24A16 [ETC]
1K/2K/4K/8K/16K-bit Serial EEPROM for Low Power; 1K / 2K / 4K / 8K / 16K位串行EEPROM用于低功耗型号: | 24A16 |
厂家: | ETC |
描述: | 1K/2K/4K/8K/16K-bit Serial EEPROM for Low Power |
文件: | 总24页 (文件大小:1832K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
24A01/24A02/24A04/24A08/24A16
TMC
1K/2K/4K/8K/16K-bit
Serial EEPROM for Low Power
Data Sheet
OVERVIEW
The TMC 24A01/24A02/24A04/24A08/24A16 serial EEPROM has a 1,024/2,048/4,096/8,192/16,384-bit
capacity, supporting the standard I2C™-bus serial interface. It is fabricated using TMC’s most advanced
CMOS technology. It has been developed for low power and low voltage applications (1.8 V to 5.5 V). One of its
major feature is a hardware-based write protection circuit for the entire memory area. Hardware-based write
protection is controlled by the state of the write-protect (WP) pin. Using one-page write mode, you can load up to
16 bytes of data into the EEPROM in a single write operation. Another significant feature of the
TMC 24A01/24A02/24A08/24A16 is its support for fast mode and standard mode.
FEATURES
I2C-Bus Interface
Operating Characteristics
·
·
Two-wire serial interface
·
Operating voltage
— 1.8 V to 5.5 V
Automatic word address increment
EEPROM
·
Operating current
— Maximum write current: < 3 mA at 5.5 V
— Maximum read current: < 200 mA at 5.5 V
— Maximum stand-by current: < 5 mA at 5.5 V
Operating temperature range
— – 25°C to + 70°C (commercial)
— – 40°C to + 85°C (industrial)
Operating clock frequencies
— 100 kHz at standard mode
— 400 kHz at fast mode
·
1K/2K/4K/8K/16K-bit
(128/256/512/1,024/2,048-byte) storage area
·
·
16-byte page buffer
Hardware-based write protection for the entire
EEPROM (using the WP pin)
·
·
·
·
EEPROM programming voltage generated
on chip
·
·
1,000,000 erase/write cycles
100 years data retention
24AXXL Marking means Lead Free product
24AXXG Marking means Green product
Electrostatic discharge (ESD)
— 5,000 V (HBM)
— 500 V (MM)
Packages
8-pin DIP, SOP, TSSOP, and SOT 25
·
1
SDA
WP
Start/Stop
Logic
HV Generation
Timing Control
Control Logic
EEPROM
Cell Array
128 x 8 bits
256 x 8 bits
512 x 8 bits
1024 x 8 bits
2048 x 8 bits
SCL
Slave Address
Comparator
Word Address
Pointer
Row
decoder
A0
A1
A2
Column Decoder
Data Register
DOUT and ACK
Figure 3-1. Block Diagram
2
VCC WP SCL SDA
SOT25
WP
Vcc
1
5
4
SCL
TMC 24A01/24A02
24A04/24A08/24A16
2
3
Vss
SDA
A0
A1
A2
VSS
NOTE:
The TMC 24A01/24A02/24A04/24A08/24A16
is available in 8-pin DIP, SOP, TSSOP, and SOT 25 package.
Figure 3-2. Pin Assignment Diagram
Table 3-1. Pin Descriptions
Description
Name
Type
Circuit
Type
A0, A1, A2
Input
Input pins for device address selection. To configure a device address,
these pins should be connected to the VCC or VSS of the device.
1
These pins are internally pulled down to VSS
.
VSS
–
Ground pin.
–
3
SDA
I/O
Bi-directional data pin for the I2C-bus serial data interface. Schmitt
trigger input and open-drain output. An external pull-up resistor must
be connected to VCC. Typical values for this pull-up resistor are 4.7 kW
(100 kHz) and 1 kW (400 kHz).
SCL
WP
Input
Input
Schmitt trigger input pin for serial clock input.
