5 Watt Single Output, 5V Input Series DC/DC Converters  
Description  
Features  
The CALEX 5 Watt DC/DC converters are ideal for use in high  
performance computer data acquisition systems and board  
level products. They are designed for systems that require a  
regulated and isolated 5, 12 or 15 Volt auxiliary power source.  
n
Low Profile Copper Case (0.375" High)  
n
Six-side Shielded Case  
n
Low Input/Output Noise Operation  
The converters have efficiencies typically greater than  
60%. A linear post regulator provides highly stable DC  
outputs while minimizing noise.  
n
Wide Input Voltage Range  
n
Highly Regulated/Low Drift Output  
n
Every unit is 100% tested prior to shipment and is  
guaranteed under the CALEX 5 Year Warranty.  
100% Burn-in, 100% Tested  
5 Watt Single Output, 5 Volt Input  
Selection Chart  
Input Range  
Output  
VDC  
Output  
mA  
VDC  
Model  
MIN  
4.75  
4.75  
4.75  
MAX  
5.5  
5S5.1000  
5S12.450  
5S15.350  
5
1000  
450  
12.5  
15  
12  
15  
350  
5 Watt Single Output, 5 Volt Input Series Block Diagram  
ISOLATION  
TRANSFORMER  
LOW  
VOLTAGE  
CURRENT  
LIMIT  
3 + OUTPUT  
A
+ INPUT  
1
2
LC  
INPUT  
FILTER  
C
1
D
1
- INPUT  
LOW TC  
REFERENCE  
5
CMN  
197  
Output  
5
C 1  
D 1  
47 µF  
22 µF  
22 µF  
6.8 V  
N/A  
12  
15  
N/A  
SIX-SIDED SHIELDED COPPER CASE  
axFACTS:  
2401 Stanwell Drive  
Concord, CA 94520-4841  
(510) 687-4411 • Fax (510) 687-3333  
http://www.calex.com  
1
5 Watt Single Output, 5V Input Series DC/DC Converters  
Input Parameters*  
Model  
5S5.1000  
5S12.450  
5S15.350  
Units  
MIN  
MAX  
TYP  
MAX  
TYP  
TYP  
4.75  
5.25  
50  
75  
1800  
225  
Voltage Range  
VDC  
Reflected Ripple, 0-20MHz bw  
mA P-P  
mA  
Input Current Full Load  
No Load  
1750  
220  
1700  
230  
Efficiency  
TYP  
TYP  
59  
60  
25  
62  
%
Switching Frequency  
kHz  
Maximum Input Overvoltage,  
100ms No Damage  
MAX  
TYP  
6.2  
VDC  
ms  
Turn-on Time, 1% Output Error  
Recommended Fuse  
1
(2)  
Output Parameters*  
Model  
5S5.1000  
5S12.450  
5S15.350  
Units  
Output Voltage  
5
12  
15  
VDC  
MIN  
MAX  
0
1000  
4.95  
5.00  
5.05  
0
450  
0
350  
14.90  
15.00  
15.10  
Rated Load (3)  
mA  
VDC  
%
MIN  
TYP  
MAX  
TYP  
MAX  
TYP  
MAX  
11.90  
12.00  
12.10  
0.05  
0.20  
0.05  
0.20  
Voltage Range  
100% Load  
Load Regulation 0-100% Load  
Line Regulation  
Vin = Min-Max VDC  
%
%
Short Term Stability (4)  
TYP  
0.10  
Long Term Stability  
TYP  
TYP  
TYP  
0.30  
70  
%/kHrs  
µs  
Transient Response (5)  
Dynamic Response (6)  
50  
70  
70  
170  
75  
mV peak  
TYP  
MAX  
TYP  
MAX  
10  
40  
50  
200  
-
Noise, 0-20MHz bw  
mV P-P  
Temperature Coefficient  
Overvoltage Clamp (7)  
ppm/°C  
VDC  
TYP  
6.8  
-
Short Circuit Protection to  
Common for all Outputs  
Short Term, 1 Minute Maximum (2)  
A
NOTES:  
