12 Watt Dual Series DC/DC Converters
Description
Features
!
These 10 and 12 Watt Dual Output DC/DC converters are
designed for telecommunications, medical or industrial
equipment and instrumentation systems. The converters
feature very wide input voltage ranges.
Low Noise Output
!
LC Type Input Filter
!
Six-Sided Shielded Steel Case
The converter consists of a hi-speed chopper circuit using
state of the art MOSFET technology, isolation transformer,
and high regulation linear post regulator. This provides for
very low noise and ultra stable output voltages.
!
Very Wide Input Voltage Ranges
(9-36, 18-54, and 24-72)
!
High Efficiency Operation
!
Long Term Output Fault Survival
!
5 Year Warranty
Selection Chart
Input Range
Outputs
VDC
Outputs
mA
VDC
Model
MIN
9.00
MAX
36.00
36.00
54.00
72.00
72.00
24D12.500
24D15.400
28D5.1000
48D12.500
48D15.400
±12.0
±15.0
±5.0
±500
±400
±1000
±500
±400
9.00
18.00
24.00
24.00
±12.0
±15.0
12 Watt Dual Series Block Diagram
CROSS
COUPLED
FOLDBACK
CURRENT LIMIT
PWM FEEDBACK
+ OUTPUT
3
A
100µF
LOW TC
REFERENCE
+ INPUT
1
2
LC
INPUT
FILTER
PWM
CONTROL
4 CMN
- INPUT
100µF
CROSS
5 - OUTPUT
COUPLED
FOLDBACK
SHIELDED ISOLATION
TRANSFORMER
CURRENT LIMIT
SIX-SIDED SHIELDED STEEL CASE
Manufacturing Company, Inc. • Concord, California 94520 • Ph: 925/687-4411 or 800/542-3355 • Fax: 925/687-3333 • www.calex.com • Email: sales@calex.com
4/8/99
1
12 Watt Dual Series DC/DC Converters
Input Parameters*
Model
24D12.500
24D15.400
Units
MIN
MAX
9.00
36.00
Voltage Range
VDC
TYP
MAX
TYP
TYP
20
45
Reflected Ripple, 0-20MHz bw
mA P-P
mA
Input Current Full Load
No Load
710
40
700
40
Efficiency
TYP
TYP
70
%
Switching Frequency
100
kHz
Maximum Input Overvoltage, 100ms
No damage
MAX
TYP
40
VDC
ms
Turn-on Time, 1% Output Error
Recommended Fuse
Model
60
(2)
28D5.1000
48D12.500
48D15.400
Units
MIN
MAX
18.00
54.00
24.00
72.00
Voltage Range
VDC
TYP
MAX
TYP
TYP
20
50
600
40
15
30
Reflected Ripple, 0-20MHz bw
mA P-P
mA
Input Current Full Load
No Load
360
24
350
24
Efficiency
TYP
TYP
60
87
70
%
Switching Frequency
100
kHz
Maximum Input Overvoltage, 100ms
No damage
MAX
TYP
60
80
VDC
ms
Turn-on Time, 1% Output Error
Recommended Fuse
60
(2)
Output Parameters*
24D12.500
48D12.500
24D15.400
48D15.400
MODEL
28D5.1000
Units
VDC
mA
Output Voltage
Rated Current (3)
±5
±12
±15
MIN
MAX
0
0
±500
0
±400
+1100/-900
MIN
TYP
MAX
4.95
5.00
5.05
11.90
12.00
12.10
14.90
15.00
15.10
Voltage Range
100% Load
VDC
Output Balance
(Plus to Minus Output, Full Load)
TYP
MAX
TYP
MAX
TYP
MAX
0.6
1.0
0.02
0.07
0.02
0.07
%
%
%
0.05
0.10
0.02
0.07
Load Regulation 0-100% Load
Line Regulation
Vin = Min-Max VDC
A
Short Term Stability (4)
Long Term Stability
TYP
TYP
TYP
TYP
TYP
0.02
0.3
20
%
%/kHrs
µs
Transient Response (5)
Dynamic Response (6)
Input Ripple Rejection (7)
20
mV peak
dB
60
TYP
MAX
TYP
MAX
10
40
50
Noise, 0-20MHz bw
mV P-P
ppm/°C
100
300
50
150
Temperature Coefficient
150
Short Circuit Protection to
Common for all Outputs
Continuous, 8 Hours Minimum Current Limit
NOTES
(3) No minimum load required.
All parameters measured at Tc=25°C, nominal input voltage
and full rated load unless otherwise noted. Refer to the
CALEX Application Notes for the definition of terms,
measurement circuits and other information.
*
(4) Short term stability is specified after a 30 minute warm-up at full
load.
(5) Transient response is defined as the time for the output to settle
from a 100% step load change to a 1% error band (rise time of
step = 2µSec).
(2) Determine the correct fuse size by calculating the maximum DC
current drain at low line input, maximum load then adding 20 to
25 percent.
(6) Dynamic response is defined as the peak overshoot during a
transient as defined in note 5 above.
Manufacturing Company, Inc. • Concord, California 94520 • Ph: 925/687-4411 or 800/542-3355 • Fax: 925/687-3333 • www.calex.com • Email: sales@calex.com
4/8/99
2
12 Watt Dual Series DC/DC Converters
General Specifications *
All Models
Units
Isolation
Isolation Voltage
10µA Leakage
Input-Output
Input to Output
Capacitance
MIN
TYP
500
VDC
pF
120
Environmental
Case Operating Range
No Derating
MIN
MAX
MIN
MAX
MIN
MAX
-25
80
-40
85
-55
100
°C
°C
Case Functional Range (8)
Storage Range
°C
Thermal Impedance (9)
General
TYP
6
°C/Watt
Unit Weight
TYP
6.5
oz
Mounting Kits
MK215-022 & MK215-08BDV
BOTTOM VIEW
SIDE VIEW
(7) The input ripple rejection is specified for DC to 120Hz ripple with
a modulation amplitude of 1% of Vin.
Mechanical tolerances unless otherwise noted:
X.XX dimensions: ±0.020 inches
(8) Thefunctionaltemperaturerangeisintendedtogiveanadditional
data point for use in evaluating this power supply. At the low
functional temperature the power supply will function with no
side effects, however sustained operation at the high functional
temperature will reduce expected operational life. The data
sheet specifications are not guaranteed over the functional
temperature range.
X.XXX dimensions: ±0.005 inches
Pin
1
2
Function
+INPUT
-INPUT
(9) Thecasethermalimpedanceisspecifiedasthecasetemperature
rise over ambient per package watt dissipated.
3
4
+OUTPUT
CMN
Typical Performance (Tc=25°C, Full Rated Load).
5
-OUTPUT
24D15.400 EFFICIENCY Vs. LINE INPUT
48D15.400 EFFICIENCY Vs. LINE INPUT
72
75
70
65
60
A
100% FULL LOAD
70
100% FULL LOAD
68
50% FULL LOAD
66
50% FULL LOAD
64
10
15
20
25
30
35
40
20
30
40
50
60
70
80
LINE INPUT (VOLTS)
LINE INPUT (VOLTS)
Manufacturing Company, Inc. • Concord, California 94520 • Ph: 925/687-4411 or 800/542-3355 • Fax: 925/687-3333 • www.calex.com • Email: sales@calex.com
4/8/99
3
12 Watt Dual Series DC/DC Converters
Typical Performance (Tc=25°C, Full Rated Load).
48D15.400 EFFICIECNY Vs. LOAD
24D INPUT CURRENT Vs. LINE INPUT
2.50
2.00
1.50
1.00
0.50
0.00
80
70
60
50
40
30
100% RATED LOAD
LINE = 24VDC
LINE = 48VDC
LINE = 72VDC
50% RATED LOAD
0
5
10
15
20
25
30
35
40
0
-30
0
20
40
60
80
100
LOAD (%)
LINE INPUT (VOLTS)
OUTPUT VOLTAGE Vs CASE TEMPERATURE
48D INPUT CURRENT Vs. LINE INPUT
0.2
0.1
1.2
1.0
0.8
0.6
0.4
0.2
0.0
NEGATIVE OUTPUT
POSITIVE OUTPUT
100% RATED LOAD
50% RATED LOAD
0.0
-0.1
-20
-10
0
10
20
30
40
50
60
70
80
0
10
20
30
40
50
60
70
80
CASE TEMPERATURE (Deg C)
LINE INPUT (VOLTS)
OUTPUT VOLTAGE Vs. OUTPUT LOAD
OUTPUT IMPEDANCE Vs. FREQUENCY
120
100
80
60
40
20
0
1
.1
+ OUTPUT
- OUTPUT
.01
A
.001
20
40
60
80
100
120
140
160
180
200
10
100
1K
10K
100K
1M
FREQUENCY (Hz)
OUTPUT LOAD (%)