50H07CB [ETC]

Fuse ; 保险丝\n
50H07CB
型号: 50H07CB
厂家: ETC    ETC
描述:

Fuse
保险丝\n

文件: 总3页 (文件大小:59K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
®
Bu s s m a n n  
HRC FORM II Cu rre n t Lim it in g Fu s e s  
Ce ra m ic Bo d y  
HRC FORM II  
Dimensional Data  
F
J
E
D
G
A
B
H
C
H07CB (Offset Blades)  
F
J
E
A
G
D
B
H
C
K07CB/K07CRB/L14CB/M14CB (Offset Blades)  
CATALOG SYMBOL: H07CB, K07CB, KO7CRB, L14CB,  
M14CB, L09CB, M09CB, P09CB, P11CB AND R11CB  
CERAMIC BODY FUSE  
600 VOLTS A.C. OR LESS  
250 VOLTS D.C.  
C
A
B
H
G
D
CURRENT LIMITING  
200,000 AMPS RMS SYMMETRICAL  
CSA C22.2 NO. 106M1992  
E
F
BS88:2, IEC269:2  
L09CB/M09CB/P09CB (Center Blades)  
K
K
F
A
B
Applications  
G
D
• HRC FORM II fuses are often used to protect motor control  
circuits, together with contactors and overload protection  
relays.  
H
E
C
• Type 2 coordination - per IEC 947-4.  
P11CB/R11CB (Center Blades)  
Form No. HCR FORM II  
Page 1 of 3  
12-21-98  
BIF Doc #4131  
SB98107  
Rev. A  
®
Bu s s m a n n  
HRC FORM II Cu rre n t Lim it in g Fu s e s  
Ce ra m ic Bo d y  
HRC FORM II  
Ratings, Categories and Dimensions  
Current  
Ratings  
(Amps)  
Dimensions in Inches and (mm)  
Catalog  
Number  
CSA  
Category  
A
B
C
D
E
F
G
H
J
K
2
4
6
10  
15  
20  
25  
30  
2H07CB  
4H07CB  
6H07CB  
10H07CB  
15H07CB  
20H07CB  
25H07CB  
30H07CB  
1.38  
(35)  
.56  
(14)  
3.38  
(85)  
.38  
(9)  
.06  
(1.2)  
2.88  
(73)  
.22  
(5.6)  
.31  
(8)  
.56  
(14)  
HRCII-C  
40  
50  
60  
40K07CB  
50K07CB  
60K07CB  
2.19  
(56)  
.88  
(22)  
3.44  
(87)  
.5  
(13)  
.06  
(1.2)  
2.88  
(73)  
.22  
(5.6)  
.31  
(8)  
.88  
(22)  
HRCII-C  
80  
100  
80K07CRB  
100K07CRB  
2.19  
(56)  
.88  
(22)  
3.75  
(95)  
.5  
(13)  
.06  
(1.2)  
2.88  
(73)  
.22  
(5.6)  
.31  
(8)  
.88  
(22)  
HRCII-MISC  
HRCII-C  
80  
100  
80L14CB  
100L14CB  
2.38  
(60)  
.88  
(21.4)  
4.38  
(111)  
.56  
(14.3)  
.13  
(3.2)  
3.69  
(94)  
.34  
(8.7)  
.44  
(11)  
1
(25.4)  
125  
150  
200  
125M14CB  
150M14CB  
200M14CB  
2.56  
(65)  
1.5  
(38)  
4.38  
(111)  
.75  
(19)  
.09  
(2.4)  
3.69  
(94)  
.34  
(8.7)  
.44  
(11)  
HRCII-MISC  
HRCII-MISC  
HRCII-C  
80  
100  
80L09CB  
100L09CB  
2.38  
(60)  
.88  
(21.4)  
5
.56  
(14)  
.13  
(3.2)  
4.38  
(111)  
.34  
(8.7)  
.44  
(11)  
(127)  
125  
150  
200  
125M09CB  
150M09CB  
200M09CB  
2.56  
(65)  
1.5  
(38)  
5.38  
(136)  
.75  
(19)  
.13  
(3.2)  
4.38  
(111)  
.34  
(8.7)  
.56  
(14)  
250  
300  
350  
400  
250P09CB  
300P09CB  
350P09CB  
400P09CB  
3.06  
(178)  
2.31  
(59)  
5.38  
(1136)  
1
.19  
(4.8)  
4.38  
(111)  
.34  
(8.7)  
.5  
(13)  
HRCII-MISC  
(25.4)  
250  
300  
350  
400  
250P11CB  
300P11CB  
350P11CB  
400P11CB  
3.06  
(178)  
2.31  
(59)  
8.25  
(210)  
1
.19  
(5)  
5.25  
(133)  
.41  
(10)  
.63  
(16)  
1
25  
HRCII-C  
HRCII-C  
(25.4)  
450  
500  
600  
450R11CB  
500R11CB  
600R11CB  
3.19  
(81)  
2.88  
(73)  
8.25  
(210)  
1
.25  
(6.3)  
5.25  
(133)  
.41  
(10)  
.63  
(16)  
1
25  
(25.4)  
Form No. HCR FORM II  
Page 2 of 3  
12-21-98  
SB98107  
BIF Doc #4131  
Rev. A  
®
Bu s s m a n n  
HRC FORM II Cu rre n t Lim it in g Fu s e s  
Ce ra m ic Bo d y  
HRC FORM II  
Energy Let-Through Curves  
Time/Current-Curves  
AMPERE  
RATING  
1,000  
Total I2t at 600V  
Total I2t at 460V  
Pre-Arcing I2t  
1,000,000  
100,000  
10,000  
1,000  
100  
10  
1
.1  
100  
FUSE RATING (AMPERES)  
.01  
Peak Let-Through Curves  
CURRENT IN AMPERES  
100  
600  
400  
200  
100  
60  
10  
1
30  
.1  
.01  
PROSPECTIVE CURRENT (SYM. RMS KA)  
The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies of this BIF document are by definition uncontrolled. This bulletin is intended to  
clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any  
products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been select-  
ed, it should be tested by the user in all possible applications.  
Form No. HCR FORM II  
12-21-98  
SB98107  
Page 3 of 3  
BIF Doc #4131  
Rev. A  

相关型号:

50H2D102G

POLYPHENYLENE SULFIDE FILM CAPACITORS
RUBYCON

50H2D102GB7

POLYPHENYLENE SULFIDE FILM CAPACITORS
RUBYCON

50H2D102GTS

POLYPHENYLENE SULFIDE FILM CAPACITORS
RUBYCON

50H2D102GTV

POLYPHENYLENE SULFIDE FILM CAPACITORS
RUBYCON

50H2D102H

POLYPHENYLENE SULFIDE FILM CAPACITORS
RUBYCON

50H2D102HB7

POLYPHENYLENE SULFIDE FILM CAPACITORS
RUBYCON

50H2D102HTS

POLYPHENYLENE SULFIDE FILM CAPACITORS
RUBYCON

50H2D102HTV

POLYPHENYLENE SULFIDE FILM CAPACITORS
RUBYCON

50H2D102J

POLYPHENYLENE SULFIDE FILM CAPACITORS
RUBYCON

50H2D102JB7

POLYPHENYLENE SULFIDE FILM CAPACITORS
RUBYCON

50H2D102JTS

POLYPHENYLENE SULFIDE FILM CAPACITORS
RUBYCON

50H2D102JTV

POLYPHENYLENE SULFIDE FILM CAPACITORS
RUBYCON