Input pin for hardware write protection control. If you tie this pin to VCC,
2
1
the write function is disabled to protect previously written data in the
entire memory; if you tie it to VSS, the write function is enabled.
This pin is internally pulled down to VSS
.
VCC
–
Single power supply.
–
NOTE: See the following page for diagrams of pin circuit types 1, 2, and 3.
3
A0, A1,
A2, WP
Noise
Filter
SCL
Figure 3-3. Pin Circuit Type 1
Figure 3-4. Pin Circuit Type 2
SDA
Data Out
Data In
VSS
Noise
Filter
Figure 3-5. Pin Circuit Type 3
4
FUNCTION DESCRIPTION
I2C-BUS INTERFACE
The TMC 24A01/24A02/24A04/24A08/24A16 supports the I2C-bus serial interface data transmission protocol.
The two-wire bus consists of a serial data line (SDA) and a serial clock line (SCL). The SDA and the SCL lines
must be connected to VCC by a pull-up resistor that is located somewhere on the bus.
Any device that puts data onto the bus is defined as the “transmitter” and any device that gets data from the bus
is the “receiver.” The bus is controlled by a master device which generates the serial clock and start/stop
conditions, controlling bus access. Using the A0, A1, and A2 input pins, up to eight TMC 24A01/24A02 (four
TMC24A04, two for TMC24A08, one for TMC24A16) devices can be connected to the same I2C-bus as
slaves (see Figure 3-6). Both the master and slaves can operate as transmitter or receiver, but the master device
determines which bus operating mode would be active.
VCC
VCC
SDA
SCL
Slave 1
TMC24A02
Slave 2
TMC 24A02
Slave 3
TMC24A02
Slave 8
Bus Master
(Transmitter/
Receiver)
TMC 24A02
Tx/Rx
A0 A1 A2
Tx/Rx
A0 A1 A2
Tx/Rx
A0 A1 A2
Tx/Rx
A0 A1 A2
MCU
To VCC or VSS
To VCC or VSS
To VCC or VSS
To VCC or VSS
NOTES:
1. The A0 does not affect the device address of the TMC 24A04
2. The A0, A1 do not affect the device address of the TMC 24A08.
3. The A0, A1, and A2 do not affect the device address of the TMC 24A16.
Figure 3-6. Typical Configuration (16 Kbits of Memory on the I2C-Bus)
5
I2C-BUS PROTOCOLS
Here are several rules for I2C-bus transfers:
— A new data transfer can be initiated only when the bus is currently not busy.
— MSB is always transferred first in transmitting data.
— During a data transfer, the data line (SDA) must remain stable whenever the clock line (SCL) is High.
The I2C-bus interface supports the following communication protocols:
·
·
Bus not busy: The SDA and the SCL lines remain High level when the bus is not active.
Start condition: Start condition is initiated by a High-to-Low transition of the SDA line while SCL remains High
level. All bus commands must be preceded by a start condition.
·
Stop condition: A stop condition is initiated by a Low-to-High transition of the SDA line while SCL remains
High level. All bus operations must be completed by a stop condition (see Figure 3-7).
SCL
SDA
Start
Data or
Data
Stop
Condition
ACK Valid Change
Condition
Figure 3-7. Data Transmission Sequence
·
·
Data valid: Following a start condition, the data becomes valid if the data line remains stable for the duration
of the High period of SCL. New data must be put onto the bus while SCL is Low. Bus timing is one clock
pulse per data bit. The number of data bytes to be transferred is determined by the master device. The total
number of bytes that can be transferred in one operation is theoretically unlimited.
ACK (Acknowledge): An ACK signal indicates that a data transfer is completed successfully. The transmitter
(the master or the slave) releases the bus after transmitting eight bits. During the 9th clock, which the master
generates, the receiver pulls the SDA line low to acknowledge that it successfully received the eight bits of
data (see Figure 3-8). But the slave does not send an ACK if an internal write cycle is still in progress.
