A-BBBBCDE [ETC]
AC-DC Power Supply; AC- DC电源供应器型号: | A-BBBBCDE |
厂家: | ETC |
描述: | AC-DC Power Supply |
文件: | 总5页 (文件大小:630K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
S
®
C
NRTL US
C
US
MicroPAC AC-DC Power Supply
High efficiency up to 92%
Small Size
Up to 4 isolated outputs
12 V output standard
48 V output standard
Aux isolated 5 V @ 500 mA
bias standby supply
Over temperature warning
Over temperature shutdown
Intelligent fan control
Field replaceable fan
High power density
> 25 W/In3
Up to 1,300 W
Individual output enable / disable
> Configuration dependent
Low power standby mode
> Green mode
Output parallel capability
Output series capability
Output current sharing
All output enables / disable
capability
TTL control signals
Universal input
> 47 to 400 Hz
Visual LED display panel
MicroPAC to MicroPAC
current sharing
> 85 to 264 Vac
DC input
Optional power shed capability
> 120 to 300 Vdc
Product Description
The MicroPAC is the first Westcor product to utilize Vicor’s VI Chip technology. The power supply uses
BCM modules to provide up to 4 isolated semi regulated output voltages of 12, 24, 36 and 48 Vdc and
up to 1300 W of continuous power in a very small highly efficient package. The isolated outputs may be placed
in parallel/series configurations and for applications requiring higher power levels MicroPAC
power supplies can be configured in arrays up to several KW.
This factory configurable rugged power supply supports a wide range of customer power requirements and is
especially suited for distributed power architectures. The design offers a small flexible cost effective solution for
applications requiring Power Factor Correction, high efficiency and power density even in environmentally
challenging conditions.
Part Numbering
U P a
-
b
b
b
b
c
d
e
Cooling
Interface Customer Option
Output Configuration
Fill in character from chart below for each output
Number of
outputs,
1 to 4
Non-Safety Related
F = Fan
L = -40°C Fan
S = Standard (TTL levels)
Signaling and Control
I = Digital Bus Signaling
and Control
b = Vout
Watts
300
b = Vout Watts
A
B
C
D
E
12
12
12
12
24
24
G
H
I
48
48
48
48
325
650
600
Contact factory for information
regarding digital signaling bus
900
975
1200
600
J
1300
K
M
Z
36
[a]
900
[a]
F
1200
[b]
[b]
RoHS Compliant
[a] M defines a slot with an air block filler, no BCM board
G = RoHS
N = Non-RoHS
[b] Z indicates the slot is populated with a BCM board that is
connected in series or parallel with the adjacent slot
Examples:
UP1-FZZZ-FSG Denotes a single output of 24 V 1200 W
with a standard fan, standard TTL signaling and control, RoHS compliant
UP4-AAAA-LSN Denotes 4 output unit, each output is 12 V 300 W.
The fan is a -40°C capable unit, standard TTL signaling, and the unit is non-RoHS
Westcor MicroPAC
Page 1 of 5
Rev 1.0
8/2012
vicorpower.com
800 927.9474
Specifications
Input
Input Voltage
85 – 264 Vac
DC Rating: 120 Vdc – 300 Vdc
(¼” x 1¼”) Cooper Bussmann,
ABC-15,
(5 x 20 mm) Littelfuse,
216 series,
rated 15 A
Littelfuse,
505 series,
rated 16 A
(¼” x 1¼”) Littelfuse,
505 series,
External Fuse
rated 16A/500 Vdc
rated 16 A /500 Vdc
Frequency
47 ~ 400 Hz
30 A Peak
Inrush Current
≥92% @ Full load @ 25°C
ambient 48 V output
≥91% @ Full load @ 25°C
ambient 12 V output
Efficiency
Power factor
Turn-on time
>0.95 typ. Meets EN61000-3-2
AC on 1.5 sec TYP
EN55022 Class B Information technology equipment — Radio
Conducted EMI
disturbances characteristics — Limits and methods of measurement
BS EN55022:1998; CISPR 22:1997, incorporating corrigendum
Harmonic distortion
Isolation
Meets IEC 61000-3-2
Meets IEC 60950
<3.5 mA @ 264 Vac @ 63 Hz
20 mS typical
Leakage current
Hold up time
Warranty
2 Years
Output
Number of outputs
Normal output voltages
Maximum output current
Auxiliary output
1 to 4
12 V, 24 V, 36 V and 48 V (contact factory for details)
100 A @ 12 V
[27 A @ 48 V]
5 V @ 0.5 A 50 mV p-p
12 V output (11.3 V ~ 12.5 V)
Voltage regulation
48 V output (45 V ~ 50 V)
48 V output (1.6 Vp-p)
Ripple and noise
(20 MHz bandwidth)
12 V output (197 mV ~ 400 mV p-p)
Current sharing accuracy
Short circuit protection
Over voltage protection
Thermal protection
Maximum load
5 to 10%
“Fold-Back” Technique
12 V output set point 12.5 V typical
48 V modules 50 V typical
All outputs disabled when internal temperature exceeds safe operating
12 V up to 1200 W
48 V up to 1300 W
5.0 V Aux up to 2.5 W
Maximum load
Maximum load
Maximum load capacitance
1000 µF per 12 V output
100 µF per 48 V output
Westcor MicroPAC
Page 2 of 5
Rev 1.0
vicorpower.com
800 927.9474
8/2012
Specifications (CONT.)
