Model ESP906CL  
Vlinx Ethernet Serial Server  
Ethernet Enable Any Serial Device  
Now you can Ethernet enable any serial device—even your legacy digital current loops. Use B&B’s Vlinx Serial Server  
technology to put your serial ports to work for you. Imagine the ability to communicate with every piece of equipment  
from any networked PC. Eliminate site visits just to make a minor configuration changes. Reduce service calls and  
increase productivity by knowing what your equipment is doing before you get a trouble-report. Spend more time doing  
the work you are paid to do instead of chasing down nuisance problems in remotely located equipment.  
Do you have equipment with RS-232/422/485 or current loop interfaces that you  
have left unconnected? Many new and existing installations have equipment with  
unused ports for programming, monitoring or diagnostics. With B&B’s Vlinx Serial  
Servers, you can put all those ports to work for you.  
Simply connect the Vlinx server to the equipment’s serial port, and connect the Vlinx Ethernet port to your LAN. Your  
equipment is now online. It will appear as a local COM port on any networked PC running our Virtual Serial Port  
software. No software customization required, just run the appropriate software for your equipment.  
Industry Applications  
B&B Electronics' new Model ESP906CL integrates the benefits of Ethernet communications with existing serial devices  
by offering four configurable RS-232/422/485 serial ports and two digital current loop ports. The Ethernet connection  
will auto select 10BaseT or 100BaseTX. The ESP906CL provides a Windows host control over serial devices located  
virtually anywhere on a TCP/IP or UDP/IP Ethernet connection. It even gives authorized users control over the  
connected serial device or the ESP906CL Menu from anywhere outside the LAN.  
Operational Modes  
Virtual COM port  
TCP/IP socket and tunneling  
UDP/IP socket and tunneling  
Features  
DIN rail or panel mount  
Supports 10/100 Mbps Ethernet  
Supports RS-232, RS-422, and RS-485 and digital current loop interfaces  
Remotely upgrade or restore to default settings  
Manual and remote management of console mode  
Supports LAN and WAN communications  
Supports multiple TCP client connections  
Management access password protected.  
Product Specifications  
Serial Memory: 8K bytes per port  
Serial Connections: six – RJ-45  
Ethernet Connection: RJ-45  
ESP906CL-4814 - 2/2  
© 2014 by B&B Electronics. All rights reserved.  
Interface  
Serial Ports 1, 2, 3 & 4:  
RS-232, RS-422, or RS-485, software selectable  
Current Loop Ports 5 & 6: Two wire active, 34 mA @ 28 VDC max load  
LAN:  
Supported Signals:  
10/100 Mbps Auto-detecting – 10 Base T, 100 Base TX  
RS-232: TX, RX, RTS, CTS, DTR, DSR, DCD, GND  
RS-422: TX(A)-, TX(B)+, RX(A)-, RX(B)+, GND  
RS-485: Data(A)-, Data(B)+  
Data Rate:  
Protocols:  
110 bps to 230.4 kbps  
TCP, IP, ARP, DHCP, Telnet, HTTP, UDP, ICMP  
Management:  
Vlinx Manager for Windows 98, ME, 2000, 2003 server, XP, Vista, NT4.0,  
Serial Console, Telnet, Web server, Firmware upgradeable  
Power & Environment  
Power Requirements:  
3 output power supply (included)  
36 VDC1 @ 35 mA  
36 VDC2 @ 35 mA  
5 VDC @ 412 mA  
Operating Temperature: 0 to 40 °C  
Storage Temperature:  
Dimensions:  
Humidity:  
-20 to 85 °C  
4.48 x 7.3 x 1.1 in (11.4 x 18.5 x 2.9 cm)  
0 - 90% non-condensing  
FCC, CE  
Approvals:  
ESP Manager Software  
Vlinx ESP Manager allows easy access to the serial server to configure the  
server and ports, upgrade server firmware and monitor port status and  
activity. When ESP Manager opens it will search for and display all  
ESP90x serial servers on the network.  
The Monitor Port feature allows you to use any PC on the LAN/WAN to  
actively view and troubleshoot the communications status. It shows when  
there is a client connection to the server and the client IP address. It  
displays the number of bytes transmitted and received as well as the status  
of the hardware handshaking lines.  
Web Server  
ESP906CL serial servers can be accessed and configured from any web  
browser (such as Internet Explorer) on the LAN/WAN. This allows you to  
remotely manage the software and your serial device. It also allows off-site  
troubleshooting.  
Heartbeat Connection  
Ensures Reliable Communications  
ESP906CL serial servers provide automatic resumption of the TCP data connection in case of a power failure or loss of  
an Ethernet connection on either the client or server. Once the Heartbeat connection is established the server sends a  
signal to the client every five seconds. If the signal is not received, the serial server will attempt to reconnect the TCP  
data connection every five seconds until communication is established again.  
System Integrators and OEMs  
Call and ask how B&B Electronics can best fill your product requirements.  
Accessories  
DRAD35.......... DIN-Rail Adapter Clips  

相关型号:

BB-ESR901

ETHERNET TO SER RS-232/422/485
ETC

BB-ESR902

ETHERNET TO SER RS-232/422/485
ETC

BB-ESR904

ETHERNET TO SER RS-232/422/485
ETC

BB-ESW105

NETWORK SWITCH-UNMANAGED 5 PORT
ETC

BB-ESW105-ML

NETWORK SWITCH-UNMANAGED 5 PORT
ETC

BB-ESW105-SL

NETWORK SWITCH-UNMANAGED 5 PORT
ETC

BB-ESW108

NETWORK SWITCH-UNMANAGED 8 PORT
ETC

BB-ESW108-ML

NETWORK SWITCH-UNMANAGED 8 PORT
ETC

BB-ESW108-SL

NETWORK SWITCH-UNMANAGED 8 PORT
ETC

BB-ESW205-MC

NETWORK SWITCH-UNMANAGED 5 PORT
ETC

BB-ESW205-MC-T

NETWORK SWITCH-UNMANAGED 5 PORT
ETC

BB-ESW205-MT

NETWORK SWITCH-UNMANAGED 5 PORT
ETC