C201240060 [ETC]

;
C201240060
型号: C201240060
厂家: ETC    ETC
描述:

文件: 总3页 (文件大小:63K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Timers  
Symmetrical Recycler  
Types C 101, C 201, C 108, C 208, C 111, C 211, C 118, C 218  
• Time ranges: 0.15 s to 600 s  
• Automatic start  
• C .0.: Starts with OFF-time  
C .1.: Starts with ON-time  
• Knob-adjustable time within range  
• Oscillator-controlled time circuit  
• Repeatability deviation: 1%  
• Output: 10 A SPDT or 8 A DPDT relay  
• Plug-in type module  
• Scantimer housing  
• LED-indication for relay on  
• AC or DC power supply  
Product Description  
Mono-function, plug-in, sym- time period first. This eco- Function  
metrical, ON/OFF miniature nomical relay is often used in Output  
recyclers up to 600 s (10 min) lighting systems such as ad- Type  
Ordering Key  
C 108 024 600  
covering 3 individual time vertising signs, etc.  
ranges. Optional ON- or OFF-  
Power supply  
Time range  
Type Selection, OFF-Time Period First  
Plug  
Output Time ranges  
Supply: 24 VAC/DC  
Supply: 120 VAC  
Supply: 220 VAC  
Circular  
8 pin  
SPDT  
0.15- 6 s  
1.5 - 60 s  
15 - 600 s  
C 108 024 006  
C 108 024 060  
C 108 024 600  
C 108 120 006  
C 108 120 060  
C 108 120 600  
C 108 220 006  
C 108 220 060  
C 108 220 600  
Circular  
11 pin  
0.15- 6 s  
1.5 - 60 s  
15 - 600 s  
C 101 024 006  
C 101 024 060  
C 101 024 600  
C 101 120 006  
C 101 120 060  
C 101 120 600  
C 101 220 006  
C 101 220 060  
C 101 220 600  
Circular  
8 pin  
DPDT  
0.15- 6 s  
1.5 - 60 s  
15 - 600 s  
C 208 024 006  
C 208 024 060  
C 208 024 600  
C 208 120 006  
C 208 120 060  
C 208 120 600  
C 208 220 006  
C 208 220 060  
C 208 220 600  
Circular  
11 pin  
0.15- 6 s  
1.5 - 60 s  
15 - 600 s  
C 201 024 006  
C 201 024 060  
C 201 024 600  
C 201 120 006  
C 201 120 060  
C 201 120 600  
C 201 220 006  
C 201 220 060  
C 201 220 600  
Type Selection, ON-Time Period First  
Plug  
Output Time ranges  
Supply: 24 VAC/DC  
Supply: 120 VAC  
Supply: 220 VAC  
Circular  
8 pin  
SPDT  
0.15- 6 s  
1.5 - 60 s  
15 - 600 s  
C 118 024 006  
C 118 024 060  
C 118 024 600  
C 118 120 006  
C 118 120 060  
C 118 120 600  
C 118 220 006  
C 118 220 060  
C 118 220 600  
Circular  
11 pin  
0.15- 6 s  
1.5 - 60 s  
15 - 600 s  
C 111 024 006  
C 111 024 060  
C 111 024 600  
C 111 120 006  
C 111 120 060  
C 111 120 600  
C 111 220 006  
C 111 220 060  
C 111 220 600  
Circular  
8 pin  
DPDT  
0.15- 6 s  
1.5 - 60 s  
15 - 600 s  
C 218 024 006  
C 218 024 060  
C 218 024 600  
C 218 120 006  
C 218 120 060  
C 218 120 600  
C 218 220 006  
C 218 220 060  
C 218 220 600  
Circular  
11 pin  
0.15- 6 s  
1.5 - 60 s  
15 - 600 s  
C 211 024 006  
C 211 024 060  
C 211 024 600  
C 211 120 006  
C 211 120 060  
C 211 120 600  
C 211 220 006  
C 211 220 060  
C 211 220 600  
Specifications are subject to change without notice (25.10.99)  
1
C 108, C 208, C 118, C 218  
C 101, C 201, C 111, C 211  
Time Specifications  
Time ranges  
0.15- 6 s  
1.5 - 60 s  
15.0 - 600 s  
Repeatability deviation  
Time variation  
Within rated power supply  
and ambient temperature  
1%  
0.05%/V  
0.2%/°C  
Time range accuracy  
0 to +10% on max.  
min. actual time min.  
set time  
Reset  
Time and/or relay  
Power supply interruption min.  
250 ms  
Output Specifications  
C 108, C 101, C 118, C 111  
C 208, C 201, C 218, C 211  
DPDT relay  
Output  
Basic electrical insulation  
SPDT relay  
250 VAC (rms) (contact/electronics)  
250 VAC (rms) (contacts/elec., contact/contact)  
Contact ratings (AgCdO)  
µ (micro gap)  
µ (micro gap)  
Resistive loads  
AC 1 10 A/250 VAC (2500 VA)  
DC 1 1 A/250 VDC (250 W)  
or  
8 A/250 VAC (2000 VA)  
0.4 A/250 VDC (100 W)  
4 A/25 VDC (100 W)  
2.5 A/230 VAC  
10 A/25 VDC (250 W)  
Small inductive loads AC 15 2.5 A/230 VAC  
DC 13 5 A/24 VDC  
5 A/24 VDC  
Mechanical life  
Electrical life  