Environmental
Storage temperature
Operating temperature
Functional shock
-40°C ~ +85°C
-20°C ~ +55°C (Extended temperature range is available; -40°C to +55°C)
MIL-STD 810F Method 516.5 procedure 1,
terminal peak saw-tooth wave, 40G 11 mS
Mil-STD 810G for minimum integrity vibration
95% non condensing
Vibration
Humidity
Cooling
Fan cooled (field replaceable) temperature speed control
Electromagnetic Compatibility
EN61000-6-1n European General EMC Immunity
IEC 61000-4-11 [50 Hz]
Voltage Dips 30% for 0.5 prd, pc C Voltage Interrupts (pc C)
IEC 61000-4-4 [TRANSIENT]
EFT/Burst 1 kV AC leads 500 V DC leads.
5/50 nsec 5 kHz rep rate (pc B)
IEC 61000-4-5 [SURGE]
Power line Surge AC in 2 kV CM 1 kV DM DC in
500 V CM ꢀ DM 1.2/µSec (pc B)
EN 61000-4-6 [0.15 to 80 MHz]
RF Common Mode Input leads, AC ꢀ DC leads,
CDN 150 kHz to 80 MHz, 3 Vrms with 80% AM @1 kHz (pa A)
EN 61000-4-2 [ELECTROSTATIC]
EN 61000-4-3
Electrostatic Discharge 4 kV Contact 8 kV Discharge (pc B)
RF E-Field 80 MHz to 1 GHz 3 V/m with 80% AM @ 1 kHz (pc A)
Power Freq H-Field 3A/M @ 50 Hz (pa A)
EN 61000-4-8
Reliability
FIT
TBD
Service life
5 Years
Safety & Regulatory
UL
UL 60950-1:2007 CAN C22.2 No. 60950-1-07
CSA*60950 3rd Edition (CB Report to include all national deviations)
EN 60950-1/A1:2010
CSA
EN
IEC
60950-1-2005 2 Ed. +A1:2009
Westcor MicroPAC
Page 3 of 5
Rev 1.0
8/2012
vicorpower.com
800 927.9474
Mechanical Drawings
Figure 1:
Physical Dimensions
and Electrical Connections
0
. 5 0 0
0
1 . 3 2 9
5 . 8 0 0
4 . 0 0
3 . 5 4 2
3 . 6 8 8
3 . 3 5 6
3 . 5 0 2
. 6 4 4
. 5 0 2
. 2 8 7
0
. 3 1 2
0
5 . 8 0 0
1 . 3 2 9
0
Westcor MicroPAC
Page 4 of 5
Rev 1.0
8/2012
vicorpower.com
800 927.9474
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and accessory
components, fully configurable AC-DC and DC-DC power supplies, and complete custom power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by
Vicor for its use. Vicor makes no representations or warranties with respect to the accuracy or completeness of the
contents of this publication. Vicor reserves the right to make changes to any products, specifications, and product
descriptions at any time without notice. Information published by Vicor has been checked and is believed to be
accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other
quality controls are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where
mandated by government requirements, testing of all parameters of each product is not necessarily performed.
Specifications are subject to change without notice.
Vicor’s Standard Terms and Conditions
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, which are available on Vicor’s webpage or
upon request.
Product Warranty
In Vicor’s standard terms and conditions of sale, Vicor warrants that its products are free from non-conformity to
its Standard Specifications (the “Express Limited Warranty”). This warranty is extended only to the original Buyer
for the period expiring two (2) years after the date of shipment and is not transferable.
UNLESS OTHERWISE EXPRESSLY STATED IN A WRITTEN SALES AGREEMENT SIGNED BY A DULY
AUTHORIZED VICOR SIGNATORY, VICOR DISCLAIMS ALL REPRESENTATIONS, LIABILITIES, AND
WARRANTIES OF ANY KIND (WHETHER ARISING BY IMPLICATION OR BY OPERATION OF LAW) WITH
RESPECT TO THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR
REPRESENTATIONS AS TO MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE, INFRINGEMENT OF
ANY PATENT, COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY RIGHT, OR ANY OTHER MATTER.
This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance,
or storage. Vicor shall not be liable for collateral or consequential damage. Vicor disclaims any and all liability
arising out of the application or use of any product or circuit and assumes no liability for applications assistance
or buyer product design. Buyers are responsible for their products and applications using Vicor products and
components. Prior to using or distributing any products that include Vicor components, buyers should provide
adequate design, testing and operating safeguards.
Vicor will repair or replace defective products in accordance with its own best judgment. For service under this
warranty, the buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping
instructions. Products returned without prior authorization will be returned to the buyer. The buyer will pay all
charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the product was
defective within the terms of this warranty.
Life Support Policy
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT
DEVICES OR SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE
OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support devices or systems
are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose
failure to perform when properly used in accordance with instructions for use provided in the labeling can be
reasonably expected to result in a significant injury to the user. A critical component is any component in a life
support device or system whose failure to perform can be reasonably expected to cause the failure of the life
support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of
Vicor products and components in life support applications assumes all risks of such use and indemnifies Vicor
against all liability and damages.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent
applications) relating to the products described in this data sheet. No license, whether express, implied, or arising
by estoppel or otherwise, to any intellectual property rights is granted by this document. Interested parties
should contact Vicor's Intellectual Property Department.
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
Email
Customer Service: custserv@vicorpower.com
Technical Support: apps@vicorpower.com
Westcor MicroPAC
Page 5 of 5
Rev 1.0
8/2012
vicorpower.com
800 927.9474
相关型号: