BXRA-27E4000-H-00 [ETC]
Bridgelux RS Array Series;型号: | BXRA-27E4000-H-00 |
厂家: | ETC |
描述: | Bridgelux RS Array Series |
文件: | 总24页 (文件大小:588K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Bridgelux RS Array Series
Product Data Sheet DS25
BXRA-27x4000, BXRA-27x7000, BXRA-30x4000, BXRA-30x7000, BXRA-35x4000,
BXRA-35x7000, BXRA-40E4500, BXRA-40E7500, BXRA-5xC5300, BXRA-5xC9000
Introduction
The Bridgelux family of LED Array products delivers high performance, compact and cost-effective solid-
state lighting solutions to serve the general lighting market. These products combine the higher efficacy,
lifetime, and reliability benefits of LEDs with the light output levels of many conventional lighting sources.
The Bridgelux RS Array Series has been specified to enable lamp and luminaire designs with comparable
performance to existing high wattage CFL and HID conventional light sources for retail, commercial,
industrial and outdoor/street lighting applications. Bridgelux Arrays are extremely well equipped for all
types of light-on-demand applications, where they can be instantaneously and smoothly dimmed up or
down without any effect on lifetime, unlike traditional CFL and HID light sources.
The Bridgelux RS Array series provides a high performance alternative to conventional solid state
solutions, delivering between 3400 and 9000 lumens under application conditions in warm, neutral and
cool white color temperatures. These compact high flux density light sources deliver uniform high quality
illumination without pixilation or the multiple shadow effect caused by LED component based solutions,
enabling excellent beam control for precision lighting. To simplify system design for appropriate light
output, Bridgelux LED Arrays are specified to deliver performance under typical use conditions.
These integrated plug and play solutions reduce system complexity and enable miniaturized cost-
effective lamp and luminaire designs. Luminaire designs incorporating these LED Arrays deliver system
level performance comparable to that of 42-55 Watt CFL, 35-90 Watt low pressure sodium, 70-150 Watt
high pressure sodium or 70-200 Watt metal halide based luminaires and feature increased system level
and service life. Typical applications include retail lighting, commercial down lights, high bay, outdoor and
street lights, and entertainment lighting.
Features
Benefits
•
•
•
•
•
Compact high flux density light source
Enhanced optical control
•
•
•
•
Uniform high quality illumination
Minimum 70, 80 and 90 CRI options
Streamlined thermal path
Clean white light without pixilation
High quality true color reproduction
Significantly reduced thermal resistance
and increased operating temperatures
Energy Star / ANSI compliant color
binning structure with 3SDCM options
Uniform consistent white light
Lower operating costs
Increased safety
•
•
•
•
•
More energy efficient than incandescent,
halogen and fluorescent lamps
Easy to use with daylight and motion
detectors to enable increased energy
savings
•
•
•
•
Low voltage DC operation
Instant light with unlimited dimming
5-Year warranty
Reduced maintenance costs
•
•
RoHS compliant and Pb free
Environmentally friendly, no disposal issue
101 Portola Avenue, Livermore, CA 94551
• Tel: (925) 583-8400 • Fax: (925) 583-8401 • www.bridgelux.com
Table of Contents
Page
Product Nomenclature
3
3
Average Lumen Maintenance Characteristics
Environmental Compliance
3
UL Recognition
4
Minor Product Change Policy
4
Cautionary Statements
4
Case Temperature Measurement Point
Quick Selection Guide
5
6
Flux Characteristics
7
Optical Characteristics
8
Electrical Characteristics
9
Absolute Minimum and Maximum Ratings
Typical Performance at Alternative Drive Currents
Mechanical Dimensions
10
11
13
14
15
16
17
18
19
20
23
Typical Radiation Pattern
Wavelength Characteristics at Rated Test Current, Tj=25°C
Typical Relative Luminous Flux vs. Current, Tj=25°C
Typical Light Output Characteristics vs. Temperature
Typical Chromaticity Characteristics vs. Temperature
Forward Current Characteristics
Color Binning Information
Design Resources
Bridgelux RS Array Series Product Data Sheet DS25 (12/3/11)
Page 2 of 24
Product Nomenclature
The part number designation for Bridgelux LED Arrays is explained as follows:
BXRA – AB C DEFG – H – IJ - KLM
Where:
BXRA – Designates product family
AB – Designates the nominal ANSI color temperature; 27 = 2700K; 30 = 3000K, etc.
C - Designates minimum CRI; C = 70, E = 80, G = 90
DEFG - Designates Nominal Flux; 4000 = 4000lm, 7000 = 7000lm, 9000 = 9000lm, etc.
