CNR-14D201K [ETC]
METAL OXIDE VARISTORS TRANSIENT / SURGE ABSORBERS; 金属氧化物压敏电阻瞬态/突波吸收器型号: | CNR-14D201K |
厂家: | ETC |
描述: | METAL OXIDE VARISTORS TRANSIENT / SURGE ABSORBERS |
文件: | 总24页 (文件大小:1416K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Transient/Surge Absorbers
Transient Voltage Surge Suppressors
Metal Oxide Varistors
Transient/Surge Absorbers
1
Transient/Surge Absorbers
Transient Voltage Surge Suppressors
CeNtRa Varistor
Varistor are voltage dependent, nonlinear device which have an
electrical behavior similar to back-to-back zender diodes.
CNR series zinc oxide varistor are nonlinear resistors, consisting
main of zinc oxide and several kinds of metal oxide additive.
They are bilateral and symmetrical V-I characteristics curve and
unparalleled large peak current capability are used for absorption
of transient voltage, suppression of pulse noise and circuit
voltage stabilization.
Features
•
•
•
•
Fast response
Excellent voltage ratio
High stabilization for circuit voltage
Unparalleled absorption for transient voltage
characteristics
•
Bilateral and symmetrical V-I characteristics
curve
Applications
•
Surge Protection in consumer electronics
-
-
-
-
-
industrial electronics
telephone and telecommunication systems
automobile equipments
measuring and controller systems
electronic home appliances
•
•
•
Absorption of switching surge form various kinds of relays and electro-magnetic valves.
Electrostatic discharge an spike noise suppression.
Protection of various kinds of transistors, diodes, ICs, thyristors, triac semiconductors, and etc.
Related Standards
•
UL1414, UL1449, (2nd Edition), CSA, VDE
Explanation of Part Numbers
CNR
D
Common Code
CeNtRa
Metal Oxide Varistor
Surge Absorber
Element Dia
Varistor Voltage
Examples
Tolerance
Type
D
05
07
10
14
20
Ø5.0mm
Ø7.0mm
Ø10.0mm
Ø14.0mm
Ø20.0mm
K
± 10%
2
2
x
2
x
0
or customer
specjal
requirement
22
100
1
=
=
22V
2
22
101
220V
2
Transient/Surge Absorbers
Transient Voltage Surge Suppressors
Specifications
•
•
•
•
•
•
•
Varistor Voltage Range …………………………….……18 TO 1800Vdc
Peak Current For 8/20 µs Current Wave………..…100 TO 6500A
Energy Range For 10/1000 µs Current Wave…… 0.4 TO 625 Joul
Storage Temperature Range ………………………….-40 TO +1250C
Operation Ambient Temperature Range …………- 40 TO 850C
Typical Response Time …………………………………< 25ns
Insulation Resistance ……………………………………>1000MΩ
Device Ratings and Characteristics
Maximum
Peak Rated
Current Power
(8/20µs)
Part No.
Maximum
Allowable
Voltage
Varistor
Voltage
(@1mA)
Clamping Voltage Maximum
Typical
Capacitance
(@1KHz)
@ Test Current
(8/20µs)
Energy
10/1000µs
Standards
Device
Marking
ACrms(V) DC(V)
Min. Vb(Vdc) Max. Vc(V)
Ip(A)
1
2.5
5
10
20
(J)
0.4
0.9
2.1
4.0
11.0
(A)
100
250
500
1000
2000
(W)
0.01
0.02
0.05
0.10
0.20
(pF)
1600
3800
16000
25000
40000
ϩʳʳ
ϩʳʳ
ϩʳʳ
ϩʳʳ
ϩʳʳ
CNR-05D180K
CNR-07D180K
CNR-10D180K
CNR-14D180K
CNR-20D180K
44
42
11
14
17
20
25
30
14
18
22
26
31
38
14.4
18.7
23.0
29.5
35
18
22
27
33
39
47
21.6
26.0
31.1
36.5
39
39
39
ʳ
ʳ
ʳ
ϩʳʳ
ϩʳʳ
ϩʳʳ
ϩʳʳ
ϩʳʳ
CNR-05D220K
CNR-07D220K
CNR-10D220K
CNR-14D220K
CNR-20D220K
51
47
43
43
43
1
2.5
5
10
20
0.5
1.1
2.5
5.0
14.0
100
250
500
1000
2000
0.01
0.02
0.05
0.10
0.20
1500
3600
11000
20000
30000
ϩʳʳ
ϩʳ
ϩʳ
ϩʳ
ϩʳ
CNR-05D270K
CNR-07D270K
CNR-10D270K
CNR-14D270K
CNR-20D270K
60
53
53
53
53
1
2.5
5
10
20
0.6
1.4
3.0
6.0
18.0
100
250
500
1000
2000
0.01
0.02
0.05
0.10
0.20
1450
3400
8000
16000
24500
ϩʳ
ϩʳ
ϩʳ
ϩʳ
ϩʳ
ʳ
CNR-05D330K
CNR-07D330K
CNR-10D330K
CNR-14D330K
CNR-20D330K
73
65
65
65
65
1
2.5
5
10
20
0.8
1.7
4.0
7.5
23.0
100
250
500
1000
2000
0.01
0.02
0.05
0.10
0.20
1400
2900
6300
12200
20000
ϩʳ
ϩʳ
ϩʳ
ϩʳ
ϩʳ
ʳ
CNR-05D390K
CNR-07D390K
CNR-10D390K
CNR-14D390K
CNR-20D390K
46
43
43
43
43
86
77
77
77
77
1
2.5
5
10
20
0.9
2.1
4.6
8.6
26.0
100
250
500
1000
2000
0.01
0.02
0.05
0.10
0.20
700
1600
5200
7000
13800
ϩʳ
ϩʳ
ϩʳ
ϩʳ
ϩʳ
CNR-05D470K
CNR-07D470K
CNR-10D470K
CNR-14D470K
CNR-20D470K
55
52
52
52
52
104
93
93
93
93
1
2.5
5
10
20
1.1
2.5
5.5
10.0
33.0
100
250
500
1000
2000
0.01
0.02
0.05
0.10
0.20
650
1550
4600
6750
13500
42
Note: 1. O5D series Varistor voltage test current by Dc 0.1 mA
3
Transient/Surge Absorbers
Transient Voltage Surge Suppressors
Device Ratings and Characteristics
Maximum
Peak Rated
Current Power
(8/20µs)
Part No.