All parameters measured at Tc=25°C, nominal input voltage  
and full rated load unless otherwise noted. Refer to the  
CALEX Application Notes for the definition of terms,  
measurementcircuitsandotherinformation.  
(6) Dynamic response is the peak overshoot voltage during the  
transient response time defined in note 5 above.  
*
(7) For module protection only, see also note 2.  
(8) Thefunctionaltemperaturerangeisintendedtogiveanadditional  
data point for use in evaluating this power supply. At the low  
functionaltemperaturethepowersupplywillfunctionwithnoside  
effects, however, sustained operation at the high functional  
temperaturewillreduceexpectedoperationallife. Thedatasheet  
specificationsarenotguaranteedoverthefunctionaltemperature  
range.  
(2) For long term short circuit protection of the converters, install a  
slowblowfuseintheinputcircuit.Chooseafusesizethatis125%  
of your applications actual input current and does not exceed  
115% of the full load input current.  
197  
(3) Nominimumloadrequired.  
(4) Short term stability is specified after a 30 minute warm-up at full  
load, and with constant line, load and ambient conditions.  
(9) Thecasethermalimpedanceisspecifiedasthecasetemperature  
rise over ambient per package watt dissipated.  
(5) After a 100% step change of the load, the output voltage will  
bewithin±1%ofthefinalvaluewithinthetransientresponsetime.  
axFACTS:  
2401 Stanwell Drive  
Concord, CA 94520-4841  
(510) 687-4411 • Fax (510) 687-3333  
http://www.calex.com  
2
5 Watt Single Output, 5V Input Series DC/DC Converters  
General Specifications*  
All Models  
Units  
Isolation  
Isolation Voltage  
10µA Leakage  
Input-Output  
Input to Output  
Capacitance  
MIN  
TYP  
500  
75  
VDC  
pF  
Environmental  
Case Operating Range  
No Derating  
MIN  
MAX  
MIN  
MAX  
MIN  
-25  
80  
-30  
85  
-55  
100  
°C  
°C  
Case Functional Range (9)  
Storage Range  
°C  
MAX  
Thermal Impedance (10)  
General  
TYP  
10  
°C/Watt  
BOTTOM VIEW  
SIDE VIEW  
Mechanical tolerances unless otherwise noted:  
X.XX dimensions: ±0.020 inches  
Unit Weight  
TYP  
1.7  
oz  
Mounting Kits  
MS6 & MS15  
X.XXX dimensions: ±0.005 inches  
Seal around terminals is not hermetic. Do not immerse units in any  
liquid.  
Typical Performance (Tc=25°C, Rated Load).  
Pin  
1
2
Function  
+INPUT  
-INPUT  
5S5.1000 EFFICIENCY Vs. LINE INPUT VOLTAGE  
65  
3
5
+OUTPUT  
CMN  
100% FULL LOAD  
60  
55  
50% FULL LOAD  
50  
45  
4.75  
4.85  
4.95  
5.05  
5.15  
5.25  
LINE INPUT (VOLTS)  
5S15.350 EFFICIENCY Vs. LINE INPUT  
5S5.1000 EFFICIENCY Vs. LOAD  
5S15.350 EFFICIENCY Vs. LOAD  
70  
65  
60  
55  
50  
65  
55  
45  
35  
25  
70  
60  
50  
40  
30  
20  
LINE = 4.75VDC  
LINE = 4.75VDC  
100% FULL LOAD  
LINE = 5.0VDC  
LINE = 5.0VDC  
A
LINE = 5.25VDC  
LINE = 5.25VDC  
50% FULL LOAD  
