D04072080G-00 [ETC]

SPECIFICATION FOR APPROVAL; 产品规格书
D04072080G-00
型号: D04072080G-00
厂家: ETC    ETC
描述:

SPECIFICATION FOR APPROVAL
产品规格书

文件: 总14页 (文件大小:695K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
SUNON  
SPECIFICATION FOR APPROVAL  
CUSTOMER  
:
:
MOTOR TYPE  
DESCRIPTION  
DIMENSIONS  
M O D E L  
: MagLev Motor Fan  
: 40X40X20 mm  
: HA40201V4-000U-999  
: D04072080G-00  
:
SUNON SPEC. NO.  
CUSTOMER  
APPROVAL NO.  
APPROVED BY  
CUSTOMER  
:
(AUTHORIZED)  
SPEC.NO  
D04072080G-00  
01.07.2010  
1
ISSUE DATE  
Kiddy  
March  
Nancy  
07/17  
CHECKED  
APPROVED  
DRAWN  
Kelly  
EDITION  
REVISION DATE  
E.SPEC  
07.17.2012  
EM40330  
建準電機工業股份有限公司  
SUNONWEALTH ELECTRIC MACHINE INDUSTRY CO., LTD.  
NO. 30, LN. 296, XINYA RD., QIANZHEN DIST.,  
KAOHSIUNG CITY 80673, TAIWAN (R.O.C)  
URL:http://www.sunon.com  
TEL:886-7-8135888  
FAX:886-7-8230505/8230606/8231010  
E-mail: sunon@email.sunon.com.tw  
建 準 電 機  
SUNONWEALTH  
Page 1 of 14  
2012.07.23  
I. MODEL NUMBERING SYSTEM  
HA  
40 20  
V 4 - 000U  
1
- 999  
Speed  
Voltage  
Series Code  
X:Super High  
1: High  
0: 5VDC  
1: 12VDC  
2: 24VDC  
3: 36VDC  
4: 48VDC  
Function Code  
2: Medium  
3: Low  
Customer Code  
4: Super Low  
Bearing  
V: Vapo  
B: 2 Ball  
O: 1Ball  
S: Sleeve  
Size  
Thickness  
編碼  
尺寸(mm)  
編碼  
尺寸(mm)  
100~109  
110~119  
120~129  
130~139  
140~149  
150~159  
160~169  
170~179  
180~189  
190~199  
編碼  
K0~K9  
L0~L9  
M0~M9  
N0~N9  
P0~P9  
Q0~Q9  
R0~R9  
S0~S9  
T0~T9  
U0~U9  
尺寸(mm)  
200~209  
210~219  
220~229  
230~239  
240~249  
250~259  
260~269  
270~279  
280~289  
290~299  
編碼  
尺寸(mm)  
01~09  
10~19  
20~29  
30~39  
40~49  
50~59  
60~69  
70~79  
80~89  
90~99  
01~09  
10~19  
20~29  
30~39  
40~49  
50~59  
60~69  
70~79  
80~89  
90~99  
A0~A9  
B0~B9  
C0~C9  
D0~D9  
E0~E9  
F0~F9  
G0~G9  
H0~H9  
I0~I9  
V0~V9  
W0~W9  
X0~X9  
Y0~Y9  
Z0~Z9  
300~309  
310~319  
320~329  
330~339  
340~349  
J0~J9  
建 準 電 機  
SUNONWEALTH  
Page 2 of 14  
2012.07.23  
II. SPECIFICATION  
1. MECHANICAL CHARACTERISTIC  
2 phases, 4-poles Brushless DC motor  
MOTOR DESIGN  
Vapo bearing system  
BEARING SYSTEM  
DIMENSIONS  
See Page 6  
Thermoplastic PBT of UL 94V-0  
Thermoplastic PBT of UL 94V-0  
Counter-clockwise viewed from front of fan blade  
Diameter 4.3 mm in 4 holes  
30.6 g  
MATERIALS OF FRAME  
MATERIALS OF FAN BLADE  
DIRECTION OF ROTATION  
MOUNTING HOLES  
WEIGHT  
2. ELECTRIC CHARACTERISTIC  
RATED VOLTAGE  
12 VDC  
RATED CURRENT  
46 mA / Max. 53 mA  
0.6 WATTS / Max. 0.64 WATTS  
4.5~13.8 VDC  
RATED POWER CONSUMPTION  
OPERATING VOLTAGE RANGE  
STARTING VOLTAGE  
4.5 VDC (25 deg. C POWER ON/OFF)  
-10 to + 70 deg. C  
OPERATING TEMPERATURE RANGE  
STORAGE TEMPERATURE RANGE  
-40 to + 70 deg. C  
建 準 電 機  
SUNONWEALTH  
Page 3 of 14  
2012.07.23  
3. PERFORMANCE CHARACTERISTIC  
RATED SPEED  
4700 RPM ± 15% at rated voltage  
AIR FLOW  
5.5 CFM  
STATIC PRESSURE  
ACOUSTIC NOISE  
AIR FLOW V.S. PRESSURE  
0.08 Inch-H2O  
12.8 dB(A)  
See Page 5  
INSULATION CLASS  
UL Class A  
500M ohm at 500 VDC between internal stator and  
lead wire (+)  
INSULATION RESISTANCE  
PLASTIC HOUSING  
DIELECTRIC STRENGTH  
Applied AC 500 V for one minute or AC 600 V for 2  
Seconds between housing and lead wire (+)  
LIFE EXPECTANCY  
PROTECTION  
60,000 Hours at 40 deg. C, 65% humidity, 90% CL.  
Automatic Restart  
Note: In a situation where the fan is locked by an external  
force while the electricity is on, an increase in coil  
temperature will be prevented by temporarily turning off  
the electrical power to the motor. The fan will automatically  
restart when the locked rotor condition is released.  
Polarity Protection  
4. SAFETY  
SAFETY  
NO.  
UL  
CUR  
TUV  
CE  
E77551  
E77551  
建 準 電 機  
SUNONWEALTH  
Page 4 of 14  
2012.07.23  
MODEL : HA40201V4-000U-999  
PERFORMANCE CURVES  
STATIC  
PRESSURE  
mm-H2O  
Inch-H2O  
2.4  
1.6  
0.8  
0
0.08  
12 VDC  
0.04  
CFM  
0
0
2.5  
5
0.07  
0.14  
m3/min  
建 準 電 機  
SUNONWEALTH  
Page 5 of 14  
2012.07.23  
DIMENSIONS  
建 準 電 機  
SUNONWEALTH  
Page 6 of 14  
2012.07.23  
LABEL  
BLACK WORD  
COLOR:SILVER  
BLACK WORD  
COLOR:PANTONE 347C  
HA40201V4-000U-999  
BLACK WORD  
COLOR:SILVER  
0.6W  
DC12V  
ZP  
TUV  
Rheinland  
Product Safety  
GREEN  
DATE CODE  
建 準 電 機  
SUNONWEALTH  
Page 7 of 14  
2012.07.23  
III. OTHER SPECIFIED TESTING  
The following is a general description of certain tests that are performed on  
representative Sunon fans. Nothing in this document is intended to suggest that these  
tests are performed on every model of Sunon fan. Moreover, the descriptions that follow  
each test are meant only to provide a general explanation of each test. If you would like a  
more detailed explanation as to any test identified in this Section, Sunon can provide  
such an explanation upon request.  
1. DROP PROOF TEST  
Fans are packaged in a standard size shipping box and are dropped to the ground from  
certain heights and angles depending on the weight of the particular box.  
2. HUMIDITY PROOF TEST  
The fan is operated for 96 continuous hours in an environment with humidity of 90% to  
95% RH at 60°C 2°C.  
3. VIBRATION PROOF TEST  
Vibration with an amplitude 2mm and a frequency of 5-55-5hz is applied in all 3  
directions (X,Y,Z), in cycles of 1 hour each, for a total vibration time of 3hours.  
4. THERMAL CYCLING TEST  
The fan is operated in a testing chamber for 50 cycles. In each cycle, the temperature is  
gradually increased from -10°C to 70°C for 90 minutes, and subsequently operated at  
70°C for 120 minutes. The temperature is then gradually decreased from 70°C to -10°C  
for 90 minutes, and subsequently operated at -10°C for 120 minutes.  
5. SHOCK PROOF TEST  
100G of force is applied in the 3 directions (X,Y, and Z) for 2 milliseconds each.  
6. LIFE EXPECTANCY  
The “Life Expectancy” of SUNON fans is determined in SUNON’s reliability test  
laboratory by using temperature chambers. The “Life Expectancy” of this fan has not  
been evaluated for use in combination with any end application. Therefore, the Life  
Expectancy Test Reports (L10 and MTTF Report) that relate to this fan are only for  
reference.  
建 準 電 機  
SUNONWEALTH  
2012.07.23  
Page 8 of 14  
IV. CHARACTERISTIC DEFINITION  
The following is a general description of certain tests that are performed on  
representative Sunon fans in order to determine the specifications of the fan. Nothing in  
this document is intended to suggest that these tests are performed on every model of  
Sunon fan. Moreover, the descriptions that follow each test are meant only to provide a  
general explanation of each test. If you would like a more detailed explanation as to any  
test identified in this Section, Sunon can provide such an explanation upon request.  
1. ACOUSTICAL NOISE  
Measured in a semi-anechoic chamber with background noise level below 15dB(A).  
1 METER FROM MICROPHONE TO FAN INTAKE  
The fan is running in free air under shaft horizontal condition with the microphone at  
distance of one meter from the fan intake.  
2. INPUT POWER  
Measured after continuous 10 minute operation at rated voltage in clean air  
( STATIC PRESSURE=0), and at ambient temperature of 25 degrees C under shaft  
horizontal condition.  
3. RATED CURRENT  
Measured after continuous 10 minute operation at rated voltage in clean air  
( STATIC PRESSURE=0), and at ambient temperature of 25 degrees C under shaft  
horizontal condition.  
建 準 電 機  
SUNONWEALTH  
2012.07.23  
Page 9 of 14  
4. RATED SPEED  
Measured after continuous 10 minute operation at rated voltage in clean air  
( STATIC PRESSURE=0), and at ambient temperature of 25 degrees C under shaft  
horizontal condition.  
5. STARTING VOLTAGE  
Measured the voltage which enables to start the fan in the clean air (static pressure = 0 )  
by switching on at the voltage under shaft horizontal condition. It is not at continuously  
increasing voltage adjustment.  
6. LOCKED ROTOR CURRENT  
Measured immediately after the fan blade is locked.  
7. AIR FLOW AND STATIC PRESSURE  
The performance specification of air flow and static pressure shown in this specification for  
approval is measured using the exhaust method. A double chamber is used in accordance  
with AMCA 210 standard or DIN 24163 specification . The values are recorded when the  
fan speed has stabilized at rated voltage.  
8. INSULATION RESISTANCE  
1. PLASTIC HOUSING:  
(1) Measured between internal stator and lead wire(+).  
(2) Measured between housing and lead wire(+).  
2. ALUMINIUM HOUSING:  
Measured between internal stator and lead wire(+).  
9. DIELECTRIC STRENGTH  
Measure between housing and lead wire(+).  
建 準 電 機  
SUNONWEALTH  
2012.07.23  
Page 10 of 14  
V. NOTE  
.SAFETY  
1. DO NOT use or operate this fan in excess of the limitations set forth in this  
specification. SUNON is not be responsible for the non-performance of this fan  
and/or any damages resulting from its use, if it is not used or operated in accordance  
with the specifications.  
2. SUNON recommends adding a protection circuit to the product or application in  
which this fan is installed, such as a thermo-fuse, or current-fuse or thermo-protector.  
The failure to use such a device may result in smoke, fire, electric shock by  
insulation degradation in cases of motor lock, motor lead short circuit, overload, or  
over voltage, and/or other failure.  
3. SUNON recommends installing a protection device to the product or application in  
which this fan is installed if there is a possibility of reverse-connection between  
VDC (+) and GND (-). The failure to install such a device may result in smoke, fire,  
and/or destruction, although these conditions may not manifest immediately.  
4. This fan must be installed and used in compliance with all applicable safety  
standards and regulations.  
5. Use proper care when handling and/or installing this fan. Improper handling or  
installation of this fan may cause damage that could result in unsafe conditions.  
6. Use proper care during installation and/or wiring. Failure to use proper care may  
cause damage to certain components of the fan including, but not limited to, the coil  
and lead wires, which could result in smoke and/or fire.  
7. DO NOT use power or ground PWM to control the fan speed. If the fan speed needs  
to be adjusted, please contact Sunon to customize the product design for your  
application.  
8. For critical or extreme environments, including non stop operation, please contact  
Sunon and we will gladly provide assistance with your product selection to ensure an  
appropriate cooling product for your application.  
建 準 電 機  
SUNONWEALTH  
Page 11 of 14  
2012.07.23  
II. SPECIFICATION MODIFICATION  
1. SUNON offers engineering assistance on fan installation and cooling system design.  
2. All changes, modifications and/or revisions to the specifications, if any, are  
incorporated in the attached specifications.  
3. No changes, modifications and/or revisions to these specifications are effective absent  
agreement, by both Sunon and the customer, in writing.  
4. This fan will be shipped in accordance with the attached specification unless SUNON  
and the customer have agreed otherwise, in writing, as specificied in Paragraph 3,  
above.  
III. OTHER  
1. When building your device, please examine thoroughly any variation of EMC,  
temperature rise, life data, quality, etc. of this product by shock/drop/vibration testing,  
etc. If there are any problems or accidents in connection with this product, it should be  
mutually discussed and examined.  
2. Use proper care when handling this fan. Components such as fan holders or bearings  
may be damaged, if touched with fingers or other objects. Additionally, static  
electricity (ESD) may damage the internal circuits of the fan.  
3. DO NOT operate this fan in proximity to hazardous materials such as organic silicon,  
cyanogens, formalin, phenol, or corrosive gas environments including, but not limited  
to, H2S, SO2, NO2, or Cl2.  
4. SUNON recommends that you protect this fan from exposure to outside elements such  
as dust, condensation, humidity or insects. Exposure of this fan to outside elements such  
as dust, condensation, humidity or insects may affect its performance and may cause  
safety hazards. SUNON does not warrant against damage to the product caused by  
outside elements.  
5. This fan must be installed properly and securely. Improper mounting may cause harsh  
resonance, vibration, and noise.  
建 準 電 機  
SUNONWEALTH  
2012.07.23  
Page 12 of 14  
6. Fan guards may prevent injury during handling or installation of the fan and are  
available for sale with this fan.  
7. Unless otherwise noted, all testing of this fan is conducted at 25°C ambient temperature  
and sixty-five percent (65%) relative humidity.  
8. DO NOT store this fan in an environment with high humidity. This fan must be stored  
in accordance with the attached specifications regarding storage temperature. If this  
fan is stored for more than 6 months, SUNON recommends functional testing before  
using.  
9. SUNON reserves the right to use components from multiple sources at its discretion.  
The use of components from other sources will not affect the specifications as  
described herein.  
10. The “Life Expectancy” of this fan has not been evaluated for use in combination with  
any end application. Therefore, the Life Expectancy Test Reports (L10 and MTTF  
Report) that relate to this fan are only for reference.  
VI. WARRANTY  
This fan is warranted against all defects which are proved to be fault in our  
workmanship and material for one year from the date of our delivery. The sole  
responsibility under the warranty shall be limited to the repair of the fan or the  
replacement thereof, at SUNON’s sole discretion. SUNON will not be responsible for  
the failures of its fans due to improper handing, misuse or the failure to follow  
specifications or instructions for use. In the event of warranty claim, the customer shall  
immediately notify SUNON for verification. SUNON will not be responsible for any  
consequential damage to the customer’s equipment as a result of any fans proven to be  
defective.  
建 準 電 機  
SUNONWEALTH  
2012.07.23  
Page 13 of 14  
Declaration of RoHS  
Control declaration of environment-related substances/materials  
1. In accordance with the Restriction of Hazardous Substances (RoHS) Directive,  
Sunon product have complied with law and discipline not to employ the forbidden  
substances, and restrict the allowable concentration of some limited substances  
deliberately in our components.  
No  
1
Substance  
CFCs & HCFCs (ozone depleting substances)  
Chlorinated Organic Solvent  
Criteria  
Forbidden  
Forbidden  
2
Plastic (Frame, Impeller, wire harness, etc.) <100ppm  
Solder  
<1000ppm  
<3500ppm  
<4000ppm  
<4wt%  
3
Lead and its compounds  
Steel alloy  
Aluminium alloy  
Copper alloy  
Solder  
<20ppm  
Parts composed of metals containing zinc  
(e.g. brass, zinc for die casting)  
Plastic  
4
Cadmium and its compounds  
<100ppm  
<5ppm  
5
6
PBBs and PBDEs  
PCB and PCT  
Forbidden  
Forbidden  
Forbidden  
Forbidden  
Forbidden  
<100ppm  
Forbidden  
Forbidden  
Forbidden  
Forbidden  
<1000ppm  
<1000ppm  
7
CP, Short-chain Chlorinated paraffins C10-13, Cl 48 wt%  
8
Mirex  
9
PCN  
10  
11  
12  
13  
14  
15  
16  
Hexavalent Chromium compounds  
Mercury and its compounds  
Asbestos  
Organic Tin compounds  
Azo compounds  
TBBP-A in external case plastic parts of products (PCB is exempted)  
Nickel in external case parts, which are likely to result in prolonged skin exposure  
建 準 電 機  
SUNONWEALTH  
Page 14 of 14  
2012.07.23  

相关型号:

D04072110G-00

SPECIFICATION FOR APPROVAL
ETC

D0420SD-42-2001FN

Vacuum Fluorescent Display Specification
NEWHAVEN

D0420SD-53-4001F

Vacuum Fluorescent Display Specification
NEWHAVEN

D0420SD-53-4001FN

Vacuum Fluorescent Display Specification
NEWHAVEN

D04271-000

T107M Handheld Printer
TE

D04377-000

7mm Series Metal Oxide Varistors
TE

D04499-000

20mm Series Metal Oxide Varistors
TE

D04600-000

5mm Series Metal Oxide Varistors
MACOM

D04814-000

Overcurrent Protection Device
TE

D04822-000

PolySwitch? PTC Devices
TE

D048C010T010M1N

220W DC/DC CONVERTER PRELIMINARY
POWERBOX

D048C010T010M2N

DC-DC Converters Quarter Brick, 48 Vin Family
VICOR