Maximum
Allowable
Voltage
Varistor
Voltage
(@1mA)
Clamping Voltage Maximum
Typical
Capacitance
(@1KHz)
@ Test Current
(8/20µs)
Energy
10/1000µs
Standards
Device
Marking
ACrms(V) DC(V)
Min. Vb(Vdc) Max. Vc(V)
Ip(A)
1
2.5
5
10
20
(J)
1.3
3.1
7.0
11.0
41.0
(A)
100
250
500
1000
2000
(W)
0.01
0.02
0.05
0.10
0.20
(pF)
600
1500
3750
6500
12200
ϩʳ
ϩʳ
ϩʳ
ϩʳ
ϩʳ
CNR-05D560K
CNR-07D560K
CNR-10D560K
CNR-14D560K
CNR-20D560K
66
62
62
62
62
123
110
110
110
110
35
40
45
56
50
56
68
ʳ
ʳ
ϩʳ
ϩʳ
ϩʳ
ϩʳ
ϩʳ
CNR-05D680K
CNR-07D680K
CNR-10D680K
CNR-14D680K
CNR-20D680K
80
75
75
75
75
150
135
135
135
135
1
2.5
5
10
20
1.6
3.6
8.2
14.0
46.0
100
250
500
1000
2000
0.01
0.02
0.05
0.10
0.20
580
1200
2800
5500
11500
61
ϩʳʳʳʳʳʳʳʳʳʳʳϨʳ
ϩʳʳʳʳʳʳʳʳʳʳʳϨʳ
ϩʳʳʳʳʳʳʳʳʳʳʳϨʳ
ϩʳʳʳʳʳʳʳʳʳʳʳϨʳ
ϩʳʳʳʳʳʳʳʳʳʳʳϨʳ
ʳ
CNR-05D820K
CNR-07D820K
CNR-10D820K
CNR-14D820K
CNR-20D820K
145
135
135
135
135
5
2.5
5.5
12.0
22.0
38.0
400
0.10
0.25
0.40
0.60
1.0
310
860
1920
4300
8200
10
25
50
100
1200
2500
4500
6500
50
65
74
82
90
ϩʳʳʳʳʳʳʳʳʳʳʳϨʳ
ϩʳʳʳʳʳʳʳʳʳʳʳϨʳ
ϩʳʳʳʳʳʳʳʳʳʳʳϨʳ
ϩʳʳʳʳʳʳʳʳʳʳʳϨʳ
ϩʳʳʳʳʳʳʳʳʳʳʳϨʳ
CNR-05D101K
CNR-07D101K
CNR-10D101K
CNR-14D101K
CNR-20D101K
175
165
165
165
165
5
3.0
6.5
15.0
28.0
45.0
400
0.10
0.25
0.40
0.60
1.0
290
750
1800
3500
8000
10
25
50
100
1200
2500
4500
6500
60
85
90
100
120
150
180
200
110
132
165
198
225
ʳ
ʳ
ʳ
ʳ
ϩʳʳʳʳʳʳʳʳʳʳʳϨʳ
ϩʳʳʳʳʳʳʳʳʳʳʳϨʳ
ϩʳʳʳʳʳʳʳʳʳʳʳϨʳ
ϩʳʳʳʳʳʳʳʳʳʳʳϨʳ
ϩʳʳʳʳʳʳʳʳʳʳʳϨʳ
CNR-05D121K
CNR-07D121K
CNR-10D121K
CNR-14D121K
CNR-20D121K
210
200
200
200
200
5
4.0
7.8
18.0
32.0
55.0
400
0.10
0.25
0.40
0.60
1.0
270
530
1500
2500
5500
10
25
50
100
1200
2500
4500
6500
75
100
125
150
170
108
135
162
185
ϩʳʳʳʳʳʳʳʳʳʳʳϨʳ
ϩʳʳʳʳʳʳʳʳʳʳʳϨʳ
ϩʳʳʳʳʳʳʳʳʳʳʳϨʳ
ϩʳʳʳʳʳʳʳʳʳʳʳϨʳ
ϩʳʳʳʳʳʳʳʳʳʳʳϨʳ
CNR-05D151K
CNR-07D151K
CNR-10D151K
CNR-14D151K
CNR-20D151K
260
250
250
250
250
5
4.8
9.7
22.0
40.0
70.0
400
0.10
0.25
0.40
0.60
1.0
240
410
1200
2100
4200
10
25
50
100
1200
2500
4500
6500
95
ϩʳʳʳʳʳʳʳʳʳʳʳϨ
ʳ
CNR-05D181K
CNR-07D181K
CNR-10D181K
CNR-14D181K
CNR-20D181K
325
300
300
300
300
5
5.9
400
0.10
0.25
0.40
0.60
1.0
140
300
620
1250
2500
ϩʳʳʳʳʳʳʳʳʳʳʳϨʳ
10
25
50
100
11.7
27.0
50.0
85.0
1200
2500
4500
6500
ϩʳʳʳʳʳʳʳʳʳʳʳϨ
ϩʳʳʳʳʳʳʳʳʳʳʳϨ
ʳ
ʳ
115
130
ϩʳʳʳʳʳʳʳʳʳʳʳϨʳ
ꢀʳϩʳϡʳϨʳ
CNR-05D201K
CNR-07D201K
CNR-10D201K
CNR-14D201K
CNR-20D201K
355
340
340
340
340
5
6.5
400
0.10
0.25
0.40
0.60
1.0
120
250
570
1150
2300
ꢀʳϩʳϡʳϨ
ʳ
10
25
50
100
13.0
30.0
57.0
95.0
1200
2500
4500
6500
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨ
ꢀʳϩʳϡʳϨ
ʳ
Note: 1. O5D series Varistor voltage test current by Dc 0.1 mA
4
Transient/Surge Absorbers
Transient Voltage Surge Suppressors
Device Ratings and Characteristics
Maximum
Peak Rated
Current Power
