DEM-OPA660-1GC [ETC]

DEM-OPA660-1GC - DISCONTINUED PRODUCT. No longer recommended for new design. ; DEM - OPA660-1GC - 停产的产品。不再建议用于新设计。\n
DEM-OPA660-1GC
型号: DEM-OPA660-1GC
厂家: ETC    ETC
描述:

DEM-OPA660-1GC - DISCONTINUED PRODUCT. No longer recommended for new design.
DEM - OPA660-1GC - 停产的产品。不再建议用于新设计。\n

文件: 总3页 (文件大小:155K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
®
DEM-OPA660-1GC  
EVALUATION FIXTURE  
FEATURES  
DESCRIPTION  
EASY AND FAST PERFORMANCE TESTING  
SHOWS OPTIMIZED BOARD LAYOUT  
REPLACES SELF-MADE BOARDS  
The demo fixture DEM-OPA660-1GC allows easy and  
fast performance testing of the OPA660AP building  
blocks OTA and buffer stage. Figure 1 shows a diagram  
of the test fixture, and Figures 2, 3 and 4 show the  
frequency responses of the OTA stage measured at  
gains 1, 2, and 10 with various output levels from  
0.2Vp-p to 5Vp-p.  
APPLICATIONS  
COMPONENTS INCOME CONTROL  
PERFORMANCE CHECKS  
CIRCUIT DESIGNS  
Figure 5 illustrates the frequency response of the buffer  
stage. The silk-screen and the double-sided layout can  
be seen in Figure 6.  
ABSOLUTE MAXIMUM RATINGS  
Power Supply Voltage  
±6V  
Input Voltage  
±VCC, ±0.7V  
–40°C to +85°C  
±15mA  
Operating Temperature  
Current Output  
Quiescent Current  
±26mA  
International Airport Industrial Park  
Mailing Address: PO Box 11400  
Cable: BBRCORP  
Tucson, AZ 85734  
Street Address: 6730 S. Tucson Blvd.  
Tucson, AZ 85706  
Tel: (602) 746-1111 Twx: 910-952-1111  
Telex: 066-6491  
FAX: (602) 889-1510  
Immediate Product Info: (800) 548-6132  
© 1991 Burr-Brown Corporation  
LI-407  
Printed in U.S.A. October, 1991  
R5  
R6  
5
6
BUF In  
1
BUF Out  
OTA Out  
R7  
+5V  
–5V  
R2  
1
Rqc  
470p  
10n  
470p  
10n  
8
R1  
R3  
3
OTA In  
2
2.2µ  
2.2µ  
C1  
C2  
R4  
IN4007  
7
4
FIGURE 1. Block Diagram of Test Fixture.  
20  
15  
20  
15  
2.8Vp–p  
2.8Vp–p  
10  
10  
1.4Vp–p  
5
5
0
1.4Vp–p  
0.6Vp–p  
0
0.6Vp–p  
–5  
–5  
–10  
–15  
–20  
–25  
dB  
–10  
–15  
–20  
–25  
dB  
0.2Vp–p  
0.2Vp–p  
1M  
10M  
100M  
1G  
1M  
10M  
Frequency (Hz)  
IQ = 20mA, R1 = 100Ω, R4 = 51Ω, RA = 50Ω, Gain = 1  
100M  
1G  
Frequency (Hz)  
IQ = 20mA, R1 = 100Ω, R4 = 51Ω, RA = 100Ω, Gain = 2  
FIGURE 2. OTA Frequency Response, G = 1.  
FIGURE 3. OTA Frequency Response, G = 2.  
20  
20  
15  
5Vp–p  
15  
2.8Vp–p  
2.8Vp–p  
10  
10  
5
0
1.4Vp–p  
0.6Vp–p  
5
0
1.4Vp–p  
0.6Vp–p  
–5  
–5  
–10  
–15  
–20  
–25  
dB  
–10  
–15  
–20  
0.2Vp–p  
0.2Vp–p  
–25  
dB  
1M  
10M  
100M  
1G  
1M  
10M  
100M  
1G  
Frequency (Hz)  
Frequency (Hz)  
IQ = 20mA, R5 = 160Ω, RA = 100Ω  
IQ = 20mA, R1 = 100Ω, R4 = 51Ω, RA = 500Ω, Gain = 10  
FIGURE 4. OTA Frequency Response, G = 10.  
FIGURE 5. BUF Frequency Response.  
®
DEM-OPA660-1GC  
2
-1GC  
FIGURE 6. Silk Screen and Board Layouts.  
Test Circuit OPA660-1GC OTA  
Network Analyzer  
R2  
Out  
R3  
8
2
R1  
DT  
50Ω  
50Ω  
3
In  
• • •  
50Ω  
Generator  
R4  
Ra = R2 + R3 || 50Ω  
Test Circuit OPA660-1GC BUF  
Network Analyzer  
R5  
R6  
50Ω  
Out  
R7  
DB  
5
6
In  
50Ω  
50Ω  
• • •  
Generator  
R
a = R6 + R7 || 50Ω  
FIGURE 7. Test Configuration for Frequency Response Measurements.  
ORDERING INFORMATION  
MODEL  
DESCRIPTION  
TEMPERATURE RANGE  
DEM-OPA660-1GC  
Diamond Transistor  
and Buffer  
–25°C to +85°C  
®
3
DEM-OPA660-1GC  

相关型号:

DEM-OPA660-2GC

DEM-OPA660-2GC - DISCONTINUED PRODUCT. No longer recommended for new design.
ETC

DEM-OPA660-3GC

DEM-OPA660-3GC - DISCONTINUED PRODUCT. No longer recommended for new design.
ETC

DEM-OPA660-4G

DEM-OPA660-4G - DISCONTINUED PRODUCT. No longer recommended for new design.
ETC

DEM-OPA660-5G

DEM-OPA660-5G - DISCONTINUED PRODUCT. No longer recommended for new design.
ETC

DEM-OPA68XP

DEM-OPA68xP - Evaluation Fixture
ETC

DEM-OPA68XU

EVALUATION FIXTURE
BB

DEM-OPA6XXN

DEM-OPA6xxN - Evaluation Fixture
ETC

DEM-P

D Subminiature Connector, Male, Solder Terminal, Plug
ITT

DEM-PCM1702

DEM-PCM1702 - EVALUATION FIXTURE
ETC

DEM-PCM1704

EVALUATION FIXTURE
BB

DEM-PCM1710

DEM-PCM1710 - EVALUATION FIXTURE
ETC

DEM-PCM1717/DEM-PCM1717-1/DEM-DAI1717

DEM-PCM1717. DEM-PCM1717-1. DEM-DAI1717 - EVALUATION FIXTURE
ETC