96-050G-4CT

更新时间:2024-09-18 02:49:44
品牌:ETC
描述:Signal Conditioner

96-050G-4CT 概述

Signal Conditioner 信号调理\n

96-050G-4CT 数据手册

通过下载96-050G-4CT数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。

PDF下载
Model 96 UltraStable  
Hydraulic Controls  
Process Control  
316L SS Pressure Sensor  
High Performance  
0-100 mV Output  
Absolute and Gage  
Low Pressure  
Oceanography  
Refrigeration/Compressors  
Pressure Transmitters  
Level Systems  
DESCRIPTION  
The Model 96 is a small profile, media compatible,  
piezoresistive silicon pressure sensor packaged in a 316L  
stainless steel housing. The Model 96 is available with a  
standard ¼ NPT fitting. The sensing package utilizes silicone oil  
to transfer pressure from the 316L stainless steel diaphragm to  
the sensing element.  
The Model 96 is designed for high performance, low  
pressure applications. A ceramic substrate is attached to the  
package that contains laser-trimmed resistors for temperature  
compensation and offset correction. An additional laser-  
trimmed resistor is included which can be used to adjust an  
external differential amplifier and provide span  
interchangeability to within 1%.  
Sensors with O-ring fittings, and high pressure sensors are  
also available. Please contact factory for more information.  
FEATURES  
1/4 NPT Thread, 5/8" Hex  
DIMENSIONS  
–20°C to +85°C Compensated  
Temperature Range  
0ꢀ1% Pressure Non-linearity  
1ꢀ0% Interchangeable Span  
(provided by gain set resistor)  
Solid State Reliability  
Low Power  
STANDARD RANGES  
Range  
psig  
psia  
0 to 15  
0 to 30  
0 to 50  
0 to 100  
0 to 300  
0 to 500  
1-74  
ISO – Wide Temperature Range  
316L SS Pressure Sensor  
Model 96 UltraStable  
PERFORMANCE SPECIFICATIONS  
All parameters specified at 1.5mA and at 25°C, after 10 second warm up, unless otherwise indicated. Unless specifically indicated, only those parameters  
indicated as tested are verified on each part. Parameters are specified for the compensated version only.  
PARAMETERS  
MIN  
75  
TYP  
100  
0
MAX  
150  
1
UNITS  
mV  
NOTES  
Full Scale Output Span  
1
2
3
Zero Pressure Output (Offset)  
Pressure Non Linearity  
–1  
mV  
–0ꢀ10  
–0ꢀ05  
0ꢀ10  
+0ꢀ05  
% Span  
% Span  
% Span  
Pressure Hysteresis  
0ꢀ02  
0ꢀ02  
3500  
Repeatability  
Input Resistance  
2000  
4000  
–0ꢀ75  
–0ꢀ5  
4500  
25000  
+0ꢀ75  
+0ꢀ5  
Output Resistance  
Temperature Error - Span (–20°C to +85°C)  
Temperature Error - Offset (–20°C to +85°C)  
Thermal Hysteresis - Span  
Thermal Hysteresis - Offset  
Long Term Stability - Span  
Long Term Stability - Offset  
Supply Current  
% Span  
% Span  
% Span  
% Span  
% Span/year  
% Span/year  
mA  
4
4, 5  
4
0ꢀ05  
0ꢀ05  
0ꢀ1  
4
0ꢀ1  
0ꢀ5  
5
1ꢀ5  
2ꢀ0  
3X  
6
7
8
Output Load Resistance  
Insulation Resistance (50 VDC)  
Pressure Overload  
M  
50  
MΩ  
Rated  
Compensated Temperature Range  
Operating Temperature Range  
Storage Temperature Range  
Media - Pressure Port  
–20°C to +85°C  
–40°C to +125°C  
–50°C to +125°C  
9
9
9
Liquids and Gases compatible with 316L Stainless Steel  
Compatible with Silicon, Pyrex, Gold, Fluorosilicone Rubber and  
316L Stainless Steel  
Media - Reference Port  
Weight  
27 g  
10  
Notes  
1ꢀ For amplified output circuits see application note TN-003ꢀ  
2ꢀ Measured at vacuum for absolute (A), ambient for gage (G)ꢀ  
3ꢀ Best fit straight lineꢀ  
7ꢀ Load resistance to reduce measurement errors due to output loadingꢀ  
8ꢀ Between case and sensing elementꢀ  
9ꢀ Maximum temperature range for product with standard cable and  
connector is –20°C to +105°Cꢀ  
4ꢀ Over the temperature range –20°C to +85°C with respect to +25°Cꢀ  
10ꢀ Weight depends upon configuration (cable, connector, pressure fitting)ꢀ  
5ꢀ 15 psi range sensors have an offset temperature error of 0ꢀ75%  
(Max) from –20°C to +85°Cꢀ  
11ꢀ For gage units used at pressures below atmosphere, the span accuracy  
is not guaranteedꢀ  
6ꢀ Guarantees output/input ratiometricityꢀ  
ORDERING INFORMATION  
APPLICATION SCHEMATIC  
96 - 050 G - 4  
C T  
T = Vent Tube, Blank is standard = No tube  
Electrical (C = Ribbon Cable with Connector,  
Electrical (P = Solder Pads, R = Ribbon Cable,  
Electrical (L = Lead, Uncompensated)  
Pressure Port (4 = 1/4 NPT)  
Type (A = Absolute, G = Gage)  
Pressure Range (15 to 500 psi, 050 = 50 psi)  
Model  
For other pressure ranges, process fittings and electrical connections contact factoryꢀ  
CONNECTIONS  
PAD / CONDUCTOR NO  
FUNCTION  
1
2
3
4
5
6
+OUT  
-EX  
+EX  
-OUT  
GAIN  
GAIN  
February 2001  
Feel free to contact customer service with any questions at  
Toll free 1(800)745-8008; Phone (757)766-1500; Fax (757)766-4297  
ISO – Wide Temperature Range  
1-75  

96-050G-4CT 相关器件

型号 制造商 描述 价格 文档
96-050G-4L ETC Signal Conditioner 获取价格
96-050G-4LT ETC Signal Conditioner 获取价格
96-050G-4P ETC Signal Conditioner 获取价格
96-050G-4PT ETC Signal Conditioner 获取价格
96-050G-4R ETC Signal Conditioner 获取价格
96-050G-4RT ETC Signal Conditioner 获取价格
96-100A-4C ETC Signal Conditioner 获取价格
96-100A-4CT ETC Signal Conditioner 获取价格
96-100A-4L ETC Signal Conditioner 获取价格
96-100A-4LT ETC Signal Conditioner 获取价格

96-050G-4CT 相关文章

  • Bourns 密封通孔金属陶瓷微调电位计产品选型手册(英文版)
    2024-09-20
    5
  • Bourns 精密环境传感器产品选型手册(英文版)
    2024-09-20
    8
  • Bourns POWrTher 负温度系数(NTC)热敏电阻手册 (英文版)
    2024-09-20
    8
  • Bourns GMOV 混合过压保护组件产品选型手册(英文版)
    2024-09-20
    6