3107A0104000 [ETC]

22 AWG stranded (7x30) tinned copper conductors, Datalene insulation;
3107A0104000
型号: 3107A0104000
厂家: ETC    ETC
描述:

22 AWG stranded (7x30) tinned copper conductors, Datalene insulation

文件: 总3页 (文件大小:104K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Detailed Specifications & Technical Data  
ENGLISH MEASUREMENT VERSION  
3107A Multi-Conductor - EIA Industrial RS-485 PLTC/CM  
For more Information  
please call  
1-800-Belden1  
General Description:  
22 AWG stranded (7x30) tinned copper conductors, Datalene® insulation, twisted pairs, overall Beldfoil®  
shield (100% coverage) plus a tinned copper braid (65% coverage), drain wire, UV resistant PVC jacket.  
Physical Characteristics (Overall)  
Conductor  
AWG:  
# Pairs AWG Stranding Conductor Material Dia. (in.)  
2
22  
7x30  
TC - Tinned Copper .030  
Total Number of Conductors:  
4
Insulation  
Insulation Material:  
Insulation Trade Name Insulation Material  
Datalene®  
FHDPE - Foam High Density Polyethylene  
Outer Shield  
Outer Shield Material:  
Layer # Outer Shield Trade Name Type Outer Shield Material  
Coverage (%)  
Tape Aluminum Foil-Polyester Tape 100.000  
Braid TC - Tinned Copper 65.000  
1
2
Beldfoil®  
Outer Shield Drain Wire AWG:  
AWG Stranding Drain Wire Conductor Material  
22 7x30 TC - Tinned Copper  
Outer Jacket  
Outer Jacket Material:  
Outer Jacket Material Nom. Wall Thickness (in.)  
PVC - Polyvinyl Chloride 0.053  
Overall Cable  
Overall Cabling Color Code Chart:  
Number Color  
1
2
White/Blue Stripe & Blue/White Stripe  
White/Orange Stripe & Orange/White Stripe  
Overall Nominal Diameter:  
0.350 in.  
Mechanical Characteristics (Overall)  
Operating Temperature Range:  
Non-UL Temperature Rating:  
-20°C To +60°C  
60°C  
Bulk Cable Weight:  
73 lbs/1000 ft.  
80 lbs.  
Max. Recommended Pulling Tension:  
Min. Bend Radius/Minor Axis:  
3.500 in.  
Applicable Specifications and Agency Compliance (Overall)  
Applicable Standards & Environmental Programs  
NEC/(UL) Specification:  
PLTC  
Page 1 of 3  
01-24-2013  
Detailed Specifications & Technical Data  
ENGLISH MEASUREMENT VERSION  
3107A Multi-Conductor - EIA Industrial RS-485 PLTC/CM  
CEC/C(UL) Specification:  
CM  
EU Directive 2011/65/EU (ROHS II):  
EU CE Mark:  
Yes  
Yes  
EU Directive 2000/53/EC (ELV):  
EU Directive 2002/95/EC (RoHS):  
EU RoHS Compliance Date (mm/dd/yyyy):  
EU Directive 2002/96/EC (WEEE):  
EU Directive 2003/11/EC (BFR):  
CA Prop 65 (CJ for Wire & Cable):  
MII Order #39 (China RoHS):  
Yes  
Yes  
10/01/2005  
Yes  
Yes  
Yes  
Yes  
Flame Test  
UL Flame Test:  
UL1685 UL Loading  
FT1  
CSA Flame Test:  
Suitability  
Sunlight Resistance:  
Yes  
Oil Resistance:  
Yes - Oil Res II  
Plenum/Non-Plenum  
Plenum (Y/N):  
No  
Surface Printing (Overall)  
Electrical Characteristics (Overall)  
Nom. Characteristic Impedance:  
Impedance (Ohm)  
120  
Nom. Capacitance Conductor to Conductor:  
Capacitance (pF/ft)  
11.0  
Nom. Capacitance Cond. to Other Conductor & Shield:  
Capacitance (pF/ft)  
20.9  
Nominal Velocity of Propagation:  
VP (%)  
78  
Nom. Conductor DC Resistance:  
DCR @ 20°C (Ohm/1000 ft)  
14.7  
Nominal Outer Shield DC Resistance:  
DCR @ 20°C (Ohm/1000 ft)  
1.8  
Nom. Attenuation:  
Description Freq. (MHz) Start Freq. (MHz) Stop Freq. (MHz) Attenuation (dB/100 ft.)  
1
.5  
Max. Operating Voltage - UL:  
Voltage  
300 V RMS  
Max. Recommended Current:  
Current  
2.7 Amps per conductor @ 25°C  
Page 2 of 3  
01-24-2013  
Detailed Specifications & Technical Data  
ENGLISH MEASUREMENT VERSION  
3107A Multi-Conductor - EIA Industrial RS-485 PLTC/CM  
Other Electrical Characteristic 1:  
Input Impedance/Unfitted Impedance .5 - 10 MHZ, 120 +-12 Ohms  
Notes (Overall)  
Notes: Oil Resistance: Passes Oil Res II Per UL1277, Table 10.17. For CPE jacketed version order YR46792.  
Put Ups and Colors:  
Item #  
Putup  
Ship Weight  
62.000 LB  
Color  
Notes  
C
Item Desc  
3107A 0101000  
3107A 0104000  
3107A 0105000  
1,000 FT  
4,000 FT  
5,000 FT  
BLACK  
BLACK  
BLACK  
2 PR #22 FHDPE SH PVC  
2 PR #22 FHDPE SH PVC  
2 PR #22 FHDPE SH PVC  
256.000 LB  
330.000 LB  
C
C N  
Notes:  
C = CRATE REEL PUT-UP.  
N = FINAL PUT-UP LENGTH MAY VARY -0% TO +10% FROM LENGTH SHOWN.  
Test Reports  
a) UL  
i) UL Test Reports are available on-line through the UL Client Document Access web portal.  
ii) UL Inspection Reports are also available through the UL Client Document Access web portal.  
b) CSA  
i) CSA "Descriptive Report and Test Results" documents are available on the CSA Gateway Portal.  
ii) CSA Inspection Reports are maintained on the CSA issued 'flash drive' at each manufacturing location.  
* other test data may be available if requested at time of order.  
Revision Number: 1  
Revision Date: 08-17-2012  
© 2013 Belden, Inc  
All Rights Reserved.  
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications  
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not  
ensure product availability.  
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,  
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or  
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,  
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.  
All sales of Belden products are subject to Belden's standard terms and conditions of sale.  
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the  
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and  
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,  
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide  
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not  
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for  
determining the applicability of legislation and regulations based on their individual usage of the product.  
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.  
Page 3 of 3  
01-24-2013  

相关型号:

3107A0105000

RS485, 2 Pr #22 Str TC, PO Ins, OSTC Brd, PVC Jkt, CM
BELDEN

3108

OUTLINE, FXD ATTEN. SMA, DC-23.0 GHz
Narda-ATM

3108/21

STATIVSTAB VERZINKT H600MM
ETC

31081

NAC Expander/Power Supply
GAMEWELL-FCI

31085

NAC Expander/Power Supply
GAMEWELL-FCI

31087

SOLISTRAND, Budget and DIAMOND GRIP
MACOM

31088

SOLISTRAND, Budget and DIAMOND GRIP
MACOM

31089

SOLISTRAND, Budget and DIAMOND GRIP
MACOM

3108A

RS485, 3 Pr #22 Str TC, PO Ins, OSTC Brd, PVC Jkt, CM
BELDEN

3108A0101000

RS485, 3 Pr #22 Str TC, PO Ins, OSTC Brd, PVC Jkt, CM
BELDEN

3108A0102000

RS485, 3 Pr #22 Str TC, PO Ins, OSTC Brd, PVC Jkt, CM
BELDEN

3108A0105000

RS485, 3 Pr #22 Str TC, PO Ins, OSTC Brd, PVC Jkt, CM
BELDEN