20 AWG stranded (19x32) .037 tinned copper conductor, foam polyethylene insulation;型号: | 9907E4X2500 |
厂家: | ETC |
描述: | 20 AWG stranded (19x32) .037 tinned copper conductor, foam polyethylene insulation |
文件: | 总4页 (文件大小:34K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
9907 Coax - Coaxial Cable - Thinnet 10Base2 Ethernet
For more information please
call
1-800-Belden1
See Put-ups and Colors
Description:
20 AWG stranded (19x32) .037" tinned copper conductor, foam polyethylene insulation, Duobond® II (100% coverage) plus an overall
tinned copper braid shield (93% coverage), PVC jacket.
SUITABLE APPLICATIONS:
Suitable Applications
Thin Ethernet
PHYSICAL CHARACTERISTICS:
CONDUCTOR:
Number of Coax
Total Number of Conductors
RG Type
1
1
58A/U
AWG
20
Stranding
19x32
Conductor Diameter
Conductor Material
.037 in.
TC - Tinned Copper
INSULATION:
Insulation Material
Insulation Diameter
FHDPE - Foam High Density Polyethylene
.102 in.
OUTER SHIELD:
Outer Shield Material Trade Name
Outer Shield Type
Duobond® II
Tape/Braid
Outer Shield Material :
Layer Number
Trade Name
Type
Material
% Coverage (%)
1
Bonded Duofoil®
Tape
Bonded Aluminum Foil-
Polyester Tape-Aluminum
Foil
100
2
Braid
TC - Tinned Copper
93
Outer Shield %Coverage
OUTER JACKET:
100 %
Outer Jacket Material
PVC - Polyvinyl Chloride
OVERALL NOMINAL DIAMETER:
Page 1 of 4
9907 Coax - Coaxial Cable - Thinnet 10Base2 Ethernet
Overall Nominal Diameter
.185 in.
MECHANICAL CHARACTERISTICS:
Operating Temperature Range
UL Temperature Rating
-40°C To +80°C
60°C (UL AWM Style 1354)
22.3 lbs/1000 ft.
45 lbs.
Bulk Cable Weight
Max. Recommended Pulling Tension
Min. Bend Radius (Install)
1.8 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE:
APPLICABLE STANDARDS:
NEC/(UL) Specification
CM, CL2
CEC/C(UL) Specification
AWM Specification
CM
UL Style 1354 (30 V 60°C)
IEEE802.3 10Base2
ISO8802.3 10Base2
Yes
IEEE Specification
IEC Specification
EU CE Mark (Y/N)
EU RoHS Compliant (Y/N)
EU RoHS Compliance Date (mm/dd/yyyy):
Customer Part Number Reference Specification
Yes
01/01/2004
DEC Part No. 17-01248-00
FLAME TEST:
UL Flame Test
UL1685 UL Loading
PLENUM/NON-PLENUM:
Plenum (Y/N)
N
Plenum Number
82907, 89907
ELECTRICAL CHARACTERISTICS:
Nom. Characteristic Impedance
Nom. Capacitance Conductor to Shield
Nominal Velocity of Propagation
Nominal Delay
50 +/- 2 Ohms
25.4 pF/ft
80 %
1.27 ns/ft
Nom. Conductor DC Resistance @ 20 Deg. C
Nominal Outer Shield DC Resistance @ 20°C
Maximum Loop Resistance
8.8 Ohms/1000 ft
5.8 Ohms/1000 ft
15.24 Ohms/1000 ft
Nom. Attenuation :
Page 2 of 4
9907 Coax - Coaxial Cable - Thinnet 10Base2 Ethernet
Description
Frequency (MHz)
Start Frequency (MHz) Stop Frequency (MHz)
Nom. Attenuation
(dB/100 ft.)
1
.43
10
1.3
50
2.91
4.2
100
200
400
700
900
1000
6.1
8.9
12.1
13.9
14.8
Max. Operating Voltage - UL
300 V RMS, 30 V RMS (UL AWM Style 1354)
NOTES:
Notes
Tape to bond at overlap area only. Tape is not designed to bond to dielectric core.
PUT-UPS AND COLORS:
Item
Description
Put-Up (ft.)
Ship Weight (lbs.)
Jacket Color
Notes
9907 E4X1000
RG-58 TYPE COAX 1000
RG-58 TYPE COAX 1640
RG-58 TYPE COAX 2500
RG-58 TYPE COAX 3280
RG-58 TYPE COAX 500
RG-58 TYPE COAX U1000
24
GRAY, LIGHT DEC
C
9907 E4X1640
9907 E4X2500
9907 E4X3280
9907 E4X500
9907 E4XU1000
41
GRAY, LIGHT DEC
GRAY, LIGHT DEC
GRAY, LIGHT DEC
GRAY, LIGHT DEC
GRAY, LIGHT DEC
C
C
C
62.5
82
12.5
24
C = CRATE REEL PUT-UP.
Revision Number: 1 Revision Date: 05-12-2006
Page 3 of 4
9907 Coax - Coaxial Cable - Thinnet 10Base2 Ethernet
© 2006 Belden Wire & Cable Company
All Rights Reserved.
Although Belden Electronics Division ("Belden") makes every reasonable effort to ensure their accuracy at the time of this publication,
information and specifications described herein are subject to error or omission and to change without notice, and the listing of such
information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described
herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden CDT Electronics Division believes this product to be in compliance with the following environmental regulations: California
Proposition 65 Consent Judgment For Wire & Cable Mfgs.(San Francisco Superior Court Nos. 312962 And 320342); EU RoHS
(Directive 2002/95/EC, 27-Jan-2003);Material manufactured prior to the compliance date may still be in stock at Belden facilities and in our
Distributor's inventory. EU ELV (Directive 2000/53/EC, 18-Sept-2000); EU WEEE (Directive 2002/96/EC, 27-Jan-2003); And EU BFR
(Directive 2003/11/EC, 6-Feb-2003). The information provided in this Product Disclosure, and the identification of materials listed as
reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information and belief at the date of its
publication. The information provided in the Product Disclosure is designed only as a general guide for the safe handling, storage, and any
other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality
specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of
legislation and regulations based on their individual usage of the product.
Belden CDT Electronics Division declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended
by directive 93/68/EEC.
Page 4 of 4