In data read operations, the slave releases the SDA line after transmitting 8 bits of data and then monitors
the line for an ACK signal during the 9th clock period. If an ACK is detected, the slave will continue to
transmit data. If an ACK is not detected, the slave terminates data transmission and waits for a stop condition
to be issued by the master before returning to its stand-by mode.
6
Master
SCL Line
Bit 1
Bit 9
Data from
Transmitter
ACK from
Receiver
ACK
Figure 3-8. Acknowledge Response From Receiver
·
Slave Address: After the master initiates a Start condition, it must output the address of the device to be
accessed. The most significant four bits of the slave address are called the “device identifier”. The identifier
for the TMC 24A01/24A02/24A04/24A08/24A16 is “1010B”. The next three bits comprise the address of a
specific device. The device address is defined by the state of the A0, A1 and A2 pins. Using this addressing
scheme, you can cascade up to eight TMC 24A01/24A02 or four TMC 24A04 or two TMC 24A08 or one
TMC 24A16 on the bus (see Table 3-2 below). The b1 for TMC 24A04 or the b1, b2 for TMC 24A08 or the
b1, b2, b3 for TMC24A16 are used by the master to select which of the blocks of internal memory (1 block
= 256 words) are to be accessed. The bits are in effect the most significant bits of the word address.
·
Read/Write: The final (eighth) bit of the slave address defines the type of operation to be performed. If the
R/W bit is “1”, a read operation is executed. If it is “0”, a write operation is executed.
Table 3-2. Slave Device Addressing
Device
Device Identifier
Device Address
R/W Bit
b0
b7 b6 b5 b4
b3
A2
A2
A2
B2
b2
A1
A1
B1
B1
b1
A0
B0
B0
B0
TMC24A01/24A02
TMC24A04
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
R/W
R/W
R/W
R/W
TMC24A08
TMC24A16
NOTE: The B2, B1, B0 correspond to the MSB of the memory array address word.
7
BYTE WRITE OPERATION
In a complete byte write operation, the master transmits the slave address, word address, and one data byte to
the TMC 24A01/24A02/24A04/24A08/24A16 slave device (see Figure 3-9).
Start Slave Address
Word Address
Data
Stop
A
C
K
A
C
K
A
C
K
Figure 3-9. Byte Write Operation
Following the Start condition, the master sends the device identifier (4 bits), the device address (3 bits), and an
R/W bit set to “0” onto the bus. Then the addressed TMC 24A01/24A02/24A04/24A08/24A16 generates an ACK
and waits for the next byte. The next byte to be transmitted by the master is the word address. This 8-bit address
is written into the word address pointer of the TMC 24A01/24A02/24A04/24A08/24A16.
When the TMC 24A01/24A02/24A04/24A08/24A16 receives the word address, it responds by issuing an ACK
and then waits for the next 8-bit data. When it receives the data byte, the
TMC 24A01/24A02/24A04/24A08/24A16 again responds with an ACK. The master terminates the transfer by
generating a Stop condition, at which time the TMC 24A01/24A02/24A04/24A08/24A16 begins the internal write
cycle.
While the internal write cycle is in progress, all TMC 24A01/24A02/24A04/24A08/24A16 inputs are disabled and
the TMC 24A01/24A02/24A04/24A08/24A16 does not respond to additional requests from the master.
8
PAGE WRITE OPERATION
The TMC 24A01/24A02/24A04/24A08/24A16 can also perform 16-byte page write operation. A page write
operation is initiated in the same way as a byte write operation. However, instead of finishing the write operation
after the first data byte is transferred, the master can transmit up to 15 additional bytes. The
TMC 24A01/24A02/24A04/24A08/24A16 responds with an ACK each time it receives a complete byte of data
(see Figure 3-10).
Start Slave Address
Word Address (n)
Data (n)
Data (£ n + 15)
Stop
A
C
K
A
C
K
A
C
K
A
C
K
A
C
K
Figure 3-10. Page Write Operation
The TMC 24A01/24A02/24A04/24A08/24A16 automatically increments the word address pointer each time it
receives a complete data byte. When one byte has been received, the internal word address pointer increments
to the next address and the next data byte can be received.
If the master transmits more than 16 bytes before it generates a stop condition to end the page write operation,
the TMC 24A01/24A02/24A04/24A08/24A16 word address pointer value “rolls over” and the previously received
data is overwritten. If the master transmits less than 16 bytes and generates a stop condition, the
TMC 24A01/24A02/24A04/24A08/24A16 writes the received data to the corresponding EEPROM address.
During a page write operation, all inputs are disabled and there is no response to additional requests from the
master until the internal write cycle is completed.
9
POLLING FOR AN ACK SIGNAL
When the master issues a stop condition to initiate a write cycle, the TMC 24A01/24A02/24A04/24A08/24A16
starts an internal write cycle. The master can then immediately begin polling for an ACK from the slave device.
To poll for an ACK signal in a write operation, the master issues a start condition followed by the slave address.
As long as the TMC 24A01/24A02/24A04/24A08/24A16 remains busy with the write operation, no ACK is
returned. When the TMC 24A01/24A02/24A04/24A08/24A16 completes the write operation, it returns an ACK
and the master can then proceed with the next read or write operation (see Figure 3-11).
Send Write
Command
Send Stop Condition to
Initiate Write Cycle
Send Start
Condition
Send Slave Address
with R/W bit = "0"
No
ACK = "0" ?
Yes
Start Next
Operation
Figure 3-11. Master Polling for an ACK Signal from a Slave Device
10
HARDWARE-BASED WRITE PROTECTION
You can also write-protect the entire memory area of the TMC 24A01/24A02/24A04/24A08/24A16. This method
of write protection is controlled by the state of the Write Protect (WP) pin.
When the WP pin is connected to VCC, any attempt to write a value to the memory is ignored.
The TMC 24A01/24A02/24A04/24A08/24A16 will acknowledge slave and word address, but it will not generate
an acknowledge after receiving the first byte of the data. Thus the write cycle will not be started when the stop
condition is generated. By connecting the WP pin to VSS, the write function is allowed for the entire memory.
These write protection features effectively change the EEPROM to a ROM in order to prevent data from being
overwritten. Whenever the write function is disabled, a slave address and a word address are acknowledged on
the bus, but data bytes are not acknowledged.
CURRENT ADDRESS BYTE READ OPERATION
The internal word address pointer maintains the address of the last word accessed, incremented by one.
Therefore, if the last access (either read or write) was to the address “n”, the next read operation would access
data at address “n+1”.
When the TMC 24A01/24A02/24A04/24A08/24A16receives a slave address with the R/W bit set to “1”, it issues
an ACK and sends the eight bits of data. The master does not acknowledge the transfer but it does generate a
Stop condition. In this way, the TMC 24A01/24A02/24A04/24A08/24A16 effectively stops the transmission (see
Figure 3-12).
Start Slave Address
Data
Stop
A
C
K
N
O
A
C
K
Figure 3-12. Current Address Byte Read Operation
11
RANDOM ADDRESS BYTE READ OPERATION
Using random read operations, the master can access any memory location at any time. Before it issues the
slave address with the R/W bit set to “1”, the master must first perform a “dummy” write operation. This operation
is performed in the following steps:
1. The master first issues a Start condition, the slave address, and the word address to be read. (This step sets
the internal word address pointer of the TMC 24A01/24A02/24A04/24A08/24A16 to the desired address.)
2. When the master receives an ACK for the word address, it immediately re-issues a start condition followed
by another slave address, with the R/W bit set to “1”.
3. The TMC 24A01/24A02/24A04/24A08/24A16 then sends an ACK and the 8-bit data stored at the desired
address.
4. At this point, the master does not acknowledge the transmission, but generates a stop condition instead.
5. In response, the TMC 24A01/24A02/24A04/24A08/24A16 stops transmitting data and reverts to its stand-by
mode (see Figure 3-13).
Start Slave Address
Word Address
Start Slave Address
Data (n)
Stop
A
C
K
A
C
K
A
C
K
N
O
A
C
K
Figure 3-13. Random Address Byte Read Operation
12
SEQUENTIAL READ OPERATION
Sequential read operations can be performed in two ways: as a series of current address reads or as random
address reads. The first data is sent in the same way as the previous read mode used on the bus. The next time,
however, the master responds with an ACK, indicating that it requires additional data.
The TMC 24A01/24A02/24A04/24A08/24A16 continues to output data for each ACK it receives. To stop the
sequential read operation, the master does not respond with an ACK, but instead issues a Stop condition.
Using this method, data is output sequentially with the data from address “n” followed by the data from “n+1”. The
word address pointer for read operations increments all word addresses, allowing the entire EEPROM to be read
sequentially in a single operation. After the entire EEPROM is read, the word address pointer “rolls over” and the
TMC 24A01/24A02/24A04/24A08/24A16 continues to transmit data for each ACK it receives from the master
(see Figure 3-14).
Start Slave Address
Data (n)
Data (n + x)
A
C
K
A
C
K
A
C
K
N
O
A
C
K
Figure 3-14. Sequential Read Operation
13
ELECTRICAL DATA
Table 3-3. Absolute Maximum Ratings
°
(TA = 25 C)
Parameter
Symbol
Conditions
Rating
Unit
VCC
VIN
–
– 0.3 to + 7.0
V
Supply voltage
–
–
– 0.3 to + 7.0
– 0.3 to + 7.0
– 40 to + 85
– 65 to + 150
5000
V
V
Input voltage
VO
Output voltage
°
C
TA
–
Operating temperature
Storage temperature
Electrostatic discharge
°
C
TSTG
VESD
–
HBM
MM
V
500
Table 3-4. D.C. Electrical Characteristics
°
°
°
°
(TA = – 25 C to + 70 C (C), – 40 C to + 85 C (I), VCC = 1.8 V to 5.5 V)
Parameter
Input low voltage
Symbol
Conditions
Min
–
Typ
Max
Unit
VIL
0.3 VCC
–
–
–
–
–
–
–
–
V
SCL, SDA, A0, A1, A2
VIH
ILI
0.7 VCC
–
10
10
0.2
0.4
3
V
µA
µA
V
Input high voltage
Input leakage current
–
–
–
–
–
–
VIN = 0 to VCC
ILO
VOL
VO = 0 to VCC
Output leakage current
Output low voltage
IOL = 0.15 mA, VCC = 1.8 V
IOL = 2.1 mA, VCC = 2.5 V
VCC = 5.5 V, 400 kHz
VCC = 1.8 V, 100 kHz
VCC = 5.5 V, 400 kHz
VCC = 1.8 V, 100 kHz
mA
ICC1
ICC2
ICC3
ICC4
ICC5
Supply current
Write
Read
1
–
–
–
–
–
–
0.2
60
5
µA
µA
VCC = SDA = SCL = 5.5 V,
all other inputs = 0 V
Stand-by current
ICC6
–
–
1
VCC = SDA = SCL = 1.8 V,
all other inputs = 0 V
14
Table 3-4. D.C. Electrical Characteristics (Continued)
°
°
°
°
(TA = – 25 C to + 70 C (C), – 40 C to + 85 C (I), VCC = 1.8 V to 5.5 V)
Parameter
Symbol
Conditions
Min
Typ
Max
Unit
CIN
–
–
10
pF
°
Input capacitance
25 C, 1MHz,
VCC = 5 V, VIN = 0 V,
A0, A1, A2, SCL and WP pin
CI/O
–
–
10
°
Input/output capacitance
25 C, 1MHz,
VCC = 5 V, VI/O = 0 V,
SDA pin
Table 3-5. A.C. Electrical Characteristics
°
°
°
°
(TA = – 25 C to + 70 C (C), – 40 C to + 85 C (I), VCC = 1.8 V to 5.5 V)
Parameter
Symbol Conditions
VCC = 1.8 to 5.5 V
(Standard Mode)
VCC = 2.5 to 5.5 V
(Fast Mode)
Unit
Min
Max
Min
Max
FCLK
tHIGH
tLOW
External clock frequency
Clock high time
–
0
100
0
400
kHz
–
4
4.7
–
–
–
0.6
1.3
–
–
–
ms
Clock low time
–
tR
Rising time
SDA, SCL
1
0.3
0.3
–
tF
Falling time
SDA, SCL
–
0.3
–
–
tHD:STA
tSU:STA
tHD:DAT
tSU:DAT
tSU:STO
tBUF
Start condition hold time
Start condition setup time
Data input hold time
Data input setup time
Stop condition setup time
Bus free time
–
–
–
–
–
4
0.6
0.6
0
4.7
0
–
–
–
–
0.25
4
–
0.1
0.6
1.3
–
–
–
Before new
4.7
–
–
transmission
tAA
Data output valid from
clock low (note)
–
0.3
3.5
–
0.9
tSP
Noise spike width
Write cycle time
–
–
–
–
100
5
–
–
50
5
ns
tWR
ms
NOTES:
1. Upon customers request, up to 400 kHz (Max.) in standard mode and 1 MHz in fast mode are available.
2. When acting as a transmitter, the TMC 24A01/24A02/24A04/24A08/24A16 must provide an internal minimum delay
time to bridge the undefined period (minimum 300 ns) of the falling edge of SCL. This is required to avoid unintended
generation of a start or stop condition.
15
tF
tHIGH
tR
tLOW
SCL
SDA In
tSU:STA
tHD:STA
tHD:DAT
tSU:DAT
tSU:STO
tBUF
tAA
SDA Out
Figure 3-15. Timing Diagram for Bus Operations
SCL
SDA
8th Bit
ACK
WORDn
tWR
Stop
Condition
Start
Condition
Figure 3-16. Write Cycle Timing Diagram
16
Package Information
Plastic DIP Outline Dimensions
8-pin DIP (300mil) Outline Dimensions
A
8
5
B
1
4
H
C
D
I
a
G
E
ꢀ
Dimensions in mil
Nom.
Symbol
Min.
355
240
125
125
16
Max.
375
260
135
145
20
A
B
C
D
E
F
G
H
I
¾
¾
¾
¾
¾
50
70
¾
100
¾
¾
¾
295
335
0°
315
375
15°
¾
a
¾
Package Information
SOP Outline Dimensions
8-pin SOP (150mil) Outline Dimensions
8
1
5
A
B
4
C
C
'
G
H
D
a
E
ꢀ
Dimensions in mil
Nom.
Symbol
Min.
228
149
14
189
53
¾
Max.
244
157
20
A
B
C
C¢
D
E
F
¾
¾
¾
¾
¾
50
¾
¾
¾
¾
197
69
¾
4
10
G
H
a
22
4
28
12
0°
10°
Package Information
Carrier Tape Dimensions
P
0
P
1
t
D
E
ꢀ
W
B
0
C
D
1
P
K
0
A
0
SOP 8N
Symbol
Description
Dimensions in mm
12.0+0.3
-0.1
W
Carrier Tape Width
P
E
Cavity Pitch
8.0±0.1
1.75±0.1
5.5±0.1
1.55±0.1
1.5+0.25
4.0±0.1
2.0±0.1
6.4±0.1
5.20±0.1
2.1±0.1
0.3±0.05
9.3
Perforation Position
F
Cavity to Perforation (Width Direction)
Perforation Diameter
Cavity Hole Diameter
Perforation Pitch
D
D1
P0
P1
A0
B0
K0
t
Cavity to Perforation (Length Direction)
Cavity Length
Cavity Width
Cavity Depth
Carrier Tape Thickness
Cover Tape Width
C
Package Information
0-8
#8
#5
8-TSSOP
+ 0.10
0.125 - 0.05
#1
#4
3.10 MAX
0.10 MAX
0.65
+ 0.05
0.25 - 0.06
NOTES:
1. Dimensions are in millimeters.
8-TSSOP Package Dimensions