30 x 106 operations  
AC 1 2.5 x 105 operations (at max. load)  
30 x 106 operations  
2.5 x 105 operations (at max. load)  
Operating frequency  
7200 operations/h  
7200 operations/h  
Insulation voltages  
Rated insulation voltage  
2.0 kVAC (rms) (contact/electronics)  
2.0 kVAC (rms) (contact/electronics)  
Rated transient protection volt. 4 kV (1.2/50 µs) (contact/electronics) (IEC 60664)  
4 kV (1.2/50 µs) (contact/electronics) (IEC 60664)  
General Specifications  
Supply Specifications  
Power supply AC types  
Installation cat. III (IEC 60664) Indication for  
Rated operational voltage  
Output ON  
LED. red  
through pins 2 & 10  
or pins 2 & 7  
220  
220 VAC + 15/- 20%,  
45 to 65 Hz  
120 VAC + 15/- 20%,  
45 to 65 Hz  
24 VAC + 15/- 20%,  
45 to 65 Hz  
10 ms  
Environment  
Degree of protection  
Pollution degree  
Operating temperature  
Storage temperature  
IP 20 B  
2 (IEC 60664)  
-20° to +50°C (-4° to +122°F)  
-50° to +85°C (-58° to +185°F)  
120  
024  
Weight  
Approvals  
85 g  
Dropout tolerance  
Rated insulation voltage  
UL, CSA  
None  
Rated transient protection volt. 4 kV (1.2/50 µs) @ 220 VAC  
2.5 kV (1.2/50 µs) @ 120 VAC  
800 V (1.2/50 µs) @ 24 VAC  
(line/neutral)  
Power supply DC type  
Rated operational volt. 024  
Installation cat. III (IEC 60664)  
24 VDC + 15/- 20% (pin 2 pos.)  
Rated insulation voltage  
None  
Rated transient protection volt. 800 V (1.2/50 µs)  
Consumption  
AC supply  
DC supply  
60 mA @ 50 Hz/70 mA @ 60 Hz  
1 W  
Power ON delay  
Power OFF delay  
200 ms  
250 ms  
2
Specifications are subject to change without notice (25.10.99)  
C 108, C 208, C 118, C 218  
C 101, C 201, C 111, C 211  
Mode of Operation  
Wiring Diagrams  
Example 2  
Example 1  
(Types C .1.)  
(Types C .0.)  
ON-time period first  
The relay operates and the  
time period starts immediately  
when power supply is applied.  
OFF-time period first  
The time period starts when  
power supply is applied.  
At the end of the first set time  
period, the relay operates. At  
the end of the second set  
time period (equal to the first),  
the relay releases.  
At the end of the first set time  
period, the relay releases. At  
the end of the second set  
time period (equal to the first),  
the relay operates again.  
Power supply  
C 108, C 118  
C 208, C 218  
Power supply  
C 101, C 111  
C 201, C 211  
This sequence is repeated un-  
til power supply is interrupted.  
If power supply is disconnect-  
ed, the time is reset and a re-  
covery period of 250 ms sho-  
uld be allowed before the re-  
cycler is ready for reactiva-  
tion.  
This sequence is repeated  
with equal intervals until pow-  
er supply is interrupted. If  
power supply is interrupted,  
the time is reset and a recove-  
ry period of 250 ms should be  
allowed before the recycler is  
ready for reactivation.  
Accessories  
Time Setting  
Knob-adjustable on scale in  
seconds.  
Sockets◊  
S 408, S 411  
HF  
SM 13  
BB4  
PL 1  
Hold down spring◊  
Mounting rack  
Socket cover  
Potentiometer lock  
For further information refer to "Accessories".  
Operation Diagram  
Power supply  
Example 1: Relay on  
Example 2: Relay on  
Specifications are subject to change without notice (25.10.99)  
3

相关型号:

C2012A0R5J100NB

HOTTECH CHIP CERAMIC CAPACITORS
HOTTECH

C2012A0R5J100NT

HOTTECH CHIP CERAMIC CAPACITORS
HOTTECH

C2012A0R5J100SB

HOTTECH CHIP CERAMIC CAPACITORS
HOTTECH

C2012A0R5J100ST

HOTTECH CHIP CERAMIC CAPACITORS
HOTTECH

C2012A0R5J101NB

HOTTECH CHIP CERAMIC CAPACITORS
HOTTECH

C2012A0R5J101NT

HOTTECH CHIP CERAMIC CAPACITORS
HOTTECH

C2012A0R5J101SB

HOTTECH CHIP CERAMIC CAPACITORS
HOTTECH

C2012A0R5J101ST

HOTTECH CHIP CERAMIC CAPACITORS
HOTTECH

C2012A0R5J250NB

HOTTECH CHIP CERAMIC CAPACITORS
HOTTECH

C2012A0R5J250NT

HOTTECH CHIP CERAMIC CAPACITORS
HOTTECH

C2012A0R5J250SB

HOTTECH CHIP CERAMIC CAPACITORS
HOTTECH