AP-30712B3-301V [ETC]
Converter ; 变流器\n型号: | AP-30712B3-301V |
厂家: | ETC |
描述: | Converter
|
文件: | 总4页 (文件大小:81K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
AP-30711/12
SYNCHRO/RESOLVER ANGLE POSITION INDICATOR
DESCRIPTION
FEATURES
The AP-30711 and the AP-30712 are ideal for automatic test, panel mount
both high resolution, dual input, syn- applications. The bench top AP-
chro/resolver angle position indica- 30712 has input terminals and con-
tors. These units convert analog syn- trols on the front panel, and is avail-
chro or resolver position information able with an optional IEEE-488 or
into a digital word. The digital word is MATE/CIIL interface in the rear.
used to display angular information
Transformer-Isolated
Synchro and Resolver
Inputs
•
•
Auto-Leveling of Any Input
Between 10 and 100 V L-L
APPLICATIONS
on the front panel of the unit. Each
unit’s standard display angular range
Resolution: 0.001°
•
•
Auto Phase Shift
Compensation
is decimal degrees from 0.000° to The AP-30711 and the AP-30712 can
359.999°. Bipolar ±179.995° is avail- be used wherever high accuracy syn-
able as a low-cost option. Both units chro or resolver angle information is
are available in two frequency ranges required for display, control, testing pur-
of 360 to 1200 Hz or 47 to 440 Hz. poses or computation. Applications
The digital word is also available for include development or production
use from the rear panel of both units testing of synchro/resolver based sys-
IEEE-488 or MATE/CIIL
Interface Option
•
through a parallel BCD interface.
tems, information translators in quali-
ty control systems, machine tool con-
The AP-30711’s small size and trols, motion feedback, and automatic
remote programming feature makes it test equipment.
1999 Data Device Corporation
©
AP-30711 AND AP-30712 SPECIFICATIONS
AP-30711 AND AP-30712 SPECIFICATIONS (con’t)
PARAMETER
UNIT
VALUE
PARAMETER
Digital Inputs
(TTL Compatible) Level
Logic “1”
UNIT
VALUE
Resolution
Standard
degrees
degrees
0.001
0.005
±179.995 Option
V
V
2.4 minimum
0.8 maximum
1 standard TTL
Logic “0”
Loading
Data Freeze
DF
Accuracy
Standard
±179.995 Option
degrees
degrees
±0.004
±0.010
(pin 42)
(pin 27)
(pin 43)
“1” Freeze, “0” or
Open-Track
“0” Freeze, “1” or
Open - Track
Angular Ranges
Standard
degrees
degrees
0° - 359.999°
±179.995°
DF
±179.995 Option
Channel Select
“0” CHAN 1
Display
Standard ±179 Option
“1” or open - CHAN 2
Number of digits
Size of digits
digits
inches
6 decimal
0.55
5½ decimal
0.55
Digital Outputs
Digital Output Data
Drive Capability
Reference Input
Voltage
6 decade BCD (1; 2; 4; 8 code)
10 TTL loads
IEEE-488 GPIB (optional)
+2.5 minimum
V rms
Hz
3 to 115
47 to 400, or
360 to 1200
Frequency
Logic “1”
Logic “0”
V
V
Impedance
Ohms
100k minimum
+0.6 maximum
Signal Input
Input Type
AP-30711
AP-30712
Converter Busy
TTL compatible pulses,
1 µs wide; transfer data
2 µs after trailing edge of pulse
synchro or resolver
Channel 1: synchro
Channel 2: resolver
10 to 100 (AGC)
47 to 440, or
360 to 1200
±30 maximum
1 Meg minimum
Power Input
Voltage
V rms
V rms
Hz
115 ±10%, or
230 ±10%
47 - 440
Voltage Levels
Frequency
V L-L
Hz
Hz
degrees
Ohms
Frequency
Power
VA
25 maximum
Allowable Phase Shift
Impedance
Temperature Range
Dynamic Characteristics
Tracking Rate
Operating
°C
0 - 70
0°-359.999° ±179.995°
47-440 Hz unit
360-1200 Hz unit
Settling Time
deg/sec
deg/sec
75
200
180
1000
Physical
Characteristics
Size
(for 180° step)
47-440 Hz unit
360-1200 Hz unit
AP-30711
inches
(cm)
inches
(cm)
1.75 x 9.50 x 12.50
(4.45 x 24.13 x 31.75)
3.50 x 9.50 x 12.50
(8.89 x 24.13 x 31.75)
sec max
sec max
3.0
1.5
1.5
0.4
AP-30712
Weight
AP-30711
AP-30712
lbs (kg)
lbs (kg)
6 (2.72)
8 (3.63)
2
ORDERING INFORMATION
AP-30711PX-301 X
Operating Voltage:
V = factory set for 230VAC line cord operation
Blank = factory set for 115VAC line cord operation
Frequency and Display Ranges:
1 = 360-1200 Hz, 0.000 Deg.
-359.999 Deg.
2 = 47-440 Hz, 0.000 Deg.
-359.999 Deg.
3 = 360-1200 Hz, ±179.995 Deg.
4 = 47-440 Hz, ±179.995 Deg.
AP-30712BX-30X X
Operating Voltage:
V = factory set for 230VAC line cord operation
Blank = factory set for 115VAC line cord operation
Interface:
1 = Parallel BCD
2 = IEEE 488 With Parallel BCD
3 = MATE/CIIL With Parallel BCD
Frequency And Display Range:
1 = 360-1200 Hz, 0.000 Deg.
-359.999 Deg.
2 = 47-440Hz, 0.000 Deg.
-359.999 Deg.
3 = 360-1200 Hz, ±179.995 Deg.
4 = 47-440Hz, ±179.995 Deg.
1.25
1.72
FRONT VIEW
8.81
9.50
7.94
.25 WIDE x .44
LONG OVAL
4 THRU HOLES
REAR VIEW
12.00
.125
.50
SIDE VIEW
2.98
3.50
FRONT VIEW
8.875
9.50
7.94
.25 WIDE x .44
LONG OVAL
4 THRU HOLES
ADDRESS
REAR VIEW
12.00
1.156
.50
SIDE VIEW
AP-30711/12 MECHANICAL OUTLINE
3
The information provided in this data sheet is believed to be accurate; however, no responsibility
is assumed by Data Device Corporation for its use, and no license or rights
are granted by implication or otherwise in connection therewith.
Specifications are subject to change without notice.
105 Wilbur Place, Bohemia, New York 11716-2482
For Technical Support - 1-800-DDC-5757 ext. 7389 or 7413
Headquarters - Tel: (631) 567-5600 ext. 7389 or 7413, Fax: (631) 567-7358
Southeast - Tel: (703) 450-7900, Fax: (703) 450-6610
West Coast - Tel: (714) 895-9777, Fax: (714) 895-4988
Europe - Tel: +44-(0)1635-811140, Fax: +44-(0)1635-32264
Asia/Pacific - Tel: +81-(0)3-3814-7688, Fax: +81-(0)3-3814-7689
World Wide Web - http://www.ddc-web.com
4
B-09/99-500
PRINTED IN THE U.S.A.
相关型号:
©2020 ICPDF网 联系我们和版权申明