H – Designates configuration
IJ – Designates CCT Bin options
3000K as an example:
00 = Full ANSI: Q3, Q4, R3, R4
03 = 3 SDCM
KLM – Designates wire option
Average Lumen Maintenance Characteristics
Bridgelux projects that its family of LED Array products will deliver, on average, greater than 70% lumen
maintenance after 50,000 hours of operation at the rated forward test current. This performance
assumes constant current operation with case temperature maintained at or below 85°C. For use beyond
these typical operating conditions please consult your Bridgelux sales representative for further
assistance.
These projections are based on a combination of package test data, semiconductor chip reliability data, a
fundamental understanding of package related degradation mechanisms, and performance observed
from products installed in the field using Bridgelux die technology. Bridgelux conducts lumen
maintenance tests per LM80. Observation of design limits is required in order to achieve this projected
lumen maintenance.
Environmental Compliance
Bridgelux is committed to providing environmentally friendly products to the solid-state lighting market.
Bridgelux LED Arrays are compliant to the European Union directives on the restriction of hazardous
substances in electronic equipment, namely the RoHS directive. Bridgelux does not intentionally add the
following restricted materials to LED Array products: lead, mercury, cadmium, hexavalent chromium,
polybrominated biphenyls (PBB) or polybrominated diphenyl ethers (PBDE).
Bridgelux RS Array Series Product Data Sheet DS25 (12/3/11)
Page 3 of 24
UL Recognition
Bridgelux secures UL Recognition for all the LED Array products. We continue to add arrays as they are
recognized by UL. Please refer to the UL file E333389 for the latest list of UL Recognized Arrays.
Bridgelux uses UL Recognized materials with suitable flammability ratings in the LED Array to streamline
the process for customers to secure UL listing of the final luminaire product. Bridgelux recommends that
luminaires are designed with a Class 2 Driver to facilitate the UL listing process.
Minor Product Change Policy
The rigorous qualification testing on products offered by Bridgelux provides performance assurance.
Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product
optimization.
Cautionary Statements
CAUTION: CONTACT WITH OPTICAL AREA
Do not touch the optical area of the LED Array. Avoid any contact with the optical area. Applying stress
to the yellow phosphor resin area can result in damage to the LED Array.
Optics and reflectors must not be mounted in contact with the white phosphor resin area or the white ring
that surrounds the yellow phosphor area. Using the white ring to secure optics can result in damage to
the LED Array as the ring is not designed to act as a mechanical locating feature. Optical devices may be
mounted on the top surface of the LED Array substrate outside of the white ring maximum OD as
specified in the product data sheet. Use the mechanical features of the LED Array substrate edges
and/or mounting holes to locate and secure the optical device as needed.
CAUTION: EYE SAFETY
Eye safety classification for the use of Bridgelux LED Arrays is in accordance with IEC specification
EN62471; Photobiological Safety of Lamps and Lamp Systems. Bridgelux LED Arrays are classified as
Risk Group 1 (Low Risk) when operated at or below their rated test current. Please use appropriate
precautions. It is important that employees working with LEDs are trained to use them safely.
CAUTION: RISK OF BURN
Do not touch the LED Array or resin area during operation. Allow the LED Array to cool for a sufficient
period of time before handling. The LED Array may reach elevated temperatures such that it can burn
skin when touched.
CAUTION: CHEMICAL EXPOSURE HAZARD
Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause
damage to the LED Array. Please consult Application Note AN11 for additional information.
Bridgelux RS Array Series Product Data Sheet DS25 (12/3/11)
Page 4 of 24
Case Temperature Measurement Point
A case temperature measurement point location is included on the top surface of the Bridgelux LED
Arrays. The location of this measurement point is indicated in the mechanical dimensions section of this
data sheet.
The purpose of this measurement point is to allow the user access to a measurement point closely linked
to the true case temperature on the back surface of the LED Array. Once the LED Array is installed, it is
challenging to measure the back surface of the array, or true case temperature. Measuring the top
surface of the product can lead to inaccurate results due to the poor thermal conductivity of the top layers
of the array such as the solder mask and other materials.
Bridgelux has provided the case temperature measurement location in a manner which closely ties it to
the true case temperature of the LED Array under steady state operation. Deviations between thermal
measurements taken at the point indicated and the back of the LED Array differ by less than 1°C,
providing a robust method to testing thermal operation once the product is installed.
