C201240060 [ETC]
;型号: | C201240060 |
厂家: | ETC |
描述: |
|
文件: | 总3页 (文件大小:63K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Timers
Symmetrical Recycler
Types C 101, C 201, C 108, C 208, C 111, C 211, C 118, C 218
• Time ranges: 0.15 s to 600 s
• Automatic start
• C .0.: Starts with OFF-time
C .1.: Starts with ON-time
• Knob-adjustable time within range
• Oscillator-controlled time circuit
• Repeatability deviation: ≤ 1%
• Output: 10 A SPDT or 8 A DPDT relay
• Plug-in type module
• Scantimer housing
• LED-indication for relay on
• AC or DC power supply
Product Description
Mono-function, plug-in, sym- time period first. This eco- Function
metrical, ON/OFF miniature nomical relay is often used in Output
recyclers up to 600 s (10 min) lighting systems such as ad- Type
Ordering Key
C 108 024 600
covering 3 individual time vertising signs, etc.
ranges. Optional ON- or OFF-
Power supply
Time range
Type Selection, OFF-Time Period First
Plug
Output Time ranges
Supply: 24 VAC/DC
Supply: 120 VAC
Supply: 220 VAC
Circular
8 pin
SPDT
0.15- 6 s
1.5 - 60 s
15 - 600 s
C 108 024 006
C 108 024 060
C 108 024 600
C 108 120 006
C 108 120 060
C 108 120 600
C 108 220 006
C 108 220 060
C 108 220 600
Circular
11 pin
0.15- 6 s
1.5 - 60 s
15 - 600 s
C 101 024 006
C 101 024 060
C 101 024 600
C 101 120 006
C 101 120 060
C 101 120 600
C 101 220 006
C 101 220 060
C 101 220 600
Circular
8 pin
DPDT
0.15- 6 s
1.5 - 60 s
15 - 600 s
C 208 024 006
C 208 024 060
C 208 024 600
C 208 120 006
C 208 120 060
C 208 120 600
C 208 220 006
C 208 220 060
C 208 220 600
Circular
11 pin
0.15- 6 s
1.5 - 60 s
15 - 600 s
C 201 024 006
C 201 024 060
C 201 024 600
C 201 120 006
C 201 120 060
C 201 120 600
C 201 220 006
C 201 220 060
C 201 220 600
Type Selection, ON-Time Period First
Plug
Output Time ranges
Supply: 24 VAC/DC
Supply: 120 VAC
Supply: 220 VAC
Circular
8 pin
SPDT
0.15- 6 s
1.5 - 60 s
15 - 600 s
C 118 024 006
C 118 024 060
C 118 024 600
C 118 120 006
C 118 120 060
C 118 120 600
C 118 220 006
C 118 220 060
C 118 220 600
Circular
11 pin
0.15- 6 s
1.5 - 60 s
15 - 600 s
C 111 024 006
C 111 024 060
C 111 024 600
C 111 120 006
C 111 120 060
C 111 120 600
C 111 220 006
C 111 220 060
C 111 220 600
Circular
8 pin
DPDT
0.15- 6 s
1.5 - 60 s
15 - 600 s
C 218 024 006
C 218 024 060
C 218 024 600
C 218 120 006
C 218 120 060
C 218 120 600
C 218 220 006
C 218 220 060
C 218 220 600
Circular
11 pin
0.15- 6 s
1.5 - 60 s
15 - 600 s
C 211 024 006
C 211 024 060
C 211 024 600
C 211 120 006
C 211 120 060
C 211 120 600
C 211 220 006
C 211 220 060
C 211 220 600
Specifications are subject to change without notice (25.10.99)
1
C 108, C 208, C 118, C 218
C 101, C 201, C 111, C 211
Time Specifications
Time ranges
0.15- 6 s
1.5 - 60 s
15.0 - 600 s
Repeatability deviation
Time variation
Within rated power supply
and ambient temperature
≤ 1%
≤ 0.05%/V
≤ 0.2%/°C
Time range accuracy
0 to +10% on max.
min. actual time ≤ min.
set time
Reset
Time and/or relay
Power supply interruption min.
250 ms
Output Specifications
C 108, C 101, C 118, C 111
C 208, C 201, C 218, C 211
DPDT relay
Output
Basic electrical insulation
SPDT relay
250 VAC (rms) (contact/electronics)
250 VAC (rms) (contacts/elec., contact/contact)
Contact ratings (AgCdO)
µ (micro gap)
µ (micro gap)
Resistive loads
AC 1 10 A/250 VAC (2500 VA)
DC 1 1 A/250 VDC (250 W)
or
8 A/250 VAC (2000 VA)
0.4 A/250 VDC (100 W)
4 A/25 VDC (100 W)
2.5 A/230 VAC
10 A/25 VDC (250 W)
Small inductive loads AC 15 2.5 A/230 VAC
DC 13 5 A/24 VDC
5 A/24 VDC
Mechanical life
Electrical life
≥ 30 x 106 operations
AC 1 ≥ 2.5 x 105 operations (at max. load)
≥ 30 x 106 operations
≥ 2.5 x 105 operations (at max. load)
Operating frequency
≤ 7200 operations/h
≤ 7200 operations/h
Insulation voltages
Rated insulation voltage
≥ 2.0 kVAC (rms) (contact/electronics)
≥ 2.0 kVAC (rms) (contact/electronics)
Rated transient protection volt. 4 kV (1.2/50 µs) (contact/electronics) (IEC 60664)
4 kV (1.2/50 µs) (contact/electronics) (IEC 60664)
General Specifications
Supply Specifications
Power supply AC types
Installation cat. III (IEC 60664) Indication for
Rated operational voltage
Output ON
LED. red
through pins 2 & 10
or pins 2 & 7
220
220 VAC + 15/- 20%,
45 to 65 Hz
120 VAC + 15/- 20%,
45 to 65 Hz
24 VAC + 15/- 20%,
45 to 65 Hz
≥ 10 ms
Environment
Degree of protection
Pollution degree
Operating temperature
Storage temperature
IP 20 B
2 (IEC 60664)
-20° to +50°C (-4° to +122°F)
-50° to +85°C (-58° to +185°F)
120
024
Weight
Approvals
85 g
Dropout tolerance
Rated insulation voltage
UL, CSA
None
Rated transient protection volt. 4 kV (1.2/50 µs) @ 220 VAC
2.5 kV (1.2/50 µs) @ 120 VAC
800 V (1.2/50 µs) @ 24 VAC
(line/neutral)
Power supply DC type
Rated operational volt. 024
Installation cat. III (IEC 60664)
24 VDC + 15/- 20% (pin 2 pos.)
Rated insulation voltage
None
Rated transient protection volt. 800 V (1.2/50 µs)
Consumption
AC supply
DC supply
60 mA @ 50 Hz/70 mA @ 60 Hz
1 W
Power ON delay
Power OFF delay
≤ 200 ms
≥ 250 ms
2
Specifications are subject to change without notice (25.10.99)
C 108, C 208, C 118, C 218
C 101, C 201, C 111, C 211
Mode of Operation
Wiring Diagrams
Example 2
Example 1
(Types C .1.)
(Types C .0.)
ON-time period first
The relay operates and the
time period starts immediately
when power supply is applied.
OFF-time period first
The time period starts when
power supply is applied.
At the end of the first set time
period, the relay operates. At
the end of the second set
time period (equal to the first),
the relay releases.
At the end of the first set time
period, the relay releases. At
the end of the second set
time period (equal to the first),
the relay operates again.
Power supply
C 108, C 118
C 208, C 218
Power supply
C 101, C 111
C 201, C 211
This sequence is repeated un-
til power supply is interrupted.
If power supply is disconnect-
ed, the time is reset and a re-
covery period of 250 ms sho-
uld be allowed before the re-
cycler is ready for reactiva-
tion.
This sequence is repeated
with equal intervals until pow-
er supply is interrupted. If
power supply is interrupted,
the time is reset and a recove-
ry period of 250 ms should be
allowed before the recycler is
ready for reactivation.
Accessories
Time Setting
Knob-adjustable on scale in
seconds.
Sockets◊
S 408, S 411
HF
SM 13
BB4
PL 1
Hold down spring◊
Mounting rack
Socket cover
Potentiometer lock
For further information refer to "Accessories".
Operation Diagram
Power supply
Example 1: Relay on
Example 2: Relay on
Specifications are subject to change without notice (25.10.99)
3
相关型号:
©2020 ICPDF网 联系我们和版权申明