B128724060 [ETC]

Timers Delay on Release; 延时定时器上发布
B128724060
型号: B128724060
厂家: ETC    ETC
描述:

Timers Delay on Release
延时定时器上发布

文件: 总2页 (文件大小:65K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Timers  
Delay on Release  
Types B 128, B 121  
• Time ranges: 0.15 s to 60 s  
• Automatic start after drop out of power supply  
• Knob-adjustable time within range  
• Repeatability deviation: 1%  
• Output: 10 A SPDT relay  
• Plug-in type module  
• Scantimer housing  
• LED-indication for supply on  
• AC or DC power supply  
Product Description  
Ordering Key  
Function  
Output  
Type  
Power supply  
Time range  
B 128 220 006  
Mono-function, plug-in, delay used to switch on an exhaust  
on release, miniature time re- fan and keep it running for a  
lays up to 60 s covering 2 certain period of time after  
individual time ranges. These disconnection of power sup-  
economical timers are often ply.  
Type Selection  
Plug  
Output Time ranges  
Supply: 24 VAC  
Supply: 120 VAC  
Supply: 220 VAC Supply: 24 VDC  
Circular  
8 pins  
SPDT  
SPDT  
0.15 - 6 s  
1.5 - 60 s  
B 128 024 006  
B 128 024 060  
B 128 120 006  
B 128 120 060  
B 128 220 006  
B 128 220 060  
B 128 724 006  
B 128 724 060  
Circular  
11 pins  
0.15 - 6 s  
1.5 - 60 s  
B 121 024 006  
B 121 024 060  
B 121 120 006  
B 121 120 060  
B 121 220 006  
B 121 220 060  
B 121 724 006  
B 121 724 060  
Time Specifications  
Output Specifications  
Output  
SPDT relay  
250 VAC (rms)  
(contact/electronics)  
Time ranges  
0.15 -  
1.5  
6 s  
60 s  
Basic electrical insulation  
-
Time range accuracy  
0 to +20% on max.  
min. actual time min.  
set time  
Contact ratings (AgCdO)  
Resistive loads  
µ (micro gap)  
AC 1  
DC 1  
or  
10 A/250VAC (2500 VA)  
1 A/250 VDC (250 W)  
10 A/25 VDC (250 W)  
2.5 A/230 VAC  
5 A/24 VDC  
30 x 106 operations  
Repeatability deviation  
Time variation  
Within rated power supply  
and ambient temperature  
1%  
Small inductive loads AC 15  
DC 13  
0.05%/V  
0.2%/°C  
Mechanical life  
Electrical life  
Reset  
Time and/or relay  
Power supply interruption  
500 ms  
AC 1  
2.5 x 105 operations  
(at max. load)  
Operating frequency  
7200 operations/h  
Insulation voltages  
Rated insulation voltage  
2.0 kVAC (rms) (cont./elec.)  
Rated transient protection volt. 4 kV (1.2/50 µs) (cont./elec.)  
(IEC 60664)  
Specifications are subject to change without notice (25.10.99)  
1
B 128, B 121  
General Specifications  
Supply Specifications  
Power ON time  
Indication for  
Power supply ON  
200 ms  
Power supply AC types  
Installation cat. III (IEC 60664)  
Rated operational voltage  
Through pins 2 & 10  
or pins 2 & 7  
220  
220 VAC ±15%,  
45 to 65 Hz  
120 VAC ±15%,  
45 to 65 Hz  
24 VAC ±15%,  
45 to 65 Hz  
10 ms  
LED, red  
Environment  
Degree of protection  
Pollution degree  
Operating temperature  
Storage temperature  
120  
024  
IP 20 B  
2 (IEC 60664)  
-20° to +50°C (-4° to +122°F)  
-50° to +85°C (-58° to +185°F)  
Dropout tolerance  
Rated insulation voltage  
Weight  
85 g  
None  
Rated transient protection volt. 4 kV (1.2/50 µs) @ 220 VAC  
2.5 kV (1.2/50 µs) @ 120 VAC  
Approval  
UL, CSA  
800 V (1.2/50 µs) @ 24 VAC  
(line/neutral)  
Power supply DC type  
Rated operational voltage 724 24 VDC + 15/- 20% (pin 2 pos.)  
Rated insulation voltage None  
Rated transient protection volt. 800 V (1.2/50 µs)  
Installation cat. III (IEC 60664)  
Consumption  
AC supply  
DC supply  
60 mA @ 50 Hz/70 mA @ 60 Hz  
1 W  
Mode of Operation  
Wiring Diagrams  
The relay operates immedi- B 121/B 128 monitor that  
ately after power supply is power supply is applied. If  
SPDT  
8 pin  
SPDT  
11 pin  
applied.  
power supply is interrupted,  
the relay starts e.g. an alarm  
When power supply is inter- (battery driven) after the time  
rupted, the time period starts period has expired.  
and at the end of the set time  
the relay releases.  
Please note  
B 128 and B 121 should not  
If power supply is reapplied be operated by pulses shorter  
before the relay releases, the than 500 ms.  
time is reset and the relay  
Power supply  
B 128  
Power supply  
B 121  
remains on.  
Time Setting  
Knob-adjustable on scale in  
Accessories  
Sockets◊  
S 408, S 411  
HF  
SM 13  
BB 4  
Hold down spring◊  
Mounting rack  
Socket cover  
seconds.  
Potentiometer lock  
PL 1  
For further information refer "Accessories".  
Operation Diagram  
Power supply  
Relay on  
2
Specifications are subject to change without notice (25.10.99)  

相关型号:

B12A12005L310100U253

Thermal motor protector Temperature limiter Thermal cut-out
ETC

B12A1B

Process Sealed Subminiature Antistatic Toggles
NKK

B12A1B-GA

General Specifications
OHMITE

B12A1B-GB

General Specifications
OHMITE

B12A1B-GC

General Specifications
OHMITE

B12A1B-GE

General Specifications
OHMITE

B12A1B-GF

General Specifications
OHMITE

B12A1B-GG

General Specifications
OHMITE

B12A1B-GH

General Specifications
OHMITE

B12A1B-JA

General Specifications
OHMITE

B12A1B-JB

General Specifications
OHMITE

B12A1B-JC

General Specifications
OHMITE