DMS-40PC-2

更新时间:2024-09-18 02:21:50
品牌:ETC
描述:4 1/2Digit, LED Display Precision, Miniature Digital Panel Voltmeters

DMS-40PC-2 概述

4 1/2Digit, LED Display Precision, Miniature Digital Panel Voltmeters 4 1 / 2DIGIT , LED显示屏精密,微型数字式面板电压表

DMS-40PC-2 数据手册

通过下载DMS-40PC-2数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。

PDF下载
®
®
www.datel.com  
DMS-40PC Series  
4½ Digit, LED Display  
Precision, Miniature  
Actual Size  
Digital Panel Voltmeters  
DMS-40PC Series, 4½ Digit, LED Display, Miniature DPM's are fully self-contained,  
component-like, plug-in meters that provide scientific-grade accuracy (typically ±2  
counts or ±0.005% of full scale) and outstanding reliability at a very affordable price.  
Within its miniature (2.17" x 0.92" x 0.56"), epoxy-encapsulated package, each  
meter contains a precision reference circuit; a high-resolution, autozeroing, factory-  
calibrated A/D converter; and a large (0.52"/13.2mm), easy-to-read, LED display.  
LED's are available in red, yellow and green colors. Red LED's are also offered in  
high-intensity or low-power versions.  
Features  
Precision, autozeroing, factory-  
calibrated A/D converter  
Scientific-grade accuracy, ±± counts  
Miniature size:  
±.17" x 0.9±" x 0.56"  
55mm x ±3mm x 14mm  
The versatile design of the DMS-40PC Series assures trouble-free installation and  
long-term operation. Differential input voltage ranges include ±2V, ±20V and ±200V.  
Input impedance is a minimum 800k. Non-inverting inputs are overvoltage protected  
to ±250V, and CMRR is typically 86dB (dc to 60Hz).  
The DMS-40PC's epoxy-encapsulated package has an integral bezel and color  
filter. The moisture and vibration-proof package is extremely rugged and well suited for  
harsh environments and extended temperatures. Devices are fully specified for  
0 to +50°C operation.  
All models operate from a single +5V supply and typically consume 500mW. Low-  
power models, whose display is just as bright as standard models, typically consume  
175mW. DISPLAY TEST and HOLD functions are standard on each meter, and a  
complete set of BCD outputs are optional for sending data to CPU's or remote  
displays.  
Large (0.5±"/13.±mm) LED display  
Choice of red, green or yellow colors  
High-intensity or low-power red  
LED's optional  
Single +5V supply (175mW for low-  
power models)  
Epoxy-encapsulated, 1±-pin DIP with  
built-in color filter and bezel  
3 differential input voltage ranges  
DISPLAY HOLD and TEST functions  
Optional BCD data outputs for CPU  
interface  
0 to +50°C temperature range  
+5V  
1
12  
V+  
V–  
(–) INPUT LO  
(+) INPUT HI  
+5V SUPPLY  
1
R2  
0.01µF  
–5V  
R1  
909k  
2
11  
10  
DC/DC  
CONVERTER  
DISPLAY TEST  
ANALOG  
3
A/D  
CONVERTER  
COMMON  
5V RETURN  
0 Vdc  
2.5V  
REF.  
DATA  
4
DP 3  
9
8
7
DISPLAY HOLD  
DP4  
5
DP 2  
6
+5V  
DP 1  
REFERENCE IN/OUT  
1
R2 is not used on 2V (-1) models.  
R2 = 101k on 20V (-2) models and 9.2k on 200V (-3) models.  
Figure 1. DMS-40PC Series Simplified Schematic  
DATEL, Inc., Mansfield, MA 02048 (USA) Tel: (508)339-3000, (800)233-2765 Fax: (508)339-6356 Email:sales@datel.com Internet: www.datel.com  
4½ D I G I T, L E D D I S P L A Y D I G I T A L P A N E L V O L T M E T E R S  
DMS-40PC  
Performance/Functional Specifications  
Typical at TA = +25°C and supply voltage = +5V using the single-ended input circuit,  
unless otherwise noted.  
Order on-line at www.datel.com  
Analog Inputs  
Min.  
Typ.  
Max.  
