1325AD151000 [ETC]
22 AWG stranded (7x30) TC conductors, plenum, Flamarrest insulation;型号: | 1325AD151000 |
厂家: | ETC |
描述: | 22 AWG stranded (7x30) TC conductors, plenum, Flamarrest insulation |
文件: | 总3页 (文件大小:98K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
1325A Multi-Conductor - Double-Pair Cable
For more Information
please call
1-800-Belden1
Description:
22 AWG stranded (7x30) TC conductors, plenum, Flamarrest® insulation, twisted pairs, individually
shielded w/Beldfoil® (100% coverage), 24 AWG stranded TC drain wire, Flamarrest® jacket.
Usage (Overall)
Suitable Applications:
Sound and Audio Systems, Intercom and PA Systems, Security Systems,
Power-Limited Control Systems
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material
2
22
7x30
TC - Tinned Copper
Insulation
Insulation Material:
Insulation Trade Name Insulation Material
Flamarrest®
F-R PVC - Flame Retardant Polyvinyl Chloride
Inner Shield
Inner Shield Material:
Inner Shield Trade Name Type Inner Shield Material
Coverage (%)
Beldfoil® (Z-Fold®)
Tape Aluminum Foil-Polyester Tape 100
Inner Shield Drain Wire AWG:
AWG
24
Outer Jacket
Outer Jacket Material:
Outer Jacket Trade Name Outer Jacket Material
Flamarrest®
LS PVC - Low Smoke Polyvinyl Chloride
Overall Cabling
Overall Nominal Diameter:
4.013 mm
Pair
Pair Color Code Chart:
Number Color
1
2
Black & Red
White & Green
Pair Lay Length & Direction:
Twists/ft. (twist/m)
8
Mechanical Characteristics (Overall)
Operating Temperature Range:
Bulk Cable Weight:
0°C To +75°C
28.276 Kg/Km
120.101 N
Max. Recommended Pulling Tension:
Page 1 of 3
05-10-2011
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
1325A Multi-Conductor - Double-Pair Cable
Min. Bend Radius (Install)/Minor Axis:
40.640 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
CMP
CMP
Yes
CEC/C(UL) Specification:
EU CE Mark:
EU Directive 2000/53/EC (ELV):
EU Directive 2002/95/EC (RoHS):
EU RoHS Compliance Date (mm/dd/yyyy):
EU Directive 2002/96/EC (WEEE):
EU Directive 2003/11/EC (BFR):
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
Yes
Yes
05/30/2006
Yes
Yes
Yes
Yes
Flame Test
UL Flame Test:
UL910 Steiner Tunnel
FT6
CSA Flame Test:
Plenum/Non-Plenum
Plenum (Y/N):
Yes
Non-Plenum Number:
8723
Electrical Characteristics (Overall)
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/m)
111.554
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
48.2307
Nom. Inner Shield DC Resistance:
DCR @ 20°C (Ohm/km)
49.215
Max. Operating Voltage - UL:
Voltage
300 V RMS
Max. Recommended Current:
Current
2.8 Amps per conductor @ 25°C
Related Documents:
No related documents are available for this product
Put Ups and Colors:
Item #
Putup
Ship Weight
9.072 KG
9.072 KG
4.763 KG
9.072 KG
Color
Notes
Item Desc
1325A D151000
1325A 0091000
1325A 009500
1325A 0101000
305 MT
305 MT
152 MT
305 MT
BLUE
C
2 FS PR #22 FLRST FLRST
2 FS PR #22 FLRST FLRST
2 FS PR #22 FLRST FLRST
2 FS PR #22 FLRST FLRST
WHITE
WHITE
BLACK
Notes:
C = CRATE REEL PUT-UP.
Page 2 of 3
05-10-2011
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
1325A Multi-Conductor - Double-Pair Cable
Revision Number: 1
Revision Date: 05-11-2010
© 2011 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3
05-10-2011
相关型号:
©2020 ICPDF网 联系我们和版权申明