4.75  
4.85  
4.95  
5.05  
5.15  
5.25  
0
20  
40  
60  
80  
100  
0
20  
40  
60  
80  
100  
LINE INPUT (VOLTS)  
LOAD (%)  
LOAD (%)  
INPUT CURRENT Vs. LINE INPUT VOLTAGE  
OUTPUT VOLTAGE Vs. CASE TEMPERATURE  
OUTPUT IMPEDANCE Vs. FREQUENCY  
2.0  
1.6  
1.2  
0.8  
0.4  
0.0  
0.20  
0.10  
1
.1  
100% FULL LOAD  
15 VOLT  
197  
50% FULL LOAD  
0.00  
5 VOLT  
.01  
.001  
-0.10  
-0.20  
-30  
-20  
-10  
0
10  
20  
30  
40  
50  
60  
70  
80  
10  
100  
1K  
10K  
100K  
1M  
0.75  
1.25  
1.75  
2.25  
2.75  
3.25  
3.75  
4.25  
4.75  
5.25  
CASE TEMPERATURE (Deg C)  
FREQUENCY (Hz)  
LINE INPUT (VOLTS)  
axFACTS:  
2401 Stanwell Drive  
Concord, CA 94520-4841  
(510) 687-4411 • Fax (510) 687-3333  
http://www.calex.com  
3
5 Watt WF Single Output Series DC/DC Converters  
Description  
Features  
This single output converter is designed for wide input range,  
n
Ultra Wide Input Voltage Range  
low noise industrial and instrument applications. The ultra  
wide isput range is ideal for battery or unregulated input  
applications.  
n
n
n
n
Low Noise, Trimable, Highly Stable Output  
Efficiency > 74% For All Line Conditions  
No Derating to 80°C Case Temperature  
The converter features a 55kHz switching frequency that  
provides outstanding regulation and efficiency at full load.  
Six-sided Shielded, Low Thermal Gradient  
Copper Case  
The output is regulated with high loop gain pulse width  
modulation control which provides linear regulator type  
performance.  
n
n
Overvoltage Protected Output  
The output is resistor or trimpot trimable by ±10%, which  
allows th WF to be set for +5.2 VDC in ECL applications.  
Pulse By Pulse Digital Current Limit  
The WF is protected from output shorts to ground by a high  
speed digital, current limit circuit. The output is oervoltage  
protected.  
5 Watt Single WF  
Input Parameters*  
Selection Chart  
Model  
12S5.1000WF  
Units  
MIN  
TYP  
MAX  
7.0  
12.0  
32.0  
Input Range  
VDC  
Output  
VDC  
Output  
mA  
Voltage Range  
VDC  
Model  
MIN  
MAX  
Reflected Ripple,  
0-20MHz bw (2)  
Input Current Full Load  
No Load  
MAX  
1000  
mA P-P  
mA  
12S5.1000WF  
7.0  
32.0  
5.0  
1000  
TYP  
TYP  
550  
10  
Efficiency  
TYP  
TYP  
75  
55  
%
Switching Frequency  
kHz  
Maximum Input  
Overvoltage,  
100ms No Damage  
Turn-on Time, to  
1% Output Error  
MAX  
TYP  
40  
VDC  
ms  
75  
(3)  
Recommended Fuse  
5 Watt Single WF Series Block Diagram  
OVERCURRENT  
SENSE  
+ INPUT  
- INPUT  
2
1
3
+ OUTPUT  
A
68 µF  
68 µF  
4.7 µF  
CMN  
TRIM  
5
4
PWM  
CONTROL  
FEEDBACK AMPLIFIER  
197  
LOW TC BANDGAP  
CTP REFERENCE  
SIX-SIDED SHIELDED COPPER CASE  
axFACTS:  
2401 Stanwell Drive  
Concord, CA 94520-4841  
(510) 687-4411 • Fax (510) 687-3333  
http://www.calex.com  
4
5 Watt WF Single Output Series DC/DC Converters  
