B82432H1332K [ETC]

INDUCTOR 1812H 3.3UH ; 电感1812H器3.3uH\n
B82432H1332K
型号: B82432H1332K
厂家: ETC    ETC
描述:

INDUCTOR 1812H 3.3UH
电感1812H器3.3uH\n

文件: 总7页 (文件大小:146K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
EMC  
Components  
RF Chokes  
High Current  
B82442-H  
Data Book Supplement  
RF Chokes  
B82442-H  
SIMID 05 Series – High Current  
SIMID 05 (Siemens-Miniature-Inductors)  
Rated inductance 1 to 10000 µH  
Rated current 0,035 to 2,5 A  
Construction  
Size as EIA standard: 2220  
Upright ferrite drum core  
Laser welded, encapsulation flame retardant  
Temperature index of copper wire enamel: 180°C  
Features  
Very high rated current  
High L values  
Suitable for reflow (IR and vapor phase)  
and wave soldering  
Applications  
Filtering of supply voltages, coupling, decoupling  
DC/DC converters  
Automotive electronics  
Telecommunication  
Terminals  
Tinned  
Base material CuSn6; 0,4 µm Cu; 1–2 µm Ag; 5–7 µm Sn  
No leaching during wave soldering  
Marking  
Marking on component:  
Manufacturer, date code,  
L value and tolerance of L value (coded)  
Minimum marking on reel:  
Manufacturer, part number, ordering code,  
L value and tolerance of L value, quantity, date of packing  
Delivery mode  
Blister tape 12 mm, reel packing dia. 330 mm.  
For details on taping, packing and packing units refer to data book  
"EMC Components", page 433.  
2
3.98  
Siemens Matsushita Components  
RF Chokes  
B82442-H  
SIMID 05 Series – High Current  
Dimensional drawing  
Size as per EIA standard: 2220  
Approx. weight 400 mg  
PCB layout recommendation  
Dimensions (mm)  
A
B
C
D
Wave/reflow soldering  
4,5  
2,0  
4,0  
8,0  
1) Soldering area, tinned  
Siemens Matsushita Components  
3.98  
3
RF Chokes  
B82442-H  
SIMID 05 Series – High Current  
Technical data and ordering codes  
For further technical data see page 7.  
LR  
µH  
Toler-  
ance  
Qmin  
fL; fQ  
MHz  
IR  
A
Rmax  
fres, min  
MHz  
Ordering code1)  
1,0  
1,2  
1,5  
± 10 %  
10  
10  
10  
7,96  
7,96  
7,96  
2,50  
2,35  
2,20  
0,024  
0,028  
0,032  
95  
70  
55  
B82442-H1102-K  
B82442-H1122-K  
B82442-H1152-K  
K
=
ˆ
1,8  
2,2  
2,7  
10  
10  
10  
7,96  
7,96  
7,96  
2,00  
1,80  
1,70  
0,040  
0,048  
0,056  
47  
42  
37  
B82442-H1182-K  
B82442-H1222-K  
B82442-H1272-K  
3,3  
3,9  
4,7  
10  
10  
10  
7,96  
7,96  
7,96  
1,55  
1,45  
1,35  
0,064  
0,072  
0,088  
34  
32  
29  
B82442-H1332-K  
B82442-H1392-K  
B82442-H1472-K  
5,6  
6,8  
8,2  
10  
10  
10  
7,96  
7,96  
7,96  
1,25  
1,13  
1,05  
0,104  
0,120  
0,144  
26  
24  
22  
B82442-H1562-K  
B82442-H1682-K  
B82442-H1822-K  
10  
12  
15  
10  
10  
10  
2,52  
2,52  
2,52  
1,00  
0,88  
0,81  
0,168  
0,20  
0,24  
19  
17  
16  
B82442-H1103-K  
B82442-H1123-K  
B82442-H1153-K  
18  
22  
27  
10  
10  
10  
2,52  
2,52  
2,52  
0,74  
0,67  
0,62  
0,29  
0,35  
0,42  
14  
13  
11,5  
B82442-H1183-K  
B82442-H1223-K  
B82442-H1273-K  
33  
39  
47  
± 5 %  
10  
10  
10  
2,52  
2,52  
2,52  
0,56  
0,52  
0,48  
0,50  
0,58  
0,68  
10,5  
9,5  
8,5  
B82442-H1333-+  
B82442-H1393-+  
B82442-H1473-+  
J
=
ˆ
± 10 %  
56  
68  
82  
K
10  
10  
10  
2,52  
2,52  
2,52  
0,43  
0,40  
0,38  
0,80  
0,96  
1,12  
7,8  
7,0  
6,4  
B82442-H1563-+  
B82442-H1683-+  
B82442-H1823-+  
=
ˆ
1) Replace the + by the code letter for the required inductance tolerance.  
4
3.98  
Siemens Matsushita Components  
RF Chokes  
B82442-H  
SIMID 05 Series – High Current  
Technical data and ordering codes  
For further technical data see page 7.  
LR  
µH  
Toler-  
ance  
Qmin  
fL; fQ  
MHz  
IR  
A
Rmax  
fres, min  
MHz  
Ordering code1)  
100  
120  
150  
± 5 %  
20  
20  
20  
0,796  
0,796  
0,796  
0,35  
0,32  
0,29  
1,28  
1,52  
1,76  
6,0  
5,4  
4,8  
B82442-H1104-+  
B82442-H1124-+  
B82442-H1154-+  
J
=
ˆ
± 10 %  
180  
220  
270  
K
20  
20  
20  
0,796  
0,796  
0,796  
0,27  
0,24  
0,22  
2,24  
2,72  
3,36  
4,4  
3,9  
3,6  
B82442-H1184-+  
B82442-H1224-+  
B82442-H1274-+  
=
ˆ
330  
390  
470  