Bridgelux RS Array Series Product Data Sheet DS25 (12/3/11)
Page 5 of 24
Quick Selection Guide
The following configurations are available:
Table 1: Selection Guide for RS Arrays
Typical
DC
Flux
Tcase
70ºC
Typical
Pulsed
Flux
Tj 25ºC
(lm)
Efficacy
(Typ at Tj
25ºC)
Test
Current
(mA)
Vf
(Typ)
(V)
Power
(Typ)
(W)
CCT CRI
(Nominal) (min)
Base Part Number
(lm/W)
(lm)
BXRA-27E4000-H-00
BXRA-27G4000-H-00
BXRA-27E7000-J-00
BXRA-27G7000-J-00
BXRA-30E4000-H-00
BXRA-30G4000-H-00
BXRA-30E7000-J-00
BXRA-30G7000-J-00
BXRA-35E4000-H-00
BXRA-35E7000-J-00
BXRA-40E4500-H-00
BXRA-40E7500-J-00
BXRA-50C5300-H-00
BXRA-50C9000-J-00
BXRA-56C5300-H-00
BXRA-56C9000-J-00
2700
2700
2700
2700
3000
3000
3000
3000
3500
3500
4000
4000
5000
5000
5600
5600
80
90
80
90
80
90
80
90
80
80
80
80
70
70
70
70
4450
3800
7050
6000
4725
4150
7500
6600
5100
8100
5400
8550
6000
9750
6000
9750
3980
3400
6190
5270
4230
3715
6580
5790
4560
7110
4830
7500
5370
8560
5370
8560
2100
2100
2800
2800
2100
2100
2800
2800
2100
2800
2100
2800
2100
2800
2100
2800
24.4
24.4
30.4
30.4
24.4
24.4
30.4
30.4
24.4
30.4
24.4
30.4
24.4
30.4
24.4
30.4
51
51
85
85
51
51
85
85
51
85
51
85
51
85
51
85
87
74
83
71
92
81
88
78
100
95
106
100
117
115
117
115
Bridgelux RS Array Series Product Data Sheet DS25 (12/3/11)
Page 6 of 24
Flux Characteristics
Table 2: Flux Characteristics
Minimum
Pulsed
Flux
Typical
Pulsed
Flux
Tj = 25ºC
(lm)
Typical
DC Flux
Test
Current
(mA)
ANSI
CCT
(K)
CRI
(min)
Color
Base Part Number
(4)
Tcase= 70ºC
(lm)
(2)
Tj = 25ºC
(lm)
(3)
(1)
BXRA-27E4000-H-00
BXRA-27G4000-H-00
BXRA-27E7000-J-00
BXRA-27G7000-J-00
BXRA-30E4000-H-00
BXRA-30G4000-H-00
BXRA-30E7000-J-00
BXRA-30G7000-J-00
BXRA-35E4000-H-00
BXRA-35E7000-J-00
BXRA-40E4500-H-00
BXRA-40E7500-J-00
BXRA-50C5300-H-00
BXRA-50C9000-J-00
BXRA-56C5300-H-00
BXRA-56C9000-J-00
80
90
80
90
80
90
80
90
80
80
80
80
70
70
70
70
3980
3400
6190
5270
4230
3715
6580
5790
4560
7110
4830
7500
5370
8560
5370
8560
4000
3400
6350
5400
4250
3750
6750
5950
4600
7300
4850
7700
5400
8800
5400
8800
4450
3800
7050
6000
4725
4150
7500
6600
5100
8100
5400
8550
6000
9750
6000
9750
2100
2100
2800
2800
2100
2100
2800
2800
2100
2800
2100
2800
2100
2800
2100
2800
2700
3000
Warm
White
3500
4000
5000
5600
Neutral
White
Cool
White
Notes for Table 2:
1. Bridgelux maintains a 7% tolerance of flux measurements.
2. Parts are tested in pulsed conditions, Tj = 25°C. Pulse width is 10 ms at rated test current.
3. Typical performance when driven at DC (direct current) test current with LED Array case
temperature maintained at 70°C, mounted to heat sink with thermal interface material. Please
contact a Bridgelux sales representative for additional details.
4. Typical R9 value for 90 CRI product options is 50.
5. Reference Table 7 and 8 for typical performance at other driver currents (including those
commonly available in the market).
Bridgelux RS Array Series Product Data Sheet DS25 (12/3/11)
Page 7 of 24
Optical Characteristics
Table 3: Optical Characteristics
Color Temperature
(CCT)
Typical
Center
Beam
Typical
Viewing
Angle
(Degrees)
2 θ1/2 [4]
[1], [2], [3]
ANSI
CCT
(K)
CRI
(min)
Color
Base Part Number
Candle
Power
(cd)
Min
Typ
Max
[5]
BXRA-27E4000-H-00
BXRA-27G4000-H-00
BXRA-27E7000-J-00
BXRA-27G7000-J-00
BXRA-30E4000-H-00
BXRA-30G4000-H-00
BXRA-30E7000-J-00
BXRA-30G7000-J-00
BXRA-35E4000-H-00
BXRA-35E7000-J-00
BXRA-40E4500-H-00
BXRA-40E7500-J-00
BXRA-50C5300-H-00
BXRA-50C9000-J-00
BXRA-56C5300-H-00
BXRA-56C9000-J-00
2580 K 2725 K 2870 K
2580 K 2725 K 2870 K
2580 K 2725 K 2870 K
2580 K 2725 K 2870 K
2870 K 3045 K 3220 K
2870 K 3045 K 3220 K
2870 K 3045 K 3220 K
2870 K 3045 K 3220 K
3220 K 3465 K 3710 K
3220 K 3465 K 3710 K
3700 K 4000 K 4250 K
3700 K 4000 K 4250 K
4745 K 5100 K 5310 K
4745 K 5100 K 5310 K
5310 K 5665 K 6020 K
5310 K 5665 K 6020 K
80
90
80
90
80
90
80
90
80
80
80
80
70
70
70
70
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
1420
1210
2240
1910
1500
1320
2380
2100
1620
2575
1710
1720
1910
3100
1910
3100
2700
3000
Warm
White
3500
4000
5000
5600
Neutral
White
Cool
White
Notes for Table 3:
1. Parts are tested in pulsed conditions, Tj = 25°C. Pulse width is 10 ms at rated test current.
2. Refer to Flux Characteristic Table for test current data.
3. Product is binned for color in x y coordinates.
4. Viewing angle is the off axis angle from the centerline where Iv is ½ of the peak value.
5. Center beam candle power is a calculated value based on lambertian radiation pattern at nominal
test current.
Bridgelux RS Array Series Product Data Sheet DS25 (12/3/11)
Page 8 of 24
Electrical Characteristics
Table 4: Electrical Characteristics
Forward Voltage Vf
(V)
Typical
Thermal
Resistance
Junction
to Case
Typical
[2]
Coefficient
of Forward
Voltage
Test
Current
(mA)
Color
Base Part Number
[1]
Min
Typ
Max
(mV/ºC)
∆Vf/∆Tj
(ºC/W) Rθj-c
BXRA-27E4000-H-00
BXRA-27G4000-H-00
BXRA-27E7000-J-00
BXRA-27G7000-J-00
BXRA-30E4000-H-00
BXRA-30G4000-H-00
BXRA-30E7000-J-00
BXRA-30G7000-J-00
BXRA-35E4000-H-00
BXRA-35E7000-J-00
BXRA-40E4500-H-00
BXRA-40E7500-J-00
BXRA-50C5300-H-00
BXRA-50C9000-J-00
BXRA-56C5300-H-00
BXRA-56C9000-J-00
21.9
21.9
27.4
27.4
21.9
21.9
27.4
27.4
21.9
27.4
21.9
27.4
21.9
27.4
21.9
27.4
24.4
24.4
30.4
30.4
24.4
24.4
30.4
30.4
24.4
30.4
24.4
30.4
24.4
30.4
24.4
30.4
26.8
26.8
33.4
33.4
26.8
26.8
33.4
33.4
26.8
33.4
26.8
33.4
26.8
33.4
26.8
33.4
2100
2100
2800
2800
2100
2100
2800
2800
2100
2800
2100
2800
2100
2800
2100
2800
-8 to -24
-8 to -24
-10 to -30
-10 to -30
-8 to -24
-8 to -24
-10 to -30
-10 to -30
-8 to -24
-10 to -30
-8 to -24
-10 to -30
-8 to -24
-10 to -30
-8 to -24
-10 to -30
0.31
0.31
0.26
0.26
0.31
0.31
0.26
0.26
0.31
0.26
0.31
0.26
0.31
0.26
0.31
0.26
Warm
White
Neutral
White
Cool
White
Notes for Table 4:
1. Parts are tested in pulsed conditions, Tj = 25°C. Pulse width is 10 ms at rated test current.
2. Bridgelux maintains a tester tolerance of 0.10 V on forward voltage measurements.
Bridgelux RS Array Series Product Data Sheet DS25 (12/3/11)
Page 9 of 24
Absolute Minimum and Maximum Ratings
Table 5: Maximum Current and Reverse Voltage Ratings
Maximum Peak
Pulsed Current
(mA)
Maximum
Reverse Voltage
(Vr)
Maximum DC
Forward Current
(mA)
Color
Base Part Number
[1]
[2]
BXRA-27E4000-H-00
BXRA-27G4000-H-00
BXRA-27E7000-J-00
BXRA-27G7000-J-00
BXRA-30E4000-H-00
BXRA-30G4000-H-00
BXRA-30E7000-J-00
BXRA-30G7000-J-00
BXRA-35E4000-H-00
BXRA-35E7000-J-00
BXRA-40E4500-H-00
BXRA-40E7500-J-00
BXRA-50C5300-H-00
BXRA-50C9000-J-00
BXRA-56C5300-H-00
BXRA-56C9000-J-00
3000
3000
3750
3750
3000
3000
3750
3750
3000
3750
3000
3750
3000
3750
3000
3750
4000
4000
5000
5000
4000
4000
5000
5000
4000
5000
4000
5000
4000
5000
4000
5000
-40 V
-40 V
-50 V
-50 V
-40 V
-40 V
-50 V
-50 V
-40 V
-50 V
-40 V
-50 V
-40 V
-50 V
-40 V
-50 V
Warm
White
Neutral
White
Cool
White
Notes for Table 5:
1. Bridgelux recommends a maximum duty cycle of 10% when operating LED Arrays at the
maximum peak pulsed current specified.
2. Light emitting diodes are not designed to be driven in reverse voltage.
Table 6: Maximum Ratings
Parameter
Maximum Rating
LED Junction Temperature
Storage Temperature
150°C
-40°C to +105°C
Operating Case Temperature
Soldering Temperature
105°C
350°C or lower for a maximum of 3.5 seconds
Bridgelux RS Array Series Product Data Sheet DS25 (12/3/11)
Page 10 of 24
Typical Performance at Alternative Drive Currents
The Bridgelux LED Arrays are tested and binned against the specifications shown in Tables 2, 3 and 4.
Customers also have options to drive the LED Arrays at alternative drive currents dependent on the
specific application. The typical performance at any drive current can be derived from the flux vs. current
characteristics shown in Figures 5 and 6 and from the current vs. voltage characteristics shown in Figures
10 and 11. The typical performance at common drive currents is also summarized in Tables 7 and 8.
Table 7: Typical Product Performance at Alternative Drive Currents
Typical
Pulsed
Luminous
Flux фv (lm),
Tj=25°C
Typical
Forward
Voltage
Typical DC
Luminous
Flux фv (lm),
Tcase=70°C
Forward
Current
(mA)
ANSI
CCT
(K)
Color
Part Number
CRI
[2]
Vf
(V)
2660
3270
3980
2270
2790
3400
4910
5820
6190
4180
4960
5270
2830
3480
4230
2480
3095
3715
5220
6190
6580
4590
5440
5790
2970
23.4
24.0
24.4
23.4
24.0
24.4
29.2
29.8
30.7
29.2
29.8
30.7
23.4
24.0
24.4
23.4
24.0
24.4
29.2
29.8
30.7
29.2
29.8
30.7
1400
1750
BXRA-27E4000-H-00
BXRA-27G4000-H-00
BXRA-27E7000-J-00
BXRA-27G7000-J-00
BXRA-30E4000-H-00
BXRA-30G4000-H-00
BXRA-30E7000-J-00
BXRA-30G7000-J-00
80
90
80
90
80
90
80
90
3640
4450
2530
3110
3800
5590
6630
7050
4755
5640
6000
3150
3870
4725
2770
3400
4150
5960
7060
7500
5240
6210
6600
2100(1)
1400
1750
2100(1)
2700
1750
2100
2800(1)
1750
2100
2800(1)
Warm
White
1400
1750
2100(1)
1400
1750
2100(1)
3000
1750
2100
2800(1)
1750
2100
2800(1)
Bridgelux RS Array Series Product Data Sheet DS25 (12/3/11)
Page 11 of 24
Typical Performance at Alternative Drive Currents (continued)
Table 8: Typical Product Performance at Alternative Drive Currents
Typical
Pulsed
Luminous
Flux фv
(lm),
Typical
Forward
Voltage
Typical DC
Luminous
Flux фv (lm),
Tcase=70°C
Forward
Current
(mA)
ANSI
CCT
(K)
Color
Part Number
CRI
[2]
Vf
(V)
Tj=25°C
3130
3840
4560
5640
6680
7110
3210
3940
4830
5955
7060
7500
3590
4400
5370
6795
8050
8560
3590
4400
5370
6795
8050
8560
3500
4300
5100
6430
7620
8100
3610
4435
5400
6790
8050
8550
4000
4925
6000
7740
9170
9750
4000
4920
6000
7740
9170
9750
23.4
24.0
24.4
29.2
29.8
30.7
23.4
24.0
24.4
29.2
29.8
30.7
23.4
24.0
24.4
29.2
29.8
30.7
23.4
24.0
24.4
29.2
29.8
30.7
1400
1750
BXRA-35E4000-H-00
BXRA-35E7000-J-00
BXRA-40E4500-H-00
BXRA-40E7500-J-00
BXRA-50C5300-H-00
BXRA-50C9000-J-00
BXRA-56C5300-H-00
BXRA-56C9000-J-00
80
80
80
80
70
70
70
70
2100(1)
Warm
White
3500
4000
5000
5600
1750
2100
2800(1)
1400
1750
2100(1)
Neutral
White
1750
2100
2800(1)
1400
1750
2100(1)
1750
2100
2800(1)
Cool
White
1400
1750
2100(1)
1750
2100
2800(1)
Notes for Table 7 and 8:
1. Product is tested and binned at the specified drive current.
2. Operating these LED Arrays at or below the drive currents listed in Tables 7 and 8, with a case
temperature maintained at or below 85°C, will enable the average lumen maintenance projection
outlined earlier in this Product Data Sheet.
Bridgelux RS Array Series Product Data Sheet DS25 (12/3/11)
Page 12 of 24
Mechanical Dimensions
Figure 1: Drawing for RS Arrays
Notes for Figure 1:
1. Slots are for M2.5, M3 or #4 screws.
2. Solder pads are labeled “+” and “-“ to denote positive and negative, respectively.
3. It is not necessary to provide electrical connections to both sets of solder pads. Either set of
solder pads (6.35 x 2.03 mm rectangular pads or 3.50 mm tapered square pads) may be used
depending on application specific design requirements.
4. Drawings are not to scale.
5. Drawing dimensions are in millimeters.
6. Bridgelux recommends four tapped holes for mounting screws – refer to product Application Note
AN11 for recommended spacing of holes.
7. Unless otherwise specified, tolerances are 0.10 mm.
8. Refer to product Application Notes AN10 and AN11 for product handling, mounting and heat sink
recommendations.
9. The optical center of the LED Array is defined by the mechanical center of the array.
10. Bridgelux maintains a flatness of 0.25 mm across the mounting surface of the array. Refer to
Application Notes AN10 and AN11 for product handling, mounting and heat sink
recommendations.
Bridgelux RS Array Series Product Data Sheet DS25 (12/3/11)
Page 13 of 24
Typical Radiation Pattern
Figure 2: Typical Spatial Radiation Pattern
Figure 3: Typical Polar Radiation Pattern
Bridgelux RS Array Series Product Data Sheet DS25 (12/3/11)
Page 14 of 24
Wavelength Characteristics at Rated Test Current, Tj=25°C
Figure 4: Typical Color Spectrum
Bridgelux RS Array Series Product Data Sheet DS25 (12/3/11)
Page 15 of 24
Typical Relative Luminous Flux vs. Current, Tj=25°C
Figure 5: Typical Flux vs. Current
For 2100mA Products
2.00
1.80
1.60
1.40
1.20
1.00
0.80
0.60
0.40
0.20
0.00
BXRA-xxx4000-H-00
BXRA-xxx4500-H-00
BXRA-xxx5300-H-00
0
500
1000
1500
2000
2500
3000
3500
4000
Current (mA)
Figure 6: Typical Flux vs. Current
For 2800mA Products
BXRA-xxx7000-J-00
BXRA-xxx7500-J-00
BXRA-xxx9000-J-00
Current (mA)
Bridgelux RS Array Series Product Data Sheet DS25 (12/3/11)
Page 16 of 24
Typical Light Output Characteristics vs. Temperature
Figure 7: Typical Flux vs. Junction Temperature
Neutral White
Warm White
Cool White
Bridgelux RS Array Series Product Data Sheet DS25 (12/3/11)
Page 17 of 24
Typical Chromaticity Characteristics vs. Temperature
Figure 8: Typical ccy Shift vs. Junction Temperature
Neutral White
Warm White
Cool White
Figure 9: Typical ccx Shift vs. Junction Temperature
Neutral White
Warm White
Cool White
Bridgelux RS Array Series Product Data Sheet DS25 (12/3/11)
Page 18 of 24
Forward Current Characteristics
Figure 10: Current vs. Voltage
BXRA-xxx4000-H-00, BXRA-xxx4500-H-00, BXRA-xxx5300-H-00
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0.0
MIN Vf
Tc=25°C
MAX Vf
Tc=25°C
TYP Vf
Tc=25°C
MIN Vf
Tc=70°C
MIN
MAX
TYP
MINTc=70
18.0 19.0 20.0 21.0 22.0 23.0 24.0 25.0 26.0 27.0 28.0 29.0 30.0 31.0 32.0
