A18-250 [ETC]

CRIMP TERM FEMALE 6.35-0.8MM Inhalt pro Packung: 100 Stk. ; CRIMP TERM FEMALE 6.35-0.8MM Inhalt亲Packung : 100 Stk阅读。\n
A18-250
型号: A18-250
厂家: ETC    ETC
描述:

CRIMP TERM FEMALE 6.35-0.8MM Inhalt pro Packung: 100 Stk.
CRIMP TERM FEMALE 6.35-0.8MM Inhalt亲Packung : 100 Stk阅读。\n

文件: 总28页 (文件大小:399K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Terminals  
Why Sta-Kon Terminals Are Better  
Like any other value added manu-  
facturing process, using the best  
material is only a start. Our Sta-  
Kon terminals are all manufac-  
tured with the customer in mind,  
not a price tag! The following  
product features are usually  
able on most 1-piece Sta-Kon ter-  
minals:  
Sta-Kon’s Long Barrel Design  
If lowering electrical resistance,  
preventing wire pullout, eliminat-  
ing a “missed” crimp and an insu-  
lator that stays on the barrel dur-  
ing installation are your goals,  
then, you must design a terminal  
with a long barrel. The fact is that  
most competitive barrel lengths  
range from 20%-50% shorter  
than the Sta-Kon. The results are  
usually a stream of electrical fail-  
ure, rework and added expense.  
This also provides the insulator  
with additional surface area, hold-  
ing tight to the barrel. Many com-  
petitive insulators come off during  
crimping due to a limited barrel  
length.  
absent in competitive products.  
Chamfered/Funneled  
Terminal Barrel Entry  
This feature makes wire insertion  
faster and easier. Chamfering  
eliminates wire strand “hang up”  
and departure upon insertion into  
the terminal’s barrel. The loss of  
even a couple of wire strands can  
have negative results on electrical  
efficiency and resistance to  
mechanical strain.  
Platings/Finish  
Electroplated-Tin is standard. All  
others require minimum order  
quantities and are generally not  
stocked. Alternative platings as  
follows: Gold, Silver, Tin-alloys,  
Deep Internal Serrations  
After the insertion of a wire into  
the terminal’s barrel, a deep ser-  
rated interior insures a large area  
of contact which lowers the resis-  
Finish  
Suffix  
Spec.  
tance of a connection. Upon the  
mechanical force of tool applied  
pressure, the wire strands cold  
flow into the serrated interior.  
This guarantees electrical resis-  
tance lower than the wire to  
which it is applied. This feature  
also prevents pullout from vibra-  
tion and mechanical strain. Deep  
internal serrations can be com-  
pared to the effective holding  
power of a well treaded tire on a  
wet highway.  
Gold Plate  
GP  
MIL-G-45204 Type II, Grade B, C, D, Class  
O
Nickel Plate  
Plain Finish  
Silver Plate  
Tin Plate  
NP  
PF  
SP  
TP  
QQ-N-290 Class 2, Grade G  
None  
MIL-T-16366 Type I or II, 400°F, 204°C  
MIL-T-10727 Type I  
To order add the indicated suffix to the regular catalog number.  
Nickel, etc.  
The following finishes are avail-  
75  
Telecom 1-800-685-9452  
Terminals  
Why Sta-Kon Terminals Are Better—continued  
er electrical flow, void free.  
Anti-Rotational Tongues  
Selective Annealing  
This is a unique feature to the  
Thomas & Betts ring tongue ter-  
minal. This design prevents termi-  
nal shorting by keeping the termi-  
nal secure in the terminal block.  
The installer can place a greater  
number of terminals, closer  
Because of the mechanical  
strength of copper, an installer  
can experience fatigue associated  
with repeated installations. For  
this reason Thomas & Betts puts  
our terminals through one more  
step called selective annealing.  
This process leaves the barrel  
soft enough to crimp and form  
around the wire. However, we  
“cold form” the tongue during the  
manufacturing process so it  
remains strong. This is done so  
the tongue can withstand repeated  
bends and bolt tightening strain  
common in most electrical instal-  
lations. Many competitors attempt  
to accomplish similar goals by  
removing valuable material or  
using a softer copper which has  
lower conductivity. This increases  
electrical resistance as well as  
the odds for shorting and down-  
time.  
together without worry.  
Brazed or Overlapped Seam  
A long barrel design is of little  
value unless it is one solid piece.  
That is why Thomas & Betts  
brazes the seam on our vinyl insu-  
lated Sta-Kon and overlaps the  
seam on nylon insulated terminals.  
Many competitive terminals have  
butted seams. This means  
increased chances for wirestrand  
loss, poor resistance, wire pullout  
and electrical failure. If the  
installer doesn’t position the tool  
exactly on the correct spot on the  
barrel, there’s likely going to be  
an improper termination. The  
butted seam can also fold due to  
tool-applied pressure piercing the  
terminals insulation from the  
inside out. With a brazed or over-  
lapped seam the installer can  
crimp anywhere along the barrel’s  
1
surface providing up to 2⁄  
2
times  
the tensile strength of a butted  
seam terminal, guaranteeing prop-  
76  
Telecom 1-800-685-9452  
Terminals  
Thomas & Betts developed the first tool-applied solderless terminals  
and connectors nearly 50 years ago in response to industry awareness  
of the need for better performance of electrical systems.  
Today, sophisticated electrical and electronic equipment requires an  
even higher degree of reliability.  
Here are key factors built into the Sta-Kon terminal and connector  
line that deliver this reliability:  
Broad product selection  
Job suited tooling  
Testing and approvals  
Field proven performance  
New product development  
Service and availability  
Sta-Kon® Technical Data  
Terminals & Splices  
Insulation Rating  
Nylon  
Vinyl  
TEFZEL*  
U.L. 94  
Flammability  
flat bottom box  
center reinforced spring  
detent for minimum  
insertion force  
Voltage  
Temperature  
V-2  
V-0  
V-0  
600V**  
600V**  
600V**  
105°C  
105°C  
150°C  
funneled  
wire entrance  
extra-length  
insulation  
sleeve  
**1000V fixture or sign  
Disconnects  
300V  
105°C  
brazed  
seam  
electro  
tin plate  
compound spring rails provide positive  
contact after repeated insertions &  
crimp produces  
complete  
identification  
Sta-Kon® Disconnects  
even compression  
forces on insulation  
and stranding  
Internal barrel serrations and long barrel provide for maximum  
tensile strength  
Complete line of installing tools, engineered to match tool with  
terminal  
Funnel entry insulators allow for easier inserting of wire into  
barrel  
selectively annealed  
long barrel  
Color-coded for easy installation  
color-coded TEFZEL*,  
Nylon, or Vinyl  
complete wire & stud  
size identification  
Sta-Kon® Ring, fork & locking fork  
anti-rotational  
tongue  
Complete line of installing tools engineered to match tool with  
terminal  
First to gain military approval for pressure connections … many  
styles available for military applications  
Sta-Kon products exceed test specification requirements of mil-  
itary, U.L. and CSA  
TEFZEL* & Nylon Terminals provided with extra metal sleeve to  
grip insulation  
vinyl brazed seam, or  
NYLON/TEFZEL*  
insulated grip sleeve  
strands enter as a  
homogeneous group and  
compact tightly under  
compression due to fully  
brazed seam  
serrated inner barrel  
for maximum contact &  
tensile strength  
hardened tongue  
Vinyl insulated and bare Sta-Kons feature brazed seam wire  
barrels which can be crimped at any place on the barrel circumference  
The Shure Stake® tools are matched to terminals  
ERG-2001  
The Shure Stake mechanism prevents the dies from releasing the termi-  
nal until the proper compression has been completed.  
With this method, an operator achieves a reliable crimp everytime.  
77  
Telecom 1-800-685-9452  
Terminals  
Performance Data  
The Proper Installation  
Procedure for the Quality  
Assured Connection  
CODE  
Typical test  
value  
30  
The proper installation of termi-  
nals, splices and connectors is  
very important to the efficient  
performance of an electrical sys-  
tem. The properly installed con-  
nector will allow good conductivi-  
ty through the termination. A  
poor termination results in a high  
resistance connection. A poor  
connector installation may cause  
damage or failure of an entire  
system. Certain basic require-  
ments must be met to make a good  
termination.  
of T&B  
28  
24  
20  
16  
12  
8
Terminals  
NEMA  
requirement  
1.  
Before the connector or  
4
terminal is installed on the con-  
ductor, follow these recom-  
mended practices:  
0
8
22  
16  
20 18  
24  
16  
32  
14  
40  
12  
48 AMPS  
10 AWG  
Strip the insulation care-  
fully so as to avoid nicking or  
cutting conductor strands  
Strip the insulation to the  
proper length so that the con-  
ductors can be inserted fully  
into the connector barrel; the  
wire/cable should be visible in  
the inspection hole of the lug;  
the proper strip length can be  
found on page 49D.  
Voltage Drop Test 500 Cycles  
Thomas & Betts terminals show consistently lower millivolt drops than those allowed by NEMA speci-  
fication.  
CODE  
120  
Typical test  
value of  
T&B Terminals  
100  
NEMA require-  
2.  
Thomas & Betts wire  
ment  
strippers will help eliminate  
these  
80  
prob-  
lems  
60  
40  
stripping  
length  
by  
stripped wire  
indentor  
prop-  
erly  
gaging  
and  
terminal  
mea-  
rest  
oraiesnsthtoonwgnue suring  
the depth and  
length requirements for the  
conductor. See page 44D for  
wire strippers.  
0
22  
20  
18  
16  
14  
12  
10  
Wire Size (AWG)  
Wire Pullout Tension Test  
Thomas & Betts terminals show consistently higher wire retention forces than those required by NEMA  
specification.  
78  
Telecom 1-800-685-9452  
Terminals  
The Sta-Kon® Terminal Numbering System  
Distributor Package 100/50  
Bulk “O.E.M.” Packaged 1000/500  
Common to Both Packages  
• Letter A denotes 22-18 AWG wire  
range  
• Letter B denotes 16-14 AWG wire  
range  
• Letter C denotes 12-10 AWG wire  
range  
• Letter R preceding the above let-  
ters indicates the terminal is insu-  
lated  
• No letter R… no insulation … no  
exception!  
Distributor Packaged  
Part numbers are very descriptive  
indicating insulation and type, stud  
size, tongue style and the largest  
maximum wire that can be put  
inside.  
• If the letter R precedes the number  
the part is nylon insulated—RA18-6  
• If the letter R follows the number  
the part is vinyl insulated—14RB-8  
Installation Procedure  
1.  
Twist the wires to  
eliminate fanning of strands.  
stripping  
length  
stripped wire  
2.  
3.  
Open tool handles fully.  
Insert terminal in prop-  
indentor  
er die nest and locate it as  
shown above. When crimping a  
butt splice, position in proper  
die nest with window facing  
indentor.  
terminal  
rest  
orient tongue  
as shown  
4.  
secure terminal. Do not  
deform terminal.  
5. Insert properly stripped  
wire into terminal.  
6. Complete crimp by clos-  
ing handles.  
Close handles slightly to  
79  
Telecom 1-800-685-9452  
Nylon Terminals  
®
®
Nylon Insulated Ring—Insulation Grip  
Wt./Lbs.  
Per  
Hole 1000  
Dimensions  
Cat.  
No.  
Pkg.  
Qty.  
Wire  
Range  
Max.  
Ins.  
Bolt  
A
B
C
M
RZ22-2**  
RZ22-4**  
RZ22-6**  
RZ22-8**  
100  
100  
100  
100  
26-22  
26-22  
26-22  
26-22  
26-22  
.083  
.083  
.083  
.083  
.083  
#2  
#4  
1
1
1
1
1
.57  
.65  
.65  
.75  
.75  
.14  
.21  
.21  
.25  
.25  
.13  
.20  
.20  
.23  
.23  
.49  
.54  
.54  
.62  
.62  
#6  
#8  
#10  
RZ22-10** 100  
RAX23*  
RAX43*  
RAX63*  
RAX83*  
1000  
1000  
1000  
1000  
26-24  
26-24  
26-24  
26-24  
26-24  
.125  
.125  
.125  
.125  
.125  
#2  
#4  
3
3
3
3
3
.66  
.74  
.84  
.84  
.84  
.14  
.20  
.25  
.25  
.25  
.14  
.19  
.22  
.22  
.24  
.59  
.64  
.72  
.72  
.72  
Self-insulated with high dieletric-strength nylon  
sleeves, these ring terminals are recommended  
for temperatures up to 105°C. An inner bronze  
insulation grip sleeve lengthens the flexing  
radius of the conductor and eliminates conduc-  
tor creep. The nylon jacket is color-coded:  
#6  
#8  
#10  
RAX103* 1000  
RA18-4  
RA323  
RA333  
RA18-6  
RA853  
RA18-8  
RA833  
RA863  
RA18-10  
RA873  
RA18-14  
RA713  
100  
1000  
1000  
100  
1000  
100  
1000  
1000  
100  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
.136  
.136  
.136  
.136  
.136  
.136  
.136  
.136  
.136  
.136  
.136  
.136  
.136  
.136  
.136  
.136  
.136  
.136  
#4  
#4  
#6  
#6  
#6  
#8  
#8  
#8  
#10  
2
2
2
2
2
3
3
3
2
2
3
3
3
3
3
3
3
3
.70  
.70  
.23  
.23  
.23  
.26  
.26  
.26  
.26  
.26  
.31  
.31  
.46  
.46  
.46  
.46  
.53  
.53  
.72  
.72  
.14  
.14  
.14  
.25  
.25  
.25  
.25  
.25  
.25  
.25  
.31  
.31  
.31  
.31  
.35  
.35  
.50  
.50  
.59  
.59  
.59  
.71  
.71  
.71  
.71  
.71  
.71  
.71  
.84  
.84  
.84  
.84  
.87  
.87  
.92  
.92  
Color Code  
yellow  
red  
Wire Range  
26-22  
.70  
.83  
.83  
22-16  
.83  
blue  
18-14  
.83  
.83  
yellow  
12-10  
.86  
1000  
100  
1000  
#10  
.86  
Most standard bulk catalog numbers can  
be put on Mylar Tape for reel fed applica-  
tions (i.e. 12050 tool and application dies).  
Please consult tech service.  
1
"
1.07  
1.07  
1.07  
1.07  
1.17  
1.17  
1.27  
1.27  
1
⁄"  
5
RA18-516 100  
⁄"  
5
RA723  
1000  
100  
⁄"  
3
RA18-38  
RA733  
3
1000  
100  
Please put the suffix M for Mylar Tape  
RA2573M.  
1
RA18-12  
RA753  
⁄"  
1
1000  
⁄"  
RB14-4  
RB1323  
RB14-6  
RB853  
100  
1000  
100  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
.162  
.162  
.162  
.162  
.162  
.162  
.162  
.162  
.162  
.162  
.162  
.162  
.162  
.162  
.162  
.162  
.162  
#4  
#4  
#6  
#6  
#6  
#8  
#8  
#10  
21⁄  
21⁄  
2
.72  
.72  
.26  
.26  
.31  
.31  
.26  
.31  
.31  
.31  
.31  
.47  
.47  
.47  
.47  
.53  
.53  
.72  
.72  
.14  
.14  
.25  
.25  
.14  
.25  
.25  
.25  
.25  
.31  
.31  
.31  
.31  
.35  
.35  
.50  
.50  
.59  
.59  
.71  
.71  
.59  
.71  
.71  
.71  
.71  
.81  
.81  
.84  
.84  
.87  
.87  
.90  
.90  
(Bulk number 1000 and 500 packages.)  
2
3
3
3
3
3
.89  
1000  
1000  
100  
.89  
RZ & RAX stock thickness: .02  
RA & RB stock thickness: .03  
RC stock thickness: .04  
RB1333  
RB14-8  
RB863  
.74  
.89  
1000  
100  
.89  
RB14-10  
RB873  
31⁄  
2
.89  
1000  
100  
#10  
31⁄  
31⁄  
31⁄  
31⁄  
31⁄  
31⁄  
2
.89  
1
RB14-14  
RB713  
"
2
1.08  
1.08  
1.08  
1.08  
1.17  
1.17  
1.25  
1.25  
1
1000  
"
2
5
RB14-516 100  
"
2
5
RB723  
1000  
100  
"
2
3
RB14-38  
RB733  
"
2
3
1000  
100  
"
31⁄  
2
1
1
RB14-12  
RB753  
"
4
4
1000  
⁄"  
RC10-6  
RC333  
50  
500  
50  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
.210  
.210  
.210  
.210  
.210  
.210  
.210  
.210  
.210  
.210  
.210  
.210  
.210  
.210  
#6  
#6  
3
3
5
5
5
5
6
6
6
6
6
6
6
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.12  
1.12  
1.21  
1.21  
1.27  
1.27  
1.37  
1.37  
.37  
.37  
.37  
.37  
.37  
.37  
.53  
.53  
.53  
.53  
.59  
.59  
.72  
.72  
.27  
.27  
.27  
.27  
.27  
.27  
.32  
.32  
.31  
.31  
.35  
.35  
.81  
.81  
.81  
.81  
.81  
.81  
.86  
.86  
.94  
.94  
.98  
.98  
RC10-8  
RC863  
#8  
500  
50  
#8  
RC10-10  
RC363  
#10  
500  
50  
#10  
1
RC10-14  
RC713  
"
1
500  
50  
⁄"  
5
RC10-516  
RC703  
⁄"  
5
500  
50  
⁄"  
3
RC10-38  
RC733  
3
500  
50  
1
RC10-12  
RC753  
"
"
.52 1.02  
.52 1.02  
1
500  
6
* Not Listed By U.L. CSA  
** CSA Listed only  
U.L. Listed E9809  
Installing tools: WT2000, WT112M, WT145C, WT1455, ERG-2001, ERG-2003,  
WT145A, WT2130A (RC,RBC)  
Installing tool: WT1452 (RZ series only)  
80  
Telecom 1-800-685-9452  
Nylon Terminals  
®
®
Nylon Insulated Ring—Expanded Insulation Grip  
Wt./Lbs.  
Bolt Per  
Hole 1000  
Dimensions  
Cat.  
No.  
Pkg.  
Qty.  
Wire  
Range  
Max.  
Ins.  
A
B
C
M
RB14-4X  
RB1324  
RB14-6X  
RB854  
100  
1000  
100  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
.190  
.190  
.190  
.190  
.190  
.190  
.190  
.190  
.190  
.190  
.190  
.190  
.190  
.190  
#4  
#4  
4
4
4
4
5
5
5
5
6
6
6
6
6
6
.80  
.80  
.26  
.26  
.31  
.31  
.31  
.31  
.31  
.31  
.47  
.47  
.47  
.47  
.53  
.53  
.14  
.14  
.25  
.25  
.25  
.25  
.25  
.25  
.31  
.31  
.31  
.31  
.42  
.42  
.67  
.67  
.79  
.79  
.79  
.79  
.79  
.79  
.92  
.92  
.92  
.92  
.95  
.95  
#6  
.95  
1000  
100  
#6  
.95  
RB14-8X  
RB864  
#8  
.95  
1000  
#8  
.95  
RB14-10X 100  
#10  
.95  
RB874  
RB14-14X 100  
RB714 1000  
RB14-516X 100  
RB724 1000  
1000  
#10  
.95  
1
"
1.16  
1.16  
1.16  
1.16  
1.25  
1.25  
1
⁄"  
Catalog numbers with the suffix X indicate an  
expanded insulation grip. This means a wider  
wire entry to accommodate heavy wall insula-  
tion. Ring terminals won’t fall free even if the  
mounting screw loosens.  
5
⁄"  
5
⁄"  
3
RB14-38X 100  
RB734  
⁄"  
3
1000  
⁄"  
RC10-6X  
RC334  
50  
500  
50  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
.250  
.250  
.250  
.250  
.250  
.250  
.250  
.250  
.250  
.250  
.250  
.250  
.250  
#6  
#6  
5
5
5
5
5
5
6
6
6
6
6
6
6
1.10  
1.10  
1.10  
1.10  
1.10  
1.10  
1.22  
1.22  
1.32  
1.32  
1.38  
1.38  
1.48  
.37  
.37  
.37  
.37  
.37  
.37  
.53  
.53  
.53  
.53  
.59  
.59  
.72  
.27  
.27  
.27  
.27  
.27  
.27  
.32  
.32  
.31 1.05  
.31 1.05  
.35 1.09  
.35 1.09  
.52 1.13  
.91  
.91  
.91  
.91  
.91  
.91  
.96  
.96  
RB stock thickness: .03  
RC stock thickness: .04  
RC10-8X  
RC864  
#8  
500  
50  
#8  
RC10-10X  
RC364  
#10  
500  
50  
500  
#10  
1
RC10-14X  
RC714  
"
1
⁄"  
5
RC10-516X 50  
"
5
RC704  
500  
50  
500  
50  
⁄"  
3
RC10-38X  
RC734  
3
⁄"  
1
RC10-12X  
⁄"  
U.L. Listed E9809  
Installing tools: WT2000, WT112M, WT145C, ERG-2001, ERG-2003, WT145A,  
WT2130A(RC)  
Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications  
(i.e. 12050 tool and application dies).  
Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.)  
81  
Telecom 1-800-685-9452  
Nylon Terminals  
®
®
Nylon Insulated Ring  
Wt./Lbs.  
Bolt Per  
Hole 1000  
Dimensions  
Cat.  
No.  
Pkg.  
Qty.  
Wire  
Range  
Max.  
Ins.  
A
B
C
M
RD8-10  
RD367  
RD8-14  
RD717  
RD8-516  
RD727  
RD8-38  
RD737  
RD8-12  
RD757*  
25  
200  
25  
9-8-7  
9-8-7  
9-8-7  
9-8-7  
9-8-7  
9-8-7  
9-8-7  
9-8-7  
9-8-7  
9-8-7  
.340  
.340  
.340  
.340  
.340  
.340  
.340  
.340  
.310  
.310  
#10  
12 1.48  
12 1.48  
12 1.54  
12 1.54  
12 1.63  
12 1.63  
12 1.63  
12 1.63  
12 1.79  
12 1.79  
.42  
.42  
.46  
.46  
.57  
.57  
.57  
.57  
.82  
.82  
.28 1.29  
.28 1.29  
.36 1.32  
.36 1.32  
.36 1.35  
.36 1.35  
.36 1.35  
.36 1.35  
.55 1.39  
.55 1.39  
#10  
1
"
1
200  
25  
⁄"  
5
⁄"  
5
200  
25  
⁄"  
3
3
200  
25  
⁄"  
1
⁄"  
C
1
200  
⁄"  
RD10161  
RD10361  
RD10711  
RD10721  
RD10731  
200  
200  
200  
200  
200  
9-8-7AN  
9-8-7AN  
9-8-7AN  
9-8-7AN  
9-8-7AN  
.270  
.270  
.270  
.270  
.270  
#8  
12 1.40  
12 1.40  
12 1.45  
12 1.53  
12 1.53  
.41  
.41  
.45  
.56  
.56  
.24 1.20  
.24 1.20  
.27 1.22  
.34 1.25  
.34 1.25  
#10  
1
"
5
⁄"  
3
⁄"  
RD, RE, RF stock thickness: .04  
RG stock thickness: .05  
RE6-10  
RE267  
RE6-14  
RE717  
RE6-516  
RE727  
RE6-38  
RE737  
RE6-12  
RE757*  
20  
200  
20  
6-5  
6-5  
6-5  
6-5  
6-5  
6-5  
6-5  
6-5  
6-5  
6-5  
.420  
.420  
.420  
.420  
.420  
.420  
.420  
.420  
.395  
.395  
#10  
16 1.65  
16 1.65  
16 1.65  
16 1.65  
16 1.76  
16 1.76  
16 1.76  
16 1.76  
16 1.83  
16 1.83  
.49  
.49  
.49  
.49  
.61  
.61  
.61  
.61  
.82  
.82  
.28 1.40  
.28 1.40  
.28 1.40  
.28 1.40  
.34 1.47  
.34 1.47  
.34 1.47  
.34 1.47  
.55 1.43  
.55 1.43  
#10  
1
"
1
200  
20  
⁄"  
5
⁄"  
5
200  
20  
⁄"  
3
3
200  
20  
⁄"  
1
⁄"  
1
200  
⁄"  
RE10261  
RE10711  
RE10721  
RE10731  
200  
200  
200  
200  
6-5AN  
6-5AN  
6-5AN  
6-5AN  
.315  
.315  
.315  
.315  
#10  
16 1.55  
16 1.55  
16 1.70  
16 1.70  
.49  
.49  
.60  
.60  
.24 1.31  
.27 1.31  
.34 1.40  
.34 1.40  
1
⁄"  
5
⁄"  
3
⁄"  
RF4-10  
RF267  
RF4-14  
RF717  
RF4-516  
RF727  
RF4-38  
RF737  
RF757*  
15  
200  
15  
4-3  
4-3  
4-3  
4-3  
4-3  
4-3  
4-3  
4-3  
4-3  
.510  
.510  
.510  
.510  
.510  
.510  
.510  
.510  
.500  
#10  
21 1.76  
21 1.76  
21 1.76  
21 1.76  
21 1.84  
21 1.84  
23 1.84  
23 1.84  
23 1.90  
.56  
.56  
.56  
.56  
.62  
.62  
.62  
.62  
.82  
.36 1.49  
.36 1.49  
.36 1.49  
.36 1.49  
.35 1.53  
.35 1.53  
.35 1.53  
.35 1.53  
.55 1.49  
#10  
1
"
1
200  
15  
⁄"  
5
⁄"  
5
200  
15  
200  
200  
⁄"  
3
⁄"  
3
⁄"  
1
⁄"  
RF10261  
RF10711  
RF10721  
RF10731  
200  
200  
200  
200  
4-3AN  
4-3AN  
4-3AN  
4-3AN  
.380  
.380  
.380  
.380  
#10  
26 1.78  
26 1.78  
26 1.80  
26 1.80  
.55  
.55  
.62  
.82  
.30 1.51  
.30 1.51  
.34 1.49  
.34 1.49  
1
⁄"  
5
⁄"  
3
⁄"  
RG2-10  
RG267  
RG2-14  
RG717  
RG2-516  
RG727  
RG2-38  
RG737  
RG2-12  
RG757  
10  
100  
10  
2-1  
2-1  
2-1  
2-1  
2-1  
2-1  
2-1  
2-1  
2-1  
2-1  
.588  
.588  
.588  
.588  
.588  
.588  
.588  
.588  
.588  
.588  
#10  
42 2.15  
42 2.15  
42 2.15  
42 2.15  
42 2.15  
42 2.15  
42 2.15  
42 2.15  
42 2.35  
42 2.35  
.69  
.69  
.69  
.69  
.69  
.69  
.69  
.69  
.80  
.80  
.40 1.83  
.40 1.83  
.40 1.83  
.40 1.83  
.40 1.83  
.40 1.83  
.40 1.83  
.40 1.83  
.49 1.93  
.49 1.93  
#10  
1
"
1
100  
10  
⁄"  
5
⁄"  
5
100  
10  
⁄"  
3
3
100  
10  
⁄"  
1
⁄"  
1
100  
⁄"  
1
3
1
RG9711  
RG9731  
RG9751  
100  
100  
100  
2AN  
2AN  
2AN  
453  
.453  
.453  
⁄"  
48 2.07  
48 2.07  
48 2.26  
.69  
.69  
.80  
.40 1.74  
.40 1.74  
.49 1.84  
* Brazed Seam, Lolly-Pop Style Tongue  
ANAircraft Wire  
U.L. Listed E9809  
Installing tools: TBM6/TBM6S, WT2130A (RD Series only)  
Note: Not available on Mylar Tape.  
82  
Telecom 1-800-685-9452  
Nylon Terminals  
®
®
Nylon Insulated Ring—continued  
Wt./Lbs.  
Bolt Per  
Hole 1000  
Dimensions  
Cat.  
No.  
Pkg.  
Qty.  
Wire  
Range  
Max.  
Ins.  
A
B
C
M
1
RH9711  
RH9731  
RH9751  
100  
100  
100  
1AN  
1AN  
1AN  
.500  
.500  
.500  
"
54  
54  
54  
2.14  
2.14  
2.34  
.77  
.77  
.77  
.44 1.81  
.44 1.81  
.54 1.90  
3
⁄"  
1
⁄"  
1
3
1
RJ9711  
RJ9731  
RJ9751  
100  
100  
100  
1/0AN  
1/0AN  
1/0AN  
.550  
.550  
.550  
⁄"  
80  
80  
80  
2.35  
2.35  
2.49  
.83  
.83  
.89  
.46 1.97  
.46 1.97  
.55 2.04  
1
RH717  
RH727  
RH737  
RH757  
100  
100  
100  
100  
1/0  
1/0  
1/0  
1/0  
.629  
.629  
.629  
.629  
"
80  
80  
80  
80  
2.14  
2.14  
2.14  
2.34  
.77  
.77  
.77  
.77  
.43 1.81  
.43 1.81  
.43 1.81  
.54 1.90  
5
⁄"  
3
1
⁄"  
3
RK9731  
RK9751  
100  
100  
2/0AN  
2/0AN  
.610  
.610  
"
70  
70  
2.52  
2.60  
.93  
.93  
.55 2.14  
.55 2.15  
1
⁄"  
Stock Thickness:  
RH = .05  
1
RJ717  
RJ727  
RJ737  
RJ757  
100  
100  
100  
100  
2/0  
2/0  
2/0  
2/0  
.675  
.675  
.675  
.675  
"
80  
80  
80  
80  
2.34  
2.34  
2.34  
2.48  
.83  
.83  
.83  
.89  
.46 1.96  
.46 1.96  
.46 1.96  
.54 2.03  
5
⁄"  
3
RJ = .06  
1
RK = .06  
3
RL9731  
RL9751  
100  
100  
3/0AN  
3/0AN  
.680  
.680  
"
120 2.83 1.04  
120 2.83 1.04  
.57 2.36  
.57 2.36  
RL = .07  
1
⁄"  
RM = .07  
1
RK717  
RK727  
RK737  
100  
100  
100  
3/0  
3/0  
3/0  
.765  
.765  
.765  
"
84  
84  
84  
2.60  
2.60  
2.60  
.93  
.93  
.93  
.54 2.21  
.54 2.21  
.54 2.21  
5
⁄"  
3
⁄"  
3
RM9731  
RM9751  
100  
100  
4/0AN  
4/0AN  
.750  
.750  
"
160 3.00 1.13  
160 3.00 1.13  
.66 2.51  
.66 2.51  
1
⁄"  
3
RL737  
RL757  
100  
100  
4/0  
4/0  
.785  
.785  
"
130 2.83 1.04  
130 2.83 1.04  
.57 2.35  
.57 2.35  
1
⁄"  
3
RM737  
RM747  
RM757  
100  
100  
100  
250MCM  
250MCM  
250MCM  
.868  
.868  
.868  
"
130 3.00 1.13  
.65 2.51  
.65 2.51  
.65 2.51  
7
1
"
130 3.00 1.13  
A NAircraft Wire  
U.L. Listed E9809  
Installing tools: TBM6/TBM6S, WT2130A (RD Series only)  
Note: Not available on Mylar Tape.  
83  
Telecom 1-800-685-9452  
Terminals  
®
®
Heat Shrinkable Ring Terminals—Expanded Insulation Support  
Wt./Lbs.  
Dimensions  
Cat.  
No.  
Pkg.  
Qty.  
Wire  
Range  
Max.  
Ins.  
Bolt  
Per  
Hole 1000  
A
B
C
M
RAS18-6X 100  
RAS18-8X 100  
RAS18-10X 100  
22-18  
22-18  
22-18  
.170  
.170  
.170  
#6  
#8  
#10  
2
3
2
1.23  
1.26  
1.26  
.25  
.31  
.31  
.27 1.10  
.27 1.10  
.27 1.10  
RBS14-6X 100  
RBS14-8X 100  
RBS14-10X 100  
16-14  
16-14  
16-14  
.200  
.200  
.200  
#6  
#8  
#10  
3
3
1.23  
1.23  
1.26  
.25  
.25  
.31  
.27 1.10  
.27 1.10  
.27 1.10  
31⁄  
2
RCS10-6X  
RCS10-8X  
50  
50  
12-10  
12-10  
12-10  
12-10  
.250  
.250  
.250  
.250  
#6  
#8  
3
5
5
6
1.34  
1.34  
1.34  
1.34  
.31  
.37  
.37  
.49  
.27 1.15  
.27 1.15  
.27 1.15  
.32 1.15  
These ring terminals are self-insulated with  
heat shrinkable nylon and internally coated  
sealant. Upon completed installation, a fully  
sealed connection is achieved to protect the  
joint against the degrading effects of galvanic  
action, corrosion, and environmental exposure.  
RCS10-10X 50  
RCS10-14X 50  
#10  
1
⁄"  
U.L. Listed E9809  
Installing tool: WT1255  
Note: Not available on Mylar Tape.  
RAS & RBS stock thickness: .03  
RCS stock thickness: .04  
84  
Telecom 1-800-685-9452  
Vinyl Terminals  
®
®
Vinyl Insulated Ring—Insulation Support  
Wt./Lbs.  
Dimensions  
Cat.  
No.  
Pkg.  
Qty.  
Wire  
Range  
Max.  
Ins.  
Bolt  
Per  
Hole 1000  
A
B
C
M
18RA-4  
RA77  
18RA-6  
RA857  
18RA-8  
RA867  
100  
1000  
100  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
.150  
.150  
.150  
.150  
.150  
.150  
.150  
.150  
.150  
.150  
.150  
.150  
.150  
.150  
#4  
#4  
3
3
3
3
3
3
3
3
4
4
4
4
4
4
.97  
.97  
.31  
.31  
.25  
.25  
.31  
.31  
.31  
.31  
.50  
.50  
.50  
.50  
.54  
.54  
.27  
.27  
.27  
.27  
.27  
.27  
.27  
.27  
.37  
.37  
.37  
.37  
.37  
.37  
.81  
.81  
.81  
.81  
.81  
.81  
.81  
.81  
.88  
.88  
.88  
.88  
.91  
.91  
#6  
.94  
1000  
100  
#6  
.94  
#8  
.97  
1000  
#8  
.97  
18RA-10 100  
#10  
.97  
RA877  
18RA-14 100  
RA717 1000  
18RA-516 100  
RA727 1000  
1000  
#10  
.97  
1
"
1.13  
1.13  
1.13  
1.13  
1.24  
1.24  
1
⁄"  
These ring terminals are self-insulated with a  
PVC insulation sleeve of extra length to give  
protection and relieve bending stress at wire’s  
flex point. Brazed seam barrel is serrated to  
obtain high pull-out value. Terminal is made of  
high conductivity electrolytic copper, electro-tin  
plated. Insulation material is color-coded:  
5
⁄"  
5
⁄"  
3
18RA-38 100  
RA737  
⁄"  
3
1000  
⁄"  
14RB-4  
100  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
.170  
.170  
.170  
.170  
.170  
.170  
.170  
.170  
.170  
.170  
.170  
.170  
.170  
.170  
#4  
#4  
3
3
3
3
3
3
3
3
4
4
4
4
4
4
.94  
.94  
.25  
.25  
.31  
.31  
.31  
.31  
.31  
.31  
.50  
.50  
.50  
.50  
.54  
.54  
.27  
.27  
.27  
.27  
.27  
.27  
.27  
.27  
.38  
.38  
.38  
.38  
.38  
.38  
.81  
.81  
.81  
.81  
.81  
.81  
.81  
.81  
.89  
.89  
.89  
.89  
.91  
.91  
RB1327 1000  
Color Code  
red  
Wire Range  
22-16  
14RB-6  
RB857  
14RB-8  
RB867  
100  
1000  
100  
#6  
.97  
#6  
.97  
blue  
18-14  
#8  
.97  
yellow  
12-10  
1000  
#8  
.97  
14RB-10 100  
#10  
.97  
RB877  
14RB-14 100  
RB717 1000  
14RB-516 100  
1000  
#10  
.97  
Stock Thickness:  
RA & RB = .03  
1
"
1.14  
1.14  
1.15  
1.15  
1.16  
1.16  
1
⁄"  
5
⁄"  
RC  
=
.04  
5
RB727  
14RB-38 100  
RB-737 1000  
1000  
⁄"  
3
⁄"  
3
⁄"  
10RC-6  
RC337  
10RC-8  
RC777  
10RC-10  
RC367  
10RC-14  
RC717  
50  
500  
50  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
.210  
.210  
.210  
.210  
.210  
.210  
.210  
.210  
.210  
.210  
.210  
.210  
#6  
#6  
5
5
5
5
5
5
6
6
6
6
6
6
1.06  
1.06  
1.06  
1.06  
1.06  
1.06  
1.16  
1.16  
1.17  
1.17  
1.29  
1.29  
.31  
.31  
.31  
.31  
.31  
.31  
.50  
.50  
.50  
.50  
.59  
.59  
.27  
.27  
.27  
.27  
.27  
.27  
.27  
.27  
.37  
.37  
.44  
.44  
.90  
.90  
.90  
.90  
.90  
.90  
.90  
.90  
.92  
.92  
.99  
.99  
#8  
500  
50  
#8  
#10  
500  
50  
500  
#10  
1
"
1
⁄"  
5
10RC-516 50  
⁄"  
5
RC707  
10RC-38  
RC737  
500  
50  
500  
⁄"  
3
⁄"  
3
⁄"  
U.L. Listed E9809  
Installing tools: WT145C, WT2000, WT112M, ERG-2001, ERG-2003, WT2130A (RC,  
RBC)  
Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications (i.e.  
12050 tool and application dies).  
Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.)  
85  
Telecom 1-800-685-9452  
Vinyl Terminals  
®
®
Vinyl Insulated Ring—Expanded Insulation Support  
Wt./Lbs.  
Dimensions  
Cat.  
No.  
Pkg.  
Qty.  
Wire  
Range  
Max.  
Ins.  
Bolt  
Per  
Hole 1000  
A
B
C
M
18RA-6X  
18RA-8X  
100  
100  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
.170  
.170  
.170  
.170  
.170  
.170  
.170  
.170  
#6  
#8  
3
3
3
3
3
4
4
4
.97  
.97  
.31  
.31  
.31  
.31  
.31  
.50  
.50  
.54  
.27  
.27  
.27  
.27  
.27  
.37  
.37  
.35  
.81  
.81  
.81  
.81  
.81  
.88  
.88  
.91  
RA867-170 1000  
#8  
.97  
18RA-10X  
RA877-170 1000  
18RA-14X 100  
RA727-170 1000  
18RA-38X  
100  
#10  
.97  
.97  
1.13  
1.13  
1.24  
#10  
1
"
5
⁄"  
3
100  
⁄"  
14RB-4X  
14RB-6X  
100  
100  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
.200  
.200  
.200  
.200  
.200  
.200  
.200  
.200  
.200  
.200  
.200  
#4  
#6  
3
3
3
3
3
3
3
4
4
4
4
.94  
.97  
.25  
.31  
.31  
.31  
.31  
.31  
.31  
.50  
.50  
.50  
.54  
.27  
.27  
.27  
.27  
.27  
.27  
.27  
.38  
.38  
.38  
.35  
.81  
.81  
.81  
.81  
.81  
.81  
.81  
.89  
.89  
.89  
.91  
Catalog numbers with the suffix X indicate an  
expanded insulation support. This means a  
wider wire entry to accommodate heavy wall  
insulation. Ring terminals won’t fall free even if  
the mounting screw loosens.  
RB857-200 1000  
#6  
.97  
14RB-8X  
RB867-200 1000  
14RB-10X 100  
RB877-200 1000  
14RB-14X 100  
RB717-200 1000  
14RB-516X  
14RB-38X  
100  
#8  
.97  
#8  
.97  
#10  
.97  
#10  
.97  
1
"
1.14  
1.14  
1.15  
1.16  
Stock Thickness:  
1
⁄"  
RA & RB  
RC  
=
=
.03  
.04  
5
100  
100  
⁄"  
3
⁄"  
10RC-6X  
50  
500  
50  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
.250  
.250  
.250  
.250  
.250  
.250  
.250  
.250  
.250  
.250  
.250  
#6  
#6  
5
5
5
5
5
5
6
6
6
6
6
1.06  
1.06  
1.06  
1.06  
1.06  
1.06  
1.16  
1.16  
1.17  
1.29  
1.29  
.31  
.31  
.31  
.31  
.31  
.31  
.50  
.50  
.50  
.59  
.59  
.27  
.27  
.27  
.27  
.27  
.27  
.27  
.27  
.37  
.44  
.44  
.90  
.90  
.90  
.90  
.90  
.90  
.90  
.90  
.92  
.99  
.99  
RC337-250  
10RC-8X  
#8  
RC777-250  
10RC-10X  
RC367-250  
10RC-14X  
RC717-250  
10RC-516X  
10RC-38X  
RC737-250  
500  
50  
#8  
#10  
500  
50  
#10  
1
"
1
500  
50  
⁄"  
5
⁄"  
3
50  
⁄"  
3
500  
⁄"  
U.L. Listed E9809  
Installing tools: WT145C, WT2000, WT112M, ERG-2001, ERG-2003, WT2130A (RC,  
RBC)  
Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications  
(i.e. 12050 tool and application dies).  
Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.)  
86  
Telecom 1-800-685-9452  
U.L. 94V-0 Rated Ring Terminals  
®
®
Vinyl Insulated Ring  
Max.  
Ins.  
Dia.  
Dimensions  
Cat.  
No.  
Stud  
Size  
Wire  
Range  
A
B
C
M
Series RDV—Aircraft Wire AN  
RDV10161  
RDV10361  
RDV10711  
#8  
.270  
.270  
.270  
9,8,7  
9,8,7  
9,8,7  
1.40  
1.40  
1.45  
.41  
.41  
.45  
.24  
.24  
.27  
1.20  
1.20  
1.22  
#10  
1
⁄"  
C
Note: Not available on Mylar Tape.  
Stock Thickness: .04  
* Brazed Seam, Lolly-Pop Style Tongue  
NEW  
RD and RE sizes now available with a U.L. 94V-O Vinyl Insulator  
87  
Telecom 1-800-685-9452  
Tefzel® Insulated Terminals  
®
®
Tefzel Insulated Ring—Insulation Grip  
Max.  
Dimensions  
Cat.  
No.  
Stud  
Size  
Ins.  
Wire  
Range  
Dia.  
A
B
C
M
Series RAT—For U.L. 94V-O Flamability Rating/High Temperature and Chemical  
Resistance.  
RAT853  
RAT863  
RAT873  
RAT713  
#6  
#8  
.140  
.140  
.140  
.140  
22-18  
22-18  
22-18  
22-18  
.81  
.84  
.25  
.31  
.31  
.46  
.25  
.25  
.25  
.31  
.69  
.69  
.69  
.84  
#10  
.84  
1.07  
1
"
Series RBT  
RBT853  
RBT863  
RBT873  
RBT713  
#6  
#8  
.170  
.170  
.170  
.170  
16-14  
16-14  
16-14  
16-14  
.84  
.84  
.31  
.31  
.31  
.46  
.25  
.25  
.25  
.31  
.69  
.69  
.69  
.81  
Stock Thickness:  
RAT & RBT = .03  
RCT = .04  
#10  
.84  
1
⁄"  
1.08  
Series RCT  
RCT333  
RCT863  
RCT363  
RCT713  
RCT703  
RCT733**  
#6  
#8  
.210  
.210  
.210  
.210  
.210  
.210  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
1.00  
1.00  
1.00  
1.11  
1.23  
1.29  
.37  
.37  
.37  
.52  
.52  
.58  
.27  
.27  
.27  
.32  
.31  
.35  
.81  
.81  
Package Quantities:  
RAT & RBT = 1000 pcs.  
RCT = 500 pcs.  
#10  
.81  
1
"
.85  
5
"
.96  
3
"
1.00  
** Not available on tape.  
U.L. Listed E9809  
Installing Tools: ERG2001, WT112M, WT145C.  
Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications (i.e.  
12050 tool and application dies).  
Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.)  
88  
Telecom 1-800-685-9452  
Non-Insulated Terminals  
®
®
Non-Insulated Ring  
Wt./Lbs.  
Per  
1000  
Dimensions  
Cat.  
No.  
Pkg.  
Qty.  
Wire  
Range  
Bolt  
Hole  
A
B
C
M
A18-4  
A18-6  
A85  
100  
100  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
#4  
#6  
#6  
#8  
#8  
2
2
2
2
2
2
2
3
3
3
3
3
3
.75  
.72  
.72  
.75  
.75  
.75  
.75  
.92  
.92  
.92  
.99  
1.06  
1.06  
.31  
.25  
.25  
.31  
.31  
.31  
.31  
.50  
.50  
.50  
.54  
.72  
.72  
.27  
.27  
.27  
.27  
.27  
.27  
.27  
.37  
.37  
.37  
.35  
.38  
.38  
.59  
.59  
.59  
.59  
.59  
.59  
.59  
.67  
.67  
.67  
.67  
.70  
.70  
1000  
100  
A18-8  
A86  
1000  
100  
A18-10  
A87  
#10  
1000  
100  
#10  
1
4
A18-14  
A71  
⁄"  
1
4
1000  
1000  
1000  
100  
⁄"  
5
16  
A72  
"
3
1
1
A73  
⁄"  
These non-insulated ring terminals are made of  
electrolytic copper for high conductivity. They  
can be installed with crimping tools having a  
single indentor or double indentor (recom-  
mended for solid wire). Serrated barrel increas-  
es grip on wire. Wire range identification is  
stamped on the tongue of each terminal.  
A18-12  
A75  
⁄"  
2
1000  
⁄"  
B14-4  
B132  
B14-6  
B133  
B14-8  
B86  
100  
1000  
100  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
#4  
#4  
2
2
2
2
3
3
3
3
6
6
6
6
6
6
6
6
6
6
.72  
.72  
.75  
.75  
.75  
.75  
.75  
.75  
.93  
.93  
.93  
.93  
.96  
.96  
1.06  
1.06  
.75  
.72  
.25  
.25  
.31  
.31  
.31  
.31  
.31  
.31  
.50  
.50  
.50  
.50  
.54  
.54  
.72  
.72  
.31  
.25  
.27  
.27  
.27  
.27  
.27  
.27  
.27  
.27  
.38  
.38  
.38  
.38  
.35  
.35  
.38  
.38  
.27  
.27  
.59  
.59  
.59  
.59  
.59  
.59  
.59  
.59  
.68  
.68  
.68  
.68  
.68  
.68  
.70  
.70  
.59  
.59  
#6  
1000  
100  
#6  
#8  
1000  
100  
#8  
Most standard bulk catalog numbers can  
be put on Mylar Tape for reel fed applica-  
tions (i.e. 12050 tool and applicaton dies).  
Consult tech service.  
B14-10  
B87  
#10  
1000  
100  
#10  
1
B14-14  
B71  
"
1
1000  
"
5
B14-516 100  
5
16  
"
B72  
1000  
100  
"
3
3
1
1
B14-38  
B73  
"
Please put the suffix M for Mylar Tape  
RA2573M.  
1000  
100  
B14-12  
B75  
1000  
1000  
1000  
"
B85  
#6  
#8  
(Bulk number 1000 and 500 packages.)  
B134  
BC14-6  
BC85  
BC14-8  
BC86  
BC14-10  
BC87  
BC14-14  
BC71  
50 heavy duty 16-14 #6  
4
4
.81  
.81  
.25  
.25  
.29  
.29  
.68  
.68  
500  
use C tooling #6  
Stock Thickness:  
A & B = .03  
BC = .05  
50 heavy duty 16-14 #8  
4
.87  
.39  
.29  
.68  
500  
use C tooling #8  
4
.87  
.39  
.29  
.68  
50 heavy duty 16-14 #10  
5
5
.87  
.87  
.39  
.39  
.29  
.29  
.68  
.68  
500use C tooling  
#10  
C = .04  
50 heavy duty 16-14 1⁄  
4
"
5
.93  
.51  
.29  
.68  
1
500  
use C tooling  
"  
5
.93  
.51  
.29  
.68  
BC14-516 50 heavy duty 16-14 516  
"
6
6
1.04  
1.04  
.54  
.54  
.38  
.38  
.77  
.77  
5
BC72  
BC14-38  
BC79  
BC14-12  
BC75  
500  
use C tooling 16  
"
50 heavy duty 16-14 3⁄  
8
"
"
6
1.09  
.63  
.38  
.77  
3
500  
use C tooling  
6
1.09  
.63  
.38  
.77  
1
50 heavy duty 16-14  
"
"  
6
6
1.32  
1.32  
.76  
.76  
.54  
.54  
.94  
.94  
1
500  
use C tooling  
2
C10-6  
C33  
50  
500  
50  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
#6  
#6  
4
4
5
5
5
5
7
7
7
8
8
7
7
7
7
7
.82  
.82  
.31  
.31  
.31  
.31  
.38  
.38  
.31  
.50  
.50  
.50  
.50  
.59  
.59  
.59  
.72  
.72  
.27  
.27  
.27  
.27  
.27  
.27  
.27  
.27  
.27  
.38  
.38  
.45  
.45  
.45  
.38  
.38  
.66  
.66  
.66  
.66  
.66  
.66  
.66  
.66  
.66  
.73  
.73  
.80  
.80  
.80  
.84  
.84  
C10-8  
C77  
#8  
.82  
500  
50  
#8  
.82  
C10-10  
C26  
#10  
#10  
.85  
500  
1000  
50  
.85  
C36  
#10  
.82  
1
C10-14  
C71  
"
.91  
1
500  
50  
"
.91  
5
C10-516  
C70  
"
"
"
.98  
5
500  
1000  
50  
.98  
5
C72  
1.10  
1.10  
1.10  
1.21  
1.21  
3
3
1
1
C10-38  
C73  
"
500  
50  
⁄"  
C10-12  
C75  
⁄"  
2
500  
⁄"  
U.L. Listed E9809  
Installing tools: WT111M, WT112M, WT110M,  
ERG-2002, WT1300, WT2000, WT3155A  
89  
Telecom 1-800-685-9452  
Non-Insulated Terminals  
®
®
Non-Insulated Ring  
Wt./Lbs.  
Per  
1000  
Dimensions  
Cat.  
No.  
Pkg.  
Qty.  
Wire  
Range  
Bolt  
Hole  
A
B
C
M
D8-10  
D26*  
25  
200  
25  
9-8-7  
9-8-7  
9-8-7  
9-8-7  
9-8-7  
9-8-7  
9-8-7  
9-8-7  
9-8-7  
9-8-7  
#10  
16  
16  
14  
14  
16  
16  
14  
14  
14  
14  
1.13  
1.13  
1.13  
1.13  
1.32  
1.32  
1.32  
1.32  
1.49  
1.49  
.48  
.48  
.48  
.48  
.59  
.59  
.59  
.59  
.82  
.82  
.36  
.36  
.36  
.36  
.49 1.03  
.49 1.03  
.49 1.03  
.49 1.03  
.55 1.09  
.55 1.09  
.90  
.90  
.90  
.90  
#10  
1
D8-14  
D71*  
"
1
200  
25  
"
5
D8-516  
D72*  
D8-38  
D73*  
D8-12  
D75*  
"
C
5
200  
25  
"
3
3
1
1
"
200  
25  
⁄"  
⁄"  
200  
⁄"  
These non-insulated ring terminals are made of  
electrolytic copper for high conductivity. They  
can be installed with crimping tools having a  
single indentor or double indentor (recommend-  
ed for solid wire). Serrated barrel increases grip  
on wire. Wire range identification is stamped on  
the tongue of each terminal.  
D10161  
D10361  
D10711  
D10721  
D10731  
D975*  
200  
200  
200  
200  
200  
200  
9-8-7  
9-8-7  
9-8-7  
9-8-7  
9-8-7  
9-8-7  
#8  
12  
12  
12  
12  
12  
12  
1.15  
1.15  
1.20  
1.28  
1.28  
1.46  
.41  
.41  
.45  
.56  
.56  
.83  
.28  
.28  
.36  
.36 1.00  
.36 1.00  
.49 1.06  
.95  
.95  
.97  
#10  
1
"
5
"
3
1
⁄"  
E6-10  
E26*  
E6-14  
E71*  
E6-516  
E72*  
E6-38  
E73*  
E6-12  
E75*  
20  
200  
20  
6-5  
6-5  
6-5  
6-5  
6-5  
6-5  
6-5  
6-5  
6-5  
6-5  
#10  
17  
17  
20  
20  
20  
20  
20  
20  
20  
20  
1.13  
1.13  
1.13  
1.13  
1.32  
1.32  
1.32  
1.32  
1.49  
1.49  
.48  
.48  
.48  
.48  
.60  
.60  
.60  
.60  
.82  
.82  
.36  
.36  
.36  
.36  
.49 1.03  
.49 1.03  
.49 1.03  
.49 1.03  
.55 1.08  
.55 1.08  
.90  
.90  
.90  
.90  
#10  
1
"
Stock Thickness:  
D & E = .06  
1
200  
20  
"
5
"
5
F = .07  
200  
20  
"
3
3
1
1
"
D10, E10, F10 = .04  
D975 & F975 = .04  
200  
20  
⁄"  
⁄"  
200  
⁄"  
E10261  
E10711  
E10721  
E10731  
200  
200  
200  
200  
6-5  
6-5  
6-5  
6-5  
#10  
14  
14  
14  
14  
1.26  
1.26  
1.38  
1.38  
.49  
.49  
.60  
.60  
.24 1.02  
1
"
.27  
.99  
5
"
.34 1.04  
.34 1.04  
3
⁄"  
F4-10  
F26*  
20  
200  
20  
4-3  
4-3  
4-3  
4-3  
4-3  
4-3  
4-3  
4-3  
4-3  
4-3  
#10  
24  
24  
25  
25  
25  
25  
25  
25  
25  
25  
1.16  
1.16  
1.16  
1.16  
1.35  
1.35  
1.35  
1.35  
1.52  
1.52  
.48  
.48  
.48  
.48  
.60  
.60  
.60  
.60  
.82  
.82  
.36  
.36  
.36  
.36  
.49 1.06  
.49 1.06  
.49 1.06  
.49 1.06  
.55 1.11  
.55 1.11  
.93  
.93  
.93  
.93  
#10  
1
F4-14  
F71*  
"
1
200  
20  
"
5
F4-516  
F72*  
F4-38  
F73*  
F4-12  
F75*  
"
5
200  
20  
"
3
3
1
1
"
200  
20  
⁄"  
⁄"  
200  
⁄"  
F10261  
F10711  
F10721  
F10731  
F975*  
100  
100  
100  
100  
200  
4-3  
4-3  
4-3  
4-3  
4-3  
#10  
20  
20  
20  
20  
20  
1.37  
1.37  
1.42  
1.42  
1.49  
.55  
.55  
.62  
.62  
.83  
.30 1.07  
.30 1.07  
.34 1.08  
.34 1.08  
.45 1.10  
1
⁄"  
5
"
1
⁄"  
* Brazed Seam, Lolly-Pop Style Tongue  
Installing tools: WT115A D, E, F and G, WT3155A, (D-Series only), TBM6/TBM6S,  
WT3175  
Installing dies: 11802 INDENTOR (D-E-F-G), D-11803-NEST, E-11805-NEST, F-11806-  
NEST (all ordered separately)  
Note: Not available on Mylar Tape.  
90  
Telecom 1-800-685-9452  
Non-Insulated Terminals  
®
®
Non-Insulated Ring  
Wt./Lbs.  
Dimensions  
Cat.  
No.  
Pkg.  
Qty.  
Wire  
Range  
Bolt  
Hole  
Per  
1000  
A
B
C
M
1
G2-14  
G2-516  
G2-38  
G2-12  
10  
10  
10  
10  
2-1  
2-1  
2-1  
2-1  
"
50  
50  
50  
50  
1.59  
1.59  
1.59  
1.79  
.69  
.69  
.69  
.80  
.40 1.26  
.40 1.26  
.40 1.26  
.49 1.36  
5
⁄"  
3
1
⁄"  
1
3
3
3
3
H10-14  
J20-38  
K30-38  
L40-38  
M250-38  
10  
10  
5
1/0  
2/0  
"
50  
70  
1.65  
1.84  
2.08  
.77  
.83  
.93  
.43 1.32  
.46 1.46  
.54 1.69  
.57 1.77  
.65 1.91  
⁄"  
3/0  
"
"
82  
5
4/0  
250MCM  
100  
135  
2.25 1.04  
2.40 1.12  
5
⁄"  
G926  
G971  
G972  
G973  
G975  
G976  
100  
100  
100  
100  
100  
100  
1-2  
1-2  
1-2  
1-2  
1-2  
1-2  
#10  
40  
40  
40  
40  
40  
40  
1.59  
1.59  
1.59  
1.59  
1.79  
1.79  
.69  
.69  
.69  
.69  
.80  
.80  
.40 1.26  
.40 1.26  
.40 1.26  
.40 1.26  
.49 1.36  
.49 1.36  
These non-insulated ring terminals are made of  
electrolytic copper for high conductivity. They  
can be installed with crimping tools having a  
single indentor or double indentor (recom-  
mended for solid wire). Serrated barrel increas-  
es grip on wire. Wire range identification is  
stamped on the tongue of each terminal.  
1
⁄"  
5
⁄"  
3
1
5
1
H971  
H972  
H973  
H975  
H976  
100  
100  
100  
100  
100  
1AN-1/0  
1AN-1/0  
1AN-1/0  
1AN-1/0  
1AN-1/0  
"
50  
50  
50  
50  
50  
1.65  
1.65  
1.65  
1.85  
1.85  
.77  
.77  
.77  
.77  
.77  
.43 1.32  
.43 1.32  
.43 1.32  
.54 1.41  
.54 1.41  
5
⁄"  
3
Stock Thickness:  
G & H = .05  
J & K = .06  
L & M = .07  
1
5
1
J971  
J972  
J973  
J974  
J975  
J976  
100  
100  
100  
100  
100  
100  
1/0AN-2/0  
1/0AN-2/0  
1/0AN-2/0  
1/0AN-2/0  
1/0AN-2/0  
1/0AN-2/0  
"
60  
60  
60  
60  
60  
60  
1.94  
1.94  
1.99  
1.99  
1.99  
1.99  
.84  
.84  
.84  
.89  
.89  
.89  
.48 1.53  
.48 1.53  
.53 1.58  
.51 1.56  
.51 1.56  
.51 1.56  
5
⁄"  
3
7
1
5
1
K971  
K972  
K973  
K974  
K975  
K976  
100  
100  
100  
100  
100  
100  
2/0AN-3/0  
2/0AN-3/0  
2/0AN-3/0  
2/0AN-3/0  
2/0AN-3/0  
2/0AN-3/0  
"
76  
76  
76  
76  
76  
76  
2.08  
2.08  
2.08  
2.08  
2.08  
2.08  
.93  
.93  
.93  
.93  
.93  
.93  
.54 1.69  
.54 1.69  
.54 1.69  
.54 1.70  
.54 1.70  
.54 1.70  
5
⁄"  
3
7
1
5
3
L973  
L974  
L975  
L976  
100  
100  
100  
100  
3/0AN-4/0  
3/0AN-4/0  
3/0AN-4/0  
3/0AN-4/0  
"
92  
92  
92  
92  
2.25 1.04  
2.25 1.04  
2.25 1.04  
2.25 1.04  
.57 1.77  
.57 1.77  
.57 1.77  
.57 1.77  
7
⁄"  
1
5
M972  
M973  
M974  
M975  
100 4/0AN-250MCM 516  
"
112  
112  
112  
112  
2.28 1.12  
2.40 1.12  
2.40 1.12  
2.40 1.12  
.62 1.90  
.65 1.91  
.65 1.91  
.65 1.91  
3
100 4/0AN-250MCM ⁄  
8
"
100 4/0AN-250MCM 716  
"
1
100 4/0AN-250MCM "  
2
ANAircraft Wire  
Installing tools: TBM6/TBM6S, WT3175 (G, H, J Series only)  
Note: Not available on Mylar Tape.  
91  
Telecom 1-800-685-9452  
Flag Terminals  
®
®
Non-Insulated Flag  
Wt./Lbs.  
Per  
1000  
Dimensions  
Cat.  
No.  
Pkg.  
Qty.  
Wire  
Range  
Bolt  
Hole  
A
B
C
M
AB14-6A  
AB51  
100  
1000  
100  
22-14  
22-14  
22-14  
22-14  
22-14  
22-14  
#6  
#6  
21⁄  
21⁄  
21⁄  
21⁄  
21⁄  
21⁄  
2
.55  
.55  
.55  
.55  
.55  
.55  
.31  
.31  
.31  
.31  
.31  
.31  
.22  
.22  
.22  
.22  
.22  
.22  
.39  
.39  
.39  
.39  
.39  
.39  
2
AB14-8A  
AB52  
#8  
2
1000  
#8  
#10  
#10  
2
AB14-10A 100  
AB53  
2
1000  
2
C51  
500  
50  
12-10  
12-10  
12-10  
12-10  
12-10  
#6  
#8  
5
5
5
5
5
.66  
.66  
.66  
.66  
.66  
.31  
.31  
.31  
.31  
.31  
.25  
.25  
.25  
.25  
.25  
.48  
.48  
.48  
.48  
.48  
C10-8A  
C52  
500  
50  
#8  
C10-10A  
C53  
#10  
#10  
500  
Flag terminals allow a 90° connection to the  
terminal block without bending the wire.  
D236  
D226  
D271  
200  
200  
200  
9,8,7  
9,8,7  
9,8,7  
#10  
.83  
.88  
.92  
.50  
.50  
.50  
.25  
.29  
.33  
.59  
.64  
.68  
#10  
1
⁄"  
Stock Thickness:  
AB = .03  
C = .04  
E226  
E271  
E272  
200  
200  
200  
6,5  
6,5  
6,5  
#10  
.93  
.97  
.50  
.50  
.50  
.29  
.33  
.41  
.69  
.73  
.81  
1
⁄"  
5
"
1.05  
F226  
F271  
F272  
F273  
200  
200  
200  
200  
4,3  
4,3  
4,3  
4,3  
#10  
1.07  
1.10  
1.18  
1.20  
.56  
.63  
.63  
.63  
.33  
.33  
.41  
.43  
.80  
.80  
.88  
.90  
D = .06  
1
⁄"  
E = .06  
5
⁄"  
3
⁄"  
F = .07  
G = .08  
1
G671  
G672  
G673  
100  
100  
100  
2
2
2
"
1.20  
1.28  
1.32  
.63  
.63  
.63  
.33  
.41  
.89  
.97  
5
⁄"  
3
"
.46 1.02  
U.L. Listed E9809  
Installing tools: WT119, ERG-2004, WT129 = D, E, F, G  
Note: Not available on Mylar Tape.  
92  
Telecom 1-800-685-9452  
Fork Terminals  
®
®
Nylon Insulated Fork—Insulation Grip  
Wt./Lbs.  
Per  
Hole 1000  
Dimensions  
Cat.  
No.  
Pkg.  
Qty.  
Wire  
Range  
Max.  
Ins.  
Bolt  
A
B
C
M
RA18-6F  
RA1103  
RA18-8F  
RA1123  
100  
1000  
100  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
.136  
.136  
.136  
.136  
#6  
#6  
#8  
#8  
3
3
3
3
3
3
4
4
.83  
.83  
.86  
.86  
.86  
.86  
.95  
.95  
.25  
.25  
.31  
.31  
.31  
.31  
.44  
.44  
.25  
.25  
.25  
.25  
.25  
.25  
.31  
.31  
.71  
.71  
.71  
.71  
.71  
.71  
.70  
.70  
1000  
RA18-10F 100  
.136 #10  
RA1153  
1000  
.136 #10  
.136  
.136  
1
RA18-14F 100  
⁄"  
1
RA1163  
1000  
⁄"  
Fork terminals with nylon insulation sleeves,  
recommended for temperatures up to 105°C.  
Inner bronze insulation grip sleeve lengthens  
flex radius of conductor and eliminates conduc-  
tor creep. Nylon jacket is color-coded.  
RB14-6F  
RB1113  
RB14-8F  
RB1123  
100  
1000  
100  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
.162  
.162  
.162  
.162  
#6  
#6  
#8  
#8  
31⁄  
31⁄  
31⁄  
31⁄  
4
4
4
4
6
6
6
2
.87  
.87  
.87  
.87  
.87  
.87  
.95  
.95  
.74  
.95  
.95  
.31  
.31  
.31  
.31  
.38  
.38  
.44  
.44  
.28  
.31  
.31  
.25  
.25  
.25  
.25  
.25  
.25  
.28  
.28  
.16  
.25  
.25  
.71  
.71  
.71  
.71  
.71  
.71  
.74  
.74  
.60  
.79  
.79  
2
2
1000  
2
RB14-10F 100  
.162 #10  
RB1153  
RB14-14F 100  
RB1163  
RB1103  
RB1124  
RB1154  
1000  
.162 #10  
Stock thickness same as ring terminal of same  
size.  
1
.162  
.162  
.162  
.190  
"
1
1000  
1000  
1000  
1000  
⁄"  
#6  
#8  
.190 #10  
RC10-6F  
RC1113  
RC10-8F  
RC1123  
RC10-10F  
RC1153  
RC10-14F  
RC1163  
RC1124  
RC1154  
50  
500  
50  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
.210  
.210  
.210  
.210  
#6  
#6  
#8  
#8  
6
6
6
6
6
6
6
6
6
6
.97  
.97  
.31  
.31  
.37  
.37  
.37  
.37  
.50  
.50  
.37  
.37  
.27  
.27  
.27  
.27  
.27  
.27  
.27  
.27  
.27  
.27  
.81  
.81  
.81  
.81  
.81  
.81  
.86  
.86  
.91  
.91  
1.00  
1.00  
1.00  
1.00  
1.12  
1.12  
1.10  
1.10  
500  
50  
.210 #10  
500  
50  
500  
1000  
1000  
.210 #10  
1
.210  
.210  
.250  
"
1
⁄"  
#8  
.250 #10  
U.L. Listed E9809  
Installing tools: WT145C, WT2000, WT112M, ERG-2001, ERG-2003, WT145A,  
WT2130A (RC)  
Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications  
(i.e. 12050 tool and application dies).  
Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.)  
93  
Telecom 1-800-685-9452  
Fork Terminals  
®
®
Nylon Insulated Fork Flanged Tongue—Insulation Grip  
Wt./Lbs.  
Bolt Per  
Hole 1000  
Dimensions  
Cat.  
No.  
Pkg.  
Qty.  
Wire  
Range  
Max.  
Ins.  
A
B
C
M
RA18-6FS 100  
RA1203 1000  
RA18-8FS 100  
RA1223 1000  
RA18-10FS 100  
RA1253 1000  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
.136  
.136  
.136  
.136  
.136  
.136  
#6  
#6  
3
3
3
3
3
3
.75  
.75  
.89  
.89  
.93  
.93  
.28  
.28  
.31  
.31  
.38  
.38  
.16  
.16  
.23  
.23  
.26  
.26  
.62  
.62  
.65  
.65  
.68  
.68  
C
#8  
#8  
#10  
#10  
B
M
A
RB14-6FS 100  
RB1203 1000  
RB14-8FS 100  
RB1223 1000  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
.162  
.162  
.162  
.162  
.162  
.162  
#6  
#6  
4
4
4
4
4
4
.74  
.74  
.89  
.89  
.94  
.94  
.28  
.28  
.31  
.31  
.38  
.38  
.16  
.16  
.23  
.23  
.27  
.27  
.60  
.60  
.66  
.66  
.69  
.69  
Fork terminals allow easy installation because  
screw needs only to be loosened. Suffix S indi-  
cates a flanged-tongue fork with turned up tips  
for extra holding protection.  
#8  
#8  
RB14-10FS 100  
#10  
#10  
RB1253  
1000  
RC10-8FS  
RC1223  
50  
12-10  
12-10  
12-10  
12-10  
12-10  
.210  
.210  
.210  
.210  
.250  
#8  
#8  
#10  
#10  
#10  
5
5
5
5
5
.97  
.97  
1.00  
1.00  
1.12  
.34  
.34  
.38  
.38  
.38  
.23  
.23  
.26  
.26  
.26  
.73  
.73  
.74  
.74  
.86  
Stock thickness same as ring terminal of same  
size.  
500  
RC10-10FS 50  
RC1253  
RC1254  
500  
1000  
U.L. Listed E9809  
Installing tools: WT145C, WT2000, WT112M, ERG-2001, ERG-2003, WT145A,  
WT2130A (RC)  
Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications (i.e.  
12050 tool and application dies).  
turned up toes  
Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.)  
94  
Telecom 1-800-685-9452  
Fork Terminals  
®
®
Vinyl Insulated Fork—Insulation Support  
Wt./Lbs.  
Dimensions  
Cat.  
No.  
Pkg.  
Qty.  
Wire  
Range  
Max.  
Ins.  
Bolt  
Per  
Hole 1000  
A
B
C
M
18RA-6F  
RA1167  
18RA-8F  
RA1147  
18RA-10F  
RA1157  
100  
1000  
100  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
.150  
.150  
.150  
.150  
.150  
.150  
#6  
#6  
5
5
5
5
5
5
.94  
.94  
.97  
.97  
.97  
.97  
.25  
.25  
.31  
.31  
.31  
.31  
.27  
.27  
.27  
.27  
.27  
.27  
.81  
.81  
.81  
.81  
.81  
.81  
#8  
1000  
100  
#8  
#10  
#10  
1000  
14RB-6F  
RB647  
100  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
.170  
.170  
.170  
.170  
.170  
.170  
.170  
.170  
.170  
#6  
#6  
6
6
6
6
6
6
6
6
6
.97  
.97  
.31  
.31  
.30  
.31  
.31  
.31  
.31  
.44  
.44  
.27  
.27  
.25  
.27  
.27  
.27  
.27  
.38  
.38  
.81  
.81  
.75  
.81  
.81  
.81  
.81  
.89  
.89  
These fork terminals have extra-long PVC insu-  
lation sleeve for protection and stress relief at  
wire’s flex point. Brazed seam barrel is serrated  
for high pull-out value. Terminal is high con-  
ductivity electrolytic copper, electro-tin plated.  
Insulation is color-coded.  
1000  
14RB-6FS100  
#6  
.89  
14RB-8F  
RB657  
14RB-10F  
RB1157  
14RB-14F  
RB1717  
100  
1000  
100  
1000  
100  
1000  
#8  
.97  
#8  
.97  
#10  
.97  
#10  
.97  
1
"
1.11  
1.11  
1
⁄"  
Stock thickness same as ring terminal of same  
size.  
10RC-6F  
RC1337  
10RC-8F  
RC1147  
10RC-10F  
RC1157  
10RC-14F  
RC1167  
50  
500  
50  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
.210  
.210  
.210  
.210  
.210  
.210  
.210  
.210  
#6  
#6  
7
7
7
7
7
7
7
7
1.09  
1.09  
1.09  
1.09  
1.09  
1.09  
1.15  
1.15  
.38  
.38  
.38  
.38  
.38  
.38  
.50  
.50  
.27  
.27  
.27  
.27  
.27  
.27  
.37  
.37  
.90  
.90  
.90  
.90  
.90  
.90  
.90  
.90  
#8  
500  
50  
#8  
#10  
500  
50  
#10  
1
"
1
500  
⁄"  
U.L. Listed E9809  
Installing tools: WT145C, WT2000, WT112M, ERG-2001, ERG-2003, WT2130A (RC)  
Turned-up toes  
Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications (i.e.  
12050 tool and application dies).  
Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.)  
95  
Telecom 1-800-685-9452  
Fork Terminals  
®
®
Vinyl Insulation Fork—Expanded Insulation Support  
Wt./Lbs.  
Dimensions  
Cat.  
No.  
Pkg.  
Qty.  
Wire  
Range  
Max.  
Ins.  
Bolt  
Per  
Hole 1000  
A
B
C
M
18RA-6FX  
100  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
.170  
.170  
.170  
.170  
.170  
.170  
#6  
#6  
5
5
5
5
5
5
.94  
.94  
.97  
.97  
.97  
.97  
.25  
.25  
.31  
.31  
.31  
.31  
.27  
.27  
.27  
.27  
.27  
.27  
.81  
.81  
.81  
.81  
.81  
.81  
RA1167-170 1000  
18RA-8FX  
RA1147-170 1000  
18RA-10FX 100  
RA1157-170 1000  
100  
#8  
#8  
#10  
#10  
Fork terminals allow easy installation since the  
mounting screw does not have to be completely  
removed. Catalog numbers with the suffix X  
indicate an expanded insulation support. This  
means a wider wire entry to accommodate  
heavy wall insulation.  
14RB-6FX  
100  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
.200  
.200  
.200  
.200  
.200  
.200  
#6  
#6  
6
6
6
6
6
6
.97  
.97  
.97  
.97  
.97  
.97  
.31  
.31  
.31  
.31  
.31  
.31  
.27  
.27  
.27  
.27  
.27  
.27  
.81  
.81  
.81  
.81  
.81  
.81  
RB647-200 1000  
14RB-8FX 100  
RB657-200 1000  
14RB-10FX 100  
RB1157-200 1000  
#8  
#8  
#10  
#10  
10RC-8FX  
50  
12-10  
12-10  
12-10  
12-10  
12-10  
.250  
.250  
.250  
.250  
.250  
#8  
#8  
7
7
7
7
7
1.09  
1.09  
1.09  
1.09  
1.15  
.38  
.38  
.38  
.38  
.50  
.27  
.27  
.27  
.27  
.37  
.90  
.90  
.90  
.90  
.90  
Stock thickness same as ring terminal of same  
size.  
RC1147-250 500  
10RC-10FX 50  
RC1157-250 500  
10RC-14FX 50  
#10  
#10  
1
⁄"  
U.L. Listed E9809  
Installing tools: WT145C, WT2000, WT112M, ERG2001, ERG2003, WT2130A (RC)  
Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications (i.e.  
12050 tool and application dies).  
Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.)  
96  
Telecom 1-800-685-9452  
Fork Terminals  
®
®
Non-Insulated Fork  
Wt./Lbs.  
Per  
1000  
Dimensions  
Cat.  
No.  
Pkg.  
Qty.  
Wire  
Range  
Bolt  
Hole  
A
B
C
M
A18-6F  
A116  
100  
1000  
100  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
#6  
#6  
4
4
4
4
4
4
.72  
.72  
.75  
.75  
.75  
.75  
.25  
.25  
.31  
.31  
.31  
.31  
.27  
.27  
.27  
.27  
.27  
.27  
.59  
.59  
.59  
.59  
.59  
.59  
A18-8F  
A114  
#8  
1000  
100  
#8  
#10  
#10  
A18-10F  
A115  
1000  
These non-insulated fork terminals are made of  
electrolytic copper for high conductivity. They  
can be installed with crimping tools having a  
single indentor or double indentor (recom-  
mended for solid wire). Serrated barrel  
B14-6F  
B64  
100  
1000  
1000  
100  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
#6  
#6  
6
6
6
6
6
6
6
6
.75  
.75  
.66  
.75  
.75  
.75  
.75  
.90  
.31  
.31  
.25  
.31  
.31  
.31  
.31  
.44  
.27  
.27  
.13  
.27  
.27  
.27  
.27  
.38  
.59  
.59  
.50  
.59  
.59  
.59  
.59  
.68  
B19†  
#6  
B14-8F  
B65  
#8  
1000  
100  
#8  
increase grip on wire. Wire range identification  
is stamped on the tongue of each terminal.  
B14-10F  
B115  
#10  
1000  
100  
#10  
1
B14-14F  
⁄"  
Catalog numbers with the suffix S indicate a  
flanged-tongue fork with turned-up tips for  
extra holding protection in the event the mount-  
ing screw loosens.  
C10-6F  
C133  
C10-8F  
C114  
C10-10F  
C115  
C10-14F  
C116  
50  
500  
50  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
#6  
#6  
7
7
7
7
7
7
7
7
.77  
.77  
.31  
.31  
.38  
.38  
.38  
.38  
.50  
.50  
.27  
.27  
.27  
.27  
.27  
.27  
.37  
.37  
.63  
.63  
.63  
.63  
.63  
.63  
.73  
.90  
#10  
#10  
#10  
.82  
500  
50  
.82  
.82  
Stock thickness same as ring terminal of same  
500  
50  
#10  
.82  
1
"
.98  
1
50  
"
1.15  
U.L. Listed E9809  
Installing tools: WT111C, WT112M, WT110M, WT2000, ERG2002, ERG2003, WT1300,  
WT3155A  
Turned-up toes  
turned up toes  
size.  
Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications (i.e.  
12050 tool and application dies).  
Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.)  
97  
Telecom 1-800-685-9452  
Locking Fork Terminals  
Locking fork terminals have a spe-  
cially designed tongue that lets  
them go on like a fork and stay on  
like a ring.  
®
®
Nylon Insulated Locking Fork—Insulation Grip  
Wt./Lbs.  
Dimensions  
Cat.  
No.  
Pkg.  
Qty.  
Wire  
Range  
Max.  
Ins.  
Bolt  
Per  
Hole 1000  
A
B
C
M
RA18-6FL  
RA2213  
100  
1000  
100  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
.136  
.136  
.136  
.136  
.136  
.136  
#6  
#6  
5
5
5
5
5
5
.86  
.86  
.86  
.86  
.86  
.86  
.25  
.25  
.29  
.29  
.29  
.29  
.25  
.25  
.25  
.25  
.25  
.25  
.71  
.71  
.71  
.71  
.71  
.71  
RA18-8FL  
RA2243  
#8  
1000  
100  
#8  
#10  
#10  
RA18-10FL  
RA2253  
1000  
RB14-6FL  
RB2213  
100  
1000  
1000  
100  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
.162  
.162  
.190  
.162  
.162  
.162  
.162  
.190  
#6  
#6  
6
6
6
6
6
6
6
6
.87  
.87  
.95  
.87  
.87  
.87  
.87  
.95  
.25  
.25  
.25  
.29  
.29  
.29  
.29  
.29  
.25  
.25  
.25  
.25  
.25  
.25  
.25  
.25  
.71  
.71  
.79  
.71  
.71  
.71  
.71  
.71  
RB2214  
#6  
Stock thickness same as ring terminal of same  
size.  
RB14-8FL  
RB2233  
#8  
#8  
#10  
#10  
#10  
1000  
100  
RB14-10FL  
RB2253  
1000  
1000  
RB2254  
RC10-6FL  
RC2203  
50  
500  
1000  
50  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
.210  
.210  
.250  
.210  
.210  
.210  
.210  
.250  
.210  
.210  
#6  
#6  
8
8
8
8
8
8
8
.97  
.97  
.31  
.31  
.31  
.37  
.37  
.37  
.37  
.37  
.50  
.50  
.27  
.27  
.27  
.27  
.27  
.27  
.27  
.27  
.32  
.32  
.81  
.81  
.91  
.81  
.81  
.81  
.81  
.91  
.86  
.86  
RC2204  
#6  
1.07  
1.00  
1.00  
1.00  
1.00  
1.10  
1.12  
1.12  
RC10-8FL  
RC2213  
#8  
#8  
500  
50  
RC10-10FL  
RC2223  
#10  
#10  
500  
1000  
50  
RC2224  
#10  
1
RC10-14FL  
RC2233  
"
8
8
1
500  
⁄"  
U.L. Listed E9809  
U.S. Pat. 3,590,387  
Installing tools: ERG-2001, ERG-2003, WT145C, WT2000, WT112M, WT145A,  
WT2130A (RC)  
Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications (i.e.  
12050 tool and application dies).  
Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.)  
98  
Telecom 1-800-685-9452  
Locking Fork Terminals  
®
®
Vinyl Insulated Locking Fork—Insulation Support  
Wt./Lbs.  
Bolt Per  
Hole 1000  
Dimensions  
Cat.  
No.  
Pkg.  
Qty.  
Wire  
Range  
Max.  
Ins.  
A
B
C
M
18RA-6FL  
RA2217  
100  
1000  
1000  
100  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
.150  
.150  
.155  
.150  
.150  
.150  
.150  
#6  
#6  
5
5
5
5
5
5
5
.97  
.97  
.97  
.97  
.97  
.97  
.97  
.25  
.25  
.29  
.29  
.29  
.29  
.29  
.25  
.25  
.25  
.25  
.25  
.25  
.81  
.81  
.81  
.81  
.81  
.81  
.81  
RA2227  
#6  
18RA-8FL  
RA2247  
18RA-10FL  
RA2257  
#8  
#8  
#10  
#10  
1000  
100  
1000  
Stock thickness same as ring terminal of same  
size.  
14RB-6FL  
RB2207  
100  
1000  
1000  
100  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
.170  
.170  
.170  
.170  
.170  
.170  
.170  
#6  
#6  
6
6
6
6
6
6
6
.97  
.97  
.97  
.97  
.97  
.97  
.97  
.25  
.25  
.29  
.29  
.29  
.29  
.29  
.27  
.27  
.27  
.27  
.27  
.27  
.27  
.81  
.81  
.81  
.81  
.81  
.81  
.81  
RB2217  
#6  
14RB-8FL  
RB2237  
14RB-10FL  
RB2257  
#8  
#8  
#10  
#10  
1000  
100  
1000  
10RC-6FL  
RC2207  
50  
500  
50  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
.220  
.220  
.220  
.220  
.220  
.220  
.220  
.220  
#6  
#6  
8
8
8
8
8
8
8
8
1.09  
1.09  
1.09  
1.09  
1.09  
1.09  
1.09  
1.09  
.31  
.31  
.37  
.37  
.37  
.37  
.49  
.49  
.27  
.27  
.27  
.27  
.27  
.27  
.27  
.27  
.90  
.90  
.90  
.90  
.90  
.90  
.90  
.90  
10RC-8FL  
RC2217  
#8  
500  
50  
#8  
10RC-10FL  
RC2227  
10RC-14FL  
RC2237  
#10  
500  
50  
500  
#10  
1
"
1
⁄"  
U.L. Listed E9809  
U.S. Pat. 3,590,387  
Installing tools: ERG-2001, ERG-2003, WT145C, WT2000, WT112M  
Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications (i.e.  
12050 tool and application dies).  
Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.)  
99  
Telecom 1-800-685-9452  
Locking Fork Terminals  
®
®
Vinyl Insulated Locking Fork—Expanded Insulation Support  
Wt./Lbs.  
Dimensions  
Cat.  
No.  
Pkg.  
Qty.  
Wire  
Range  
Max.  
Ins.  
Bolt  
Per  
Hole 1000  
A
B
C
M
18RA-6FLX 100  
18RA-8FLX 100  
18RA-10FLX 100  
RA2257-170 1000  
22-16  
22-16  
22-16  
22-16  
.170  
.170  
.170  
.170  
#6  
#8  
#10  
#10  
5
5
5
5
.97  
.97  
.97  
.97  
.25  
.29  
.29  
.29  
.25  
.25  
.25  
.25  
.81  
.81  
.81  
.81  
14RB-6FLX 100  
RB2207-200 1000  
RB2217-200 1000  
14RB-8FLX 100  
RB2237-200 1000  
14RB-10FLX 100  
RB2257-200 1000  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
.200  
.200  
.200  
.200  
.200  
.200  
.200  
#6  
#6  
6
6
6
6
6
6
6
.97  
.97  
.97  
.97  
.97  
.97  
.97  
.31  
.31  
.29  
.31  
.31  
.31  
.31  
.27  
.27  
.27  
.27  
.27  
.27  
.27  
.81  
.81  
.81  
.81  
.81  
.81  
.81  
Stock thickness same as ring terminal of same  
size.  
#6  
#8  
#8  
#10  
#10  
10RC-6FLX  
50  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
.250  
.250  
.250  
.250  
.250  
.250  
#6  
#6  
8
8
8
8
8
8
1.07  
1.07  
1.10  
1.10  
1.10  
1.22  
.31  
.31  
.37  
.37  
.37  
.50  
.27  
.27  
.27  
.27  
.27  
.32  
.91  
.91  
.91  
.91  
.91  
.96  
RC2207-250 500  
10RC-8FLX  
50  
50  
#8  
10RC-10FLX  
#10  
RC2227-250 500  
#10  
1
10RC-14FLX  
50  
⁄"  
U.L. Listed E9809  
U.S. Pat. 3,590,387  
Installing tools: ERG-2001, ERG-2003, WT145C, WT2000, WT112M  
Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications (i.e.  
12050 tool and application dies).  
Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.)  
Heat Shrinkable Locking Fork Terminals—  
Expanded Insulation Support  
®
®
Wt./Lbs.  
Dimensions  
Cat.  
No.  
Pkg.  
Qty.  
Wire  
Range  
Max.  
Ins.  
Bolt  
Hole  
Per  
1000  
A
B
RAS18-6FLX  
RAS18-8FLX  
RAS18-10FLX  
100  
100  
100  
22-18  
22-18  
22-18  
.170  
.170  
.170  
#6  
#8  
#10  
5
5
5
1.350  
1.350  
1.350  
.25  
.29  
.29  
RBS14-6FLX  
RBS14-8FLX  
RBS14-10FLX  
100  
100  
100  
16-14  
16-14  
16-14  
.200  
.200  
.200  
#6  
#8  
#10  
6
6
6
1.350  
1.350  
1.350  
.25  
.29  
.29  
RCS10-6FLX  
RCS10-8FLX  
RCS10-10FLX  
RCS10-14FLX  
50  
50  
50  
50  
12-10  
12-10  
12-10  
12-10  
.250  
.250  
.250  
.250  
#6  
#8  
8
8
8
8
1.350  
1.350  
1.350  
1.350  
.31  
.37  
.37  
.49  
#10  
1
⁄"  
U.L. Listed E9809  
Installing tool: WT1255  
Note: Heat Shrinkable terminals not available on Mylar Tape.  
100  
Telecom 1-800-685-9452  
Locking Fork Terminals  
®
®
Non-Insulated Locking Fork  
Wt./Lbs.  
Dimensions  
Cat.  
No.  
Pkg.  
Qty.  
Wire  
Range  
Bolt  
Hole  
Per  
1000  
A
B
C
M
A18-6FL  
A221  
100  
1000  
100  
22-16  
22-16  
22-16  
22-16  
22-16  
22-16  
#6  
#6  
43⁄  
43⁄  
43⁄  
43⁄  
43⁄  
43⁄  
4
.75  
.75  
.75  
.75  
.75  
.75  
.25  
.25  
.29  
.29  
.29  
.29  
.27  
.27  
.27  
.27  
.27  
.27  
.59  
.59  
.59  
.59  
.59  
.59  
4
A18-8FL  
A224  
#8  
4
1000  
100  
#8  
#10  
#10  
4
A18-10FL  
A225  
4
1000  
4
B14-6FL  
B220  
100  
1000  
100  
18-14  
18-14  
18-14  
18-14  
18-14  
18-14  
#6  
#6  
43⁄  
43⁄  
43⁄  
43⁄  
43⁄  
43⁄  
4
.75  
.75  
.75  
.75  
.75  
.75  
.25  
.25  
.29  
.29  
.29  
.29  
.27  
.27  
.27  
.27  
.27  
.27  
.59  
.59  
.59  
.59  
.59  
.59  
4
Stock thickness same as ring terminal of same  
size.  
B14-8FL  
B223  
#8  
4
1000  
100  
#8  
#10  
#10  
4
B14-10FL  
B225  
4
1000  
4
C10-6FL  
C220  
50  
500  
50  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
12-10  
#6  
#6  
73⁄  
73⁄  
73⁄  
73⁄  
73⁄  
73⁄  
73⁄  
4
.85  
.85  
.85  
.85  
.85  
.85  
.85  
.31  
.31  
.37  
.37  
.37  
.37  
.49  
.27  
.27  
.27  
.27  
.27  
.27  
.27  
.66  
.66  
.66  
.66  
.66  
.66  
.66  
4
C10-8FL  
C221  
#8  
4
500  
50  
#8  
4
C10-10FL  
C222-TB  
C10-14FL  
#10  
4
500  
50  
#10  
4
1
⁄"  
4
U.L. Listed E9809  
U.S. Pat. 3,590,387  
Installing tools: WT110M, WT111M, WT112M, WT2000, ERG-2002, WT1300,  
WT3155A (B&C)  
Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications  
(i.e. 12050 tool and application dies).  
Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.)  
101  
Telecom 1-800-685-9452  
Heat Shrinkable Terminal, Splices, Disconnects  
Heat Shrinkable  
These ring terminals, butt splices  
and disconnects are self-insulated  
with heat shrinkable nylon and  
internally coated sealant. Upon  
completed installation, a fully  
sealed connection is achieved to  
protect the joint against the  
degrading effects of galvanic  
action, corrosion, and environmen-  
®
®
Heat Shrinkable-Ring Terminals—Expanded Insulation Support  
Wt./Lbs.  
Cat.  
No.  
Pkg.  
Qty.  
Wire  
Range  
Max.  
Ins.  
Bolt  
Hole  
Per  
1000  
RAS18-6X  
RAS18-8X  
RAS18-10X  
100  
100  
100  
22-18  
22-18  
22-18  
.170  
.170  
.170  
#6  
#8  
#10  
2
3
2
RBS14-6X  
RBS14-8X  
RBS14-10X  
100  
100  
100  
16-14  
16-14  
16-14  
.200  
.200  
.200  
#6  
#8  
#10  
3
3
3
RCS10-6X  
RCS10-8X  
RCS10-10X  
RCS10-14X  
50  
50  
50  
50  
12-10  
12-10  
12-10  
12-10  
.250  
.250  
.250  
.250  
#6  
#8  
3
5
5
6
#10  
1
⁄"  
Installing tool: WT1255  
See previous pages for dimensional information.  
Heat Shrinkable-Locking Fork Terminals—  
Expanded Insulation Support  
®
®
Wt./Lbs.  
Per  
1000  
Cat.  
No.  
Pkg.  
Qty.  
Wire  
Range  
Max.  
Ins.  
Bolt  
Hole  
RAS18-6FLX  
RAS18-8FLX  
RAS18-10FLX  
100  
100  
100  
22-18  
22-18  
22-18  
.170  
.170  
.170  
#6  
#8  
#10  
5
5
5
RBS14-6FLX  
RBS14-8FLX  
RBS14-10FLX  
100  
100  
100  
16-14  
16-14  
16-14  
.200  
.200  
.200  
#6  
#8  
#10  
6
6
6
RCS10-6FLX  
RCS10-8FLX  
RCS10-10FLX  
RCS10-14FLX  
50  
50  
50  
50  
12-10  
12-10  
12-10  
12-10  
.250  
.250  
.250  
.250  
#6  
#8  
8
8
8
8
#10  
1
⁄"  
Installing tool: WT1255  
Note: Not available on Mylar Tape.  
102  
Telecom 1-800-685-9452  

相关型号:

A18-4

CRIMP TERM RING 6BA Inhalt pro Packung: 100 Stk.
ETC

A18-6

CRIMP TERM RING 4BA Inhalt pro Packung: 100 Stk.
ETC

A18-6FL

CRIMP TERM FORK 4BA Inhalt pro Packung: 100 Stk.
ETC

A180

SILICON RECTIFIER
POWEREX

A180

Cascadable Amplifier 10 to 500 MHz
TE

A1801

BROADBAND: RF & WIRELESS
PULSE

A1805

AC Film Capacitors Lighting
EPCOS

A1805S-2W,A1809S-2W,A1812S-2W,A1815S-2W

产品特点 环保设计,符合ROHS指令 通过CE认证 工业级产品,工作温度:-40℃~+85℃ 输出额定功率:2W 定电压输入(5V、12V、24V) 非稳压输出( ±3.3V、±5V、±9V、±12V、±24V) 隔离电压≥1000VDC 性能稳定,可靠性高(MTBF≥100万小时) 国际标准引脚,SIP封装
MICRODC

A1806UC4AP

SIDACtor devices
TECCOR

A1806UC4RP

SIDACtor devices
TECCOR

A1806UC4TP

SIDACtor devices
TECCOR

A180A

Rectifier Diode, 1 Phase, 1 Element, 150A, 100V V(RRM), Silicon, R50, 1 PIN
POWEREX