A3PJ-5013 [ETC]
SPLIT SCREEN VERTICAL ; SPLIT屏竖\n型号: | A3PJ-5013 |
厂家: | ETC |
描述: | SPLIT SCREEN VERTICAL
|
文件: | 总13页 (文件大小:974K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Back
Lighted Pushbutton Switch
A3PJ
Rectangular Type with
18.9 mm × 26.1 mm Button
Back-projected LED offers longer life, wider
viewing, and greater viewing distance
Replaceable LED T-1-3/4 standardized for ease of
maintenance
Two choices of contacts to match load require-
ments: silver and gold
Snap-action offers high reliability
Lamped type also available
Button lockable
LED protected by a current-limiting resistor
Ordering Information
Individually order indicators and switch units.
LED-lighted Type
Indicator Unit*
Switch Unit**
Pushbutton Switch
A3Pj-5jjj-jjE
Indicator
Pushbutton Switch
A3Pj-7jjj-j
Indicator
M2Pj-5jjj-jjE
M2Pj-7jjj-j
* The LED-lighted type has a built-in LED chip (which lights either in color or white).
**The switch unit can be used with both the LED and incandescent lamp.
LED Ball-lighted Type
Indicator Unit
LED
Switch Unit*
DC-operated
Pushbutton Switch
A3PJ-7jjj-j
Indicator
SLL-jjEj
Pushbutton Switch
A3PJ-502j
Indicator
AC-/DC-operated
SLL-jjEACj
M2PJ-7jjj-j
* The Switch unit can be used with either the LED-lighted type, LED ball-lighted type, or incandescent lamp-lighted type pushbutton unit
1
A3PJ
A3PJ
Incandescent Lamp-lighted Type
Indicator Unit
Switch Unit*
Incandescent Lamp
Pushbutton Switch
A3PJ-501j
Indicator
Standard
Pushbutton Switch
A3PJ-7jjj-j
Indicator
SLL-jj
Power-saving
SLL-jjH
M2PJ-501j
M2PJ-7jjj-j
* The Switch unit can be used with either the LED-lighted type, LED ball-lighted type, or incandescent lamp-lighted type
pushbutton unit.
LED-lighted Type
Switch Units
Function
Contact & output form
Momentary action
A3PJ-7010-1
A3PJ-7030-1
A3PJ-7050-1
A3PJ-7070-1
Alternate action
A3PJ-7020-1
A3PJ-7040-1
A3PJ-7060-1
A3PJ-7080-1
Switch indication unit
(switching and indicating
functions)
Silver alloy contact
SPDT
DPDT
SPDT
DPDT
Gold alloy contact
Indicator unit (indicating function only)
M2PJ-7010-1
Note: The switch unit is supplied with a black flange and a spring mounting clip.
2
A3PJ
A3PJ
Display Screen Units (Transmitted Color)
Screen pattern & color
For switch indicator
unit
For indicator unit
Single screen type
(solid color)
White
Red
Green
Orange
White
Red
Green
Orange
White
Red
Green
Orange
White
Red
Green
Orange
A3PJ-5701-
A3PJ-5702-
A3PJ-5703-
A3PJ-5706-
A3PJ-5711-
A3PJ-5712-
A3PJ-5713-
A3PJ-5716-
A3PJ-5721-
A3PJ-5722-
A3PJ-5723-
A3PJ-5726-
A3PJ-5731-
A3PJ-5732-
A3PJ-5733-
A3PJ-5736-
E
E
E
E
M2PJ-5701-
M2PJ-5702-
M2PJ-5703-
M2PJ-5706-
M2PJ-5711-
M2PJ-5712-
M2PJ-5713-
M2PJ-5716-
M2PJ-5721-
M2PJ-5722-
M2PJ-5723-
M2PJ-5726-
M2PJ-5731-
M2PJ-5732-
M2PJ-5733-
M2PJ-5736-
E
E
E
E
jj
jj
jj
jj
jj
jj
jj
jj
2-split screen type
(Horizontal)
jj
jj
jj
jj
jj
jj
jj
jj
jj
jj
jj
jj
E
jj
jj
jj
jj
jj
jj
jj
jj
jj
jj
jj
jj
E
White
Red
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
Green
2-split screen type
(Vertical)
Refer to the LED ball type
White
Red
Green
3-split screen type
(Horizontal)
a
c
b
3-split screen type
(Vertical)
a
b
c
4-split screen type
d
c
a
b
Note: 1. The display screen unit incorporates a lens, a transparent legend plate, a plunger, a coloredplate andLED(s). Thesplit screentype
includes a light baffle in addition to the above items.
2. When placing your order for the display screen unit, fill one of the following rated voltage codes in jjof the part number.
Rated voltage
5 VDC:
Voltage code
05
12
24
12 VDC:
24 VDC:
3. Whenplacingyour orderfor thelamp typelighted pushbuttonswitch, referto the‘‘Ordering Information-Lamptypes” sectionbelow.
4. When requiring a projected color type, refer to the LED ball type which is supplied with four color plates (white, red, green, and
orange).
3
A3PJ
A3PJ
When placing your order for the lamp type and LED ball type A3PJ, specify the required numbers of the switch units, display screen units, and
lamps or LEDs, according to the following tables.
Lamp types
Switch Units
Function
Construction
Momentary action
Alternate action
A3PJ-7020-1
A3PJ-7040-1
A3PJ-7060-1
A3PJ-7080-1
Contact & output form
Switch indication unit
(switching and indicating
functions)
Silver alloy contact
SPDT
DPDT
SPDT
DPDT
A3PJ-7010-1
A3PJ-7030-1
A3PJ-7050-1
A3PJ-7070-1
M2PJ-7010-1
Gold alloy contact
Indicator unit (indicating function only)
Note: The switch unit is supplied with a black flange and a spring mounting clip.
Display Screen Units
Screen pattern
Lamps (Standard)
Operating
For
switch-indicator
unit
For indicator unit
Rated
Rated
Model
SLL-06
SLL-14
SLL-28
voltage
voltage
current
5 V
6 V
200 mA
80 mA
40 mA
Single screen
A3PJ-5011
A3PJ-5012
A3PJ-5013
A3PJ-5014
A3PJ-5015
A3PJ-5016
M2PJ-5011
M2PJ-5012
M2PJ-5013
M2PJ-5014
M2PJ-5015
M2PJ-5016
12 V
24 V
14 V
28 V
2-split screen
(Horizontal)
2-split scree
(Vertical)
3-split screen
(Horizontal)
3-split screen
(Vertical)
Lamps (Microload)
Operating
voltage
Rated
voltage
Rated
current
100 mA
40 mA
25 mA
Model
5 V
12 V
24 V
6 V
14 V
28 V
SLL-06H
SLL-14H
SLL-28H
4-split screen
Note: 1. Commercially available 1 W lamps can also be used,
provided the base socket conforms to T-13/4 sizing. For
single screen and 2-split screen types, 2 lamps will be
used. However, forthe 3-split and 4-split screen types, 4
specialOmronlamps(listedunderMicroloadabove)are
required to reduce current draw, and heat output.
Note: The display screen unit consists of a lens, a legend plate, a
plunger, a lamp holder, 5 colored plates (white, red, green,
blue, and yellow) and light baffle (for other than the single
screen type).
2. Note that application of 80% of the rated voltage to the
lamp is advantageous in terms of service life and heat
generation.
3. When a dark current is to be conducted through the
lamps to suppress inrush current, allow 20 to 30% of the
rated current to flow.
Number of Necessary Incandescent Lamps
Model
A3PJ
M2PJ
Split
Non-split
2-split
(Horizontal)
Lamp
Standard
Power-saving
No. of lamps
2
4
2-split
(Vertical)
3-split
4-split
LED-ball Type
Switch Units
Function
Construction
Contact & output form
Momentary action
Alternate action
Switch indication unit
(switching and indicating
functions)
Silver alloy contact
SPDT
A3PJ-7010-1
A3PJ-7030-1
A3PJ-7050-1
A3PJ-7070-1
M2PJ-7010-1
A3PJ-7020-1
A3PJ-7040-1
A3PJ-7060-1
A3PJ-7080-1
DPDT
SPDT
DPDT
Gold alloy contact
Indicator unit (indicating function only)
Note: The switch unit is supplied with a black flange and a spring mounting clip.
4
A3PJ
A3PJ
Display Screen Unit (LED ball is Not Built-in.)
Split
Screen pattern
Pushbutton unit
A3PJ-5021
Indicator
Non-split
M2PJ-5021
M2PJ-5022
M2PJ-5023
M2PJ-5024
M2PJ-5025
M2PJ-5026
2-split (Horizontal)
2-split (Vertical)
3-split (Horizontal)
3-split (Vertical)
4-split
A3PJ-5022
A3PJ-5023
A3PJ-5024
A3PJ-5025
A3PJ-5026
LED Ball Ratings
Color
White
Red
Yellow
Green
Applicable lens color
Operating voltage
White
Red
Yellow
Green
5 VDC
12 VDC
24 VDC
SLL-05EW
SLL-12EW
SLL-24EW
SLL-05ER
SLL-12ER
SLL-24ER
SLL-05EY
SLL-12EY
SLL-24EY
SLL-05EG
SLL-12EG
SLL-24EG
Note: The white LEDs are applicable to projected color.
LED Ball Ratings
Number of Necessary LED Balls
Rated voltage
current (mA)
30 mA
30 mA
15 mA
12.5 mA
Operating
Model
A3PJ
Split
Non-split
2-, 3-, 4-split
Lamp
LED ball
No. of lamps
4
4
voltage range
5 VDC
6 VDC
12 VDC
24 VDC
5 VDCr5%
6 VDCr5%
12 VDCr5%
24 VDCr5%
M2PJ
Specifications
Ratings
Silver Alloy Contacts (for Power Loads)
Non-inductive load (A)
Resistive load Lamp load
NC NO
Inductive load (A)
Inductive load
NC NO
Rated
voltage (V)
Motor load
NC
NO
NC
NO
125 VAC
250 VAC
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
5
3
5
5
4
0.4
0.2
0.7
0.5
2
2
2
3
2
4
4
3
1.3
0.8
3
3
3
0.05
0.03
0.4
0.2
0.05
0.03
Note: 1. Inductive load: power factor = 0.4; time constant: 7 ms
2. Lamp load has an inrush current of 10 times the steady-state current.
Motor load has an inrush current of 6 times the steady-state current.
Gold Alloy Contacts (for Very Small Loads)
LED Chip Ratings
Switching capacity
0.1 A, 30 VDC/125 VAC (re-
sistive load)
current (mA)
Rated voltage
Operating
voltage
range
Single
screen type
2-split
screen type
5 VDC
12 VDC
24 VDC
80
40
20
40×2
20×2
13×2
5 Vr5%
12 Vr5%
24 Vr5%
5
A3PJ
A3PJ
Characteristics
Operating frequency
Mechanical: 120 operations/minute max.
Electrical: 30 operations/minute max.
Operating force
Momentary action: 600 g max.
Alternate action: 700 g max.
Insulation resistance
Dielectric strength
100 M: min. (at 500 VDC)
1,000 VAC, 50/60 Hz for 1 minute between terminals of same polarity
2,000 VAC, 50/60 Hz for 1 minute between terminals of different polarity, between
current-carrying metal part and ground, and between each terminal and non-current-carrying
metal part
Vibration
Shock
Malfunction durability: 10 to 55 Hz, 1.5 mm double amplitude
Mechanical durability: 200 m/s (20 G)
2
Ambient temperature
Humidity
Operating: --10qC to 40qC
35 to 85% RH max.
Life expectancy
Mechanical:
Momentary-action type: 1,000,000 operations min.
Alternate-action type: 200,000 operations min.
Electrical action type: 100,000 operations min.
(see note below.)
Weight
Approx. 20 g to 24.5 g
Note: With the alternate action type, one operation cycle consists of set and reset actions.
Approved by Standards
UL (File No. E41515)
CSA (File No. LR45258)
Silver contact type: 5 A, 125 VAC
3 A, 250VAC
Gold alloy contact type: 0.1 A, 30 VDC
0.1 A, 125 VAC
6
A3PJ
A3PJ
Dimensions
Unless otherwise specified, a tolerance of r0.4 mm applies to all dimensions.
A3PJ (M2PJ)
A3PJ (M2PJ) with Seal Cover
9.3
Note: When the seal cover is employed, neither barrier
nor switch guard can be attached to the switch unit.
A3PJ with Switch Guard
Socket (See Accessories.)
PCB Terminal Dimensions
Bottom view
Panel cutout*
52.6
Mounting Holes (Bottom View)
* When the flange mount type switches are arranged in the vertical multiple
mounting style, no switch guard can be used.
When a switch guard is employed, no seal cover can be attached to the
switch unit.
7
A3PJ
A3PJ
Panel Cutout
Classification
Mounting design
Panel cutout
Remarks
Flange
mount type
Individual
mounting
(Horizontal)
Panel cutout spacing between
rows of units
Flange
mount type
Multiple
mounting
(Horizontal)
Panel cutout spacing between
rows of units
Individual
mounting
(Vertical)
Multiple
mounting
(Vertical)
Barrier
mount type
Individual
mounting
(Horizontal)
Panel cutout spacing between
rows of units
Multiple
mounting
(Horizontal)
Individual
mounting
(Vertical)
Dotted line indicates the posi-
tion of each mounting barrier.
Multiple
mounting
(Vertical)
Note: 1. n: Number of units.
2. Recommended panel thickness: 1 to 5 mm
Terminals/Connections
A3PJ-7030-1, A3PJ-7040-1,
A3PJ-7070-1, A3PJ-7080-1
A3PJ-7010-1, A3PJ-7020-1,
A3PJ-7050-1, A3PJ-7060-1
M2PJ-7010-1
(Bottom view)
(Bottom view)
(Bottom view)
ꢀ With the single screen type, connect an LED across terminals LC and L2.
8
A3PJ
A3PJ
Assembly/Disassembly
1. Locking/Unlocking Positive Lens Lock Mechanism
5. Mounting Colored Plate
After mounting the light baffle, place the colored plate on the
plunger case with the dull side of the colored plate faced
downward. Besurethat the projectionon theupper surfaceof
the colored plate faces outward.
2. Mounting Display Screen Unit
With the OMRON logo on the switch unit faced upward, and
the LED contact piece of the display screen unit positioned
upward, align the split on each side of the display screen unit
with the projections inside the switch unit, and push the dis-
play screen unit into the switch unit.
6. Mounting Switch Onto Panel
x Individual Mounting
When the mounting switch unit, push the switch unit into the
panel cutout from front of the mounting panel by holding the
switch unit with the logo mark ‘‘OMRON” faced downward.
Since the mounting panel has some elasticity, the switch unit
snaps into the panel with only a single push.
3. Removing/Mounting Lens
x Multiple Mounting
When mounting a number of switch units in line on the panel,
usethemountingbarriers atbothendsof thepanel cutoutand
insert the spacing barrier in between the two switch units.
Push all the connected switch units together into the panel
cutout while holding the mounting barriers at both ends.
4. Mounting Light Baffle (Split Screen Type Only)
While holding the plunger case of the display screen unit, in-
sert the light baffle into the interior groove of the plunger case
from above.
9
A3PJ
A3PJ
7. Mounting Flange, Barriers and Replacing Spring
9. Fail-safe Relamping Function
Mounting Clip
x Insert the assembles display screen unit into the switch unit
Mount each part by pushing it in the direction of the arrow
shown in the corresponding illustration below.
while pushing the center of the lens.
x After the display screen unit is released, the fail-safe
relamping mechanism is unlocked.
x Replacing Spring Mounting Clip
x The switch will operate normally.
8. Mounting Seal Cover
After mounting the seal cover onto the flange of the switch
unit, push the switch unit into the panel cutout.
10
A3PJ
A3PJ
Construction
ꢀ With the LED type, an LED is incorporated in the plunger case.
With the lamp type, the lamp holder and plunger case are inde-
pendent units. Insert a T-3/4 lamp in this holder.
11
A3PJ
A3PJ
Accessories (Order Separately)
Name
Appearance
Classification
For A3PA
Remarks
Flange
Flange color
A black flange is provided to
the switch unit having the suf-
fix ‘‘-1” in its model number.
To the switch unit having the
suffix ‘‘-2”, a light gray flange
is provided.
Black
A3PJ-2001
Light gray
A3PJ-2002
A3PJ-2003
A3PJ-4101
A3PJ-4102
A3PJ-4103
A3PJ-4001
White
Socket
Barrier
Cannot be used with the sol-
id-state output type.
Wire-wrap terminal
PCB terminal
Cannot be used with 3-pole
type.
Solder terminal
Short-edge barrier
To prevent malfunctioning and
to improve design image of
the mounting panel.
Black
Light gray
Black
A3PJ-4002
A3PJ-4004
A3PJ-4005
A3PJ-4007
A3PJ-4008
A3PJ4010
A3PJ-4011
A3PJ-5050
Long-edge barrier
Light gray
Black
Intermediate short bar-
rier
Light gray
Black
Intermediate long barri-
er
Light gray
Switch
Guard
Can be used by exchanging
with the lens.
For horizontal mounting (with OMRON logo fac-
ing down)
Cannot be used with seal
cover.
For vertical mounting (with OMRON logo facing
to the right)
A3PJ-5055
Seal Cov-
er
---
A3PJ-5060 Cannot be used with barrier
and/or switch guard.
Legend
Plate
Transparent legend plate is
supplied with standard LED
indicator unit.
Transparent legend plate
Milk-white legend plate
A3PJ-5202
A3PJ-5201
Character
Plate
(Charac-
ter Film)
1 sheet (for 20 switch
units)
Words printed are ‘‘ON”,
‘‘OFF”, ‘‘START”, ‘‘STOP”,
‘‘RESET”, ‘‘COOL”, and ‘‘MO-
TOR”. Other characters can
be printed by request.
Character printed
A3PJ-5205
A3PJ-5207
Non-printed (transpar-
ent film)
1 sheet (for 1 switch
unit)
Character printed
Non-printed
A3PJ-5206
A3PJ-5208
Long
---
---
A3PJ-3002 Use when vertically mounting
single (with barrier) or multi-
ple switch units (in standard
mounting style and with barri-
er). Since a short mounting
plate is attached to the switch
unit, replace it with the long
one.
Mounting
Plate
Puller
A3PJ-5080 ---
12
A3PJ
A3PJ
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. A21-E1-5
13
相关型号:
A3PJ-5080
The Following Pages Provide Information Common To Each Model of The A22/M22 Pushbutton Switch
OMRON
A3PJ-90A11-05EG
Pushbutton Switch, SPDT, Momentary, Quick Connect/solder Terminal, Panel Mount
OMRON
A3PJ-90A11-05ER
Pushbutton Switch, SPDT, Momentary, 3A, 30VDC, Quick Connect/solder Terminal, Panel Mount
OMRON
©2020 ICPDF网 联系我们和版权申明