20  
20  
20  
0,796  
0,796  
0,796  
0,20  
0,18  
0,17  
3,92  
4,64  
5,60  
3,2  
2,9  
2,6  
B82442-H1334-+  
B82442-H1394-+  
B82442-H1474-+  
560  
680  
820  
20  
20  
20  
0,796  
0,796  
0,796  
0,15  
0,14  
0,13  
6,80  
8,00  
10,4  
2,4  
2,2  
2,0  
B82442-H1564-+  
B82442-H1684-+  
B82442-H1824-+  
1000  
1200  
1500  
30  
30  
30  
0,252  
0,252  
0,252  
0,120  
0,105  
0,100  
12,0  
13,6  
16,0  
1,8  
1,5  
1,4  
B82442-H1105-+  
B82442-H1125-+  
B82442-H1155-+  
1800  
2200  
2700  
30  
30  
30  
0,252  
0,252  
0,252  
0,085  
0,075  
0,065  
24,0  
28,0  
44,0  
1,3  
1,2  
1,1  
B82442-H1185-+  
B82442-H1225-+  
B82442-H1275-+  
3300  
3900  
4700  
30  
30  
30  
0,252  
0,252  
0,252  
0,055  
0,053  
0,050  
48,0  
56,0  
62,4  
1,0  
1,0  
0,9  
B82442-H1335-+  
B82442-H1395-+  
B82442-H1475-+  
5600  
6800  
8200  
30  
30  
30  
0,252  
0,252  
0,252  
0,046  
0,042  
0,039  
68,0  
88,0  
100  
0,8  
0,7  
0,6  
B82442-H1565-+  
B82442-H1685-+  
B82442-H1825-+  
10000  
30  
0,0796  
0,035  
120  
0,5  
B82442-H1106-+  
1) Replace the + by the code letter for the required inductance tolerance.  
Siemens Matsushita Components  
3.98  
5
RF Chokes  
B82442-H  
SIMID 05 Series – High Current  
Impedance |Z|  
Inductance L  
versus frequency f  
measured with impedance analyzer  
HP 4194A/HP 4191A  
versus dc load IDC  
measured with LCR meter  
HP 4275A  
Q factor  
Current derating Iop/IR  
versus ambient  
temperature TA  
versus frequency f  
measured with impedance analyzer  
HP 4194A  
(Rated temperature TR = 85°C)  
6
3.98  
Siemens Matsushita Components  
RF Chokes  
B82442-H  
SIMID 05 Series – High Current  
General technical data  
Rated inductance LR  
Measured at frequency fL,  
with impedance analyzer HP 4194A  
Q factor Qmin  
Measured at frequency fQ,  
with impedance analyzer HP 4194A  
Rated current IN  
Maximum permissible dc with  
an inductance decrease of L/L0 10 %  
and/or temperature increase of 40 K  
at rated temperature TR = 85°C  
(see derating curves)  
Self resonance frequency fres, min  
DC resistance Rmax  
Measured with network analyzer  
HP 8753D  
Measured at 20°C ambient temperature,  
Measuring current < IR  
Climatic category  
In accordance with IEC 68-1  
55/125/56 (– 55°C/+ 125°C/56 days damp heat test)  
Solderability  
(215 ± 3)°C, (3 ± 0,3) s  
Wetting of soldering area: 90 %  
Resistance to soldering heat  
Permissible PCB bending  
In accordance with IEC 68-2-20, test Tb  
260°C, 10 s  
2 mm (100 mm long standard PCB)  
Published by Siemens Matsushita Components GmbH & Co. KG  
Marketing Kommunikation, Postfach 80 17 09, D-81617 München  
Siemens Matsushita Components 1998. All Rights Reserved.  
Asfaraspatentsorotherrightsofthirdpartiesareconcerned,liabilityisonlyassumedforcomponents  
per se, not for applications, processes and circuits implemented within components or assemblies.  
The information describes the type of component and shall not be considered as assured  
characteristics.  
Terms of delivery and rights to change design reserved.  
This brochure replaces the previous edition.  
For questions on technology, prices and delivery please contact the Sales Offices of Siemens AG,  
Passive Components and Electron Tubes Group, in the Federal Republic of Germany or the inter-  
national Siemens Companies and Representatives.  
Due to technical requirements components may contain dangerous substances. For information on  
the type in question please also contact one of our Sales Offices.  
Siemens Matsushita Components  
3.98  
7

相关型号:

B82432H1333K

INDUCTOR 1812H 33UH
ETC

B82432H1334K

INDUCTOR 1812H 330UH
ETC

B82432H1472K

INDUCTOR 1812H 4.7UH
ETC

B82432H1473K

INDUCTOR 1812H 47UH
ETC

B82432T

SIMID series, SIMID 1812-T
EPCOS

B82432T1102K000

SMT inductors
EPCOS

B82432T1102K000

SMD/SMT 电感器(线圈)
TDK

B82432T1103K000

SMT inductors
EPCOS

B82432T1103K000

SMD/SMT 电感器(线圈)
TDK

B82432T1104K000

SMT inductors
EPCOS

B82432T1104K000

SMD/SMT 电感器(线圈)
TDK

B82432T1105K000

SMT inductors
EPCOS