(8/20µs)
Part No.
Maximum
Allowable
Voltage
Varistor
Voltage
(@1mA)
Clamping Voltage Maximum
Typical
Capacitance
(@1KHz)
@ Test Current
(8/20µs)
Energy
10/1000µs
Standards
Device
Marking
ACrms(V) DC(V)
Min. Vb(Vdc) Max. Vc(V)
Ip(A)
5
10
25
50
(J)
7.0
14.0
32.0
60.0
100.0
(A)
400
1200
2500
4500
6500
(W)
0.10
0.25
0.40
0.60
1.0
(pF)
110
250
560
1100
2200
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨ
CNR-05D221K
CNR-07D221K
CNR-10D221K
CNR-14D221K
CNR-20D221K
380
360
140
150
175
195
210
230
250
275
180
200
225
250
275
230
320
350
198
216
247
270
297
324
351
387
220
240
270
300
330
360
390
430
242
264
303
330
363
396
429
473
360
360
360
100
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨ
CNR-05D241K
CNR-07D241K
CNR-10D241K
CNR-14D241K
CNR-20D241K
415
395
395
395
395
5
8.0
15.0
35.0
63.0
108.0
400
0.10
0.25
0.40
0.60
1.0
110
240
550
1050
2200
10
25
50
100
1200
2500
4500
6500
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨ
CNR-05D271K
CNR-07D271K
CNR-10D271K
CNR-14D271K
CNR-20D271K
475
455
455
455
455
5
8.5
18.0
40.0
70.0
127.0
400
0.10
0.25
0.40
0.60
1.0
100
220
530
1000
2100
10
25
50
100
1200
2500
4500
6500
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨ
CNR-05D301K
CNR-07D301K
CNR-10D301K
CNR-14D301K
CNR-20D301K
505
500
500
500
500
5
9.0
20.0
42.0
73.0
150.0
400
0.10
0.25
0.40
0.60
1.0
100
190
500
900
1800
10
25
50
100
1200
2500
4500
6500
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨ
CNR-05D331K
CNR-07D331K
CNR-10D331K
CNR-14D331K
CNR-20D331K
600
550
550
550
550
5
10.0
25.0
47.0
93.0
163.0
400
0.10
0.25
0.40
0.60
1.0
90
180
450
850
1750
10
25
50
100
1200
2500
4500
6500
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨ
CNR-05D361K
CNR-07D361K
CNR-10D361K
CNR-14D361K
CNR-20D361K
320
595
595
595
595
5
10.0
25.0
47.0
93.0
163.0
400
0.10
0.25
0.40
0.60
1.0
80
170
450
800
1700
10
25
50
100
1200
2500
4500
6500
ꢀʳϩʳϡʳϨ
ʳ
CNR-05D391K
CNR-07D391K
CNR-10D391K
CNR-14D391K
CNR-20D391K
675
650
650
650
650
5
12.0
25.0
60.0
100.0
180.0
400
0.10
0.25
0.40
0.60
1.0
80
160
430
800
1400
ꢀʳϩʳϡʳϨʳ
10
25
50
100
1200
2500
4500
6500
ꢀʳϩʳϡʳϨ
ꢀʳϩʳϡʳϨ
ꢀʳϩʳϡʳϨ
ʳ
ʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨ
ꢀʳϩʳϡʳϨʳ
CNR-05D431K
CNR-07D431K
CNR-10D431K
CNR-14D431K
CNR-20D431K
745
710
710
710
710
5
13.0
28.0
65.0
115.0
190.0
400
0.10
0.25
0.40
0.60
1.0
70
150
400
650
1350
ʳ
10
25
50
100
1200
2500
4500
6500
ꢀʳϩʳϡʳϨ
ꢀʳϩʳϡʳϨ
ʳ
Note: 1. O5D series Varistor voltage test current by Dc 0.1 mA
5
Transient/Surge Absorbers
Transient Voltage Surge Suppressors
Device Ratings and Characteristics
Maximum
Peak Rated
Current Power
(8/20µs)
Part No.
Maximum
Allowable
Voltage
Varistor
Voltage
(@1mA)
Clamping Voltage Maximum
Typical
Capacitance
(@1KHz)
@ Test Current
(8/20µs)
Energy
10/1000µs
Standards
Device
Marking
ACrms(V) DC(V)
Min. Vb(Vdc) Max. Vc(V)
Ip(A)
5
10
25
50
(J)
(A)
400
1200
2500
4500
6500
(W)
0.10
0.25
0.40
0.60
1.0
(pF)
70
130
300
550
1200
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨ
CNR-05D471K
CNR-07D471K
CNR-10D471K
CNR-14D471K
CNR-20D471K
810
775
15.0
30.0
70.0
125.0
220.0
300
320
350
385
420
385
410
460
505
560
423
459
504
558
612
470
510
560
620
680
517
561
616
682
748
825
775
775
775
100
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨ
CNR-05D511K
CNR-07D511K
CNR-10D511K
CNR-14D511K
CNR-20D511K
880
845
845
845
845
5
15.0
30.0
70.0
125.0
220.0
400
0.10
0.25
0.40
0.60
1.0
65
120
260
450
1050
10
25
50
100
1200
2500
4500
6500
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨ
CNR-05D561K
CNR-07D561K
CNR-10D561K
CNR-14D561K
CNR-20D561K
940
915
915
915
915
5
15.0
30.0
70.0
125.0
220.0
400
0.10
0.25
0.40
0.60
1.0
65
10
25
50
100
1200
2500
4500
6500
120
200
400
850
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨ
CNR-05D621K
CNR-07D621K
CNR-10D621K
CNR-14D621K
CNR-20D621K
1050
1025
1025
1025
1025
5
15.0
30.0
70.0
125.0
220.0
400
0.10
0.25
0.40
0.60
1.0
65
10
25
50
100
1200
2500
4500
6500
120
170
350
570
ϡʳʳʳʳʳʳʳʳʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨ
CNR-05D681K
CNR-07D681K
CNR-10D681K
CNR-14D681K
CNR-20D681K
1150
1120
1120
1120
1120
5
15.0
30.0
70.0
130.0
230.0
400
0.10
0.25
0.40
0.60
1.0
60
10
25
50
100
1200
2500
4500
6500
110
160
350
550
ʳϡʳʳʳʳʳʳʳʳʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨ
CNR-05D751K
CNR-07D751K
CNR-10D751K
CNR-14D751K
CNR-20D751K
1290
1240
1240
1240
1240
5
15.0
33.0
75.0
143.0
255.0
400
0.10
0.25
0.40
0.60
1.0
60
10
25
50
100
1200
2500
4500
6500
100
150
330
530
460
485
615
640
675
702
750
780
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨ
CNR-07D781K
CNR-10D781K
CNR-14D781K
CNR-20D781K
1290
1290
1290
1290
10
25
50
37.0
80.0
148.0
265.0
1200
2500
4500
6500
0.25
0.40
0.60
1.0
90
150
330
500
858
902
100
ꢀʳϩʳϡʳϨ
ꢀʳϩʳϡʳϨ
ʳ
ʳ
CNR-07D821K
CNR-10D821K
CNR-14D821K
CNR-20D821K
1355
1355
1355
1355
10
25
50
40.0
85.0
157.0
282.0
1200
2500
4500
6500
0.25
0.40
0.60
1.0
90
150
330
500
510
550
670
745
738
819
820
910
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨ
100
ꢀʳϩʳϡʳϨ
ꢀʳϩʳϡʳϨ
ꢀʳϩʳϡʳϨ
CNR-10D911K
CNR-14D911K
CNR-20D911K
1500
25
50
100
93.0
175.0
310.0
2500
4500
6500
0.40
0.60
1.0
140
300
480
1001 1500
1500
Note: 1. O5D series Varistor voltage test current by Dc 0.1 mA
6
Transient/Surge Absorbers
Transient Voltage Surge Suppressors
Device Ratings and Characteristics
Maximum
Peak Rated
Current Power
(8/20µs)
Part No.
Maximum
Allowable
Voltage
Varistor
Voltage
(@1mA)
Clamping Voltage Maximum
Typical
Capacitance
(@1KHz)
@ Test Current
(8/20µs)
Energy
10/1000µs
Standards
Device
Marking
ACrms(V) DC(V)
Min. Vb(Vdc) Max. Vc(V)
1650
Ip(A)
25
50
(J)
(A)
(W)
0.40
0.60
1.0
(pF)
140
300
460
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨʳ
ꢀʳϩʳϡʳϨ
CNR-10D102K
CNR-14D102K
CNR-20D102K
102.0
190.0
342.0
2500
4500
6500
625
825
900
1000 1100 1650
1650
100
ʳϡʳʳʳʳʳʳʳʳʳϨ
ʳϡʳʳʳʳʳʳʳʳʳϨʳ
ʳϡʳʳʳʳʳʳʳʳʳϨ
ʳ
CNR-10D112K
CNR-14D112K
CNR-20D112K
1815
1815
1815
25
50
100
115.0
213.0
383.0
2500
4500
6500
0.40
0.60
1.0
130
200
400
680
895
990
1100 1210
ʳ
CNR-14D182K
CNR-20D182K
2970
2970
50
100
337.0
625.0
4500
6500
0.60
1.0
150
250
1000
1465
1620
1800 1980
Note: 1. O5D series Varistor voltage test current by Dc 0.1 mA
Application Notes for UL Recognized Components
Related Standards
Standard No.
UL 1414
UL 1449(2nd Edition)
CSA
VDE
Accessories and
Parts for Electronic
Products
Across-The-Line
Components
Transient Voltage
Surge Suppressors
Varistors for use in
Electronic equipment
Title
File No.
E165143
E150709
LR109736-1
21557-4790-001
Ϧ
ϩ
ϡ
Ϩ
Symbols
Selection guide
1. Determine the necessary steady-state voltage (working voltage).
2. Establish the transient energy absorbed by the varistor.
3. Calculate the peak transient current through the varistor.
4. Determine power dissipation requirement.
5. Select a model to provide the required voltage-clampling characteristics.
7
Transient/Surge Absorbers
Transient Voltage Surge Suppressors
Tape and Reel Specifications
Series
Symbol
PARAMETER
Pictch of Componet
05D
12.7̈́.1.0
07D
10D
14D
25.4̈́.1.0
P
12.7̈́.1.0
12.7̈́.0.2
3.85̈́0.7
6.35̈́0.7
5.0̈́0.8
12.7̈́.1.0
P0
P1
P2
F
Feed Hole Pitch
12.7̈́.0.2
3.85̈́0.7
6.35̈́0.7
5.0̈́0.8
12.7̈́.0.2
2.6̈́0.7
12.7̈́.0.2
2.6̈́0.7
Feed Hole Center to Lead
Hole Center to Component Center
Lead to Lea Distance
Component Alignment
Tape Width
6.35̈́0.7
7.50̈́0.8
2.0 Max
6.35̈́0.7
7.50̈́0.8
2.0 Max
Ϧ
h
2.0 Max
2.0 Max
W
18.0+1.0
18.0-0.5
16.0̈́0.3
18.0+1.0
18.0-0.5
16.0̈́0.3
18.0+1.0
18.0-0.5
16.0̈́0.3
18.0+1.0
18.0-0.5
16.0̈́0.3
W0
W1
Hold Down Tape Width
Hole Position
9.0+0.75
9.0-0.50
0.5 Max
9.0+0.75
9.0-0.50
0.5 Max
9.0+0.75
9.0-0.50
0.5 Max
9.0+0.75
9.0-0.50
0.5 Max
W2
H
Hold Down Tape Position
Height from Tape Center to
Component Base
Seating Plane Height
Component Height
18.0+2.0
18.0-0.0
16.0̈́0.5
18.0+2.0
18.0-0.0
16.0̈́0.5
18.0+2.0
18.0-0.0
16.0̈́0.5
18.0+2.0
18.0-0.0
16.0̈́0.5
H0
H1
D0
t
29.0 Max
4.0̈́0.2
32.0 Max
4.0̈́0.2
36.0 Max
4.0̈́0.2
40.0 Max
4.0̈́0.2
Feed Hole Diameter
Total Tape Thickness
Length of Clipped Lead
0.7̈́0.2
0.7̈́0.2
0.7̈́0.2
0.7̈́0.2
L
11.0 Max
11.0 Max
11.0 Max0
11.0 Max
Order Information of Taped Reel
Standard Products
Tape Reel Straight
Lead
Tape Reel Crimped
Lead
Min. Q`ty
Q`ty / Inner Box Q`ty / Carton
CNR-05DXXXK
CNR-07DXXXK
CNR-10DXXXK
CNR-14DXXXK
CNR-05DXXXK-TRS CNR-05DXXXK-TRK
CNR-07DXXXK-TRS CNR-07DXXXK-TRK
CNR-10DXXXK-TRS CNR-10DXXXK-TRK
CNR-14DXXXK-TRS CNR-14DXXXK-TRK
2000/1500
2000/1500
1500/1000
1000/800
4000/3000
4000/3000
3000/2000
2000/1600
20000/15000
20000/15000
15000/10000
8000/6400
Note:
1. —2000/1500“ Packing in CNR-XXD180K to CNR-XXD271K are 2000 pcs, CNR-XXD301K to CNR-
XXD471K with 1500 pcs.
2. Packing unit in pcs.
8
Transient/Surge Absorbers
Transient Voltage Surge Suppressors
Packaging Specifications
Flat box
Reel
Dimensions
are in mm
Symbol
5D
7D
10D
Symbol
5D
7D
Approx. 35
10D
14D
55
A
B
C
55 max.
330 max.
340 max.
W
D
A
360 max
Approx. Ø 30
Approx. Ø 90
B
Order Information of Flat Box
Standard Products
Tape Box Straight
Lead
Tape Box Crimped
Lead
Max. Q`ty
Q`ty / Inner Box Q`ty / Carton
CNR-05DXXXK
CNR-07DXXXK
CNR-10DXXXK
CNR-05DXXXK-BTS CNR-05DXXXK-BTK
CNR-07DXXXK-BTS CNR-07DXXXK-BTK
CNR-10DXXXK-BTS CNR-10DXXXK-BTK
2000/1500
2000/1500
1500/1000
4000/3000
4000/3000
3000/2000
20000/15000
20000/15000
15000/10000
Note:
1. —2000/1500“ Packing in CNR-XXD180K to CNR-XXD271K are 2000 pcs, CNR-XXD301K to CNR-
XXD471K with 1500 pcs.
2. Packing unit in pcs.
Symbol
Series
05D
07D
10D
14D
A max. Varistor Voltage
V1mA(V)
18 to 270
13.0
13.0
7.5
15.0
15.0
9.0
19.5
20.5
14.0
22.5
23.5
17.5
360 to 470
D max.
K
1.2 ̈́ 0.4 1.2 ̈́ 0.4 1.4 ̈́ 0.4 1.4 ̈́ 0.4
5.0 ̈́ 1.0 5.0 ̈́ 1.0 7.5 ̈́ 1.0 7.5 ̈́ 1.0
W
0.6
0.6
0.8
0.8
Ø
d
T max. see standard specification table.
Order Information of Crimp Leads
Standard Products Cut Off Straight Lead
Cut Off Crimped Lead
Max. Q`ty
1000
1000
1000
1000
Q`ty / Box
25000
20000
20000
10000
Q`ty / Carton
50000
CNR-05DXXXK
CNR-07DXXXK
CNR-10DXXXK
CNR-14DXXXK
Note:
CNR-05DXXXK-TTS CNR-05DXXXK-TTK
CNR-07DXXXK-TTS CNR-07DXXXK-TTK
CNR-10DXXXK-TTS CNR-10DXXXK-TTK
CNR-14DXXXK-TTS CNR-14DXXXK-TTK
40000
40000
20000
1. Packing unit in pcs.
9
Transient/Surge Absorbers
Transient Voltage Surge Suppressors
Performance Characteristics Electrical
䯴 䯵
Characteristics
Test Methods/Description
Specifications
Environmental conditions under which every measuring is done
without
doubt on the measuring results. Unless specially specified,
temperature, relative humidity are 5 to 35 к, 45 to 85 % RH.
Ϋ
Standard Test Condition
varistor Voltage
The voltage between two terminals with the speciefied measuring
current CmA DC applied is called Vc or VcmA The measurement
shall be made as fast as pissible to avoid head affection.
The maximum sinusoidal RMS voltage or maximum DC voltage that
can be applied continuously in the specified environmental
temperature range
Maximum Allowable
Voltage
The maximum voltage between two terminals with the specified
standard impulse current (8/20µs) illustrated below applied.
Clamping Voltage
To meet the specified
value
The power that can be applied in the specified ambient
temperature.
Rated Power
The maximum energy within the varistor voltage change of ̈́ 10 %
when one impulse of 2 ms or 10/1000µs is applied.
The maximum current within the varistor voltage change of ̈́ 10 %
with the standard impulse current (8/20µs) applied two times with
an interval of 5 minutes.
The maximum current within the varistor voltage change of ̈́ 10 %
with the standard impulse current (8/20Ӵs) applied one time.
Maximum Energy
Maximum
2 times
peak Current
Withstanding
Surge
1 time
Current
Temperature Coefficient of
Varistor Voltage
-0.05и/к max
Capacitance
Dissipation Factor
The specified voltage shall be applied both terminals of the
specimen connected together and metal foil closely wrapped round
its body for 1 minute. Electrical breakdown shall be examined.
Withstanding Voltage
( Body Insulation )
Classification
Test Voltage
(AC)
No breakdown
(Nominal varistor voltage)
V0.1mA, V1mA, Љ330V
V0.1mA, V1mA, Ї330V
1000Vrms
1500Vrms
The change of Vc shall be measured after the impulse
listed below is applied 10000 times continuously with the interval
of 10 seconds at room temperature .
CNR-05D180K to CNR-05D680K
CNR-05D820K to CNR-05D471K
CNR-07D180K to CNR-07D680K
CNR-07D820K to CNR-07D471K
CNR-10D180K to CNR-10D680K
CNR-10D820K to CNR-10D112K
CNR-14D180K to CNR-14D680K
CNR-14D820K to CNR-14D182K
CNR-20D180K to CNR-20D680K
CNR-20D820K to CNR-20D471K
0.5A (2ms)
20A (8/20 µs)
18A (8/20 µs)
50A (8/20 µs)
50A (8/20 µs)
100A (8/20 µs)
75A (8/20 µs)
150A (8/20 µs)
120A (8/20 µs)
200A (8/20 µs)
5 Series
7 Series
ϦVcmA / VcmAЉ̈́10%
Impulse Life
10 Series
14 Series
20 Series
10
Transient/Surge Absorbers
Transient Voltage Surge Suppressors
Electrical
Characteristics
Test Methods/Description
Specifications
The change of Vc shall be measured after the impulse
listed below is applied 100000 times continuously with the interval
of 10 seconds at room temperature .
CNR-05D180K to CNR-05D680K
CNR-05D820K to CNR-05D471K
CNR-07D180K to CNR-07D680K
CNR-07D820K to CNR-07D471K
CNR-10D180K to CNR-10D680K
CNR-10D820K to CNR-10D112K
CNR-14D180K to CNR-14D680K
CNR-14D820K to CNR-14D182K
CNR-20D180K to CNR-20D680K
CNR-20D820K to CNR-20D471K
0.45A (2ms)
14A (8/20 µs)
12A (8/20 µs)
35A (8/20 µs)
35A (8/20 µs)
70A (8/20 µs)
45A (8/20 µs)
90A (8/20 µs)
55A (8/20 µs)
100A (8/20 µs)
5 Series
7 Series
ϦVcmA / VcmAЉ̈́10%
Impulse Life (II)
10 Series
14 Series
20 Series
Note: Varistor voltage change of forward direction shall be measured in the test of uni-pole surge life and DC
load life
(Mechanical)
Characteristics
Test Methods
Specifications
After gradually applying the force specified below and keeping the
unit fixed for the seconds, the terminal shall be visually examined
for any damage.