General Specifications*  
Output Parameters*  
All Models  
Units  
Model  
12S5.1000WF  
Units  
Output Trim Function  
Output Voltage  
5
VDC  
MIN  
MAX  
MIN  
TYP  
MAX  
0
1000  
4.950  
5.000  
5.050  
Input Resistance  
Trim Range  
Isolation  
TYP  
MIN  
100  
±10  
kohms  
%
Rated Crrent (4)  
mA  
Voltage Range  
100% Load  
VDC  
Isolation (10)  
None  
Load Regulation  
0-100% Full Load  
Line Regulation  
Vin = Min-Max VDC  
Short Term Stability (5)  
Long Term Stability  
TYP  
MAX  
TYP  
MAX  
TYP  
TYP  
TYP  
0.05  
0.20  
0.05  
0.20  
0.05  
0.20  
500  
%
%
Environmental  
Case Operating Range  
No Derating  
MIN  
MAX  
MIN  
MAX  
MIN  
MAX  
TYP  
-25  
80  
-40  
90  
-55  
105  
10  
°C  
°C  
%
%/kHrs  
µs  
mV  
peak  
Case Functional Range (11)  
Storage Range  
Transient Response (6)  
°C  
Dynamic Response (7)  
Input Ripple Rejection (8)  
Noise, 0-20MHz bw  
TYP  
TYP  
200  
23  
Thermal Impedance (12)  
General  
°C/Watt  
dB  
Unit Weight  
TYP  
1.5  
oz  
TYP  
MAX  
TYP  
MAX  
20  
40  
50  
150  
6.8  
mV P-P  
Mounting Kits  
MS6 & MS15  
Temperature Coefficient  
Overvoltage Clamp (9)  
ppm/°C  
VDC  
TYP  
Short Circuit Protection  
to Common  
Continuous, 8 Hours Minimum  
Current Limit  
NOTES:  
3
3
4
5
All parameters measured at Tc=25°C, nominal input voltage  
and full rated load unless otherwise noted. Refer to the  
CALEX Application Notes for the definition of terms,  
measurementcircuitsandotherinformation.  
TRIM  
DOWN  
*
10K  
TRIMPOT  
4
(2) PeaktoPeakinputreflectedrippleisequaltotheDCoutputcurrent  
when measured into a zero impedance source resistance. For  
reduced input ripple use the suggested input filter circuit.  
TRIM  
UP  
(3) For long term short circuit protection of the converters, install a  
slowblowfuseintheinputcircuit.Chooseafusesizethatis125%  
of your applications actual input current and does not exceed  
115% of the full load input current.  
5
Figure 1. CONNECTIONS FOR OUTPUT TRIM  
(4) No minimum load required.  
A
(5) Shorttermstabilityisspecifiedaftera30minutewarmupatfullload,  
constant line and recording the drift over a 24 hour period.  
(6) Aftera25%stepchangeoftheload,theoutputvoltagewillbewithin  
±1% of the final value within the transient response time.  
12S5.1000WF  
L1  
(7) Dynamic response is the peak overshoot during a transient as  
defined in note 4 above.  
2
1
+OUT 3  
+IN  
+
7 - 32  
VDC  
(8) The input ripple rejection is specified for DC to 120 Hz ripple with  
a modulation amplitude of 1% of Vin.  
C1 C2  
4
5
LOAD  
TRIM  
CMN  
(9) For module protection only, see also note 3.  
–
-IN  
(10) Case is tied to pin 1. Input and output commons are connected  
internally.  
(11) Thefunctionaltemperaturerangeisintendedtogive additionaldata  
forevaluatingthispowersupply.Atthelowfunctionaltemperature  
the power supply will function with no side effects, however,  
sustainedoperationatthehighfunctionaltemperaturewillreduce  
expected operational life. The data sheet specifications are not  
guaranteedoverthefunctionaltemperaturerange.  
Figure 2. INPUT FILTER CIRCUIT  
197  
ThiscircuitwillreducetheinputreflectedrippleoftheWFSeriesto30  
mA P-P(0-20 MHz bw). L1 is 10 turns wound on a MICROMETALS  
T30-26coreorany6-10µH,1ampinductor.C1andC2arePanasonic  
47µF, 35V, HF capacitors (ECE-A1VF470R) or equivalent.  
(12) The case thermal impedance is the case temperature rise over  
ambient per watt dissipated.  
NOTE: For lowest noise operation use single point grounding to pin 5  
for both input and output circuits.  
axFACTS:  
2401 Stanwell Drive  
Concord, CA 94520-4841  
(510) 687-4411 • Fax (510) 687-3333  
http://www.calex.com  
5
5 Watt WF Single Output Series DC/DC Converters  
Typical Performance (Tc=25°C, Rated Load).  
EFFICIENCY Vs. LINE INPUT  
80.0  
75.0  
70.0  
65.0  
100% RATED LOAD  
50% RATED LOAD  
5
10  
15  
20  
25  
30  
35  
LINE INPUT (VOLTS)  
BOTTOM VIEW  
SIDE VIEW  
Mechanical tolerances unless otherwise noted:  
X.XX dimensions: ±0.020 inches  
EFFICIENCY Vs. LOAD  
80.0  
75.0  
70.0  
65.0  
60.0  
55.0  
50.0  
LINE = 7VDC  
X.XXX dimensions: ±0.005 inches  
LINE =  
12VDC  
Seal around terminals is not hermetic. Do not immerse units in any  
liquid.  
LINE = 32VDC  
Pin  
1
2
Function  
+INPUT  
-INPUT  
0
20  
40  
60  
80  
100  
3
4
+OUTPUT  
TRIM  
LOAD (%)  
5
OUT CMN  
WF SERIES INPUT RIPPLE Vs. LINE INPUT  
OUTPUT VOLTAGE Vs. OUTPUT CURRENT  
INPUT CURRENT Vs. LINE INPUT VOLTAGE  
0.6  
0.5  
0.4  
0.3  
0.2  
0.1  
0.0  
120  
100  
80  
60  
40  
20  
0
1.00  
0.80  
0.60  
0.40  
0.20  
0.00  
100% RATED LOAD  
CURRENT LIMIT MODE ->  
100% FULL LOAD  
50% FULL LOAD  
50% RATED LOAD  
5
10  
15  
20  
25  
30  
35  
0
20  
40  
60  
80  
100  
120  
140  
160  
5
10  
15  
20  
25  
30  
35  
NORMALIZED LOAD (%)  
LINE INPUT (VOLTS)  
LINE INPUT (VOLTS)  
A
LINE TO OUTPUT TRANSFER FUNCTION  
OUTPUT VOLTAGE Vs. CASE TEMPERATURE  
OUTPUT IMPEDANCE Vs. FREQUENCY  
-10  
-20  
-30  
-40  
0.10  
0.00  
10  
1
-0.10  
-0.20  
-0.30  
-0.40  
.1  
.01  
-30  
-20  
-10  
0
10  
20  
30  
40  
50  
60  
70  
80  
1
100  
1K  
10K  
10  
100  
1K  
10K  
100K  
1M  
CASE TEMPERATURE (Deg C)  
FREQUENCY (Hz)  
FREQUENCY (Hz)  
197  
axFACTS:  
2401 Stanwell Drive  
Concord, CA 94520-4841  
(510) 687-4411 • Fax (510) 687-3333  
http://www.calex.com  
6

相关型号:

5S5.150SIP

Analog IC
ETC

5S5.2000LV

Analog IC
ETC

5S5.600

Analog IC
ETC

5S5.600UM

Analog IC
ETC

5S5N1PS

SINGLE OUTPUT
POWER-ONE

5S6.145SIP

Analog IC
ETC

5S7.140SIP

Analog IC
ETC

5S70/411

Interface IC
ETC

5S70/412

Interface IC
ETC

5S70/414

Interface IC
ETC

5S70/418

Interface IC
ETC

5S72/115V

Interface IC
ETC