S
®
C
NRTL US  
C
US  
MicroPAC AC-DC Power Supply  
High efficiency up to 92%  
Small Size  
Up to 4 isolated outputs  
12 V output standard  
48 V output standard  
Aux isolated 5 V @ 500 mA  
bias standby supply  
Over temperature warning  
Over temperature shutdown  
Intelligent fan control  
Field replaceable fan  
High power density  
> 25 W/In3  
Up to 1,300 W  
Individual output enable / disable  
> Configuration dependent  
Low power standby mode  
> Green mode  
Output parallel capability  
Output series capability  
Output current sharing  
All output enables / disable  
capability  
TTL control signals  
Universal input  
> 47 to 400 Hz  
Visual LED display panel  
MicroPAC to MicroPAC  
current sharing  
> 85 to 264 Vac  
DC input  
Optional power shed capability  
> 120 to 300 Vdc  
Product Description  
The MicroPAC is the first Westcor product to utilize Vicor’s VI Chip technology. The power supply uses  
BCM modules to provide up to 4 isolated semi regulated output voltages of 12, 24, 36 and 48 Vdc and  
up to 1300 W of continuous power in a very small highly efficient package. The isolated outputs may be placed  
in parallel/series configurations and for applications requiring higher power levels MicroPAC  
power supplies can be configured in arrays up to several KW.  
This factory configurable rugged power supply supports a wide range of customer power requirements and is  
especially suited for distributed power architectures. The design offers a small flexible cost effective solution for  
applications requiring Power Factor Correction, high efficiency and power density even in environmentally  
challenging conditions.  
Part Numbering  
U P a  
-
b
b
b
b
c
d
e
Cooling  
Interface Customer Option  
Output Configuration  
Fill in character from chart below for each output  
Number of  
outputs,  
1 to 4  
Non-Safety Related  
F = Fan  
L = -40°C Fan  
S = Standard (TTL levels)  
Signaling and Control  
I = Digital Bus Signaling  
and Control  
b = Vout  
Watts  
300  
b = Vout Watts  
A
B
C
D
E
12  
12  
12  
12  
24  
24  
G
H
I
48  
48  
48  
48  
325  
650  
600  
Contact factory for information  
regarding digital signaling bus  
900  
975  
1200  
600  
J
1300  
K
M
Z
36  
[a]  
900  
[a]  
F
1200  
[b]  
[b]  
RoHS Compliant  
[a] M defines a slot with an air block filler, no BCM board  
G = RoHS  
N = Non-RoHS  
[b] Z indicates the slot is populated with a BCM board that is  
connected in series or parallel with the adjacent slot  
Examples:  
UP1-FZZZ-FSG Denotes a single output of 24 V 1200 W  
with a standard fan, standard TTL signaling and control, RoHS compliant  
UP4-AAAA-LSN Denotes 4 output unit, each output is 12 V 300 W.  
The fan is a -40°C capable unit, standard TTL signaling, and the unit is non-RoHS  
Westcor MicroPAC  
Page 1 of 5  
Rev 1.0  
8/2012  
vicorpower.com  
800 927.9474  
Specifications  
Input  
Input Voltage  
85 – 264 Vac  
DC Rating: 120 Vdc – 300 Vdc  
(¼” x 1¼”) Cooper Bussmann,  
ABC-15,  
(5 x 20 mm) Littelfuse,  
216 series,  
rated 15 A  
Littelfuse,  
505 series,  
rated 16 A  
(¼” x 1¼”) Littelfuse,  
505 series,  
External Fuse  
rated 16A/500 Vdc  
rated 16 A /500 Vdc  
Frequency  
47 ~ 400 Hz  
30 A Peak  
Inrush Current  
92% @ Full load @ 25°C  
ambient 48 V output  
91% @ Full load @ 25°C  
ambient 12 V output  
Efficiency  
Power factor  
Turn-on time  
>0.95 typ. Meets EN61000-3-2  
AC on 1.5 sec TYP  
EN55022 Class B Information technology equipment — Radio  
Conducted EMI  
disturbances characteristics — Limits and methods of measurement  
BS EN55022:1998; CISPR 22:1997, incorporating corrigendum  
Harmonic distortion  
Isolation  
Meets IEC 61000-3-2  
Meets IEC 60950  
<3.5 mA @ 264 Vac @ 63 Hz  
20 mS typical  
Leakage current  
Hold up time  
Warranty  
2 Years  
Output  
Number of outputs  
Normal output voltages  
Maximum output current  
Auxiliary output  
1 to 4  
12 V, 24 V, 36 V and 48 V (contact factory for details)  
100 A @ 12 V  
[27 A @ 48 V]  
5 V @ 0.5 A 50 mV p-p  
12 V output (11.3 V ~ 12.5 V)  
Voltage regulation  
48 V output (45 V ~ 50 V)  
48 V output (1.6 Vp-p)  
Ripple and noise  
(20 MHz bandwidth)  
12 V output (197 mV ~ 400 mV p-p)  
Current sharing accuracy  
Short circuit protection  
Over voltage protection  
Thermal protection  
Maximum load  
5 to 10%  
“Fold-Back” Technique  
12 V output set point 12.5 V typical  
48 V modules 50 V typical  
All outputs disabled when internal temperature exceeds safe operating  
12 V up to 1200 W  
48 V up to 1300 W  
5.0 V Aux up to 2.5 W  
Maximum load  
Maximum load  
Maximum load capacitance  
1000 µF per 12 V output  
100 µF per 48 V output  
Westcor MicroPAC  
Page 2 of 5  
Rev 1.0  
vicorpower.com  
800 927.9474  
8/2012  
Specifications (CONT.)  
Environmental  
Storage temperature  
Operating temperature  
Functional shock  
-40°C ~ +85°C  
-20°C ~ +55°C (Extended temperature range is available; -40°C to +55°C)  
MIL-STD 810F Method 516.5 procedure 1,  
terminal peak saw-tooth wave, 40G 11 mS  
Mil-STD 810G for minimum integrity vibration  
95% non condensing  
Vibration  
Humidity  
Cooling  
Fan cooled (field replaceable) temperature speed control  
Electromagnetic Compatibility  
EN61000-6-1n European General EMC Immunity  
IEC 61000-4-11 [50 Hz]  
Voltage Dips 30% for 0.5 prd, pc C Voltage Interrupts (pc C)  
IEC 61000-4-4 [TRANSIENT]  
EFT/Burst 1 kV AC leads 500 V DC leads.  
5/50 nsec 5 kHz rep rate (pc B)  
IEC 61000-4-5 [SURGE]  
Power line Surge AC in 2 kV CM 1 kV DM DC in  
500 V CM ꢀ DM 1.2/µSec (pc B)  
EN 61000-4-6 [0.15 to 80 MHz]  
RF Common Mode Input leads, AC ꢀ DC leads,  
CDN 150 kHz to 80 MHz, 3 Vrms with 80% AM @1 kHz (pa A)  
EN 61000-4-2 [ELECTROSTATIC]  
EN 61000-4-3  
Electrostatic Discharge 4 kV Contact 8 kV Discharge (pc B)  
RF E-Field 80 MHz to 1 GHz 3 V/m with 80% AM @ 1 kHz (pc A)  
Power Freq H-Field 3A/M @ 50 Hz (pa A)  
EN 61000-4-8  
Reliability  
FIT  
TBD  
Service life  
5 Years  
Safety & Regulatory  
UL  
UL 60950-1:2007 CAN C22.2 No. 60950-1-07  
CSA*60950 3rd Edition (CB Report to include all national deviations)  
EN 60950-1/A1:2010  
CSA  
EN  
IEC  
60950-1-2005 2 Ed. +A1:2009  
Westcor MicroPAC  
Page 3 of 5  
Rev 1.0  
8/2012  
vicorpower.com  
800 927.9474  
Mechanical Drawings  
Figure 1:  
Physical Dimensions  
and Electrical Connections  
0
. 5 0 0  
0
1 . 3 2 9  
5 . 8 0 0  
4 . 0 0  
3 . 5 4 2  
3 . 6 8 8  
3 . 3 5 6  
3 . 5 0 2  
. 6 4 4  
. 5 0 2  
. 2 8 7  
0
. 3 1 2  
0
5 . 8 0 0  
1 . 3 2 9  
0
Westcor MicroPAC  
Page 4 of 5  
Rev 1.0  
8/2012  
vicorpower.com  
800 927.9474  
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and accessory  
components, fully configurable AC-DC and DC-DC power supplies, and complete custom power systems.  
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by  
Vicor for its use. Vicor makes no representations or warranties with respect to the accuracy or completeness of the  
contents of this publication. Vicor reserves the right to make changes to any products, specifications, and product  
descriptions at any time without notice. Information published by Vicor has been checked and is believed to be  
accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other  
quality controls are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where  
mandated by government requirements, testing of all parameters of each product is not necessarily performed.  
Specifications are subject to change without notice.  
Vicor’s Standard Terms and Conditions  
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, which are available on Vicor’s webpage or  
upon request.  
Product Warranty  
In Vicor’s standard terms and conditions of sale, Vicor warrants that its products are free from non-conformity to  
its Standard Specifications (the “Express Limited Warranty”). This warranty is extended only to the original Buyer  
for the period expiring two (2) years after the date of shipment and is not transferable.  
UNLESS OTHERWISE EXPRESSLY STATED IN A WRITTEN SALES AGREEMENT SIGNED BY A DULY  
AUTHORIZED VICOR SIGNATORY, VICOR DISCLAIMS ALL REPRESENTATIONS, LIABILITIES, AND  
WARRANTIES OF ANY KIND (WHETHER ARISING BY IMPLICATION OR BY OPERATION OF LAW) WITH  
RESPECT TO THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR  
REPRESENTATIONS AS TO MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE, INFRINGEMENT OF  
ANY PATENT, COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY RIGHT, OR ANY OTHER MATTER.  
This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance,  
or storage. Vicor shall not be liable for collateral or consequential damage. Vicor disclaims any and all liability  
arising out of the application or use of any product or circuit and assumes no liability for applications assistance  
or buyer product design. Buyers are responsible for their products and applications using Vicor products and  
components. Prior to using or distributing any products that include Vicor components, buyers should provide  
adequate design, testing and operating safeguards.  
Vicor will repair or replace defective products in accordance with its own best judgment. For service under this  
warranty, the buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping  
instructions. Products returned without prior authorization will be returned to the buyer. The buyer will pay all  
charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the product was  
defective within the terms of this warranty.  
Life Support Policy  
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT  
DEVICES OR SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE  
OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support devices or systems  
are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose  
failure to perform when properly used in accordance with instructions for use provided in the labeling can be  
reasonably expected to result in a significant injury to the user. A critical component is any component in a life  
support device or system whose failure to perform can be reasonably expected to cause the failure of the life  
support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of  
Vicor products and components in life support applications assumes all risks of such use and indemnifies Vicor  
against all liability and damages.  
Intellectual Property Notice  
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent  
applications) relating to the products described in this data sheet. No license, whether express, implied, or arising  
by estoppel or otherwise, to any intellectual property rights is granted by this document. Interested parties  
should contact Vicor's Intellectual Property Department.  
Vicor Corporation  
25 Frontage Road  
Andover, MA, USA 01810  
Tel: 800-735-6200  
Fax: 978-475-6715  
Email  
Customer Service: custserv@vicorpower.com  
Technical Support: apps@vicorpower.com  
Westcor MicroPAC  
Page 5 of 5  
Rev 1.0  
8/2012  
vicorpower.com  
800 927.9474  

相关型号:

A-CCS-020-Z-SM

Chip Carrier sockets, SMT
ASSMANN

A-CCS-020-Z-T

ASS 0981 CO
ASSMANN

A-CCS-028-Z-SM

Chip Carrier sockets, SMT
ASSMANN

A-CCS-028-Z-T

ASS 0981 CO
ASSMANN

A-CCS-032-Z-SM

ASS 0142 CO
ASSMANN

A-CCS-044-Z-SM

ASS 0142 CO
ASSMANN

A-CCS-044-Z-T

ASS 0981 CO
ASSMANN

A-CCS-052-Z-SM

Chip Carrier sockets, SMT
ASSMANN

A-CCS-052-Z-T

RoHS compliant
ASSMANN

A-CCS-068-Z-T

ASS 0981 CO
ASSMANN

A-CCS-084-Z-SM

Chip Carrier sockets, SMT
ASSMANN

A-CCS-084-Z-T

ASS 0981 CO
ASSMANN