Product data sheet  
Characteristics  
ATV312H018M2  
variable speed drive ATV312 - 0.18kW -  
0.6kVA - 24W - 200..240 V- 1-phase supply  
Main  
Range of product  
Altivar 312  
Product or component  
type  
Variable speed drive  
Product destination  
Asynchronous motors  
Simple machine  
Product specific  
application  
Assembly style  
Component name  
Motor power kW  
Motor power hp  
With heat sink  
ATV312  
0.18 kW  
0.25 hp  
[Us] rated supply  
voltage  
200...240 V (- 5...5 %)  
Supply frequency  
50...60 Hz (- 5...5 %)  
Single phase  
Network number of  
phases  
Line current  
3 A for 200 V, 1 kA  
2.5 A for 240 V  
EMC filter  
Integrated  
0.6 kVA  
Apparent power  
Maximum transient  
current  
2.3 A for 60 s  
Power dissipation in W  
Speed range  
24 W at nominal load  
1...50  
Asynchronous motor  
control profile  
Factory set : constant torque  
Sensorless flux vector control with PWM type motor  
control signal  
Electrical connection  
Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A,  
R2B, LI1...LI6 terminal 2.5 mm² AWG 14  
L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- terminal 2.5  
mm² AWG 14  
Supply  
Internal supply for logic inputs at 19...30 V <= 100 A  
for overload and short-circuit protection  
Internal supply for reference potentiometer (2.2 to  
10 kOhm) at 10...10.8 V <= 10 A for overload and  
short-circuit protection  
Communication port  
protocol  
CANopen  
Modbus  
IP degree of protection  
IP20 on upper part without cover plate  
IP21 on connection terminals  
IP31 on upper part  
IP41 on upper part  
Option card  
CANopen daisy chain communication card  
DeviceNet communication card  
Fipio communication card  
Modbus TCP communication card  
Profibus DP communication card  
Complementary  
Supply voltage limits  
170...264 V  
47.5...63 Hz  
1 kA  
Network frequency limits  
Prospective line Isc  
Continuous output current  
Speed drive output frequency  
Nominal switching frequency  
1.5 A at 4 kHz  
0.5...500 Hz  
4 kHz  
10/8/2011  
1
Switching frequency  
Transient overtorque  
Braking torque  
2...16 kHz adjustable  
150...170 % of nominal motor torque  
<= 150 % with braking resistor for 60 s  
100 % with braking resistor continuously  
150 % without braking resistor  
Regulation loop  
Frequency PI regulator  
Motor slip compensation  
Adjustable  
Automatic whatever the load  
Suppressable  
Output voltage  
<= power supply voltage  
Tightening torque  
0.6 N.m Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1...LI6  
0.8 N.m L1, L2, L3, U, V, W, PA, PB, PA/+, PC/-  
Insulation  
Electrical between power and control  
3
Analogue input number  
Analogue input type  
AI1 configurable voltage 0...10 V, input voltage 30 V max, impedance 30000  
Ohm  
AI2 configurable voltage +/- 10 V, input voltage 30 V max, impedance 30000  
Ohm  
AI3 configurable current 0...20 mA, impedance 250 Ohm  
Sampling duration  
Response time  
AI1, AI2, AI3 8 ms for analog  
LI1...LI6 4 ms for discrete  
AOV, AOC 8 ms for analog  
R1A, R1B, R1C, R2A, R2B 8 ms for discrete  
Linearity error  
+/- 0.2 % for output  
2
Analogue output number  
Analogue output type  
AOC configurable current 0...20 mA, impedance 800 Ohm, resolution 8 bits  
AOV configurable voltage 0...10 V, impedance 470 Ohm, resolution 8 bits  
Discrete input logic  
LI1...LI4 logic input not wired , < 13 V (state 1)  
LI1...LI6 negative logic (source), > 19 V (state 0)  
LI1...LI6 positive logic (source), < 5 V (state 0), > 11 V (state 1)  
Discrete output number  
Discrete output type  
2
R1A, R1B, R1C configurable relay logic 1 NO + 1 NC, electrical durability 100000  
cycles  
R2A, R2B configurable relay logic NC, electrical durability 100000 cycles  
Minimum switching current  
Maximum switching current  
R1-R2 10 mA at 5 V DC  
R1-R2 on inductive load, 2 A at 250 V AC, cos phi = 0.4, L/R = 7 ms  
R1-R2 on inductive load, 2 A at 30 V DC, cos phi = 0.4, L/R = 7 ms  
R1-R2 on resistive load, 5 A at 250 V AC, cos phi = 1, L/R = 0 ms  
R1-R2 on resistive load, 5 A at 30 V DC, cos phi = 1, L/R = 0 ms  
Discrete input number  
6
Discrete input type  
LI1...LI6 programmable 24 V 0...100 mA with PLC, impedance 3500 Ohm  
Acceleration and deceleration ramps  
Linear adjustable separately from 0.1 to 999.9 s  
S, U or customized  
Braking to standstill  
Protection type  
By DC injection  
Input phase breaks drive  
Line supply overvoltage and undervoltage safety circuits drive  
Line supply phase loss safety function, for three phases supply drive  
Motor phase breaks drive  
Overcurrent between output phases and earth (on power up only) drive  
Overheating protection drive  
Short-circuit between motor phases drive  
Thermal protection motor  
Insulation resistance  
Local signalling  
>= 500 MOhm at 500 V DC for 1 minute  
1 LED red for drive voltage  
Four 7-segment display units for CANopen bus status  
Time constant  
5 ms for reference change  
Frequency resolution  
Analog input 0.1...100 Hz  
Display unit 0.1 Hz  
Type of connector  
Physical interface  
Transmission frame  
Transmission rate  
1 RJ45 Modbus/CANopen  
RS485 multidrop serial link  
RTU  
10, 20, 50, 125, 250, 500 kbps or 1 Mbps CANopen  
4800, 9600 or 19200 bps Modbus  
Number of addresses  
1...127 CANopen  
1...247 Modbus  
2
Number of drive  
127 CANopen  
31 Modbus  
Marking  
CE  
Operating position  
Product weight  
Vertical +/- 10 degree  
1.5 kg  
Environment  
Dielectric strength  
2040 V DC between earth and power terminals  
2880 V AC between control and power terminals  
Electromagnetic compatibility  
1.2/50 µs - 8/20 µs surge immunity test conforming to IEC 61000-4-5 level 3  
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 level 4  
Electrostatic discharge immunity test conforming to IEC 61000-4-2 level 3  
Radiated radio-frequency electromagnetic field immunity test conforming to IEC  
61000-4-3 level 3  
Standards  
IEC 61800-5-1  
Product certifications  
CSA  
C-Tick  
GOST  
NOM  
UL  
Pollution degree  
2
Protective treatment  
Vibration resistance  
TC  
1 gn (f = 13...150 Hz) conforming to EN/IEC 60068-2-6  
1.5 mm (f = 3...13 Hz) conforming to EN/IEC 60068-2-6  
Shock resistance  
Relative humidity  
15 gn for 11 ms conforming to EN/IEC 60068-2-27  
5...95 % without condensation conforming to IEC 60068-2-3  
5...95 % without dripping water conforming to IEC 60068-2-3  
Ambient air temperature for storage  
Ambient air temperature for operation  
-25...70 °C  
-10...50 °C without derating with protective cover on top of the drive  
-10...60 °C with derating factor without protective cover on top of the drive  
Operating altitude  
<= 1000 m without derating  
>= 1000 m with current derating 1 % per 100 m  
RoHS EUR status  
Compliant  
0913  
RoHS EUR conformity date  
3

相关型号:

ATV312H018M3

Altivar 312 drive selection guide
ETC

ATV312H037M2

Altivar 312 drive selection guide
ETC

ATV312H037M3

Altivar 312 drive selection guide
ETC

ATV312H037N4

variable speed drive ATV312 - 0.37kW -1.5kVA - 32W - 380..500 V- 3-phase supply
ETC

ATV312H055M2

Altivar 312 drive selection guide
ETC

ATV312H055M3

Altivar 312 drive selection guide
ETC

ATV312H055N4

Altivar 312 drive selection guide
ETC

ATV312H075M2

Altivar 312 drive selection guide
ETC

ATV312H075M3

Altivar 312 drive selection guide
ETC

ATV312H075N4

Altivar 312 drive selection guide
ETC

ATV312H075S6

Altivar 312 drive selection guide
ETC

ATV312HD11M3

Altivar 312 drive selection guide
ETC