Forward Voltage (V)
Figure 11: Current vs. Voltage
BXRA-xxx7000-J-00, BXRA-xxx7500-J-00, BXRA-xxx9000-J-00
5.0
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0.0
MIN Vf
Tc=25°C
MAX Vf
Tc=25°C
MIN Vf
Tc=70°C
TYP Vf
Tc=25°C
MIN
MAX
TYP
MINTc=70
22.0 23.0 24.0 25.0 26.0 27.0 28.0 29.0 30.0 31.0 32.0 33.0 34.0 35.0 36.0 37.0 38.0
Forward Voltage (V)
Bridgelux RS Array Series Product Data Sheet DS25 (12/3/11)
Page 19 of 24
Color Binning Information
Figure 12: Graph of Warm White Test Bins in xy Color Space
3000K
0.44
0.43
0.42
0.41
0.4
3SDCM
T3
S3
R3
Q3
R4
P3
3500K
2700K
3SDCM
T4
N3
S4
3SDCM
0.39
0.38
0.37
0.36
0.35
Q4
P4
N4
0.38
0.4
0.42
0.44
0.46
0.48
X
Table 9: Warm White xy Bin Coordinates and Associated Typical CCT
ANSI
CCT
(K)
ANSI
CCT
(K)
ANSI
CCT
(K)
Bin
Code
Bin
Code
Bin
Code
X
Y
X
Y
X
Y
0.4223
0.4299
0.4431
0.4345
0.4147
0.4223
0.4345
0.4260
0.4345
0.4431
0.4562
0.4468
0.4260
0.4345
0.4468
0.3990
0.4165
0.4213
0.4033
0.3814
0.3990
0.4033
0.3854
0.4033
0.4213
0.4260
0.4077
0.3854
0.4033
0.4077
0.4468
0.4562
0.4688
0.4585
0.4373
0.4468
0.4585
0.4483
0.4585
0.4688
0.4813
0.4703
0.4483
0.4585
0.4703
0.4077
0.4260
0.4290
0.4104
0.3893
0.4077
0.4104
0.3919
0.4104
0.4290
0.4319
0.4132
0.3919
0.4104
0.4132
0.3943
0.3996
0.4148
0.4083
0.3889
0.3943
0.4083
0.4018
0.4083
0.4148
0.4299
0.4223
0.4018
0.4083
0.4223
0.3853
0.4015
0.4090
0.3921
0.3690
0.3853
0.3921
0.3752
0.3921
0.4090
0.4165
0.3990
0.3752
0.3921
0.3990
Q3
Q4
R3
R4
3000
3000
3000
S3
S4
T4
T3
2700
2700
2700
N4
N3
P3
P4
3500
3500
3500
3000
3000
2700
2700
3500
3500
0.4373
0.4413
0.4325
0.4274
0.4350
0.3893
0.4107
0.4075
0.3958
0.3984
0.4593
0.4656
0.4573
0.4510
0.4583
0.3944
0.4174
0.4154
0.4032
0.4049
0.4147
0.4148
0.4047
0.4012
0.4098
0.3814
0.4000
0.3950
0.3841
0.3883
X3
(3SDCM)
X3
(3SDCM)
X3
(3SDCM)
Bridgelux RS Array Series Product Data Sheet DS25 (12/3/11)
Page 20 of 24
Color Binning Information (continued)
Figure 13: Graph of Neutral White Test Bins in xy Color Space
M3
4000K
3SDCM
L3
M4
L4
Z
Table 10: Neutral White xy Bin Coordinates and Associated Typical CCT
ANSI
CCT (K)
Bin Code
X
Y
0.3703
0.3736
0.3871
0.3828
0.3670
0.3703
0.3828
0.3784
0.3828
0.3871
0.4006
0.3952
0.3784
0.3828
0.3952
0.3898
0.3881
0.3791
0.3769
0.3845
0.3726
0.3874
0.3959
0.3803
0.3578
0.3726
0.3803
0.3647
0.3803
0.3959
0.4044
0.3880
0.3647
0.3803
0.3880
0.3716
0.3879
0.3823
0.3724
0.3770
L3
4000
L4
M3
M4
4000
4000
4000
4000
X3
(3SDCM)
Bridgelux RS Array Series Product Data Sheet DS25 (12/3/11)
Page 21 of 24
Color Binning Information (continued)
Figure 14: Graph of Cool White Test Bins in xy Color Space
0.38
0.37
0.36
0.35
0.34
0.33
0.32
H3
G3
H4
F3
G4
E3
F4
E4
0.31
0.32
0.33
0.34
0.35
0.36
X
Table 11: Cool White xy Bin Coordinates and Associated Typical CCT
ANSI
CCT
(K)
ANSI
CCT
(K)
Bin
Code
Bin
Code
X
Y
X
Y
0.3376 0.3616
0.3464 0.3688
0.3452 0.3558
0.3371 0.3493
0.3371 0.3493
0.3452 0.3558
0.3441 0.3428
0.3366 0.3369
0.3464 0.3688
0.3215 0.3353
0.3293 0.3423
0.3292 0.3539
0.3207 0.3462
0.3222 0.3243
0.3294 0.3306
0.3293 0.3423
0.3215 0.3353
0.3292 0.3539
0.3293 0.3423
0.3371 0.3493
0.3376 0.3616
0.3294 0.3306
0.3366 0.3369
0.3371 0.3493
0.3293 0.3423
G3
5000
5000
5000
5000
E3
E4
F3
F4
5600
5600
5600
5600
G4
H3
H4
0.3551
0.376
0.3533 0.3624
0.3452 0.3558
0.3452 0.3558
0.3533 0.3624
0.3515 0.3487
0.3441 0.3428
Bridgelux RS Array Series Product Data Sheet DS25 (12/3/11)
Page 22 of 24
Design Resources
Bridgelux has developed a comprehensive set of application notes and design resources to assist
customers in successfully designing with Bridgelux LED Array products. Included below is a list of
available resources which can be downloaded from the Bridgelux web site under the Design Resources
section. These documents are updated regularly as new information becomes available, including
complimentary infrastructure products such as commercially available secondary optics and electronic
driver solutions.
Application Notes
•
•
•
•
•
•
AN10: Effective Thermal Management of Bridgelux LED Arrays
AN11: Assembly Considerations for Bridgelux LED Arrays
AN12: Electrical Drive Considerations for Bridgelux LED Arrays
AN14: Reliability Data Sheet for Bridgelux LED Arrays
AN15: Reflow Soldering of Bridgelux LED Arrays
AN16: Optical Considerations for Bridgelux LED Arrays
Optical Source Models
Optical source models and ray set files are available for all Bridgelux LED Array products, and can be
downloaded directly from the Bridgelux web site. The list below contains the formats currently available.
If you require a specific format not included in this list, please contact your Bridgelux sales representative
for assistance.
•
•
•
•
•
•
•
•
•
Zemax
ASAP
IESNA
LightTools
LucidShape
OPTIS SPEOS
PHOTOPIA
TracePro
Radiant Imaging Source Model
3D CAD Models
Three dimensional CAD models depicting the product outline of all Bridgelux LED Arrays are available in
both SAT and STEP formats. These CAD files can be downloaded directly from the Bridgelux web site.
Bridgelux RS Array Series Product Data Sheet DS25 (12/3/11)
Page 23 of 24
About Bridgelux
Bridgelux is a leading developer and manufacturer of technologies and solutions transforming
the $40 billion global lighting industry into a $100 billion market opportunity. Based in
Livermore, California, Bridgelux is a pioneer in solid-state lighting (SSL), expanding the market
for light-emitting diode (LED) technologies by driving down the cost of LED lighting systems.
Bridgelux’s patented light source technology replaces traditional technologies (such as
incandescent, halogen, fluorescent and high intensity discharge lighting) with integrated, solid-
state lighting solutions that enable lamp and luminaire manufacturers to provide high
performance and energy-efficient white light for the rapidly growing interior and exterior lighting
markets, including street lights, commercial lighting and consumer applications. With more than
550 patent applications filed or granted worldwide, Bridgelux is the only vertically integrated
LED manufacturer and developer of solid-state light sources that designs its solutions
specifically for the lighting industry.
For more information about the company, please visit www.bridgelux.com
© 2011 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice.
Bridgelux RS Array Series Product Data Sheet DS25 (12/3/11)
Page 24 of 24
相关型号: