48T5.15UW [ETC]

Analog IC ; 模拟IC\n
48T5.15UW
型号: 48T5.15UW
厂家: ETC    ETC
描述:

Analog IC
模拟IC\n

模拟IC 输出元件
文件: 总5页 (文件大小:156K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
8.5 Watt UW Triple Series DC/DC Converters  
Description  
Features  
n
The 8.5 Watt Triple Output DC/DC converters are ideal for  
wide(4:1)inputrangeapplications.Theseunitsareparticularly  
well suited for solar powered RTUs and instruments.  
Wide 4:1 Input Voltage Range (9-36 or 18-72VDC)  
n
Triple Low Noise, Highly Regulated Outputs  
n
Efficiency 70% for All Line Conditions  
They are designed with a high accuracy feedback control  
circuit and coupled inductor magnetics. Each converter has  
both a logic shut down pin and thermal overload protection  
circuitry. All outputs and the power switch are overvoltage  
protected.  
n
No Derating to 80°C Case Temperature  
n
Six-Sided Shielded Low Thermal  
Gradient Copper Case  
n
These converters are encased in a six-sided, completely  
shielded copper case. The UW Triple Series is covered under  
the CALEX 5 Year Warranty.  
500 VDC Minimum Input to Output Isolation  
n
Overvoltage Protected Outputs  
n
Pulse by Pulse Digital Current Limiting  
n
Five Year Warranty  
Selection Chart  
Input Range  
Outputs  
VDC  
Outputs  
mA  
VDC  
Model  
MIN  
9.00  
MAX  
36.00  
36.00  
72.00  
72.00  
12T5.12UW  
12T5.15UW  
48T5.12UW  
48T5.15UW  
5, ±12  
5, ±15  
5, ±12  
5, ±15  
800, ±185  
800, ±150  
800, ±185  
800, ±150  
9.00  
18.00  
18.00  
8.5WattUWTripleSeriesBlockDiagram  
SHIELDED ISOLATION  
TRANSFORMER  
+5 OUTPUT  
6
1000 µF  
100 µF  
100 µF  
THERMAL  
SHUTDOWN  
+5 CMN  
7
3
A
+ OUTPUT  
4
5
± CMN  
- OUTPUT  
1
+INPUT  
LC  
PWM  
CONTROL  
INPUT  
FILTER  
2
8
-INPUT  
FEEDBACK  
AMPLIFIER  
197  
ON/OFF  
1.5 MEG || 0.1µF  
SIX-SIDED SHIELDED COPPER CASE  
axFACTS:  
2401 Stanwell Drive  
Concord, CA 94520-4841  
(510) 687-4411 • Fax (510) 687-3333  
http://www.calex.com  
1
8.5 Watt UW Triple Series DC/DC Converters  
Input Parameters*  
Model  
12T5.12UW  
12T5.15UW  
48T5.12UW  
48T5.15UW  
Units  
MIN  
MAX  
TYP  
MAX  
TYP  
TYP  
9.00  
36.00  
18.00  
72.00  
Voltage Range  
VDC  
30  
60  
Reflected Ripple, 0-20MHz bw  
mA P-P  
mA  
Input Current Full Load  
No Load  
908  
19  
908  
19  
230  
15  
230  
15  
Efficiency  
TYP  
TYP  
78  
55  
%
Switching Frequency  
kHz  
Maximum Input Overvoltage, 100ms  
No damage  
MAX  
TYP  
45  
85  
VDC  
ms  
Turn-on Time, 1% Output Error  
Recommended Fuse  
120  
(2)  
Output Parameters*  
12T5.12UW  
12T5.15UW  
48T5.12UW  
48T5.15UW  
12T5.12UW  
48T5.12UW  
12T5.15UW  
48T5.15UW  
Model  
Units  
Output Voltage  
5
±12  
±15  
VDC  
mA  
MIN  
MAX  
200  
800  
50  
185  
50  
150  
Rated Current (3)  
MIN  
TYP  
MAX  
4.90  
5.00  
5.10  
11.76  
12.00  
12.24  
14.55  
15.00  
15.45  
Voltage Range  
100% Load  
VDC  
TYP  
MAX  
TYP  
MAX  
2.0  
3.5  
0.5  
1.5  
2.0  
3.0  
0.5  
1.0  
2.0  
3.0  
0.5  
1.0  
Load Regulation Min-Max Load  
%
%
Line Regulation  
Vin = Min-Max VDC  
Short Term Stability (4)  
Long Term Stability  
TYP  
TYP  
TYP  
TYP  
TYP  
0.02  
0.2  
40  
%
%/kHrs  
µs  
Transient Response (5)  
Dynamic Response (6)  
Input Ripple Rejection (7)  
75  
70  
50  
mV peak  
dB  
35  
TYP  
MAX  
TYP  
MAX  
TYP-  
O
20  
50  
120  
200  
15.0  
Noise, 0-20MHz bw  
mV P-P  
Temperature Coefficient  
Overvoltage Clamp (8)  
ppm/°C  
VDC  
18.0  
6.8  
A
Short Circuit Protection to  
Common for all Outputs  
Continuous, 8 Hours Minimum Current Limit and Thermal Overload  
NOTES:  
(7) The input ripple rejection is specified for DC to 120Hz ripple with  
a modulation amplitude of 1% Vin.  
All parameters measured at Tc=25°C, nominal input voltage  
and full rated load unless otherwise noted. Refer to the  
CALEX Application Notes for the definition of terms,  
measurementcircuitsandotherinformation.  
*
(8) For module protection only, see also note 2.  
(9) The logic shutdown pin is Open Collector TTL, CMOS, and relay  
compatible. The input to this pin is referenced to input minus.  
(2) Determine the correct fuse size by calculating the maximum DC  
currentdrainatlowlineinput, maximumload andthenadding20  
to 25 percent.  
(10) Thefunctionaltemperaturerangeisintendedtogiveanadditional  
data point for use in evaluating this power supply. At the low  
functionaltemperaturethepowersupplywillfunctionwithnoside  
effects, however, sustained operation at the high functional  
temperaturewillreduceexpectedoperationallife. Thedatasheet  
specificationsarenotguaranteedoverthefunctionaltemperature  
range.  
(3) Themodulewillnotbedamagedifrunatlessthanminimumload.  
Regulation can degrade with less than minium load or substatial  
loadimbalance.  
197  
(4) Short term stability is specified after a 30 minute warm-up at full  
load, and with constant line, load and ambient conditions.  
(11) Thecasethermalimpedanceisspecifiedasthecasetemperature  
rise over ambient per package watt dissipated.  
(5) The transient response is specified as the time required to settle  
from 25 to 75% step load change (rise time of step = 2µ Sec.) to  
a 1% error band.  
(6) Dynamic response is the peak overshoot voltage during the  
transient response time defined in note 5 above.  
axFACTS:  
2401 Stanwell Drive  
Concord, CA 94520-4841  
(510) 687-4411 • Fax (510) 687-3333  
http://www.calex.com  
2
8.5 Watt UW Triple Series DC/DC Converters  
General Specifications *  
All Models  
Units  
Logic Shutdown (9)  
ON Logic Level  
or Leave Pin Open  
MIN  
2.4  
VDC  
OFF Logic Level  
Input Resistance  
MAX  
TYP  
1.2  
10  
VDC  
kohms  
Converter Idle Current,  
Shut Down Pin Low  
TYP  
6.0  
mA  
Isolation  
Isolation Voltage  
10µA Leakage  
Input-Output  
Input to Output  
Capacitance  
MIN  
TYP  
500  
190  
VDC  
pF  
Environmental  
Case Operating Range  
No Derating  
MIN  
MAX  
MIN  
-25  
80  
-40  
90  
°C  
°C  
Case Functional Range (10)  
MAX  
BOTTOM VIEW  
SIDE VIEW  
MIN  
MAX  
TYP  
-55  
100  
4.4  
Storage Range  
°C  
°C/Watt  
°C  
Mechanical tolerances unless otherwise noted:  
X.XX dimensions: ±0.020 inches  
Thermal Impedance (11)  
Thermal Shutdown  
Case Temperature  
TYP  
90  
X.XXX dimensions: ±0.005 inches  
General  
Seal around terminals is not hermetic. Do not immerse units in any  
liquid.  
Unit Weight  
Mounting Kit  
TYP  
7.0  
oz  
MS9  
Pin  
1
Function  
+INPUT  
2
-INPUT  
12T5.15UW EFFICIENCY Vs. LINE INPUT  
3
4
5
6
7
8
+12/ +15 OUTPUT  
±OUTPUT CMN [1]  
-12/-15 OUTPUT  
+5 OUTPUT  
+5 CMN [1]  
ON/OFF  
80  
75  
70  
65  
100% FULL LOAD  
50% FULL LOAD  
[1] Note: Pins 4 & 7 are connected internally.  
Typical Performance (Tc=25°C, Full Rated Load).  
5
10  
15  
20  
25  
30  
35  
40  
CURVES APPLICABLE TOABOTH ±12 AND ±15 VDC  
LINE INPUT (VOLTS)  
48T5.15UW EFFICIENCY Vs. LINE INPUT  
12T5.15UW EFFICIENCY Vs. LOAD  
85  
80  
75  
70  
65  
85  
LINE = 12VDC  
80  
100% FULL LOAD  
LINE = 9VDC  
75  
50% FULL LOAD  
70  
197  
LINE = 36VDC  
65  
60  
10  
20  
30  
40  
50  
60  
70  
80  
20  
40  
60  
80  
100  
LINE INPUT (VOLTS)  
LOAD (%)  
axFACTS:  
2401 Stanwell Drive  
Concord, CA 94520-4841  
(510) 687-4411 • Fax (510) 687-3333  
http://www.calex.com  
3
8.5 Watt UW Triple Series DC/DC Converters  
Typical Performance (Tc=25°C, Full Rated Load).  
CURVES APPLICABLE TO BOTH ±12 AND ±15 VDC  
+5 VOLT OUTPUT*  
48T5.15UW EFFICIENCY Vs. LOAD  
CROSS REGULATION Vs. PERCENT OF FULL LOAD  
85  
3.0  
2.5  
2.0  
1.5  
1.0  
0.5  
0.0  
-0.5  
-1.0  
-1.5  
LINE = 18VDC  
80  
LINE = 48VDC  
+\-15 FULL LOAD  
75  
70  
LINE = 72VDC  
65  
+\-15 MIN LOAD  
60  
55  
20  
40  
60  
80  
100  
20  
30  
30  
30  
40  
50  
60  
70  
80  
90  
100  
100  
100  
LOAD (%)  
5 VOLT LOAD (%)  
+15 VOLT OUTPUT*  
12T INPUT CURRENT Vs. LINE INPUT VOLTAGE  
CROSS REGULATION Vs. PERCENT OF FULL LOAD  
1.6  
1.4  
1.2  
1.0  
0.8  
0.6  
0.4  
0.2  
0.0  
1.0  
0.5  
+5 FULL LOAD  
-15 FULL LOAD  
0.0  
+5 FULL LOAD  
-15 MIN LOAD  
-0.5  
-1.0  
-1.5  
-2.0  
+5 MIN LOAD  
100% FULL LOAD  
50% FULL LOAD  
-15 FULL LOAD  
+5 MIN LOAD  
-15 MIN LOAD  
5
10  
15  
20  
25  
30  
35  
40  
40  
50  
60  
70  
80  
90  
LINE INPUT (VOLTS)  
+15 VOLT LOAD (%)  
-15 VOLT OUTPUT*  
48T INPUT CURRENT Vs. LINE INPUT VOLTAGE  
CROSS REGULATION Vs. PERCENT OF FULL LOAD  
0.8  
0.6  
0.4  
0.2  
0.0  
0.4  
0.2  
+5 FULL LOAD  
A
+15 FULL LOAD  
-0.0  
-0.2  
-0.4  
-0.6  
-0.8  
-1.0  
100% FULL LOAD  
50% FULL LOAD  
+5 MIN LOAD  
+15 FULL LOAD  
40  
50  
60  
70  
80  
90  
0
10  
20  
30  
40  
50  
60  
70  
80  
LINE INPUT (VOLTS)  
-15 VOLT LOAD (%)  
197  
axFACTS:  
2401 Stanwell Drive  
Concord, CA 94520-4841  
(510) 687-4411 • Fax (510) 687-3333  
http://www.calex.com  
4
8.5 Watt UW Triple Series DC/DC Converters  
Typical Performance (Tc=25°C, Full Rated Load).  
CURVES APPLICABLE TO BOTH ±12 AND ±15 VDC  
12T IDLE CURRENT Vs. LINE INPUT  
48T IDLE CURRENT Vs. LINE INPUT  
16  
11  
10  
9
14  
12  
10  
8
8
7
6
6
5
10  
15  
20  
25  
30  
35  
40  
10  
20  
30  
40  
50  
60  
70  
80  
LINE INPUT (VOLTS)  
LINE INPUT (VOLTS)  
OUTPUT VOLTAGE Vs. CASE TEMPERATURE  
0.4  
0.2  
+/-15 OUTPUT  
+5 OUTPUT  
0.0  
-0.2  
-0.4  
-0.6  
-30  
-20  
-10  
0
10  
20  
30  
40  
50  
60  
70  
80  
CASE TEMPERATURE (Deg C)  
A
197  
axFACTS:  
2401 Stanwell Drive  
Concord, CA 94520-4841  
(510) 687-4411 • Fax (510) 687-3333  
http://www.calex.com  
5

相关型号:

48T5.15XC

DC to DC Converter
ETC

48T55M25

FERNMELDELAMPE T5.5 SOCKEL 48V
ETC

48TQFP

48 PIN TQFP/TQN PACKAGE OUTLINE
SMSC

48V10

Analog IC
ETC

48V19

Analog IC
ETC

48V28

Analog IC
ETC

48VFL11

Temperature PID Controllers
EXTECH

48VFL11_15

Temperature PID Controllers
EXTECH

48VFL13

Temperature PID Controllers
EXTECH

48VFL13_15

Temperature PID Controllers
EXTECH

48VTR

1/16 DIN Process Controller
EXTECH

48X62X8

OELDICHTUNG EINZELLIPPE NITRILMANTEL 5ST
ETC