Units  
Ordering Information  
Full Scale Input Range:  
DMS-40PC-1  
DMS-40PC-2  
--  
--  
--  
2
20  
200  
--  
--  
--  
Volts  
Volts  
Volts  
DMS-40PC - 1 - R S  
DMS-40PC-3  
LED Color:  
GS = Standard Green  
Input Impedance:  
DMS-40PC-1  
DMS-40PC-2, -3  
Input Range:  
1 = 2V  
± = 20V  
RH = High-Intensity Red  
RL = Low-Power Red  
RS = Standard Red  
100  
0.8  
1000  
1
--  
--  
M
M
Overvoltage Protection  
--  
--  
--  
--  
--  
250  
2
Volts  
Volts  
dB  
3 = 200V  
YS = Standard Yellow  
Common Mode Voltage Range  
CMRR (dc to 60Hz)  
86  
--  
BCD Output Models:  
BCD outputs are only available on standard red meters.  
DMS-40PC-1-RS-BCD for 2V input range  
DMS-40PC-±-RS-BCD for 20V input range  
DMS-40PC-3-RS-BCD for 200V input range  
DMS-40PC-1-RL-BCD for 2V input range  
DMS-40PC-±-RL-BCD for 20V input range  
DMS-40PC-3-RL-BCD for 200V input range  
Control Inputs  
Decimal Point Placement (Pins 4-6, 8)  
Tie to pin 3 to activate  
Display Test (Pin 2)  
Tie to pin 3 to activate all segments  
Tie to pin 3 to hold last reading  
Display Hold (Pin 9)  
BCD Outputs ➀  
Logic levels (1 LSTTL load max.):  
Logic "1"  
Logic "0"  
Accessories:  
+2.4  
--  
--  
+0.4  
--  
+0.8  
Volts  
Volts  
DMS-PS1-CM  
DMS-30-CP  
DMS-BZL1  
DMS-BZL±  
DMS-EB  
+5V/1.0A AC/DC power supply module  
Panel cutout punch  
DMS-40 bezel assembly  
Performance  
Sampling Rate  
DMS-40 bezel assembly with sealing gasket  
Application/evaluation board with standard  
MOLEX connector, decimal point solder pads  
and attenuation resistor pads.  
2.5 samples per second  
Accuracy (15 minute warm-up):  
DMS-40PC-1 (VIN = +1.9V)  
DMS-40PC-2 (VIN = +19V)  
DMS-40PC-3 (VIN = +190V)  
--  
--  
--  
2
3
3
3
4
4
Counts  
Counts  
Counts  
A panel-mount retaining clip is supplied with each model.  
Zero Reading (VIN = 0 Volts)  
"0001"  
"0000"  
"0001"  
Technical Notes  
Temperature Drift (0 to +50°C):  
DMS-40PC-1  
DMS-40PC-2, -3  
--  
--  
0.4  
0.4  
1
1.5  
Cnts/°C  
Cnts/°C  
1. ANALOG COMMON (Pin 10): This pin is an internal, low-noise  
ground for the DMS-40PC. It is internally connected to pin 3  
(5V RETURN). Do not connect pin 10 to either pin 3 or your  
system ground as this will create a ground loop and possibly result  
in erroneous readings.  
Power Supply Requirements  
Supply Voltage  
+4.75  
+5.00  
+5.25  
Volts  
Supply Current:  
Standard Models  
Low-Power Models  
--  
--  
+100  
+35  
+140  
+50  
mA  
mA  
±. REFERENCE INPUT/OUTPUT (Pin 7): This pin accesses the  
meter's internal reference and is used during the factory calibration  
procedure. Pin 7 should be left open in most common applications.  
It can be used in certain "ratiometric" applications in which it is  
desirable for the meter’s reference to track an external reference.  
See Ap Note 3 in the DATEL Panel Meter Catalog for more details.  
Display  
Display Type and Size  
4½ Digit LED, 0.52"/13.2mm high  
Autopolarity ("–" for negative VIN)  
Polarity Indication  
Overrange Indication  
"0000" (flashing) for negative VIN  
"0000" (flashing) for positive VIN  
3. DISPLAY TEST (Pin ±): Connecting pin 2 to ground (pin 3, 5V  
RETURN) will activate all LED segments, and the display will read  
"–18888" regardless of the actual applied input. To reduce self-  
heating, the display should not be left in the "test" mode for  
more than 10 seconds. This pin should be left open if unused.  
Physical/Environmental  
Operating Temperature  
Storage Temperature  
Humidity (Non-condensing)  
Case Material  
0
–20  
0
--  
--  
--  
+50  
+75  
95  
°C  
°C  
%
4. DISPLAY HOLD (Pin 9): For normal operation, this pin should be  
left open. To hold the meter’s last reading and display it continu-  
ously, tie pin 9 to ground (pin 3, 5V RETURN).  
Polycarbonate  
Weight  
0.75 ounces (21 grams)  
Applies for transient or continuous overvoltages applied to (+) INPUT HI (pin 11)  
5. Decimal Point Placement: The location of the decimal point is  
user-selectable, and the decimal point control pins (DP1-DP4) are  
active low functions. Select the appropriate decimal point by tying  
pin 4, 5, 6 or 8 to pin 3 (5V RETURN). Unused decimal point  
location pins should be left open.  
with (–) INPUT LO (pin 12) properly connected. Pin 12 is not overvoltage protected  
(see Figure 1). Voltages applied to pin 12 should not exceed the supply voltage.  
See Technical Notes.  
BCD outputs are optional and must be specified in the part number.  
See Ordering Information.  
Includes high-intensity and BCD-output models.  
2
4½ D I G I T, L E D D I S P L A Y D I G I T A L P A N E L V O L T M E T E R S  
DMS-40PC  
Hard wiring is preferable, however, you can exercise dynamic  
control over the location of the decimal point by employing drive  
circuits that are capable of sinking a minimum of 20mA at  
voltages less than +0.4 Volts.  
The DMS-40PC's simplified schematic, shown in Figure 1, can be  
very useful when debugging a malfunctioning circuit, especially if  
the user has some knowledge of operational amplifiers (op amps).  
The meter's high-impedance input consists of an op amp powered  
from a 5Vdc power supply (the –5V is internally generated). Figure  
1 shows that input signals applied to (–) INPUT LO and (+) INPUT  
HI must to be kept within the 5V power-supply rails. Also note that  
6. Gain Adjust: There is a gain-adjust potentiometer on the back  
of each meter. It has approximately 150 counts of adjustment  
range. Since these meters essentially have no zero/offset errors,  
a gain adjustment is effectively an overall accuracy adjustment.  
Though they may be performed at any point (except zero),  
accuracy adjustments are most effective when performed with  
higher level input signals.  
only pin 11 has a current-limiting 909k  
series resistor. High input  
voltages that have a common ground connection with pin 3 (5V  
RETURN) should only be applied to pin 11 ((+) INPUT HI) and never  
to pin 12. In these high-voltage cases, pin 12 should always be tied  
to pin 3 (5V RETURN).  
7. Soldering Methods: All models in the DMS-40PC Series easily  
withstand most common wave soldering operations. We  
recommend, however, that you evaluate the effects your  
particular soldering techniques may have on the meter's plastic  
case and high-precision electrical performance. We recommend  
the use of water-soluble solders and thorough cleaning  
procedures.  
One of the simplified schematic's more noteworthy features is that it  
shows some DMS-40PC internal voltage values and also that pin 3  
is the meter's zero-volt reference point — regardless of the type of  
power or signal source used. This is an important point to keep in  
mind when using digital multimeters to perform system-level  
measurements. The multimeter's negative lead (usually the black  
one) must always be connected to pin 3 (5V RETURN). This is the  
only way accurate readings can be made, particularly if the meter is  
configured for a differential input and concerns arise regarding  
common-mode voltages.  
8. Suggested Mating Connectors:  
Panel mounted:  
Connector housing  
Terminal type  
Crimping tool  
DATEL P/N 39-2079400  
DATEL P/N 39-2099090  
DATEL P/N 39-2099000  
22 to 26 AWG  
1. Single-Ended Input Configurations: The DMS-40PC can  
measure single-ended signals with either positive or negative  
polarities. True single-ended inputs always have one of their two  
terminals at the same potential as the DMS-40PC's 5V RETURN  
(pin 3). Single-ended inputs are usually derived from power  
supplies that have a common ground with the meter’s +5V  
supply. Figure 2 shows the recommended connections to be  
used with this type of input. Pin 12, (–) INPUT LO, is shown  
directly tied to ground. This connection to ground must be a  
separate wire or pc-board trace originating at VIN's negative  
terminal. This hook-up will normally eliminate display instabilities  
and errors caused by ground-loop currents which can occur if  
(–) INPUT LO is tied to ground at, or near, pin 3.  
Wire size  
Insulation diameter  
Stripping length  
0.062" (1.57mm) maximum  
0.100 to 0.125" (2.54 to 3.17mm)  
Board mounted:  
Socket  
DATEL P/N 39-2359625  
Applications  
DMS-40PC Series meters are high-precision versatile devices that  
can be used in many applications requiring a 0 to 19,999 count  
digital display. The application circuits chosen for this section are  
ones that have historically received many inquiries. Every attempt  
has been made to ensure technical accuracy, and all of the following  
circuits have been prototyped and tested to ensure functionality.  
Please keep in mind, however, that real-world applications are  
seldom as straightforward as the approaches presented here.  
D
M
S
-
4
0
P
C
-
1
-
G
S
1
1
(
+
)
I
N
H
I
+
V
I
N
All inputs applied to DMS-40PC meters must be steady, dc values,  
otherwise the input itself may cause display instabilities. Due to their  
4½ digit resolution, DMS-40PC meters must be wired with greater  
care than their 3½ digit counterparts. Correct power-supply and  
input-signal wiring — an absolute must! — helps eliminate ground-  
loop induced errors that show up as unstable display readings.  
When an input signal, assumed to be exactly zero volts, has a 1mV  
(0.001V) ground-loop induced offset, it is displayed as "0010" on a  
2V input-range meter! DATEL's new Digital Panel Meter Catalog  
contains an application note describing power supply wiring and  
ground loop avoidance techniques.  
–
1
2
(
–
)
I
N
L
O
1
6
3
+
5
V
S
U
P
D
P
1
5
V
R
E
T
D
A
T
E
L
8
5
-
2
6
4
V
a
c
D
M
S
-
P
S
1
-
C
M
A
C
t
o
D
C
C
o
n
v
e
r
t
e
r
Figure ±. Single-Ended Input Configuration  
3
DMS-40PC  
4½ D I G I T, L E D D I S P L A Y D I G I T A L P A N E L V O L T M E T E R S  
Applications  
±. Differential Input Configurations: Differential inputs can also  
be measured with DMS-40PC meters as shown in the circuit of  
Figure 3. Differential inputs must also originate from power  
supplies that have a common ground with the meter's 5V  
RETURN (pin 3). However, differential inputs usually have both  
terminals above and/or below 5V RETURN. Figure 3, though not  
necessarily a typical real-world application, does serve the  
purpose of illustrating the concept of a differential signal.  
which low calibration drift is desirable. When using other, higher-  
power, DMS-40PC models in combination with three-terminal  
regulators, be sure to consult the regulator manufacturer's data  
sheet to ensure the device is being utilized safely and correctly.  
(+) IN HI  
11  
DMS-40PC-±-RL  
LM2931T-5  
1
The voltages developed across R1, R2 and R3 are equal to each  
other and measure approximately +1.6666Vdc or 1/3 of the +5V  
power source. More importantly, while the signal across R3 is  
single-ended, both ends of R1 and R2 are well above ground  
and are described here as being differential. Please note that  
while the DMS-40PC can measure the voltages across either R2  
or R3, it cannot measure the +1.6666 volts across R1! The  
voltage at the lower end of R1 is approximately 3.333V and this  
exceeds the common mode voltage limit of 2V.  
+5V SUP  
IN  
OUT  
GND  
3
+
+
5V RET  
4.5 - 18Vdc  
22µF  
10V  
5
DP2  
1±  
(–) IN LO  
Figure 4. 4.5-18V Power Supply Monitor  
4. Floating Signal Source Measurements: A floating input is a  
signal that, before it is applied to the DMS-40PC's inputs, has no  
galvanic connection (direct current path) to the meter or the  
meter's power supply. The circuit shown in Figure 5 illustrates  
the necessary connections for measuring floating inputs. The  
1.5V battery represents a true floating input signal since it  
initially has no connection whatsoever in common with the  
meter. Real-world floating inputs typically originate from power  
supplies which are transformer isolated from the DMS-40PC’s  
+5V supply.  
R
1
D
M
S
-
4
0
P
C
-
1
-
G
S
1
1
1
k
(
+
)
I
N
H
I
D
P
1
R
2
1
2
1
k
(
–
)
I
N
L
O
R
3
1
3
1
k
+
5
V
S
U
P
5
V
R
E
T
D
A
T
E
L
5
-
2
6
4
V
a
c
D
M
S
-
P
S
1
-
C
M
The connection of pin 12 ((–) INPUT LO) to pin 10 (ANALOG  
COMMON) is required in order to provide a bias return for the  
meter’s input amplifier. This is because neither pin 11 nor pin 12  
are tied to any reference voltage inside the DMS-40PC (see  
Figure 1). These connections are not made internally in order to  
give the meter the ability to make differential measurements as  
described in a previous section.  
A
C
t
o
D
C
C
o
n
v
e
r
t
e
r
Figure 3. Differential Input Configuration  
3. Power Supply Monitoring: One of the most widely used digital  
panel voltmeter applications is monitoring the output voltage of a  
system power supply — often the same supply that also powers  
the meter. The low-power, red LED DMS-40PC-2-RL, with its  
excellent 0.001Vdc resolution, can be configured to monitor  
power supplies with outputs in the range of 4.5-18Vdc. The  
circuit in Figure 4 uses a low-drop-out, three-terminal regulator  
(LM-2931T-5, in a T0-220 package, available from National  
Semiconductor) to provide regulated 5V power to the meter.  
1
1
1
1
0
2
D
M
S
-
4
0
P
C
-
1
-
G
S
(
+
)
I
N
H
I
A
N
A
(
C
O
M
M
1
.
5
V
C
E
L
L
–
–
)
I
N
L
O
3
6
1
5
V
R
E
T
D
P
1
+
5
V
S
U
P
The LM-2931 was chosen because it has the following on-chip  
protection features: reverse polarity, short circuit and thermal  
runaway. The DMS-40PC-3-RL can monitor voltages up to  
200Vdc, provided a separate +5V power source is used since  
many three-terminal regulators cannot operate with supply  
voltages greater than 24V. Red, low-power LED models, with  
their very low self-heating, are recommended for applications in  
D
A
T
E
L
8
5
-
2
6
4
V
a
c
D
M
S
-
P
S
1
-
C
M
A
C
t
o
D
C
C
o
n
v
e
r
t
e
r
Figure 5. Floating Input Measurements  
4
4½ D I G I T, L E D D I S P L A Y D I G I T A L P A N E L V O L T M E T E R S  
DMS-40PC  
Applications  
5. Engineering Scaling and Input Attenuation: In many  
applications, the input signal must be scaled, or divided down,  
before being applied to the DMS-40PC. In some situations, the  
input signal exceeds the full-scale range of the meter, and in  
other applications, a direct one-to-one relation does not exist  
between the input voltage and the desired display reading. For an  
example of the second situation, assume an input voltage of  
1.0Vdc is required to display a reading of "7500" when applied to  
simplest way of implementing an external display. A seventy-five  
to one-hundred Ohm resistor on each LS247 segment-drive  
output provides adequate display brightness.  
The functions of pins A - L are listed below:  
BCD DATA (pins I - L): Four lines are used for BCD (Binary Coded  
Decimal) data outputs, representing the numbers 0 - 9. Positive-logic  
convention (a high represents a "1") is used.  
a
2V input meter. An input divider circuit, constructed with two  
DIGIT DRIVE ( pins A - E): These five outputs, when gated with  
STROBE, can be used to direct the BCD DATA into external latches.  
DIGIT DRIVE outputs may also be connected directly to the bases of  
NPN transistors in remote-display configurations. The digits are  
scanned right-to-left, i.e., MSD (DIGIT 1 DRIVE) to LSD (DIGIT 5  
DRIVE).  
series resistors with an output-to-input ratio of 0.75, will scale the  
1.0V signal down to 0.75V.  
Engineering scaling and input attenuation are discussed in Ap  
Note 4 of the DATEL Digital Panel Voltmeter Catalog. Compen-  
sating for inputs which have a zero offset is also discussed.  
BUSY (pin G): This is a status pin that goes high at the start of an  
analog-to-digital (A/D) conversion cycle and remains high until the  
conversion ends.  
6. BCD Outputs (DMS-40PC-X-RS and -RL-BCD Models Only):  
Models with a "-BCD" suffix have 12 extra output pins, labeled  
A through L (6 per side), that provide the following information:  
multiplexed serial BCD data, digit drive, and polarity indication.  
The data present on pins A - L simultaneously drives the meter's  
internal LED display. All functions on pins A - L are 5V CMOS  
compatible, however, they are only rated to drive one, 74LS  
series, TTL load. CMOS logic IC's, for example 74HC or 74HCT  
series devices, should be used when more fan-out capability  
is required.  
STROBE (pin H): A string of five sequential, active-low, STROBE  
pulses are output (after BUSY goes low) indicating the end of a  
conversion and the availability of new data. The 5 STROBE pulses  
occur only once per conversion, or 2.5 times each second. STROBE  
can be used to latch the BCD data (on pins I - L) into external  
latches. Either edge can be used since STROBE (~ 5µsec wide) is  
active only in the center of the corresponding DIGIT DRIVE and BCD  
DATA outputs.  
As the timing diagram in Figure 5 indicates, 100Hz is the  
optimum display scan rate when the BCD outputs are used to  
drive external LED displays. Faster scan rates, while permissible,  
are not necessary. Slower scanning, however, may result in  
noticeable "flickering" of the display. Common anode LED's,  
combined with a 74LS247 BCD to seven-segment decoder, is the  
POLARITY (pin F): This pin, which is also used inside the DMS-  
40PC to drive the negative-sign segment, indicates whether the last  
input signal conversion was positive (POLARITY set high) or  
negative (POLARITY set low). POLARITY, unlike BCD DATA, is not  
multiplexed. For data latching purposes, POLARITY should be  
sampled during the STROBE pulse for digit 1 (most significant digit).  
Approx. 8msec  
Approx. 2msec  
DIGIT DRIVE 1  
(MSD)  
Approx. 2msec  
DIGIT DRIVE 2  
DIGIT DRIVE 3  
DIGIT DRIVE 4  
DIGIT DRIVE 5  
(LSD)  
BUSY  
Approx. 5µsec  
STROBE OUT  
5 Strobes Only Per Conversion  
Data from  
Previous Conversion  
BCD DATA  
(4 LINES)  
1
2
3
4
5
1
2
3
4
5
MSD  
LSD  
Figure 6. BCD Data Timing Diagram  
5
4½ D I G I T, L E D D I S P L A Y D I G I T A L P A N E L V O L T M E T E R S  
DMS-40PC  
Mechanical Specifications  
MECHANICAL DIMENSIONS: Inches (mm)  
TOLERANCES: 2 PL DEC ±0.02 (±0.51)  
3 PL DEC ±0.010 (±0.254)  
X X - X P C 4 - 0 S - D M  
PIN #1  
IDENTIFIER  
LEAD DIMENSIONS: 0.025 (0.635) x 0.025 (0.635) NOMINAL  
A
U N S I  
M A D E  
RECOMMENDED PC BOARD FINISHED HOLE DIAMETER:  
0.042 ±0.003 (1.067 ±0.076)  
®
®
INSIDE ROW (BCD MODELS ONLY)  
INSIDE ROW (BCD MODELS ONLY)  
CALIBRATION POTENTIOMETER HOLE LOCATION  
FRONT VIEW  
L
K
J
(–) INPUT LO  
L
K
J
B4  
(LSD) DIGIT 5  
(MSD) DIGIT 1  
DIGIT 2  
A
B
C
D
E
F
+5V SUPPLY  
DISPLAY TEST  
5V RETURN  
DP3  
1
±
3
4
5
6
A
B
C
D
E
F
PIN 1  
B2  
11 (+) INPUT HI  
B1 (LSB)  
B8 (MSB)  
STROBE  
BUSY  
10 ANALOG COMMON  
I
9
8
7
I
DISPLAY HOLD  
DP4  
DIGIT 3  
0.290  
(7.37)  
H
G
H
G
DIGIT 4  
DP2  
REFERENCE IN/OUT  
POLARITY  
DP1  
0.325  
(8.26)  
DP1  
DP2  
DP3  
DP4  
0.125 (3.175) DIAMETER  
(USE ONLY WHEN PC BOARD MOUNTING)  
0.92  
(23.4)  
2.17  
(55.1)  
0.84  
(21.3)  
2.09  
(53.1)  
0.560  
(14.22)  
0.040  
(1.02)  
0.25 (6.4) TYP.  
0.10  
0.040  
(1.02)  
(BCD MODELS ONLY)  
1.60  
(40.6)  
0.10  
(2.5)  
TYP.  
(2.5) TYP.  
0.17  
(4.3)  
TYP.  
0.15  
(3.7) TYP.  
1.80  
(45.7)  
0.50  
(12.7)  
0.040  
(1.02)  
OPTIONAL BEZEL (DMS-BZL1 and DMS-BZL±)  
BEZEL INSTALLATION  
0.187  
(4.75)  
#2-56 INSERT  
0.156 (3.96) DEEP  
FRONT VIEW  
ꢊꢁꢆꢃꢋ  
ꢇ ꢈ ꢆ ꢁ ꢂ ꢃ ꢄ ꢀ  
                                                                                                                                                                                                                                                                                  
                                                                                                                                                                                                                                                                                    
1.270  
(32.26)  
ꢌꢃꢍꢃꢋ  
2.55 (64.77)  
RECOMMENDED DRILL AND PANEL CUTOUT DIMENSIONS  
0.116  
(2.95)  
INTERNAL CORNER RADII:  
0.032 (0.81) MAX.  
RETAINING CLIP INSTALLATION  
0.878  
(22.30)  
1.07  
(27.18)  
PANEL CUTOUT  
ꢊꢁꢆꢃꢋ  
2.118 (53.80)  
2.35 (59.69)  
0.096  
(2.44)  
0.093 (2.362) DIAMETER (4 REQUIRED)  
ONLY WHEN USING OPTIONAL BEZEL ASSEMBLY  
®
®
ISO 9001  
DS-0272C 1/98  
R E G I S T E R E D  
DATEL (UK) LTD. Tadley, England Tel: (01256)-880444  
DATEL, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151  
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356  
DATEL S.A.R.L. Montigny Le Bretonneux, France Tel: 01-34-60-01-01  
DATEL GmbH München, Germany Tel: 89-544334-0  
Internet: www.datel.com  
Email: sales@datel.com  
DATEL KK Tokyo, Japan Tel: 3-3779-1031, Osaka Tel: 6-354-2025  
DATEL makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein  
do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. The DATEL logo is a registered DATEL, Inc. trademark.  

DMS-40PC-2 相关器件

型号 制造商 描述 价格 文档
DMS-40PC-2-RL-BCD ETC 4 1/2Digit, LED Display Precision, Miniature Digital Panel Voltmeters 获取价格
DMS-40PC-2-RS-BCD ETC 4 1/2Digit, LED Display Precision, Miniature Digital Panel Voltmeters 获取价格
DMS-40PC-3 ETC 4 1/2Digit, LED Display Precision, Miniature Digital Panel Voltmeters 获取价格
DMS-40PC-3-RL-BCD ETC 4 1/2Digit, LED Display Precision, Miniature Digital Panel Voltmeters 获取价格
DMS-40PC-3-RS-BCD ETC 4 1/2Digit, LED Display Precision, Miniature Digital Panel Voltmeters 获取价格
DMS-78XXSR MURATA 3.3V/5V/12V Outputs High-Effi ciency Switching Regulators with LM78xx Pinouts 获取价格
DMS-8-250/57837N MERRIMAC Double Balanced Mixer, 1MHz Min, 500MHz Max, 9.5dB Conversion Loss-Max 获取价格
DMS-8-250/57837S MERRIMAC Double Balanced Mixer, 1MHz Min, 500MHz Max, 9.5dB Conversion Loss-Max 获取价格
DMS-8-500/57835N MERRIMAC Double Balanced Mixer, 2MHz Min, 400MHz Max, 9dB Conversion Loss-Max 获取价格
DMS-8-500/57835S MERRIMAC Double Balanced Mixer, 2MHz Min, 400MHz Max, 9dB Conversion Loss-Max 获取价格

DMS-40PC-2 相关文章

  • Bourns 密封通孔金属陶瓷微调电位计产品选型手册(英文版)
    2024-09-20
    6
  • Bourns 精密环境传感器产品选型手册(英文版)
    2024-09-20
    9
  • Bourns POWrTher 负温度系数(NTC)热敏电阻手册 (英文版)
    2024-09-20
    8
  • Bourns GMOV 混合过压保护组件产品选型手册(英文版)
    2024-09-20
    6