Centimeters of Mercury
Centimeters of Mercury
Centimeters of Mercury
Centimeters of Mercury
Centimeters /Second
Centimeters /Second
Cubic Centimeters
Cubic Centimeters
Cubic Centimeters
Cubic Centimeters
Cubic Feet
0.01316
0.0372
136.0
0.1934
1.969
Atmos pheres
Inches of Water
Kgs ./Square Meter
Pounds/Sq. Inch
Feet/Minute
Meters /Minute
Cubic Feet
Cubic Inches
Cubic Meters
Liters
Cubic Cms .
Cubic Inches
Cubic Meters
Cubic Yards
0.6
3.531 x 10–5
6.102 x 10–2
10-6
Millibars
Mms . of Mercury
Mms . of Mercury
Mms . of Mercury
10-3
2.832 x 104
1728
0.02832
0.03704
28.32
Newton Meters
.7376
Pound-Force-Foot
Cubic Feet
Cubic Feet
Cubic Feet
Cubic Feet
Ounce - Force - Inch
Ounce - Force - Inch
Ounce - Force - Inch
0.706
7.06 x 10–3
5.21 x 10–3
Newton - Centimeter
Newton - Meter
Pound - Force - Foot
Liters
Pascals
Pints (Liq.)
Pints (U.S. liquid)
Pints (U.S. liquid)
Pounds
Pounds
Pounds
Pounds of Carbon to CO2
Pounds of Water
Pounds of Water
Pounds of Water
.004
Inches of Water
Cubic Inches
Cubic Centimeters
Ounces (U.S. fluid)
Dynes
Cubic Feet/Minute
Cubic Feet/Minute
Cubic Feet/Minute
Cubic Feet/Minute
Cubic Feet/Minute
Cubic Feet/Minute
Cubic Inches
Cubic Inches
Cubic Inches
Cubic Meters
Cubic Meters
472.0
Cubic Cms ./Sec.
Cubic Meters /Hour
Cubic Meters/Minute
Liters/Minute
Liters /Second
Lbs . of Water/Min.
Cubic Centimeters
Cubic Feet
Cubic Meters
Cubic Centimeters
Cubic Feet
Cubic Inches
Cubic Feet/Minute
Cubic Feet/Minute
28.87
473,179
16
444,823
453.6
16
14,544
27.68
0.1198
1.6992
.02832
28.32
0.4720
62.4
Grams
Ounces
16.39
5.787 x 10–4
1.639 x 10–5
105
Britis h Thermal Units (mean)
Cubic Inches
Gallons
35.31
61,023
.5885
Evaporated at 212O
Pounds /Cubic Foot
Pounds /Cubic Foot
Pounds-Force-Foot
Pounds/Square Inch
Pounds/Square Inch
Pounds/Square Inch
Pounds/Square Inch
Pounds/Square Inch
Pounds/Square Inch
F
970.3
16.02
4.882
1.3558
0.06804
27.7
2.036
703.1
6.895 x 103
51.715
1.973 x 105
1.076 x 10–3
0.1550
Britis h Thermal Units
Kgs ./Cubic Meter
Kgs ./Square Meter
Newton Meters
Atmos pheres
Inches of Water
Cubic Meters
Cubic Meters/Hour
Cubic Meters/Minute
35.3107
Feet
Feet
Feet
Feet
30.48
12
0.3048
1/3
Ce ntime te rs
Inches
Me te rs
Inches of Mercury
Kgs ./Square Meter
Pascals
Yards
Feet of Air
(1 atmos phere 60O F)
5.30 x 10–4
Pounds/Square Inch
Millimeters of Mercury at 0O
C
Gallons
Grams /Cu. Cm.
3.785
62.43
Liters
Pounds /Cubic Foot
Square Centimeters
Square Centimeters
Square Centimeters
Square Feet
Square Feet
Square Inches
Square Inches
Square Inches
Square Inches
Circular Mils
Square Feet
Hors e p owe r
Hors e p owe r
Hors e p owe r
Hors e p owe r
42.44
33,000
10.70
745.7
2547
Britis h Thermal Units /Min.
Foot-Pounds /Min.
Kg. Calories /Min.
Watts
Square Inches
Square Centimeters
Square Meters
Circular Mils
Square Centimeters
Square Feet
929.0
0.09290
1.273 x 106
6.452
6.944 x 10–3
106
Hors epower-Hours
Britis h Thermal Units
Inches
Inches
2.540
103
Ce ntime te rs
Mils
Square Mils
Inches of Mercury
Inches of Mercury
Inches of Mercury
Inches of Mercury
Inches of Mercury
Inches of Water
Inches of Water
Inches of Water
Inches of Water
Inches of Water
Inches of Water
Inches of Water
0.03342
13.60
345.3
Atmos pheres
Inches of Water
Kgs ./Square Meter
Mms . of Mercury
Pounds/Square In.
Atmos pheres
Inches of Mercury
Kgs ./Square Meter
Millibars
Square Inches
645.2
Square Millimeters
Square Feet
Square Yards
Square Feet
Square Kilometers
Square Kilometers
Square Meters
Square Meters
Temp. (OC) +273
Temp. (OC) +17.8
Temp. (OF) +460
Temp. (OF) -32
10.76 x 106
1.196 x 106
10.764
25.40
0.4912
0.002458
0.07355
25.40
2.4884
248.8
1.196
Square Yards
1
1.8
1
Abs . Temp. (OC)
Temp. (OF)
Abs . Temp. (OF)
Temp. (OC)
5/9
Pascals
Pounds /Square Ft.
Pounds/Square In.
Watts
Watts
Watts
Watts
Watts
Wa tts -Hours
Wa tts -Hours
0.05692
107
44.26
Britis h Thermal Units /Min.
Ergs /Se c ond
Foot-Pounds /Min.
Hors e p owe r
Kg.-Calories /Min.
Britis h Thermal Units
Hors e p owe r/Hours
5.204
0.03613
1.341 x 10–3
0.01434
3.415
1.341 x 10–3
4 8
AE99
Density Correction Chart
4 9
AE99
Physical Laws for Blower Applications
In the following formulae these symbols are used:
“Standard Air”-Air at 68O F (absolute temperature 528O) and
29.92” Hg. (barometric pressure at sea level). The density of
such air is 0.075 lbs./cu. ft. and the specific volume is 13.29
cu. ft./lb. The specific gravity is 1.0.
P-Pressure in pounds per square inch (PSI) or inches of
mercury column (inches Hg)
CFM-Volume in cubic feet per minute
RPM-Speed in revolutions per minute
D-Density in pounds per cubic foot (lbs./cu. ft.)
H-Height of air or gas column (ft.)
The outlet pressure of a blower depends on the condition of
the air or gas at the inlet. The inlet condition is influenced by:
a-Specific gravity (the ratio of density of the gas to density
of standard air)
SG-Specific Gravity (ratio of density of gas to the density
of air)
b-Altitude (location of blower)
c-Temperature of inlet air
Basic Fan Laws Chart
VARIABLE
VOLUME
PRESSURE
HORSEPOWER
WHEN SPEED CHANGES Varies DIRECT with Speed Ratio Varies with SQUARE of Speed Ratio Varies with CUBE of Speed Ratio
2
3
RPM2
( )
RPM1
RPM2
RPM2
CFM2 = CFM1
P2 = P1
HP2 = HP1
( )
( )
RPM1
RPM1
WHEN DENSITY CHANGES
Does Not Change
Varies DIRECT with Density Ratio
Varies DIRECT with Density Ratio
D2
D2
P2 = P1
HP2 = HP
( )
1 ( )
D1
D1
Volume
The Volume changes in direct ratio to the speed.
V = Original Volume (1000 CFM)
1
Example – A blower is operating at 3500 RPM and delivering
1000 CFM. If the speed is reduced to 3000 RPM, what is the
new volume?
V = New Volume
2
RPM1 = Original Speed (3500 RPM)
RPM2 = New Speed (3000 RPM)
1
1
RPM2
3000
V = V
= 1000 x
= 1000 x .857 = 857 CFM
( )
(3500 )
2
1
RPM1
Pressure
Pressure (barometric) varies in direct proportion
to altitude.
Let: V = Volume of standard air (1000 CFM)
1
Example – A blower is to operate at an elevation of 6000 feet
and is to deliver 3 PSI pressure. What pressure (standard air)
blower is required?
V = Volume of thinner air
2
Hg1 = Barometric pressure sea level (29.92)
Hg2 = Barometric pressure 6000’ (23.98)
29.92
Pressure = 3 x
= 3.75 or 3 3/4 PSI
Hg1
Hg2
29.92
23.98
23.98
V = V1 x
= 1000 x
= 1248 CFM
2
If it is desired to determine what pressure a 3 PSI (standard
air) blower will deliver at 6000 feet –
The pressure changes as the square of the
speed ratio.
23.98
Pressure = 3 x
= 2.4 or about 2 1/2 PSI
29.92
Example – A blower is operating at a speed of 3500 RPM and
delivering air at 5.0 PSI pressure. If the speed is reduced to
3000 RPM, what is the new pressure?
When a blower is to operate at a high altitude it is frequently
specified that the blower be capable of handling a given
volume of “standard air”. It is then necessary to determine
the equivalent volume of air at the higher altitude.
P1 = Original Pressure (5 PSI)
P2 = New Pressure
Example – A blower is to operate 6000 feet altitude and is to
handle 1000 CFM of standard air. What is the CFM of air the
blower must handle at 6000 feet altitude?
RPM1 = Original Speed (3500 RPM)
RPM2 = New Speed (3000 RPM)
RPM2
2
2 = 5 x .735 = 3.68 PSI
3000
P2 = P1
= 5 x
( ) (3500 )
RPM1
5 0
AE99
The Air Density varies in inverse proportion to the
absolute temperature.
Example – A blower is to handle 200O F air at 3 PSI pressure.
What pressure (standard air) blower is required?
Pressure varies in direct proportion to the density.
Example – A 3 PSI (standard air) blower is to be used to
handle gas having a specific gravity of 0.5. What pressure
does the blower create when handling the gas?
Let: P1 = Pressure hot air (3 PSI)
Let: Pa
Pg
=
=
=
Air pressure (3 PSI)
Gas pressure
Specific gravity of gas (0.5)
P2 = Pressure standard air
SG
AT1 = Absolute temperature hot air (200+460=660O F)
AT2 = Absolute temperature standard air (68+460=528O F)
Pg = Pa x SG = 3 x .5 = 1.5 PSI
AT1
AT2
660
528
If we are required to handle a gas having a specific gravity of
0.5 at 1.5 PSI pressure, we can determine the standard air
pressure blower as follows:
P2 = P1 x
= 3 x
= 3.75 or 3 3/4 PSI
Pg
1.5
.5
A blower is capable of delivering 3 PSI pressure with
standard air. What pressure will it develop handling 200O F
inlet air?
Let: Pa =
=
= 3 PSI
SG
AT2
AT1
528
660
P1 = P2 x
= 3 x
= 2.4 or about 2 1/2 PSI
Horsepower
The horsepower changes as the cube of the speed
ratio.
Horsepower vs. Specific Gravity & Ratio of Density.
The horsepower varies in direct proportion to the specific
gravity (ratio of density of gas to density of air).
Example – A blower is operating at a speed of 3500 RPM and
requiring 50 horsepower. If the speed is reduced to 3000
RPM, what is the new required horsepower?
Example – A standard air blower requires a 10 HP motor.
What horsepower is required when this blower is to handle a
gas whose specific gravity is 0.5?
HP1 = Original Horsepower (50)
HP2 = New Horsepower
HP = 10 x 0.5 = 5 horsepower
RPM1 = Original Speed (3500 RPM)
RPM2 = New Speed (3000 RPM)
It is possible that several of the above modifications may be
required on one installation. Therefore, it may be necessary
to use various combinations of these formulae.
RPM2
3000
3
3
HP = HP x
= 50 x
= 50 x .630 = 31.5 horsepower
( ) ( )
2
1
0
350
RPM1
5 1
AE99
AMETEK Global Operations
AMETEK Aerospace
S ENS ORS /MONITORING S YS TEMS • www.ametek.com/aerospace
50 Fordham Road • Wilmington, MA 01887 U.S.A.
AMETEK elektromotory s.r.o.
ul. Beloveska 318 • Nachod 54701 Czech Republic
Tel:420-441-23877 • Fax:420-441-23111
Tel:978-988-4101 • Fax:978-988-4944
Shaded pole induction motors for heating and ventilation, thru-flow and bypass vacuum cleaner
motors, and universal series drive motors.
Sensors and interconnects for engines, airframes, launch vehicles and satellites, including fuel
flow, temperature, speed, pressure and liquid level. Monitoring systems, including vibration.
Digital bus adapters.
AMETEK GmbH
Weilimdorfer Str. 47 • D-70825 Korntal-Munchingen Germany
Tel:+49-711-838-7876 • Fax:+49-711-838-7862
Sales for Electromechanical Group—Europe.
AVIONICS • www.ametek.com/aerospace
900 Clymer Avenue • Sellersville, PA 18960 U.S.A.
Tel:215-257-6531 • Fax:215-257-1888
Data acquisition and interface units for avionics systems. Engine indicating systems. RVSM
altimeters. Fuel/hydraulic/water quality measuring systems.
AMETEK Italia S.r.l.
GULTON-STATHAM Produc ts • www.gultonstatham.com
1644 Whittier Avenue • Costa Mesa, CA 92627 U.S.A.
CIARAMELLA • www.ametek.it
Via De Barzi • Robecco Sul Naviglio 20087 Italy
Tel:949-642-2400 • Fax:949-642-9490
Tel:+39-02-946931 • Fax:+39-02-94970518
Pressure, proximity and position sensors for aircraft, engines, airborne and land-based launch
vehicles, satellites, and industrial applications angle of attack sensors and stall warning
computers. Mud density and smart recording transmitters for oil and gas drilling.
Universal series drive motors for outdoor power equipment, small household appliances, floor
care and personal care products, and special applications.
VACUUM Produc ts • www.ametek.it
SERVICE OPERATIONS
Via De Gasperi 18/A • Ripalta Cremasca 26010 Italy
Tel:+39-0373-2101 • Fax:+39-0373-268200
Thru-flow and bypass vacuum motors for household,commercial,industrial canister,and upright
vacuum cleaners.
Distribution and Warehousing Operation • www.ametek.com/aerospace
Wilmington Service Center • 50 Fordham Road • Wilmington, MA 01887 U.S.A.
Tel:Warehouse 978-988-4100,Service:978-988-4729
Fax: Warehouse: 978-988-4720, Service: 978-988-4408
Distribution of aerospace and industrial instruments, sensors, and spare parts. Maintenance of
instruments manufactured by AMETEK Aerospace. FAA Repair Station No. A8PR-221J.
AMETEK Lamb Electric
www.ameteklamb.com
Seattle Support Center • www.ametek.com/aerospace
4560 150th Avenue NE • Redmond, WA 98052 U.S.A.
Tel:425-881-1172 • Fax:425-881-7292
Maintenance of instruments manufactured by AMETEK Aerospace. FAA Repair Station No.
HU6R600N.
627 Lake Street • Kent, OH 44240 U.S.A.
Tel:330-673-3451 • Fax:330-673-8994
Motors and motor-blower systems for industrial, commercial, and household vacuum cleaners,
ACUSTEK® motors, related floor-care equipment, and other applications such as paint sprayers,
material transport, spas, and outdoor power equipment, requiring a vacuum, pressure, or drive
source.
AMETEK Chemical Products
AMETEK Motors Shanghai Co. Ltd.
#1 AMETEK Road • Jiu Ting Economic Development Zone, Shanghai 201615 China
Tel:86-21-5763-2408 • Fax:86-21-5763-2411
HAVEG • www.ametek.com/haveg • E-mail:haveg@ametek.com
900 Greenbank Road • Wilmington, DE 19808 U.S.A.
Tel:302-995-0400,800-441-7777 • Fax:302-995-0491
SILTEMP®,ULTISIL®,HAVEGLAS™ high-thermal-resistance fabrics for welding blankets,
furnace curtains, and insulation. FLEXSIL® molten metal filters. Corrosion-resistant HAVEG®
tanks, towers, valves, and piping. Fluoropolymer tubing and Heat Exchangers of TEFLON*.
Fractional horsepower electric motors and blowers for Asian and
worldwide markets.
AMETEK Power and Industrial Products
www.ametek.com/power • E-mail:power.industrial@ametek.com
50 Fordham Road • Wilmington, MA 01887 U.S.A.
WESTCHESTER PLASTICS • www.ametek-westchesterplas.com
Green Acres Industrial Park • Nesquehoning, PA 18240 U.S.A
Tel:570-645-2191 • Fax:570-645-8564
Custom color compounding of elastomers, blends, reactive modifiers and other thermoplastic
resins. Small scale pilot runs through commercial production runs. Custom color matching
services.
Tel:978-988-4101 • Fax:978-988-4179
Temperature,pressure,speed and flame sensors and interconnects for land,marine,and utility
gas turbines and industrial boilers and burners.Gulton-Statham pressure,mud density,and
smart recording transmitters for oil and gas drilling.
AMETEK Dixson
AMETEK Precision Instruments Europe GmbH
Rudolf-Diesel-Strasse 16 • D-40670 Meerbusch Germany
Tel:+49-2159-9136-0 • Fax:+49-2159-9136-39
DIXSON • www.ametekdixson.com
287 27 Road • Grand Junction, CO 81503 U.S.A.
Tel:888-302-0639,970-242-8863 • Fax:970-245-6267
OEM instrumentation and data collection units for the heavy duty vehicular market. Industrial
bargraph panel meters for commercial and nuclear applications. Process controls and
controllers for the fast-food preparation industry.
Sales for Electronic Instruments Group—Europe and for AMETEK Rotron
Technical Motor Division—Europe.
AMETEK Precision Instruments France SARL
3 Avenue des Coudriers, Z.A. de l’Observatoire • Montigny Le Bretonneux 78180 France
Tel:33 1 30 64 89 70 • Fax:33 1 30 64 89 79
NATIONAL CONTROLS CORP. (NCC) • www.nationalcontrols.com
1725 Western Drive • West Chicago, IL 60185 U.S.A.
Tel:630-231-5900,800-323-2593 • Fax:630-231-1377
Time delay relays, temperature monitors and controls, solid state relays and voltage monitors,
liquid level controls,and dust collectors/controls for the food industry,refrigeration,HVAC, test
chambers, and other industrial applications.
Sales for Electronic Instruments Group—France and for AMETEK Rotron
Technical Motor Division—France.
AMETEK Precision Instruments (UK) Ltd.
www.ametek.co.uk • E-mail: sales@ametek.co.uk
PANALARM • www. panalarm.com
1725 Western Drive • West Chicago, IL 60185 U.S.A.
Tel:847-675-2500 • Fax:847-675-3011
2 Queens Drive, Kings Norton Business Centre • Kings Norton, Birmingham B30 3HH England
Tel:44-121-246-2260 • Fax:44-121-246-2270
Sales for Electronic Instruments Group—United Kingdom and Ireland.
Sales for Panalarm annunciator products—Europe, Middle East, Africa,
Pakistan and India. Sales for Thermox products—United Kingdom and Ireland.
Process monitoring annunciators, control room graphic displays, and high-speed event
recorders for petrochemical refineries, electrical generation and distribution, airport and train
event monitoring, water and wastewater treatment plants.
AMETEK Corporate Office
www.ametek.com
Station Square • Paoli, PA 19301 U.S.A.
Tel:610-647-2121,800-473-1286 • Fax:610-296-3412
5 2
AMETEK Process & Analytical Instruments
AMETEK Specialty Metal Products
METAL STRIP a nd SPECIALTY WIRE • www.ametekmetals.com
21Toelles Road • Wallingford, CT 06492 U.S.A.
PROCESS INSTRUMENTS • www.ametekpi.com
455 Corporate Blvd. • Newark, DE 19702 U.S.A.
Tel:302-456-4400,800-222-6789 • Fax:302-456-4444
Tel:203-265-6731,800-233-2266 • Fax:203-265-6407
Continuous on-line photometric and trace moisture analyzers used for advanced process control,
emissions monitoring, and product quality improvement. Markets include chemical
manufacturing,semiconductor,and special packaging.
Wrought powder metallurgy for engineered custom metal strip and wire including SEALVAR®
iron-nickel cobalt, custom shaped wire, metal matrix composites including HIVOL™ silicon
carbide aluminum, and fully dense components (FDC). FDC include vacuum sputtering targets for
thin film deposits through the ISOFORM™ technology using the Pneumatic Isostatic Forging
process. Product applications include satellites, land-and sea-based radar systems, computers,
chip mounting, heat sinks, and reflective coatings.
THERMOX Bus ine s s Unit • www.thermox.com
150 Freeport Road • Pittsburgh, PA 15238 U.S.A.
Tel:412-828-9040 • Fax:412-826-0399
THERMOX®oxygen analyzers for flue gas and industrial gas applications, combustion analyzers
for measuring oxygen and combustibles in a single analyzer,CO monitors,and premix gas
analyzers.
AMETEK Shanghai (SPL)
Room 16B5, Harvest Bldg. • #585 Long Hua Xi Road, Shanghai 200232 China
Tel:86-21-6428-4067,86-21-6469-8814• Fax:86-21-6487-5329
Representative Office of AMETEK Singapore Pte. Ltd.
WESTERN RESEARCH • www.ametekpi.com
8 Manning Close N.E. • Calgary, Alberta T2E7N5 Canada
Tel:403-235-8400 • Fax:403-248-3550
AMETEK Singapore Pte. Ltd.
10 Ang Mo Kio Street 65 • #05-12 TECHPOINT 569059 Singapore
Tel:65-484-2388 • Fax:65-481-6588 • E-mail:aspl@ametek.com.sg
Sales for all AMETEK products—Pacific Rim.
Sulfur Recovery Unit process monitoring, control, and emissions analyzers to measure air
demand, SO , H S, NO concentrations. Dewpoint monitors, tunable diode laser spectrometers,
2
2
x
and temperature monitors.
AMETEK Rotron
AMETEK Test and Calibration Instruments
COMMERCIAL BRUSHLESS Produc ts • www.ametektmd.com
627 Lake Street • Kent, OH 44240 U.S.A.
CHATILLON® Fo rc e Me a s u re m e n t P ro d u c t s
8600 Somerset Drive • Largo, FL 33773 U.S.A.
• www.chatillon.com
Tel:330-673-3452 • Fax:330-678-8227
Brushless DC motors, WINDJAMMER® and MINIJAMMER® motor-blowers, and low-voltage
controllers for computers, business machines, medical devices, pumps and compressors,
industrial equipment, and such mass-transit vehicles as transit buses, rail cars, and
locomotives.
Tel:727-536-7831,800-527-9999 • Fax:727-539-6882
Force gauges, universal testing machines, and material test instruments,
automated testing software, gripping fixtures and accessories.
AMETEK De nm a rk A/S • www.ametek.com/tci
Gydevang 32-34, PO Box 30 • DK-3450 Allerod Denmark
Tel:45-4816-8000 • Fax:45-4816-8080
JOFRA temperature and pressure calibrators and FRODE PEDERSEN sensors
(also markets other AMETEK instrument products throughout Europe).
MIL-AERO Produc ts • www.rotron.com
9 Hasbrouck Lane • Woodstock, NY 12498 U.S.A.
Tel:914-679-2401 • Fax:914-679-7080
AC and brushless DC fans and blowers, heat exchanger and blower systems, fault detection
devices, and electronic power conversion devices for the military and aerospace markets.
Repair of products manufactured byAMETEK RotronTechnical Motor Division. FAA Repair
Station No. AN1R014K.
LLOYD INSTRUMENTS™ Ma te ria l Te s ting Produc ts
www.lloyd-instruments.co.uk
12 Barnes Wallis Road, Segensworth East • Fareham, Hampshire PO15 5TT England
Tel:44-1489-574221 • Fax:44-1489-885118
INDUSTRIAL Produc ts a nd BIOFILTRATION Produc ts • www.rotron.com
75 North Street • Saugerties, NY 12477 U.S.A.
Materials testing machines, force gauges and test stands, melt flow indexers, friction testers, melt
viscometer, density column,plastic film impact testers,and heat distortion equipment (HDT/VICAT).
Tel:914-246-3401 • Fax:914-246-3802
IndustrialProducts:Regenerative air blowers for pressure and vacuum applications
up to 1800 SCFM and 10 PSIG servicing the Industrial, Environmental, Instrumentation, &
Telecommunication markets.Typical applications include solution agitation & aeration,pneumatic
conveying, part hold-down and pick up, part blow off, gas & fume extraction, and process gas
handling. BiofiltrationProducts:Patented modular Biofiltration systems that remove noxious
odors and vapors from gaseous exhaust and air supply systems in commercial, municipal
wastewater,and industrial applications.
MANSFIELD & GREEN Produc ts • www.ametek.com/tci
8600 Somerset Drive • Largo, FL 33773 U.S.A.
Tel:727-536-7831,800-527-9999 • Fax:727-539-6882
Electronic tachometers and stroboscopes, force and torque gauges, deadweight testers, pressure
calibrators, diaphragm seals, and air/noise monitoring instruments.
AMETEK U.S. Gauge
AMETEK Sensor Technology
U.S. GAUGE Produc ts • www.ametekusg.com
PATRIOT Produc ts • www.patriotsensors.com
900 Clymer Ave. • Sellersville, PA 18960 U.S.A.
Tel:215-257-6531 • Fax:215-257-3058
Pressure and temperature gauges for industrial use, process industries, and OEM applications.
Pressure gauges for compressed gas, welding, and medical applications. Solid front pressure
gauges and diaphragm seals for chemical, petrochemical, and other process industries. Hunter
Spring NEG’ATOR® and SPIR’ATOR® constant force springs and spring powered retracting reels.
1080 N. Crooks Road • Clawson, MI 48017-1097 U.S.A.
Tel:248-435-0700 • Fax:248-435-8120
Position sensors including rotary cam limit switches, programmable limit switches, linear
position sensors and rotary encoders; programmable controller bus cards including ultra-high
speed programmable limit switches and electronic encoders for linear and rotary inputs;
stamping press automation including shut height monitors; specialty products including cable and
hose carrier systems. Point level sensor products including conductivity sensors, conductivity
relays and magnetic probes; continuous level sensors including magnetostrictive probes for tank
gauging and leak monitoring.
PMT Produc ts • www.ametekusg.com
820 Pennsylvania Blvd. • Feasterville, PA 19053 U.S.A.
Tel:215-355-6900,888-625-5895 • Fax:215-355-2937
Pressure transducers and transmitters for industrial markets, pressure gauges, switches,
transmitters, displays and cylinder sales for UHP semiconductor manufacturing markets, level
measurement systems, pneumatic controllers, and gas energy content (BTU) meters.
DREXELBROOK Produc ts • www.drexelbrook.com
205 Kieth Valley Road • Horsham, PA 19044 U.S.A.
Tel:215 674-1234• Fax:215 674-2731
RF and ultrasonic level sensors in a broad range of packages for chemical,petrochemical,water,
waste water,food,beverage and pharmaceutical monitoring; continuous and point level sensors;
IS and EX applications; line powered, low voltage, 4-20mA loop powered, HART and other
networked outputs. Clarifier and sludge blanket sensor systems for wastewater applications.
Level sensors for aerospace applications.
AMEKAI Taiwan Co., Ltd.
2-Floor, No. 214Alley 1 • Lane 138, Chang-An Street • Pan-Chiao,TaipeiTaiwan
Tel:886-2-2954-1765 • Fax:886-2-2951-3443
Joint venture withTaiwanese partner.General industrial use mechanical
pressure gauges for Asian and worldwide markets.
AMETEK Specialty Metal Products
AMEKAI Meters (XIAMEN) Co., Ltd.
1-2 Floors, Chuang Xin Bldg.,Torch High Technology Industrial Zone
Innovate City, Xiamen, Fujian 361006 China
CLAD METALS a nd METAL POWDERS • www.ametekmetals.com
Route 519 • Eighty Four, PA 15330 U.S.A.
Tel:724-225-8400 • Fax:724-225-6622
Stainless steel and nickel clad alloys used in high-quality cookware, sterilizers and chemical
processing equipment. Stainless steel, cobalt, and nickel alloy metal powders for powder
Tel:86-592-603-0565 • Fax:86-592-603-0570
Joint venture with Chinese partner.General industrial use mechanical
pressure gauges for Asian and worldwide markets.
metallurgy,hardfacing,metal injection molding, polymer filtration,and plastic compounding.
5 3
Co n t a c t In fo rm a t io n
ROTRON
Technical Products
627 Lake Street
Kent, OH 44240
Main Tel: (330) 673-3452
Fax: (330) 678-8227
www.ametektmd.com
e-mail: info@ametektmd.com
AMETEK GmbH
Weilimorder Str. 47
70825 Korntal-Munchingen
Germany
Main Tel: 49-711-838-7876
Fax: 49-711-838-7862
Dis t rib u t o rs
Allied Electronics
1-800-433-5700
www.allied.avnet.com
Grainger
1-800-323-0620
www.grainger.com
54
AMETEK, Inc.
AMETEK is a leading global manufacturer of electrical and electromechanical products for niche markets.
Listed on the New York Stock Exchange (AME) since 1930, AMETEK’s annual sales are approaching $1
billion. Operations are in North America, Europe, and Asia, with about one-third of sales to markets outside
the United States. AMETEK is serving its customers with investments in new products, global and market
expansion, strategic acquisitions, and operational excellence. The Company’s operating groups are
Electronic Instruments and Electromechanical.
Rotron
The Electromechanical Group (EMG) is one of the world’s largest producers of high-speed electric motor
products for original equipment manufacturers (OEMs). In business since 1915, EMG is using its core
competencies to enhance its worldwide presence. A business unit of AMETEK EMG, Rotron has facilities
in California, New York, North Carolina, and Ohio. Rotron serves the military, aerospace, medical,
transportation, office equipment, industrial, and environmental markets worldwide. Rotron supports its
customers with more than 650 employees that are organized in three business segments:
• Technical Products
• Military & Aerospace Products
• Industrial Products
Technical Products
Rotron’s standard product lines of brushless DC motors, blowers, and controllers offer a wide range of
application demands. Brushless DC motors and blowers are an ideal choice for such varied applications
as medical instruments, robotics, pumps, compressors, office equipment, fans, machine tools, tape drives,
or any other precise rotary motion/air delivery applications. If there is a need for a product with unique
performance, mounting environment, or agency requirements, Rotron can supply the solution.
ROTRON
Technical Products
627 Lake Street, Kent, Ohio 44240
Telephone: 330-673-3452 • Fax: 330-678-8227 • www.ametektmd.com
©2000, by AMETEK, Inc.
5M200N (140044)
相关型号:
1190550
2.36mm (.093") Diameter, Standard .093" Pin and Socket Crimp Terminal, Series 1190, Male, with Gold (Au) Plated Brass Contact, 14-20 AWG, Reel
MOLEX
1190591
2.36mm (.093") Diameter, Standard .093" Pin and Socket Crimp Terminal, Series 1190, Male, with Selective Gold (Au) Plated Brass Contact, 14-20 AWG, Reel
MOLEX
1190P591L
2.36mm (.093") Diameter, Standard .093" Pin and Socket Crimp Terminal, Series 1190,Male, with Selective Gold (Au) Plated Brass Contact, 14-20 AWG, Bag
MOLEX
1190T
2.36mm (.093") Diameter, Standard .093" Pin and Socket Crimp Terminal, Series 1190, Male, with Tin (Sn) over Copper Plated Brass Contact, 14-20 AWG, Reel
MOLEX