D311RP [ETC]

Short Circuit Protected Regulated, 3W SIP DC/DC Converters; 短路保护功能调节, 3W SIP DC / DC转换器
D311RP
型号: D311RP
厂家: ETC    ETC
描述:

Short Circuit Protected Regulated, 3W SIP DC/DC Converters
短路保护功能调节, 3W SIP DC / DC转换器

转换器
文件: 总2页 (文件大小:101K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Model Selection Guide  
Input  
Output  
Fuse Rating  
Slow-Blow  
(mA)  
Model  
Efficiency  
(%, Typ)  
Voltage (VDC)  
Nominal Range  
Current (mA)  
Voltage  
(VDC)  
Current  
Current  
Number  
(mA, Max) (mA, Min)  
Full-Load No-Load  
D301RP  
D302RP  
D303RP  
D304RP  
D305RP  
D311RP  
D312RP  
D313RP  
D314RP  
D315RP  
D321RP  
D322RP  
D323RP  
D324RP  
D325RP  
5
5
5
5
4.5 - 5.5  
4.5 - 5.5  
4.5 - 5.5  
4.5 - 5.5  
4.5 - 5.5  
10.8 - 13.2  
10.8 - 13.2  
10.8 - 13.2  
10.8 - 13.2  
10.8 - 13.2  
21.6 - 26.4  
21.6 - 26.4  
21.6 - 26.4  
21.6 - 26.4  
21.6 - 26.4  
895  
895  
833  
833  
857  
373  
373  
347  
347  
357  
192  
192  
179  
179  
174  
90  
90  
90  
90  
90  
60  
60  
60  
60  
60  
30  
30  
30  
30  
30  
5.0  
9.0  
12.0  
15.0  
24.0  
5.0  
600.0  
333.0  
250.0  
200.0  
125.0  
600.0  
333.0  
250.0  
200.0  
125.0  
600.0  
333.0  
250.0  
200.0  
60.0  
33.0  
25.0  
20.0  
12.5  
60.0  
33.0  
25.0  
20.0  
12.5  
60.0  
33.0  
25.0  
20.0  
12.5  
67  
67  
72  
72  
70  
67  
67  
72  
72  
70  
65  
65  
70  
70  
72  
1,500  
1,500  
1,500  
1,500  
1,500  
700  
700  
700  
700  
700  
5
12  
12  
12  
12  
12  
24  
24  
24  
24  
24  
9.0  
12.0  
15.0  
24.0  
5.0  
9.0  
12.0  
15.0  
350  
350  
350  
350  
Derating2C4.u0 rve 125.0  
350  
Notes:  
1. Output load regulation is specified for a load change  
of 20% to 100%.  
2. When measuring output ripple, it is recommended  
that an external 0.33 μF ceramic capacitor be placed  
from the +Vout pin to the -Vout pin.  
3. Operation at no-load will not damage these units.  
However, they may not meet all specifications.  
4. These do not require external components to operate,  
but the use of a low ESR capacitor (approximately  
10 uF, ESR <1.0Ω at 100 kHz) mounted close to the  
converter input pins is recommended.  
5. It is recommended that a fuse be used on the input of  
a power supply for protection. See the table above for  
the correct rating.  
Capacitive  
Pin Connections  
Load  
Pin  
1
Function  
+Vin  
NC  
Mechanical Dimensions  
μF Max  
470  
2
3
NC  
9
NC  
10  
11  
12  
-Vout  
+Vout  
-Vin  
NC: No Connection  
Notes:  
All dimensions are typical in inches (mm)  
Tolerance x.xx = 0.01 ( 0.25)  
Pin 1 is marked by a “dot” or indentation on the side of the unit  
MicroPower Direct  
www.micropowerdirect.com  
232 Tosca Drive Stoughton, MA 02072  
TEL: (781) 344-8226  
FAX: (781) 344-8481  
E-Mail: sales@micropowerdirect.com  

相关型号:

D311RPI

Analog Circuit
MPD

D311RW

Single & Dual Output 3W SIP, Wide Input DC/DC Converters
MPD

D3121

Ground isolation amplifier circuit
YONGFUKANG

D3121F

Ground isolation amplifier circuit
YONGFUKANG

D3121N

Ground isolation amplifier circuit
YONGFUKANG

D312C

1.7MHz, 600mA Synchronous Step-Down Converter
MPS

D312F

Fixed Inductors for Cellular Phone
TOKO

D312F1001F

Interconnection Device
AMPHENOL

D312F1001I

Interconnection Device
AMPHENOL

D312F1003F

Interconnection Device
AMPHENOL

D312F1003I

Interconnection Device
AMPHENOL

D312F1003M

Interconnection Device
AMPHENOL