BB-ESP906CL [ETC]
ETHERNET TO SER RS-232/422/485;型号: | BB-ESP906CL |
厂家: | ETC |
描述: | ETHERNET TO SER RS-232/422/485 以太网:16GBASE-T |
文件: | 总2页 (文件大小:144K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
ESP906CL-4814 - 1/2
© 2014 by B&B Electronics. All rights reserved.
Model ESP906CL
Vlinx Ethernet Serial Server
Ethernet Enable Any Serial Device
Now you can Ethernet enable any serial device—even your legacy digital current loops. Use B&B’s Vlinx Serial Server
technology to put your serial ports to work for you. Imagine the ability to communicate with every piece of equipment
from any networked PC. Eliminate site visits just to make a minor configuration changes. Reduce service calls and
increase productivity by knowing what your equipment is doing before you get a trouble-report. Spend more time doing
the work you are paid to do instead of chasing down nuisance problems in remotely located equipment.
Do you have equipment with RS-232/422/485 or current loop interfaces that you
have left unconnected? Many new and existing installations have equipment with
unused ports for programming, monitoring or diagnostics. With B&B’s Vlinx Serial
Servers, you can put all those ports to work for you.
Simply connect the Vlinx server to the equipment’s serial port, and connect the Vlinx Ethernet port to your LAN. Your
equipment is now online. It will appear as a local COM port on any networked PC running our Virtual Serial Port
software. No software customization required, just run the appropriate software for your equipment.
Industry Applications
B&B Electronics' new Model ESP906CL integrates the benefits of Ethernet communications with existing serial devices
by offering four configurable RS-232/422/485 serial ports and two digital current loop ports. The Ethernet connection
will auto select 10BaseT or 100BaseTX. The ESP906CL provides a Windows host control over serial devices located
virtually anywhere on a TCP/IP or UDP/IP Ethernet connection. It even gives authorized users control over the
connected serial device or the ESP906CL Menu from anywhere outside the LAN.
Operational Modes
Virtual COM port
TCP/IP socket and tunneling
UDP/IP socket and tunneling
Features
DIN rail or panel mount
Supports 10/100 Mbps Ethernet
Supports RS-232, RS-422, and RS-485 and digital current loop interfaces
Remotely upgrade or restore to default settings
Manual and remote management of console mode
Supports LAN and WAN communications
Supports multiple TCP client connections
Management access password protected.
Product Specifications
Serial Memory: 8K bytes per port
Serial Connections: six – RJ-45
Ethernet Connection: RJ-45
ESP906CL-4814 - 2/2
© 2014 by B&B Electronics. All rights reserved.
Interface
Serial Ports 1, 2, 3 & 4:
RS-232, RS-422, or RS-485, software selectable
Current Loop Ports 5 & 6: Two wire active, 34 mA @ 28 VDC max load
LAN:
Supported Signals:
10/100 Mbps Auto-detecting – 10 Base T, 100 Base TX
RS-232: TX, RX, RTS, CTS, DTR, DSR, DCD, GND
RS-422: TX(A)-, TX(B)+, RX(A)-, RX(B)+, GND
RS-485: Data(A)-, Data(B)+
Data Rate:
Protocols:
110 bps to 230.4 kbps
TCP, IP, ARP, DHCP, Telnet, HTTP, UDP, ICMP
Management:
Vlinx Manager for Windows 98, ME, 2000, 2003 server, XP, Vista, NT4.0,
Serial Console, Telnet, Web server, Firmware upgradeable
Power & Environment
Power Requirements:
3 output power supply (included)
36 VDC1 @ 35 mA
36 VDC2 @ 35 mA
5 VDC @ 412 mA
Operating Temperature: 0 to 40 °C
Storage Temperature:
Dimensions:
Humidity:
-20 to 85 °C
4.48 x 7.3 x 1.1 in (11.4 x 18.5 x 2.9 cm)
0 - 90% non-condensing
FCC, CE
Approvals:
ESP Manager Software
Vlinx ESP Manager allows easy access to the serial server to configure the
server and ports, upgrade server firmware and monitor port status and
activity. When ESP Manager opens it will search for and display all
ESP90x serial servers on the network.
The Monitor Port feature allows you to use any PC on the LAN/WAN to
actively view and troubleshoot the communications status. It shows when
there is a client connection to the server and the client IP address. It
displays the number of bytes transmitted and received as well as the status
of the hardware handshaking lines.
Web Server
ESP906CL serial servers can be accessed and configured from any web
browser (such as Internet Explorer) on the LAN/WAN. This allows you to
remotely manage the software and your serial device. It also allows off-site
troubleshooting.
Heartbeat Connection
Ensures Reliable Communications
ESP906CL serial servers provide automatic resumption of the TCP data connection in case of a power failure or loss of
an Ethernet connection on either the client or server. Once the Heartbeat connection is established the server sends a
signal to the client every five seconds. If the signal is not received, the serial server will attempt to reconnect the TCP
data connection every five seconds until communication is established again.