Characteristics
ATV312H018M2
variable speed drive ATV312 - 0.18kW -
0.6kVA - 24W - 200..240 V- 1-phase supply
Main
Range of product
Altivar 312
Product or component
type
Variable speed drive
Product destination
Asynchronous motors
Simple machine
Product specific
application
Assembly style
Component name
Motor power kW
Motor power hp
With heat sink
ATV312
0.18 kW
0.25 hp
[Us] rated supply
voltage
200...240 V (- 5...5 %)
Supply frequency
50...60 Hz (- 5...5 %)
Single phase
Network number of
phases
Line current
3 A for 200 V, 1 kA
2.5 A for 240 V
EMC filter
Integrated
0.6 kVA
Apparent power
Maximum transient
current
2.3 A for 60 s
Power dissipation in W
Speed range
24 W at nominal load
1...50
Asynchronous motor
control profile
Factory set : constant torque
Sensorless flux vector control with PWM type motor
control signal
Electrical connection
Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A,
R2B, LI1...LI6 terminal 2.5 mm² AWG 14
L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- terminal 2.5
mm² AWG 14
Supply
Internal supply for logic inputs at 19...30 V <= 100 A
for overload and short-circuit protection
Internal supply for reference potentiometer (2.2 to
10 kOhm) at 10...10.8 V <= 10 A for overload and
short-circuit protection
Communication port
protocol
CANopen
Modbus
IP degree of protection
IP20 on upper part without cover plate
IP21 on connection terminals
IP31 on upper part
IP41 on upper part
Option card
CANopen daisy chain communication card
DeviceNet communication card
Fipio communication card
Modbus TCP communication card
Profibus DP communication card
Complementary
Supply voltage limits
170...264 V
47.5...63 Hz
1 kA
Network frequency limits
Prospective line Isc
Continuous output current
Speed drive output frequency
Nominal switching frequency
1.5 A at 4 kHz
0.5...500 Hz
4 kHz
10/8/2011
1
Switching frequency
Transient overtorque
Braking torque
2...16 kHz adjustable
150...170 % of nominal motor torque
<= 150 % with braking resistor for 60 s
100 % with braking resistor continuously
150 % without braking resistor
Regulation loop
Frequency PI regulator
Motor slip compensation
Adjustable
Automatic whatever the load
Suppressable
Output voltage
<= power supply voltage
Tightening torque
0.6 N.m Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1...LI6
0.8 N.m L1, L2, L3, U, V, W, PA, PB, PA/+, PC/-
Insulation
Electrical between power and control
3
Analogue input number
Analogue input type
AI1 configurable voltage 0...10 V, input voltage 30 V max, impedance 30000
Ohm
AI2 configurable voltage +/- 10 V, input voltage 30 V max, impedance 30000
Ohm
AI3 configurable current 0...20 mA, impedance 250 Ohm
Sampling duration
Response time
AI1, AI2, AI3 8 ms for analog
LI1...LI6 4 ms for discrete
AOV, AOC 8 ms for analog
R1A, R1B, R1C, R2A, R2B 8 ms for discrete
Linearity error
+/- 0.2 % for output
2
Analogue output number
Analogue output type
AOC configurable current 0...20 mA, impedance 800 Ohm, resolution 8 bits
AOV configurable voltage 0...10 V, impedance 470 Ohm, resolution 8 bits
Discrete input logic
LI1...LI4 logic input not wired , < 13 V (state 1)
LI1...LI6 negative logic (source), > 19 V (state 0)
LI1...LI6 positive logic (source), < 5 V (state 0), > 11 V (state 1)
Discrete output number
Discrete output type
2
R1A, R1B, R1C configurable relay logic 1 NO + 1 NC, electrical durability 100000
cycles
R2A, R2B configurable relay logic NC, electrical durability 100000 cycles
Minimum switching current
Maximum switching current
R1-R2 10 mA at 5 V DC
R1-R2 on inductive load, 2 A at 250 V AC, cos phi = 0.4, L/R = 7 ms
R1-R2 on inductive load, 2 A at 30 V DC, cos phi = 0.4, L/R = 7 ms
R1-R2 on resistive load, 5 A at 250 V AC, cos phi = 1, L/R = 0 ms
R1-R2 on resistive load, 5 A at 30 V DC, cos phi = 1, L/R = 0 ms
Discrete input number
6
Discrete input type
LI1...LI6 programmable 24 V 0...100 mA with PLC, impedance 3500 Ohm
Acceleration and deceleration ramps
Linear adjustable separately from 0.1 to 999.9 s
S, U or customized
Braking to standstill
Protection type
By DC injection
Input phase breaks drive
Line supply overvoltage and undervoltage safety circuits drive
Line supply phase loss safety function, for three phases supply drive
Motor phase breaks drive
Overcurrent between output phases and earth (on power up only) drive
Overheating protection drive
Short-circuit between motor phases drive
Thermal protection motor
Insulation resistance
Local signalling
>= 500 MOhm at 500 V DC for 1 minute
1 LED red for drive voltage
Four 7-segment display units for CANopen bus status
Time constant
5 ms for reference change
Frequency resolution
Analog input 0.1...100 Hz
Display unit 0.1 Hz
Type of connector
Physical interface
Transmission frame
Transmission rate
1 RJ45 Modbus/CANopen
RS485 multidrop serial link
RTU
10, 20, 50, 125, 250, 500 kbps or 1 Mbps CANopen
4800, 9600 or 19200 bps Modbus
Number of addresses
1...127 CANopen
1...247 Modbus
2
Number of drive
127 CANopen
31 Modbus
Marking
CE
Operating position
Product weight
Vertical +/- 10 degree
1.5 kg
Environment
Dielectric strength
2040 V DC between earth and power terminals
2880 V AC between control and power terminals
Electromagnetic compatibility
1.2/50 µs - 8/20 µs surge immunity test conforming to IEC 61000-4-5 level 3
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 level 4
Electrostatic discharge immunity test conforming to IEC 61000-4-2 level 3
Radiated radio-frequency electromagnetic field immunity test conforming to IEC
61000-4-3 level 3
Standards
IEC 61800-5-1
Product certifications
CSA
C-Tick
GOST
NOM
UL
Pollution degree
2
Protective treatment
Vibration resistance
TC
1 gn (f = 13...150 Hz) conforming to EN/IEC 60068-2-6
1.5 mm (f = 3...13 Hz) conforming to EN/IEC 60068-2-6
Shock resistance
Relative humidity
15 gn for 11 ms conforming to EN/IEC 60068-2-27
5...95 % without condensation conforming to IEC 60068-2-3
5...95 % without dripping water conforming to IEC 60068-2-3
Ambient air temperature for storage
Ambient air temperature for operation
-25...70 °C
-10...50 °C without derating with protective cover on top of the drive
-10...60 °C with derating factor without protective cover on top of the drive
Operating altitude
<= 1000 m without derating
>= 1000 m with current derating 1 % per 100 m
RoHS EUR status
Compliant