75 Watt HE Single Series DC/DC Converters
Features
!
!
!
Small Size 2.4" x 2.28" x 0.55"
Industry Standard Pinout
Excellent Thermal Performance
with Metal Baseplate
!
!
High Efficiency
Volt-seconds Clamp and Fast
Over Voltage Clamp
!
Pulse-by-pulse Current Limiting, Short Circuit
Frequency Foldback, Dead Short Shutdown
Over-temperature Protection
Auto-softstart
!
!
!
!
!
!
!
!
!
!
Low Noise
Planar Magnetics
Constant Frequency for Normal Operation
More than 2:1 Input Voltage Range
Remote Sense
Description
The 75 watt single HE series DC/DC converters provide
precisely regulated dc outputs. All outputs are fully isolated
from the inputs, allowing the output to be used with positive or
negative polarity and various grounding options. The HE
series meets the most rigorous requirements in an industry
standard case size for industrial process control and telecom
applications.
Remote ON/OFF
Super Energy Saving, 2 mA Input Idle Current
Output Trim with Very Low Temperature
Coefficient
!
!
!
!
!
!
Water Washable, Wide Humidity Applications
Shock & Vibration Damping
Low Cost
Standard features include remote sensing, output trim, and
remote on/off. Threaded-through holes are provided to allow
easy mounting or to add a heat sink for extended temperature
use.
Undervoltage Lockout
Input Reverse Voltage Protection
5 Year Warranty
Selection Chart
V in nom
VDC
I in
ADC
V out
VDC
I out
ADC
Model
12S3.15HE
12S5.15HE
24S3.15HE
24S5.15HE
24S12.6HE
24S15.5HE
24S24.3HE
48S3.15HE
48S5.15HE
48S12.6HE
48S15.5HE
48S24.3HE
12
12
24
24
24
24
24
48
48
48
48
48
5.03
7.35
2.52
3.63
3.59
3.55
3.55
1.24
1.80
1.78
1.76
1.76
3.3
5
15
15
3.3
5
15
15
12
15
24
3.3
5
6.25
5
3.13
15
A
15
12
15
24
6.25
5
3.13
NOTES:
Efficiencies up to 88%.
Default ON/OFF logic is positive.
Add -N to the model number to order negative ON/OFF logic.
2401 Stanwell Drive
•
Concord, California 94520
•
Ph: 925/687-4411 or 800/542-3355
•
Fax: 925/687-3333
•
www.calex.com
•
Email: sales@calex.com
12/23/2002
1
75 Watt HE Single Series DC/DC Converters
Unless otherwise stated, these specifications apply for ambient temperature TA=23 ±2°C, nominal input voltage, and rated full load. (1)
Input Parameters
Model
12S3.15HE
12S15.5HE
Units
9
12
18
MIN
TYP
MAX
Voltage Range
VDC
Input Ripple Rejection
(120Hz)
TYP
60
dB
Undervoltage Lockout
Yes
Yes
Input Reverse Voltage Protection
Input Current No Load TYP
100% Load
15
5.03
15
7.35
mA/A
A2S
TYP
Inrush Current
MAX
0.5
20
Reflected Ripple, 12µH
Source Impedance (2)
TYP
mA P-P
Efficiency
TYP
TYP
82
85
%
Switching Frequency
440
25
kHz
Maximum Input Overvoltage
100 ms Maximum
MAX
VDC
Recommended Fuse
(3)
AMPS
Model
24S3.15HE
24S5.15HE
24S12.6HE
24S15.5HE
24S24.3HE
Units
MIN
TYP
MAX
18
24
36
Voltage Range
VDC
dB
Input Ripple Rejection
(120Hz)
TYP
60
Undervoltage Lockout
Yes
Yes
Input Reverse Voltage Protection
Input Current No Load TYP
100% Load
mA
A
12
2.52
12
3.63
12
3.59
12
3.55
12
3.55
TYP
Inrush Current
MAX
0.5
20
A2S
Reflected Ripple, 12µH
Source Impedance (2)
TYP
mA P-P
Efficiency
TYP
TYP
82
86
87
88
88
%
Switching Frequency
440
50
kHz
Maximum Input Overvoltage*
100 ms Maximum
MAX
VDC
Recommended Fuse
(3)
AMPS
Model
48S3.15HE
48S5.15HE
48S12.6HE
48S15.5HE
48S24.3HE
Units
MIN
TYP
MAX
36
48
75
Voltage Range
VDC
dB
Input Ripple Rejection
(120Hz)
TYP
60
A
Undervoltage Lockout
Yes
Yes
Input Reverse Voltage Protection
Input Current No Load TYP
100% Load
mA
A
12
1.24
12
1.80
12
1.78
12
1.76
12
1.76
TYP
Inrush Current
MAX
0.5
20
A2S
Reflected Ripple, 12µH
Source Impedance (2)
TYP
mA P-P
Efficiency
TYP
TYP
83
87
88
89
89
%
Switching Frequency
440
85
kHz
Maximum Input Overvoltage*
100 ms Maximum
MAX
VDC
Recommended Fuse
(3)
AMPS
2401 Stanwell Drive
•
Concord, California 94520
•
Ph: 925/687-4411 or 800/542-3355
•
Fax: 925/687-3333
•
www.calex.com
•
Email: sales@calex.com
12/23/2002
2
75 Watt HE Single Series DC/DC Converters
Output Parameters
12S3.15HE
24S3.15HE
48S3.15HE
12S5.15HE
24S5.15HE
48S5.15HE
24S12.6HE
48S12.6HE
24S15.5HE
48S15.5HE
24S24.3HE
48S24.3HE
Model
Units
Output Voltage
3.3
5
12
15
24
VDC
%
Output Voltage
Setpoint Accuracy
MAX
±1
0
Turn On Overshoot
TYP
TYP
MAX
%
0.005
0.01
0.003
0.005
Temperature Coefficient
%/°C
Noise (8)
MAX
TYP
75
20
75
20
150
60
150
60
250
100
mV P-P
RMS Noise
mV RMS
MIN
MAX
5
100
% I out
rated
Load Current (4)
Load Transient Overshoot (7)
TYP
TYP
2.5
%
Load Transient Recovery Time (6)
100
µSec
Load Regulation (5)
Min-Max Load
TYP
MAX
0.02
0.2
%
%
Line Regulation
Vin = Min-Max
TYP
MAX
0.01
0.1
Overvoltage Protection (OVP)
Threshhold
OVP Type - Non-latching
Open Loop Overvoltage Clamp
Output Current Limit
V out=90% of V out-nom
Output Short Circuit Protection
V out = 0.25 V
TYP
MAX
120
135
%
TYP
120
%
%
TYP
MAX
140
150
Mounting inserts
M3 x 0.5 though
4 places
A
2.28
1.90
Ø
0.080
Pin
1
Function
-INPUT
CASE
1
2
1.400
1.000
1.400
5
2
1.000
0.700
0.400
6
7
8
3
ON/OFF
+INPUT
-OUTPUT
-SENSE
TRIM
4
5
3
4
0.400
0.000
6
0.000
9
Ø
0.040
7
8
+SENSE
+OUTPUT
0.50
9
BOTTOM VIEW
SIDE VIEW
2401 Stanwell Drive
•
Concord, California 94520
•
Ph: 925/687-4411 or 800/542-3355
•
Fax: 925/687-3333
•
www.calex.com
•
Email: sales@calex.com
12/23/2002
3
75 Watt HE Single Series DC/DC Converters
NOTES:
General Specifications
(1) Refer to the CALEX Application Notes for the definition of terms,
measurement circuits, and other information.
All Models
Units
Remote ON/OFF Function
(2) 33 µF capacitor connected to two “Input” pins. Then place
current sensor in series with 12 µH inductor between 33 µF and
source. The reflected ripple current is measured over 5 Hz to
HIGH Logic Level
or Leave Pin Open
External Leakage Current
for Logic High
MAX
MAX
MAX
MIN
3.0
10
VDC
µA
20 MHz bandwidth.
(3) Refer to the CALEX Application Notes for information on fusing.
Input Diode Protection
Voltage
50
VDC
VDC
µA
(4) Optimum performance is obtained when this power supply is
operated within the minimum to maximum load specifications.
No damage to module will occur, when the output is operated at
less than minimum load, but the output voltage may contain a
low frequency component that may exceed output noise
specifications.
LOW Logic Level
or Tie ON/OFF Pin to -Input
Sinking Current for
Logic Low
1.0
500
MAX
Open Circuit Voltage (10)
Positive Logic
(5) Load regulation is defined as the output voltage change when
changing load current from maximum to minimum.
TYP
TYP
TYP
2.3
1.5
3
VDC
VDC
k Ohm
Negative Logic
Output Resistance
Idle Current
(6) Load Transient Recovery Time is defined as the time for the
output to settle from a 50 to 75% step load change to a 1% error
band (rise time of step = 2µSec).
TYP
TYP
2
mADC
mSec
(Module is OFF)
Turn-on Time to 1% error
(7) Load Transient Overshoot is defined as the peak overshoot
during a transient as defined in the Note 6 above.
20
HIGH - Module ON
LOW - Module OFF
HIGH - Module OFF
LOW - Module ON
Positive Logic
Negative Logic
(8) Noise is measured per the CALEX Application Notes. Output
noise is measured with a 10µF tantalum capacitor in parallel with
a 0.1 µF ceramic capacitor connected across the output to CMN.
Measurement bandwidth is 0-20 MHz.
Output Voltage Remote Sensing
(9) When an external On/Off switch is used, such as open collector
switch, logic high requires the switch to be high-impedance.
Switch leakage currents greater than 10 uA may be sufficient to
trigger the ON/Off to the logic-low state.
Maximum Voltage Drops
MAX
0.5
VDC
%
on Leads
Line Regulation Under
Remote Sensing
Load Regulation Under
Remote Sensing
TYP
MAX
TYP
MAX
0.02
0.1
0.05
0.2
(10) Most switches would be suitable for logic On/Off control, in case
there is a problem, you can make following estimations and then
leave some margins.
%
Output Voltage Trim
When open collector is used for logic high, “Open Circuit Voltage
at On/Off Pin”, “Output Resistance” and “External Leakage
Current Allowed for Logic High” are used to estimate the high
impedance requirement of open collector.
MIN
MAX
TYP
TYP
-10
+10
10
% of
Vout
kohm
V
Trim Range
Input Resistance
Open Circuit Voltage
2.5
When switch is used for logic low, “Open Circuit Voltage at On/
Off Pin”, “Output Resistance” and “LOW Logic Level” are used
to estimate the low impedance requirement of switch.
Sense and Trim Limit
Maximum Output Voltage
Isolation
% of
Vout
TYP
110
(11) Specifications subject to change without notice.
Input to Output Isolation*
10µA Leakage
V nom =12 V, 24 V
V nom = 48 V
Input to Output Resistance
MAX
MAX
TYP
700
1500
10
VDC
VDC
M ohm
pF
Input to Output Capacitance TYP
1800
A
Environmental
Calculated MTBF, Bellcore
Method 1, Case 1
106
Hr
Baseplate Operating
Temperature Range
MIN
MAX
-40
100
°C
MIN
MAX
-40
120
Storage Temperature
°C
Thermal Impedance
TYP
7
°C/W
Thermal Shutdown
Baseplate Temperature
(Auto Restart)
MIN
TYP
100
110
°C
General
Unit Weight
TYP
4/114
oz/g
Case Dimension
Approvals (pending)
Chassis Mounting Kit
2.4" x 2.28" x 0.55"
UL1950, CUL, EN60950 (TUV)
MS20
* Absolute Maximum Ratings. Caution: Stresses in excess of the Absolute
Maximum Ratings can cause permanent damage to the device (see Note 1).
2401 Stanwell Drive
•
Concord, California 94520
•
Ph: 925/687-4411 or 800/542-3355
•
Fax: 925/687-3333
•
www.calex.com
•
Email: sales@calex.com
12/23/2002
4
相关型号:
©2020 ICPDF网 联系我们和版权申明