Robustness of
Terminations
(Tensile)
Terminal diameter
ø 0.6mm
Force
9.8 N (1.0Kgf)
9.8 N (1.0Kgf)
19.6 N (2.0Kgf)
ø 0.8mm
ø 1.0mm
The unit shall be secured with its terminal kept vertical and the
force specified below be applied in the axial direction. The terminal
shall gradually be bent by 900 in one direction, then 900 in the
opposite direction, and again back to the original position, The
damage of the terminal shall be visually examined.
No outstanding
damage
Robustness of
Terminations
(Bending)
Terminal diameter
ø 0.6mm
Force
4.9 N (0.5Kgf)
4.9 N (0.5Kgf)
9.8 N (1.0Kgf)
ø 0.8mm
ø 1.0mm
After repeadly applying a single harmonic vibration (amplitude:
0.75mm) double amplitude: 1.5mm with 1 minute vibration
frequency cycles (10 Hz to 55 Hz to 10 Hz) to each of three
perpendicular directions for 2 hours.thereafter There a f t e r, the
term i n a shall be visually examined.
Vibration
After dipping the terminals to a depth of approximately 3mm from
the body in a soldering bath of 235 ± 50C for 2±0.5 seconds, the
terminal shall be visually examined.
A p p roximately 95%
of the term i n a l s
shall be covered with
solder uniformly
Solderadilty
After each lead shall be dipped into a solder bath having a
temperature 260± 50C (3 series: 2 5 0± 50C ) to a point 2.0 to 2.5
mm from the body of the unit, using shieldig b o a rd (t=1.5mm),
be held there for specified time (3series: 3±1 s, 5 series: 5±1 s and
others: 10±1 s) hen stored at room temperature and humidity for 1
to 2 hours. The change of Vc and mechanical damages are
examined.
ϦVcmA/VcmAЉ±5%
No outstanding
damage
Resistance to
Soldering Heat
11
Transient/Surge Absorbers
Transient Voltage Surge Suppressors
(Environmental)
Characteristics
Test Methods
Specifications
The specimen shall be subjected to 125̈́20C for 1000 hours in a
thermostatic bath without load and then stored at room
temperatureand humidity for 1 to 2 hours. Thereafter, the change
of Vc shall be measured.
High Temperatuer
Storage/
Dry Heat
The specimen shall be subjected to 40 ̈́ 2 к, 90 to 95 %RH for
1000 hours load and then stored at room temperature and humidity
for one to two hours. Thereafter, the change of Vc shall be
measured.
Damp Heat/
Humidity
(Steady State)
The temperature cycle shown below shall be repeated five times
and then stored at room temperature and humidi ty for one to two
hours. The change of Vc and mechanical damage shall be
examined.
ϦVcmA/VcmAЉ±5%
Temperature(0C)
-40±3
Period (minutes)
Temperature
Cycle
Step
1
2
3
4
30±3
15±3
30±3
15±3
Room temperature
125±2
Room temperatuer
After being continuously applied the Maximum Allowable Voltage at
85 ̈́ 2к for 1000 hours. The specimen shall be stored at room
temperature and humidity for one to two hours Thereafter, the
change of Vc shall be measured.
High Temperatuer
Load/
Dry Heat Load
ϦVcmA/VcmAЉ±10%
The specimen shall be subjected to 40̈́2 к, 90 to 95 %RH and the
Maximum Allowable Voltage for 1000 hours and then stored at
room temperature and humidity for one to two hours. Thereafter,
the change of Vc shall be measured.
The specimen shall be subjected to -40̈́2к without load for 1000
hours and then stored at room temperature for one to two hours.
Thereafter, the change of Vc shall be measured.
Damp Heat Load/
Humidity Load
ϦVcmA/VcmAЉ±10%
ϦVcmA/VcmAЉ±5%
Low Temperatuer
Storage/Cold
12
Transient/Surge Absorbers
Transient Voltage Surge Suppressors
Impulse Life Time Rating Curves
2 times: 5 minutes interv a l
up to 10 times: 2 minutes interv a l
up to 106 times: 10 seconds interv a l
1
Transient/Surge Absorbers
Transient Voltage Surge Suppressors
Impulse Life Time Rating Curves
2 times: 5 minutes interv a l
up to 10 times: 2 minutes interv a l
up to 106 times: 10 seconds interv a l
14
Transient/Surge Absorbers
Transient Voltage Surge Suppressors
15
Transient/Surge Absorbers
Transient Voltage Surge Suppressors
16
Transient/Surge Absorbers
Transient Voltage Surge Suppressors
17
Transient/Surge Absorbers
Transient Voltage Surge Suppressors
18
Transient/Surge Absorbers
Transient Voltage Surge Suppressors
19
Transient/Surge Absorbers
Transient Voltage Surge Suppressors
20
Transient/Surge Absorbers
Transient Voltage Surge Suppressors
21
Transient/Surge Absorbers
Transient Voltage Surge Suppressors
Application Notes
1. Line protection
Selection of Ratings and Varistor Voltage
Line to Line
Line to line Protection Connections
Symbol
Line Voltage
DC 12V
Part Number
CNR- D220K
DC 24V
CNR- D390K
AC 100V
CNR- D201K, CNR- D221K
CNR- D241K*, CNR- D271K*
CNR- D241K, CNR- D271K*
CNR- D271K
CNR- D391K, CNR- D431K
CNR- D471K
CNR 1
AC 120V
AC 127V
AC 200V
AC 240V
AC 240V
CNR- D431K, CNR- D471K*
CNR- D431K, CNR- D471K*
CNR- D511K
AC 265V
AC 380V
AC 415V
AC 460V
AC 480V
CNR- D511K
CNR- D821K
CNR- D911K
CNR- D112K
CNR 3
CNR- D112K
Notes:
1. Maximum operating voltage shall be lower than Maximum allowable voltage of CNR at any time.
2. CNRs with * are recommended for single phase, 3 wire applications to withstand a temporary
overvoltage caused by unbanlance load.
Line to Line and Line to Ground Protection Connections
Selection of Ratings and Varistor Voltage
Line to Ground
Symbol
Line Voltage
Part Number
AC 100V to CNR- D431K, CNR- D471K
AC 220V
AC 240V
CNR- D431K, CNR- D471K
or CNR- D751K**
or higher Varistor Voltage
CNR- D182K***
CNR- D431K
CNR- D471K
or CNR- D751K**
or higher Varistor Voltage
CNR- D182K***
CNR 4
AC 240V
Notes:
1. When the 500V insulation resistance test of the circuits employing CNRs is conducted, CNR shall be
remove after getting approval from the customer, or CNR ** with the Maximum Allowable Voltage
exceeding to test voltage shall be used.
2. When the 1000V withstanding voltage test is conducted, CNR shall be remove after getting approval
from the customer according to the revelant regulations, or CNR ** with the Maximum Allowable
exceeding to the test voltage shall be used.
3. To avoid CNR failure caused by the ground fault, CNR with higher Varistor Voltage listed in the table
shall be used for the AC 120V line to ground application.
22
Transient/Surge Absorbers
Transient Voltage Surge Suppressors
Application examples
Protected circuit
Location
Indoor
Part Number
Protected circuit
Location
Indoor
Part Number
CNR-05D
CNR-07D
CNR-10D
CNR-10D
CNR-14D
CNR-20D
CNR-14D
CNR-20D
K
CNR-07D
CNR-10D
CNR-14D
CNR-05D
CNR-07D
CNR-10D
K
K
K
K
K
K
K
K
K
K
K
K
K
Communication
Measurments
Controls
Home
Appliances
Outdoor
Outdoor
Consumer
Industrial
Indoor,
Outdoor
CAUTION:
1. A surge excess of the specifie Maximunm Peak Current may cause short circuit or mechanical damage. The
following measures are recommended.
1) Location of the over current protector (circuit breaker or current fuse) shall be in the power line to the
circuit (Location A) or in series with CNR (Location B).
Part Number
Fuse Rating
CNR-05D
1 to 2 A
K
CNR-07D
2 to 3 A
K
CNR-10D
3 to 5 A
K
CNR-14D
3 to 10 A
K
CNR-20D
5 to 15 A
K
2) It is recommended that a fuse listed in the table shall be put in location A or B.
3) In case that CNR in used in line to ground, the ground fault circuit interrupter shall be applied in locate A or
thermally coupled fuse shall be applied in location C.
4) Fuse mounted Type K or Type P are available for CNR 1 and CNR 2 applications.
5) CNR shall not be used near the flamable materials.
2. When CNR is molded at end-user, molding resin materials shall be carefully selected, otherwise CNR`s long
term stability could degrade.
3. CNR shall not be used near heat generating device and free from direct sunlight. CNR shall be used with in
the specified Operating Temperature Range.
4. CNR shall be free from dust, metal powder, dew and sea wind. A protective box is recommended to prevent
the unit from those.
23
Transient/Surge Absorbers
Transient Voltage Surge Suppressors
2. Signal Line and telephone line surge protection
Signal line
Selection Example
Surge Protection of Signal Line
Signal Line Voltage
DC 48 V
Part Number
CNR- D820K
CNR- D201K
DC 100 V
Telephone Line
Surge Protection of Telephone Line
CNR
Part Number
CNR 1
CNR- D331K
CNR- D361K
CNR- D151K
CNR 2
Note:
CNR has relatively high capacitance, special attention shall be paid for it in high frequency circuits.
Caution:
Refer to the power line protection.
3. Switching surge protection, semiconductor protection and contact spark suppression
Selection examples
Voltage
DC 12V
DC 24V
DC 100V
DC 120V
Part Number
CNR- D220K
CNR- D390K
CNR- D151K
CNR- D221K
CNR- D241K
CNR- D271K
Note:
1. The Maximum Allowable Voltage to be higher than
maximum operation voltage at all time.
2. Energy handling capability of CNR shall be selected by
studying switching surge energy from the inductive
load.
Caution:
1. Refer to the mentioned caution describet in power line protection.
2. The relation between surge current repetition and CNR ratings is drawn in the CNR`s impulse life
characteristics.
3. Capacitor connection in parallel CNR is recommended for a contact spark suppression.
24
相关型号: